Jurnal Civil Engineering Study (JCES) contains writings about applications in the field of Civil Engineering. This application may come from all branches of civil engineering, be it structural, geotechnical, construction management, hydrology, transportation, and civil engineering informatics. So this application is not only about the business of building a building project, but also makes it possible to model a shape with the help of software.
Articles 138 Documents
Analisis Pembengkakan Biaya pada Proyek Asrama Minhajul Abidin di Barabai Ghina Nafisa; Ruliana Febrianty; Muhammad Gunawan Perdana
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRACT Deviations between initial estimates and final expenditures remain a recurring challenge in building projects. This study quantifies the magnitude of these deviations and their distribution across work categories in the Minhajul Abidin Islamic Boarding School dormitory construction project in Barabai, Indonesia. A descriptive quantitative design was applied to documentary data comprising the Engineer Estimate (EE)/Cost Budget Plan (RAB), initial contract, monthly progress reports, Contract Change Order, Addendum I, and Mutual Check 100% (MC-100). Eight work categories were harmonized and evaluated using cost variance (CV = actual cost - budgeted cost) and the cost overrun percentage. The official total EE was IDR 1,618,544,235.98, while the total MC-100 was IDR 1,622,516,756.76, resulting in an overrun of IDR 3,972,520.78 or 0.25%. Preliminary works had the highest proportional overrun (54.26%), while foundation and reinforced concrete works generated the largest nominal variance (IDR 100,536,950.84; 13.51%). The other five work categories recorded cost savings that offset most of these increases. The project-level deviation was relatively small, but monitoring by work category remains important because aggregate totals can mask substantial internal reallocations.
Degradation Model of Bamboo Service Life as Reinforcement of Rigid Pavement Slabs on Soft Soils Agus Setiawan; Lasmito; Mohammad Mukhdif Al-Afghoni; Vanezia Yuniar Caroline
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The use of bamboo as an alternative reinforcement for rigid pavement slabs on soft soil offers potential for sustainable construction and the utilization of local materials. However, its performance may be affected by the degradation of mechanical properties and bamboo–concrete bond. This study evaluates the changes in bamboo tensile strength, bamboo–concrete bond strength, and the structural response of bamboo-reinforced pavement slabs during 1, 3, and 6 months of observation. The experimental program consisted of tensile tests on V-notched bamboo strips, pull-out tests, and progressive loading tests on concrete slabs reinforced with bamboo. The loading was increased progressively to approximately 8 kN. The results showed that bamboo tensile strength remained relatively stable up to the third month and decreased by 2.1% at the sixth month. The bamboo–concrete bond strength decreased from 0.341 MPa at the first month to 0.256 MPa at the sixth month, representing a reduction of 24.9%. At the structural level, the maximum slab load decreased from 8.8 kN to 6.5 kN, while the maximum deflection increased from 11.20 mm to 18.20 mm. The secant stiffness decreased by 54.6%. The transition of failure characteristics from initial flexural cracking to wider bond-slip cracking indicates that the reduction in slab performance is closely associated with the deterioration of load transfer at the bamboo–concrete interface. These findings indicate that the assessment of bamboo-reinforced pavement slabs should consider bamboo–concrete bond degradation as an important parameter governing structural performance over the service period.
Analysis of the Effect of Building Structural Asymmetry on Earthquake-Induced Deformation Based on SNI 1726:2019 Azzahra Valentynna Nathania Putri Azzahra; Moh Arif Bakhtiar Efendi Arif; Nur Huda Huda; Hendramawat Aski Safarizki; Donny July Prasetyo; Ruliana Febrianty; Rasio Hepiyanto; Achmad Muzaky; Arif Hidayat; Muhammad Fakhrul Rozi; ⁠Aminarti Laela
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The Kauman Baru Public Health Center Building in Ponorogo Regency has an asymmetrical floor plan configuration, making it potentially susceptible to greater deformation under earthquake loading. This study aims to analyze the structural deformation of the building using the response spectrum method based on SNI 1726:2019. A quantitative research method was employed using secondary data, including construction drawings, technical data, and material specifications. Structural modeling and analysis were carried out using SAP 2000 software. The analysis results indicate that the maximum structural deformation due to earthquake loading is 0.0187 m, while the allowable deformation limit according to SNI 1726:2019 is 0.06 m. Therefore, the structural deformation remains below the allowable limit, indicating that the Kauman Baru Public Health Center Building in Ponorogo Regency satisfies the deformation requirements and is considered safe against earthquake loading.
Superstructure Performance Analysis of a School Building in Ponorogo Using the Response Spectrum Method Daffa Mohammad Rosul; Laily Fatmawati; Moh Arif Bakhtiar Efendi
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The construction of the new Muhammadiyah Integrated Elementary School (SDMT) building in Ponorogo is constrained by limited land availability, requiring a three-story structure with adequate capacity to resist gravity and seismic loads. This study aims to design and evaluate the structural performance of the building's superstructure, including the roof structure, slabs, beams, and columns. Structural analysis and design were conducted in accordance with SNI 1726:2019, SNI 1727:2020, SNI 2847:2019, and SNI 1729:2020, while seismic performance was evaluated using the response spectrum method. The results show that the roof structure satisfies the required safety criteria using CNP 150 × 50 × 20 × 3 purlins and IWF 300 × 150 × 6.5 × 9 steel roof trusses. The effective seismic weight reached 1,171,468.86 kg, with an equivalent static base shear of 202,502.85 kg. The structural components fulfilled the design requirements, including reinforced concrete slabs with thicknesses of 10 cm, 13 cm, and 15 cm, primary beams measuring 55 × 30 cm, and primary columns measuring 50 × 40 cm. Overall, the proposed superstructure satisfies the requirements for strength, stiffness, stability, and compliance with applicable Indonesian design standards.
Structural Redesign of the Myze Waingapu Hotel Superstructure Due to the Addition of One Floor Elva Dwi Rahmandani; Seno Aji; Nur Huda
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The expansion of the Myze Waingapu Hotel from four to five stories requires a comprehensive structural evaluation due to significant changes in load distribution. This study aims to evaluate the structural capacity, verify the safety of structural elements based on the latest SNI standards, and provide technical recommendations. Structural modeling of the steel roof, floor slabs, and reinforced concrete (beams and columns) was performed using SAP2000 software. The seismic load analysis applied the response spectrum method in accordance with SNI 1726:2019, with an effective seismic weight of 30,579.903 kN. The results show that the WF-profile steel roof structure with a 32° slope meets the strength and stability requirements. The dynamic base shear in the X direction (3,096.093 kN) and Y direction (3,098.616 kN) meet the standards because their values exceed the equivalent static shear forces. The design of the reinforced concrete elements was also found to be safe in accordance with SNI 2847:2019 guidelines. In conclusion, the design of this hotel’s upper structure provides a feasible, safe, and efficient technical solution for implementation.
Structural Analysis of The UMY Admissions Building Vertical Expansion Using Special Moment Resisting Frames Hendro Susilo; Nur Huda; Iin Ernawati Ernawati; Linda Fatikha Wulandari; Muhammad Koderi H.W.; Muhammad Gunawan Perdana; Samsul Arif; Zahira Afsahinniswah; Fatchur Roehman; Satrio Adi Wahyu Nugroho; Alfin Sahila
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The Admission Building of Universitas Muhammadiyah Yogyakarta is a three-story structure developed into four stories due to increasing space demands. This vertical expansion increases gravity and lateral loads, necessitating a superstructure redesign to ensure structural safety. The design complies with SNI 1729:2020 (steel), SNI 2847:2019 (concrete), SNI 1727:2020 (loading), and SNI 1726:2019 (seismic). Structural analysis via SAP2000 v22 utilized 25 MPa concrete, BJ 37 steel, and 400 MPa deformed reinforcement. Results indicate the roof structure employs IWF 300.150.6,5.9 mm, HWF 400.200.8.13 mm, and regel 250.125.6.9 steel trusses with CNP 150.75.20.4,5 mm purlins. Floor slabs are designed with a thickness of 130 mm, standard roof slabs at 100 mm, and water tank slabs at 150 mm. The building implements a Special Moment Resisting Frame (SMRF) system. The main beam (B1) dimension is 300×700 mm, while main columns utilize 600×600 mm (K1) and 400×600 mm (K2) sections. All analytical outcomes demonstrate that the proposed superstructure satisfies the strength, ductile stiffness, and functional stability criteria in accordance with applicable standards.
The Effect of Using Rice Husk Filler on the Soundproofing Ability of Concrete Blocks Muhammad Ikhsan Aji Suhendarno; Rendi Gusta W; Setiyo Daru C; Ahmad Alfadhilah; Ainun Nurin Sharvina; Robiatul Adawiyah; Rio Rahma Dhana; Sabrina Nur Aulia; Muhammad Ali Murtadho; Rosyiq Firstyo Nafis; Muhamad Khayatul Akbar
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The advancement of construction technology has encouraged the development of environmentally friendly building materials through the utilizations of agricultural waste, one of which is rice husk as an additive in concrete blocks. This study aims to analyze the effect of rice husk addition on the density, compressive strength, and sound insulation performance of concrete blocks. Rice husk was incorporated at four different proportions: 0%, 1%, 2%, and 3%. The results indicate that increasing the rice husk content reduced the density of the concrete blocks from 2.282 g/cm³ at 0% to 1.857 g/cm³ at 3%. Similarly, the compressive strength decreased from 18.47 MPa to 5.88 MPa; however, all mixtures satisfied the Indonesian National Standard (SNI) minimum compressive strength requirement of 2.5 MPa. Sound insulation testing revealed that concrete blocks containing rice husk exhibited superior acoustic performance compared to conventional concrete blocks, with sound intensity reductions of 6%, 23%, 31%, and 36% for the 0%, 1%, 2%, and 3% rice husk mixtures, respectively. These findings demonstrate that rice husk has significant potential as a sustainable additive for producing lighter concrete blocks that maintain the required mechanical strength while providing enhanced sound insulation, making them a promising environmentally friendly construction material.
Seismic Response Comparison of Tidar Regional Hospital Using Equivalent Static, Response Spectrum, and Time-History Methods Agustinus Sungsang Nana Patria; Pramesta Armanisag Pangestuti; Rahma Amalia Sinatria
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Earthquake analysis methods affect structural response and member demands. This study compares equivalent static, response spectrum, and time-history analyses of the Aster Inpatient Building at Tidar Regional Public Hospital in Magelang, a six-story reinforced-concrete structure on site class SD. The ETABS model uses a special moment-resisting frame system. Time-history analyses use the Sanriku Iwate 2011, Fukushima Chiba 2011, and Cook Strait 2013 records after spectral matching. The comparison parameters include base shear, modal characteristics, lateral displacement, stability coefficients, and moments and shear forces in selected members. The largest X-direction base shear occurred under the Sanriku record at 6,259.332 kN, while the largest Y-direction value occurred under response spectrum analysis at 5,771.447 kN. The Fukushima and Cook Strait responses were approximately 18–19% of the equivalent static values, indicating that scaling equivalence should be checked. Sanriku produced beam and column moments of 1,267.019 kN·m and 2,668.113 kN·m, respectively. The equivalent static and response spectrum methods produced larger reported lateral displacements than the three time-history records. The findings indicate that global and local responses should be considered together. Final assessment of interstory drift and stability requires consistent displacement definitions, spectrum parameters, units, and scale factors.