Perbaikan Kestabilan Dinamik Sistem Tenaga Listrik Multimesin dengan Metoda Linear Quadratic Regulator Danas, Aidil; Dibyo Laksono, Heru; ., Syafii
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2, No 2: September 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (259.997 KB) | DOI: 10.25077/jnte.v2n2.88.2013

Abstract

System stability is an inportant part in the planning and operation of electric power systems, especially dynamic stability. The ability of a power system to maintain stability under small disturbances defined as dynamic stability. The small disturbances consist of load variation in generation side in random, slow and cascaded. This condition may change system frequency which effect in system stability and can not work normally. The aim of this research is to design suitable control system via simulation to respond small disturbances in the power system.  The simulation test system is used PT. PLN data Sumbar-Riau system under Linear Quadratic Regulator (LQR) method. The method is used to obtain control value to reach desagn criteria, that are overshoot less then 5 % and steady state time less then 4 second. The simulatino result shows that the system design have reach the criteria of design at 0.65 times basic load to 1.35 times of basic load.  Keywords : Dynamic stability, controller, Linear Quadratic Regulator (LQR)AbstrakPada perencanaan dan operasi sistem tenaga listrik, kestabilan sistem adalah hal yang sangat penting terutama kestabilan dinamik. Kestabilan dinamik adalah kestabilan sistem terhadap gangguan kecil. Gangguan kecil ini berupa perubahan beban pada sisi pembangkit secara acak, pelan, dan bertingkat. Gangguan ini mengakibatkan perubahan frekuensi yang menyebabkan kestabilan sistem berubah sehingga tidak mampu bekerja secara normal. Tujuan penelitian ini untuk mendapatkan informasi perancangan pengendali melalui simulasi untuk memperbaiki kestabilan sistem akibat perubahan beban kecil. Simulasi dilakukan pada sistem tenaga listrik PT. PLN Sumbar-Riau dengan menerapkan metoda Linear Quadratic Regulator (LQR). Metode ini digunakan mendapatkan nilai pengendali agar dapat memenuhi kriteria rancangan yang diinginkan, yaitu lewatan maksimum tidak lebih dari 5 % dan waktu keadaan mantap kurang dari 4 detik. Hasil simulasi menunjukkan rancangan pengendali memenuhi kriteria pada kondisi 0.65 kali beban dasar sampai dengan 1.35 kali beban dasar.Keywords : Dynamic stability, controller, Linear Quadratic Regulator (LQR)  
Analisa Kinerja Automatic Voltage Regulator Dalam Domain Waktu Menggunakan Metoda Ziegler-Nichols Dengan Pendekatan First Order Plus Dead Time Laksono, Heru Dibyo; Riska, N.; Novizon, Novizon
JURNAL NASIONAL TEKNIK ELEKTRO Vol 8, No 3: November 2019
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (429.564 KB) | DOI: 10.25077/jnte.v8n3.669.2019

Abstract

Electric power systems produce power that can be used for various purposes. The distribution of electrical power and its relationship to the voltage and current generated by the generator. Voltage can change with changes in load. The change of voltage is undesirable due to it can cause disturbances to the power system. A device called Automatic Voltage Regulator (AVR) is used to maintain the voltage stable. This AVR is equipped with a control system to get the voltage stability following the specified criteria. In this study, the Ziegler -Nichols (Z-N) method is used with the First Order Plus Dead Time (FOPDT) approach. FOPDT is used for AVR control based on frequency response and transfer function methods. AVR used is direct current type AVR. The design that fulfils the criteria for controlling the voltage transfer response of direct current type AVR systems is the Proportional Integral Differential (PID) controller. This PID is designed using the Ziegler-Nichols method with the FOPDT approach based on the transfer function method. Information on the simulation results of the direct current type of system switching AVR response is obtained where the steady-state error value is 0.0000, the rise time value is 0.6114 seconds, the peak time value is 1.4391 seconds, the peak value is 1.1492 seconds, the maximum throughput is 14.942% and time to state steady reaches value at 2.5562 seconds. The values of parameter control are k of 13.2000, L of 0.4283, T of 1.0817, Proportional constant (Kp) of 0.2296, integral time constant (Ti) of 0.8564 and differential time constant (Td) of 4.6667.Keywords : Ziegler-Nichols, Fisrt order plus dead time, Automatic voltage regulator, Transient analysis AbstrakSistem tenaga listrik menghasilkan daya yang dapat di gunakan untuk berbagai keperluan. Penyaluran daya listrik ini erta hubungan nya dengan tegangan dan arus yang di hasilkan oleh pembangkit. Tegangan dapat berubah-ubah dengan berubahnya beban. Perubahan tegangan ini tidak diinginkan karena dapat mengakibatkan gangguan pada sistem tenaga. Untuk menjaga agar tegangan tetap stabil digunakan Automatic Voltage Regulator (AVR). AVR ini dilengkapi dengan sistim pengendalian untuk mendapatkan kestabilan tegangan sesuai dengan kriteria yang di tetapkan. Pada penelitian ini digunakan metoda Ziegler -Nichols (Z-N) dengan pendekatan First Order Plus Dead Time (FOPDT) berdasarkan tanggapan frekuensi dan metoda fungsi alih sebagai metoda pengendali AVR dan AVR yang digunakan adalah AVR tipe arus searah.Pengendali yang memenuhi kriteria rancangan untuk pengendalian tanggapan peralihan tegangan sistem AVR tipe arus searah adalah pengendali Proporsional Integral Diferensial (PID). Pengendali Proporsional Integral Diferensial (PID) ini dirancang dengan menggunakan metoda Ziegler-Nichols dengan pendekatan First Order Plus Dead Time (FOPDT) berdasarkan metoda fungsi alih. Informasi hasil simulasi tanggapan peralihan sistem AVR tipe arus searah yang diperoleh dimana nilai kesalahan keadaan mantap sebesar 0.0000, nilai waktu naik sebesar 0.6114 detik, nilai waktu puncak sebesar 1.4391 detik, nilai puncak sebesar 1.1492 detik, nilai lewatan maksimum sebesar 14.942 % dan nilai waktu keadaan mantap sebesar 2.5562 detik. Untuk nilai parameter  pengendali yang digunakan adalah k sebesar 13.2000, L sebesar 0.4283, T sebesar 1.0817, konstanta Proporsional (Kp) sebesar 0.2296, konstanta waktu integral (Ti)  sebesar 0.8564 dan konstanta waktu diferensial (Td) sebesar 4.6667.Kata Kunci :Ziegler-Nichols, Fisrt order plus dead time, Automatic voltage regulator, Analis peralihan
Analisa Performansi Sistem Kendali Frekuensi Tenaga Listrik Multimesin Dengan Metoda Linear Quadratic Regulator (LQR) Dibyo Laksono, Heru; Permana, M. Reza
JURNAL NASIONAL TEKNIK ELEKTRO Vol 3, No 2: September 2014
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1580.533 KB) | DOI: 10.25077/jnte.v3n2.82.2014

Abstract

This journal discusses about the performance analysis of frequency control power system in multi machine with Linear Quadratic Regulator method (LQR). The frequency control power system in multi machine is power subsystem consists of two or more generators are interconnected each other and the most influential subsystem on the performance of power system primarily to the performance toward frequency deviation responses of the power system. The Performance of frequency deviation response power system is one of the important factors that must be considered in the operation of electric power system and the indicator show the performance of the power system during disturbance. Disturbances causes changes in parameter values which lead to frequency control power system in multi machine will be disrupted so it  result system no longer able to work normally after disturbance. By using the method of Linear Quadratic Regulator (LQR) is conducted performance analysis of frequency control power system in multi machine. The Performance analysis was conducted on the performance analysis in the time and frequency domain. The result of analysis shows that the performance of frequency deviation response in of multi machine frequency control power system with Linear Quadratic Regulaetor method has better performance.Keywords: Frequency control system, Multi Machine , Linear Quadratic Regulator (LQR)AbstrakJurnal ini membahas tentang analisa performansi sistem kendali frekuensi tenaga listrik multimesin dengan metoda Linear Quadratic Regulator (LQR). Sistem kendali frekuensi tenaga listrik multimesin ini merupakan subsistem tenaga listrik yang terdiri dari dua atau lebih generator yang saling terinterkoneksi dan merupakan subsistem yang paling berpengaruh terhadap performansi sistem tenaga listrik terutama performansi terhadap tanggapan deviasi frekuensi sistem tenaga listrik. Performansi tanggapan deviasi frekuensi sistem tenaga listrik ini  merupakan salah satu faktor penting yang harus diperhatikan dalam operasi sistem tenaga listrik dan merupakan salah satu indikator yang menunjukkan performansi sistem tenaga listrik saat terjadi gangguan. Gangguan – gangguan ini menyebabkanperubahan nilai parameter yang mengakibatkansistem kendali frekuensi tenaga listrik multimesin akan terganggu dan berakibat sistem tidak mampu lagi bekerja secara normal setelah mengalami gangguan. Dengan menggunakan metoda Linear Quadratic Regulator (LQR) dilakukan analisa performansi tanggapan deviasi frekuensi dari sistem kendali frekuensi tenaga listrik multimesin. Analisa performansi yang dilakukan meliputi analisa performansi dalam domain waktu dan domain frekuensi. Hasil analisa menunjukkan bahwa performansi tanggapan deviasi frekuensi sistem kendali frekuensi tenaga listrik multimesin dengan metoda metoda Linear Quadratic Regulator (LQR) mempuyai performansi yang lebih baik.Kata kunci :  sistem kendali frekuensi,  multimesin, Linear Quadratic Regulator (LQR
Analisa Kestabilan Sistem Kendali Eksitasi Generator Tipe Arus Searah Tanpa dan dengan Pengendali Berdasarkan Pendekatan Tanggapan Frekuensi Laksono, Heru Dibyo; ., Mazues; A, Wayu Diafridho
JURNAL NASIONAL TEKNIK ELEKTRO Vol 5, No 3: November 2016
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (363.998 KB) | DOI: 10.25077/jnte.v5n3.292.2016

Abstract

This journal discussed the stability analysis of generator excitation control system in type of direct current without and by using controller. The stability Analysis was conducted on absolute stability analysis, relative stability analysis and internal stability analysis. For the absolute stability analysis was demonstrated by using gain margin and phase margin value. In order to get satisfied system performance so that cultivated gain margin value was greater than 6 dB and phase margin value was in ranges from 300 to 600. For the relative stability was shown by the peak value of resonance. The system would be relatively stable if the peak value of resonance range was between 1:10 to 1:50. The system would be internal stable if all closed circle transfer functions from input to internal output was stable. For internal stability indicator was shown by number 0 if the system is internally stable and number 1 if the system was internally unstable. For controllers used consisted of Proportional controller (P), Proportional Integral controller (PI), Proportional Differential controller (PD) and Proportional Integral Differential controller (PID). The controllers were designed with a frequency response approach. The results showed that the voltage response of generator excitation system type direct current with Proportional controller (P), Proportional Integral controller (PI), Proportional Differential controller (PD) and Proportional Integral Differential controller (PID) was stable of absolute, relative and internal.With Proportional controller (P), the voltage response of generator excitation system type direct current had 4.2542 (12.5760 dB) in gain margin value, 50.5290 degrees in phase margin value, 1.2136 (1.6816) in resonance peak value and 0 in internal stability index. With Proportional Integral controller (PI), the voltage response of generator excitation system type direct current had 4.3362 (12.7420 dB) in gain margin value, 49.0000 degrees in phase margin value, 1.2391 (1.8624 dB) in resonance peak value and 0 in internal stability index. With Proportional Differential controller (PD), the voltage response of generator excitation system type direct current had 16.6910 (24.4490 dB)in gain margin value, 54.0000 degrees in phase margin value, 1.1030 (0.8516 dB)  in resonance peak value and 0 in internal stability index. For Proportional Integral Differential controller (PID), the voltage response of generator excitation system type direct current had 8.9451 (19.0320 dB) in gain margin value, 50.0000 degrees in phase margin value, 1.1792 (1.4316 dB) in resonance peak value and 0 in internal stability index.Keyword: Excitation system, absolute stability, relative stability, internal stability, frequency response Abstrak— Jurnal ini membahas tentang analisa kestabilan sistem kendali eksitasi generator tipe arus searah tanpa dan dengan pengendali. Analisa kestabilan yang dilakukan meliputi analisa kestabilan mutlak, analisa kestabilan relatif dan analisa kestabilan internal. Untuk analisa kestabilan mutlak ditunjukkan dengan menggunakan nilai margin penguatan dan nilai margin fasa. agar performansi sistem memuaskan maka diusahakan nilai margin penguatan ini besar dari 6 dB dan nilai margin fasa berkisar antara 300 sampai 600. Untuk kestabilan relatif ditunjukkan dengan nilai puncak resonansi. Sistem akan bersifat stabil relatif jika nilai puncak resonansi berkisar antara  1.10  s/d 1.50. sistem akan bersifat stabil internal jika semua fungsi alih lingkar tertutup dari masukan ke keluaran internal bersifat stabil.  Untuk indikator kestabilan internal ini ditunjukkan oleh angka 0 jika sistem bersifat stabil internal dan angka 1 jika sistem bersifat tidak stabil internal. Untuk pengendali yang digunakan terdiri dari pengendali Proporsional (P), pengendali Proporsional Integral (PI), pengendali Proporsional Diferensial (PD) dan pengendali Proporsional Integral Diferensial (PID). Pengendali – pengendali tersebut dirancang dengan pendekatan tanggapan frekuensi. Hasil yang diperoleh bahwa tanggapan tegangan sistem eksitasi generator tipe arus searah dengan pengendali Proporsional (P), pengendali Proporsional Integral (PI), pengendali Proporsional Diferensial (PD) dan pengendali Proporsional Integral Diferensial (PID) bersifat stabil mutlak, stabil relatif dan stabil internal.Dengan kontroler Proporsional (P), respon tegangan generator eksitasi jenis sistem arus searah memiliki 4,2542 (12,5760 dB) nilai marjin keuntungan, 50,5290 derajat nilai fasa, 1,2136 (1,6816) dalam resonansi nilai puncak dan 0 dalam indeks stabilitas internal. Dengan kontroler Proportional Integral (PI), respon tegangan dari jenis sistem eksitasi generator arus searah memiliki 4,3362 (12,7420 dB) nilai marjin keuntungan, 49,0000 derajat nilai fasa, 1,2391 (1,8624 dB) di resonansi nilai puncak dan 0 dalam stabilitas internal yang indeks. Dengan kontroler Proporsional Differential (PD), respon tegangan dari jenis sistem eksitasi generator arus searah memiliki 16,6910 (24,4490 dB) nilai marjin keuntungan, 54,0000 derajat nilai fasa, 1,1030 (0,8516 dB) di resonansi nilai puncak dan 0 dalam stabilitas internal yang indeks. Untuk Proporsional Integral Diferensial controller (PID), respon tegangan dari jenis sistem eksitasi generator arus searah memiliki 8,9451 (19,0320 dB) nilai margin keuntungan, 50,0000 derajat nilai fasa, 1,1792 (1,4316 dB) di resonansi nilai puncak dan 0 di intern indeks stabilitas.Kata kunci :  sistem eksitasi, kestabilan mutlak, kestabilan relatif, kestabilan internal, tanggapan frekuensi
Analisa Performansi Tanggapan Tegangan Sistem Eksitasi Generator Terhadap Perubahan Parameter Laksono, Heru Dibyo; Febrianda, Adry
JURNAL NASIONAL TEKNIK ELEKTRO Vol 4, No 1: Maret 2015
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (458.411 KB) | DOI: 10.25077/jnte.v4n1.117.2015

Abstract

This journal discusses about performance analysis of generator excitation system voltage response towards parameters changes. Changes in the parameters of the generator excitation system will affect the response voltage generator excitation system performance, in both time domain and frequency domain performances. The performance analysis of the generator excitation system voltage response in both time domain and frequency domain, conduct with the help of Matlab software. For performance in the time domain is consists of error analysis and transient analysis, while for performance in the frequency domain is consists of the open-loop performance and closed-loop performance. The parameters that to be changed are the amplifier gain constant, amplifier time constant, generator gain constant, and generator time constant. The analysis result shows that the performance of the generator excitation system voltage response in both time domain and frequency domain performances is very sensitive towards the changes in the parameters, especially for the changes of amplifier gain constant, the changes of amplifier time constant, the changes of generator gain constant, and the changes of generator time constant.
Perilaku Tegangan Sistem Eksitasi Generator Dengan Metoda Penempatan Kutub Dalam Domain Waktu Laksono, Heru Dibyo; Yulianto, Noris Fredi
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2, No 1: Maret 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (367.411 KB) | DOI: 10.25077/jnte.v2n1.97.2013

Abstract

Dalam sistem tenaga listrik, perilaku tegangan sistem eksitasi merupakan hal yang sangat penting untuk diperhatikan karena dapat mempengaruhi kestabilan tegangan sistem tenaga listrik.  Beberapa penelitian terdahulu menunjukkan performansi perilaku tegangan sistem eksitasi generator yang kurang memuaskan pada titik operasinya. Berdasarkan kondisi tersebut, dilakukan suatu studi dinamik mengenai perilaku tegangan pada sistem eksitasi generator dengan metoda penempatan kutub menggunakan algoritma Bass-Gura, algoritma Ackerman, algoritma Robust Pole Placement dan stabilizer sebagai pembanding nantinya. Dengan menggunakan perangkat lunak Matlab diperoleh bahwa dengan menggunakan metoda penempatan kutub, perilaku tegangan sistem eksitasi generator menunjukkan performansi yang lebih baik dibandingkan performansi perilaku tegangan sistem eksitasi  tanpa metoda penempatan kutub dan dengan stabilizer.Kata Kunci : sistem eksitasi generator,  metoda penempatan kutub, bass-gura, ackerman, robust pole placement, stabilizer 
Simulasi dan Analisa Performansi Buck Converter Dengan Pengendali Dua Derajat Kebebasan Laksono, Heru Dibyo; Saputra, Firmansyah; Ismail, Ismail
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 2: July 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (706.199 KB) | DOI: 10.25077/jnte.v7n2.508.2018

Abstract

DC power supply are commonly used to convert DC voltage level to another level. One type of DC power supply is a buck converter that is used to lower a voltage level. In order to have a proper feedback of voltage output in buck converter system, it will be controlled by a  Two Degrees of Freedom PID Controller. This research aim to analyze the performance of the buck converter that have a Two Degrees of Freedom PID Controller. Two Degrees of Freedom Controller has proportional, integral and derivative control parameters. The simulation of the system is made with the help of software MATLAB. The first simulation and analysis is buck converter system without controller. From the analysis, the desired criteria is obtained . Then a buck converter system was designed. It is controlled using a parallel type of Two Degrees of Freedom PID Controller as well as feedforward, feedback, and filter. From all these types of controllers, it showed that the first order of Proportional Differential Filter (PDF) feedforward type with the value of  Kp = 171, Kd = 0.00545, Tf = 4.88e-07 and the first order of  PDF feedback type with the value of Kp = 171, Kd = 0.00545, Tf = 4.88e-07 was considered as the proper controller that matched with the characteristic. Therefore, it could be concluded that the buck converter controlling system with Two Degrees of Freedom PID Controller could produce a buck converter system with a good performance compared to buck converter without any controllers.Keywords:   Buck converter, Two Degrees of Freedom PID Controller, control system, time domain performance.
Evaluasi Kestabilan Peralihan Mesin Tunggal dengan Metode Rungge Kutta Orde 4 (Studi Kasus : Sistem Kelistrikan Sumatera) Dibyo Laksono, Heru; Rizki Ramadhan, Alrino
JURNAL NASIONAL TEKNIK ELEKTRO Vol 3, No 1: Maret 2014
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (650.462 KB) | DOI: 10.25077/jnte.v3n1.59.2014

Abstract

The journal discusses the evaluation and calculation of the termination time of the critical electrical system stability studies Sumatra through the transient stability by using the Runge-Kutta method Order 4. For this type of disorder transition used is a three-phase symmetrical disorder with the help of MATLAB software. The calculation result shows that the value of the smallest critical time termination occurs between PLTGU Belawan - GI Ombilin Binjai and power plant - GI Batusangkat at 0:24 seconds. While the most critical time of termination occurs at a power plant Pauh Limo - GI Indarung at 1:14 seconds.Keywords : Stabilitas peralihan, runge – kutta orde 4,  waktu kritis pemutusan  .  AbstrakJurnal ini membahas tentang evaluasi dan perhitungan waktu pemutusan kritis dari sistem kelistrikan Sumatera melalui studi kestabilan peralihan dengan menggunakan metoda Runge-Kutta Orde 4. Untuk jenis gangguan peralihan yang digunakan adalah gangguan tiga fasa simetris dengan bantuan perangkat lunak Matlab. Hasil perhitungan diperoleh bahwa nilai waktu pemutusan kritis terkecil terjadi antara PLTGU Belawan – GI Binjai dan PLTU Ombilin – GI Batusangkat sebesar 0.24 detik. Sedangkan  waktu pemutusan kritis terbesar terjadi pada PLTG Pauh Limo – GI Indarung sebesar 1.14 detik.Kata Kunci : Stabilitas peralihan, runge – kutta orde 4,  waktu kritis pemutusan    
Memperbaiki Tegangan dan Rugi–rugi Daya pada Sistem Transmisi dengan Optimasi Penempatan Kapasitor menggunakan Algoritma Genetika Yunus, Syukri; Laksono, Heru Dibyo; Nidya, Putri
JURNAL NASIONAL TEKNIK ELEKTRO Vol 5, No 2: Juli 2016
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (492.843 KB) | DOI: 10.25077/jnte.v5n2.291.2016

Abstract

Electric power system is said to have a high degree of reliability if the system is able to provide a supply of electrical energy required by consumers continuously. Power loss that occurs in line resulting voltage drop on the line and cause a loss due to the decreasing reliability of the system to supply power to the load. To reduce the power loss in the line do installation of capacitors. Installation of capacitors conducted by calculating the position of the placement and size, so that placement of capacitors that do can be optimized to reduce losses that occur. Optimal methods are quite effective is algorithm genetics. In this method, capacitor placement is done with the chromosome leads to the selection obtained. The best results will be obtained from a chromosome that contains a condition that there is optimum placement of capacitors that can minimize power loss that occurs in the channel as well as minimize the amount of use of the capacitor. The comparison can be done by using Newton Raphson power flow between before and after forging capacitor.Keywords : Power losses, voltage, algorithm genetics, capacitors, chromosomeAbstrak— Suatu sistem tenaga listrik dikatakan memiliki tingkat keandalan yang tinggi apabila sistem tersebut mampu menyediakan pasokan energi listrik yang dibutuhkan oleh konsumen secara kontinyu. Rugi–rugi daya yang terjadi pada saluran mengakibatkan turunnya tegangan pada saluran dan menyebabkan kerugian karena semakin berkurangnya keandalan sistem dalam menyalurkan listrik ke beban. Untuk mengurangi terjadinya rugi–rugi daya pada saluran dilakukan pemasangan kapasitor. Pemasangan kapasitor dilakukan dengan memperhitungkan posisi penempatan serta ukurannya, agar penempatan kapasitor yang dilakukan dapat optimal dalam mengurangi rugi–rugi yang terjadi. Metode optimasi yang yang cukup efektif adalah algoritma genetika. Pada metode ini, penempatan kapasitor dilakukan dengan mengarah pada pemilihan kromosom yang diperoleh. Hasilnya akan diperoleh kromosom terbaik dari sebuah populasi yang ada yang berisi kondisi optimum penempatan kapasitor yang dapat memperkecil rugi–rugi daya yang terjadi pada saluran sekaligus meminimalisir banyaknya penggunaan kapasitor. Perbandingan yang bisa dilakukan dengan menggunakan aliran daya Newton-Raphson antara sebelum dan sesudah penempatan kapasitor.Kata Kunci : Rugi-rugi daya, Tegangan, Algoritma genetika, Kapasitor, Kromosom.
Evaluasi Pola Tingkah Laku Tegangan Sistem Eksitasi Generator Dengan Metoda Penempatan Kutub Menggunakan Algoritma Bass–Gura Laksono, Heru Dibyo; Yulianto, Noris Fredi
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2, No 2: September 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (439.493 KB) | DOI: 10.25077/jnte.v2n2.70.2013

Abstract

In power systems, the behavior patterns of excitation system voltage is very important to note because it can affect the voltage stability of the power system. Several previous studies showed performance behavior pattern generator excitation system voltage is less than satisfactory at the point of operation. Under these conditions, conducted a study of the patterns of behavior of dynamic voltage generator excitation system with pole placement method using the Bass-Gura algorithm. With the help of information obtained by Matlab software, that behavior pattern generator excitation system voltage indicates better performance compared to the performance of the behavior patterns of excitation system voltage without the pole placement method.Keywords: generator excitation systems, pole placement method, bass-Gura, performance AbstrakDalam sistem tenaga listrik, pola tingkah laku tegangan sistem eksitasi merupakan hal yang sangat penting untuk diperhatikan karena dapat mempengaruhi kestabilan tegangan sistem tenaga listrik.  Beberapa penelitian terdahulu menunjukkan performansi pola tingkah laku tegangan sistem eksitasi generator yang kurang memuaskan pada titik operasinya. Berdasarkan kondisi tersebut, dilakukan suatu studi dinamik mengenai pola tingkah laku tegangan pada sistem eksitasi generator dengan metoda penempatan kutub menggunakan algoritma Bass-Gura. Dengan bantuan perangkat lunak Matlab diperoleh informasi, bahwa pola tingkah laku tegangan sistem eksitasi generator menunjukkan performansi yang lebih baik dibandingkan performansi pola tingkah laku tegangan sistem eksitasi tanpa metoda penempatan kutub.Keywords: generator excitation systems, pole placement method, bass-Gura, performance  
Co-Authors . Darwison ., Mazues A, Wayu Diafridho A, Wayu Diafridho Abdul Rajab Aditya Putra Pratama Adry Febrianda Aidil Danas Aidil Danas Alrino Rizki Ramadhan Amirul Luthfi, Amirul Asri Astia Ningsih Asri Astianingsih Astri Astia Ningsih Avif Tiftazani Chatarina Umbul Wahyuni Danar Adi Laksono Danas, Aidil Danas, Aidil Doohan Haliman Fahreza, Rahmad Farizi, AL Febrianda, Adry Firmansyah Saputra Fitrilina Fitrilina Fitrilina Fitrilina, Fitrilina GANESHA Gunawan, Eko Amri Haliman, Doohan Hanalde Andre Handayani, Yanolanda Suzantry Hasanah, Mardini Ismail Ismail Ismail, Ismail Latif , Melda M. Irmansyah M. Reza Permana Mardini Hasanah Mazues . Melda Latif Mohamad Hanif Hakim Muharam , Mumuh Muhardika Muhardika Mumuh Muharam Mumuh Muharram Mumuh Muharram N. Riska Nidya, Putri Noris Fredi Yulianto Noris Fredi Yulianto Novizon, Novizon Permana, M. Reza Pinto Anugrah Pratama, Rizki Wahyu Putra, Gema Azzanni Putra, Ravi Shidqi Putri Nidya Putri, Dhea Rahmadani Qatrunnada, Rusvaira Rahmad Fahreza Rahmadani Putri , Dhea Rahmadani, Fauzi Rahmadi Kurnia Rahman Ikhlas Rahmayane Rahmayane Ramadhani, Salisa 'Asyarina REDAKSI Redaksi Reri Afrianita Reri Afrianita Retno Ningsih , Fina Ridza Azri Ramlee Rika Ampuh Hadiguna Riko Nofendra Riko Nofendra Riska, N. Rizki Ramadhan, Alrino Rizki Wahyu Pratama Rohadatul ‘Aisya Rusvaira Qatrunnada Rusydi, Muhammad Ilhamdi Salim, Suci Maretta Saputra, Firmansyah Shidqi Putra, Ravi Subhan Petrana Surapati, Alex Syafii . Syafii . Syarkawi Syamsuddin Syukri Yunus Tiftazani, Avif Tomas, Micko Untari, Rahayu Trisetyowati Wahyu Pratama , Rizki Wayu Diafridho A Wayu Diafridho A Widi Adriana , Anisa Wira Hidayat bin Mohd Saad Yulianto, Ardhian Agung Yulianto, Noris Fredi Yulianto, Noris Fredi Zaini, Zaini