cover
Contact Name
Pradipta Nandi Wardhana
Contact Email
teknisia@uii.ac.id
Phone
-
Journal Mail Official
teknisia@uii.ac.id
Editorial Address
-
Location
Kab. sleman,
Daerah istimewa yogyakarta
INDONESIA
Teknisia
ISSN : 08538557     EISSN : 27460185     DOI : 10.20885/teknisia
Core Subject : Engineering,
Jurnal Teknisia terbit pertama kali pada bulan April 1996. Pada awal berdirinya, Jurnal Teknisia merupakan jurnal ilmiah berkala yang diterbitkan tiga kali setahun oleh Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia, Daerah Istimewa Yogyakarta yang berisi artikel-artikel bidang teknik sipil, teknik lingkungan, dan arsitektur.
Arjuna Subject : -
Articles 137 Documents
ANALISIS ANGKUTAN SEDIMEN DASAR (BED LOAD) PADA SALURAN IRIGASI MATARAM YOGYAKARTA Anggi Hermawan; Erwin Nur Afiato
TEKNISIA Vol. XXVI, No. 1, Mei 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss1.art3

Abstract

In the last decade, the problem that has occurred in the Yogyakarta Mataram irrigation channel is the occurrence of sedimentation in the channel. This has an impact on reducing the cross-sectional discharge capacity of the canal and resulting in the supply of irrigation discharge to agricultural areas to be not optimal, so that agricultural productivity in the Mataram Irrigation Area will also not be optimal. The sediment transport (bed load) that occurs in an open channel can be approached using the empirical equation, including the Einstein, Meyer - Peter Muller and Frijlink equations. Sediment transport events that occur in the channel are stated based on the magnitude of the flow shear stress which exceeds the critical shear stress of the sediment particles. The quantity of sediment transport in the channel is stated on the logarithmic curve of the relationship between the froude number (fr) to the sediment transports (qb). The Curve  explains that the increase in the froude number (fr) that occurs on each section of the channel  will be directly proportional to the increase in the quantity of transport sediment (qb). The largest sediment transport occurred at the site of the Gambang and Nambongan channel section with a prediction of sediment transport of 3.57 m3/day and 3.67 m3/day, respectively. Thus, the potential for sediment transport that will settle in the downstream area is 3.67 m3/day.
STUDI ANALISIS KAPASITAS NOMINAL PELAT KOMPOSIT BETON-DEK BAJA METODE ULTIMIT, TEGANGAN KERJA DAN SDI-ANSI 2017 Hariadi Yulianto
TEKNISIA Vol. XXVI, No. 1, Mei 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss1.art1

Abstract

Today, the most efficient slab construction method is the concrete-steel deck composite slab because there is no need to remove the deck after the concrete casting process. Nevertheless, reinforced concrete standard code (SNI 2847:2019) not emphasized a specific method to calculate the concrete-steel deck slab's nominal capacity. The code is embraced by the plastic method analysis, which is calculated the nominal capacity of the structure on the ultimate condition. However, several laboratory tests reveal a slip behavior between the concrete and steel deck before the slab reaches its ultimate condition. Therefore, alternative methods are needed to analyze the nominal capacity of concrete-steel deck slab. This study compares three different nominal capacity analysis methods to a laboratory test result. Those methods are ultimate, working stress, and SDI-ANSI (2017). The average error value of those three methods compared to laboratory test results in 35,57%, 9,48%, and -10,31% for ultimate, working stress, SDI-ANSI (2017) consecutively.it can be concluded the working stress method is the most accurate. However, SDI-ANSI (2017) is the conservative one, while the ultimate method is not recommended to analyze the concrete-steel deck slab's nominal capacity.
EVALUASI KONDISI LINGKUNGAN DAN SARANA PENYELAMATAN PADA GEDUNG PERKULIAHAN TERHADAP BAHAYA KEBAKARAN Fadillawaty Saleh; Sinta Rizky Amalia; Hakas Prayuda; Lilis Tiyani; Bella Lutfiani Al Zakina
TEKNISIA Vol. XXVI, No. 1, Mei 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss1.art4

Abstract

Many aspects must be considered in the building's design so that the construction is sturdy and can be used according to its function. An important aspect that is often overlooked is the aspect of fire safety. This study aims to evaluate environmental conditions and safety facilities in buildings against fire hazards. The buildings reviewed are the Postgraduate Building, E6, E7, and F3 of the Muhammadiyah University of Yogyakarta. The research method used in this research is a qualitative approach, and the primary data is obtained by direct observation in the field and interviews with the person in charge of the building. This study indicates that the environmental conditions of the postgraduate building, E6, E7, and F3, are not in good condition because each building gets a condition value of 51.67%; 50.56%; 52.22%; and 50%. The rescue facilities in the postgraduate building, E6, and E7 are good; although there are some shortcomings, the value of the condition of each building is 85.98%, 87.41%, and 87.41%. The rescue facility in the F3 building is quite good, with a condition value of 65.81%.
PENGEMBANGAN PERANGKAT LUNAK PERANCANGAN LAPIS ULANG PERKERASAN LENTUR BERDASARKAN MANUAL BINA MARGA 2017 Kushari, Berlian; Hidaya, Nur Robbi
Teknisia Vol. XXVI, No. 2, November 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss2.art5

Abstract

The Benkelman Beam method is used to design overlay thickness on a flexible pavement based on its maximum rebound deflection representing its structural capacity. This method has been adopted in the 2017 Bina Marga Design Manual applicable for Indonesian road design since June 2017. This research was aimed to develop a tool that can facilitate rebound deflection data analysis and overlay thickness design based on the overlay design curves adopted in the Bina Marga guide. Visual Basic 6.0 was used as the environment for the development. In addition to the standard curves, the tool added four intermediate curves corresponding to the design load of 7.5x106, 3.5x106, 1.5x106, and 0.75x106 ESALs to enable more economical designs. Furthermore, a manual overlay procedure was conducted using overlay data from Sampaan – Singosaren, Kowangan – Maron, and Imogiri Barat road sections to validate the usability of the developed tool. The validation showed an acceptable difference of less than 2% between results obtained from the software and the manual calculations.
RASIO KEKAKUAN LENTUR (FLEXURAL STIFFNESS RATIO) ELEMEN BETON AKIBAT GEMPA BERDASARKAN ANALISIS DINAMIK STRUKTUR SINGLE DEGREE OF FREEDOM (SDOF) Widodo Pawirodikromo; Anggit Mas Arifudin; Dewi Ayu Harjani
TEKNISIA Vol. XXVI, No. 2, November 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss2.art6

Abstract

Modeling the effective stiffness of reinforced concrete elements for structural analysis is an important problem and needs to be solved. The effective stiffness is then expressed in terms of the average flexural stiffness ratio Ck. whose value has been determined by Codes. Previous studies have shown that the stiffness ratio is assumed/stated to be strength-dependent. Based on this statement, research on the flexural stiffness ratio Ck of reinforced concrete elements through dynamic analysis of the SDOF structure was carried out. The SDOF structural model used has a vibration period T = 0.48 sec. The dynamic load used is 50 earthquake records consisting of 3-groups of frequency content (low, moderate, high). The dynamic analysis that was carried out has accommodated the inelastic responses whose behavior follows Modified Takeda hysteretic loops. The study results showed that the maximum response of the structure generally occurred in the strong middle part of the earthquake recording or the period of the effective duration of D595. The main finding in this study is that the strength dependent of flexural stiffness is proven. The relationship between the average flexural stiffness ratio Ck and peak ground acceleration of PGA can be mathematically expressed in the equation Ck = -0.981.PGA + 0.822. The relationship is negative, meaning that the higher the PGA value, the smaller the Ck value with a correlation coefficient of R = 0.635 (moderate correlation). The Ck value negatively correlates with the drift ratio and damage index, DI.
STUDI PENAMBAHAN STRUKTUR BETON BERTULANG MENJADI KOMPOSIT DENGAN BAJA BERGELOMBANG PADA OVERPASS PUCUNG LOR KROYA Raden Aufa Dhia Anggara; Ashar Saputra
TEKNISIA Vol. XXVI, No. 2, November 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss2.art1

Abstract

The construction of a nonlevel railway crossing in Pucung Lor Kroya was aimed to improve safety and smooth traffic between railways and roads. Increasing frequency of railways through the Double Track Railway Project of South Java demands a fast pace construction of railway crossing without disrupting any railway traffic. So, the overpass structure will be built using Corrugated Mortar Busa Pusjatan (CMP) technology with Corrugated Steel Plate (CSP) on a curve structure 1 (P1) with a 25-meter span and curve structure 2 (P2) with a 12-meters span. When construction began, planners added reinforced concrete layers until composite with CSP to increase structural capacity and became structural protectors if CSP yielded or corrosions. Overpass modeling was done using MIDAS Civil 2019 based on finite element 3D to check strength capacity and service limits. The addition of reinforced concrete structures to composites with CSP is also compared to the non-composite design of CMP Pusjatan to see the effect on internal forces, stress, and deflection of CSP although the stress on foam mortar. Based on the results, the composite design overpass analysis satisfies compression-bending and shearing capacity checks based on Ultimate Limit States (ULS-PBKT) and service limit based on Serviceability Limit State (SLS-PBL). The addition of reinforced concrete to composite with CSP increases safety factor value because CSP stresses are lower than non-composite designs. The potential collapses from foam mortar can also be reduced as the structure becomes rigid.
ANALISIS PERBANDINGAN PRODUKTIVITAS PEKERJAAN FONDASI DANGKAL DENGAN MATERIAL BLOK BETON DAN PRODUKTIVITAS PEKERJAAN SESUAI SNI 2836:2008 Hari Nuryanto; Setya Winarno
TEKNISIA Vol. XXVI, No. 2, November 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss2.art2

Abstract

The use of concrete block material instead of rubble stone on shallow foundation work has many advantages. One aspect that needs to be studied is its workforce productivity. This paper aims to elaborate workforce productivity on shallow foundation work with concrete block material and compare its result to Standard of SNI 2836:2008. Data are collected from construction project which has site-wide construction in Krandon and site-narrow construction in Keringan. The method of data collection has been done by direct investigation from the beginning to the end of the foundation project and complemented by photo and video. These findings have shown that workforce productivity on shallow foundation work with concrete block material both in wide-site and narrow site construction is higher than that of SNI Standards, i.e. 48,87% and 7,14% higher, respectively. Moreover, the productivity rate tends to increase due to the learning effect and adaptation on this foundation work done repetitively. There is a learning curve: y=0,1271.ln(x)+0,4818, in which y=productivity rate and x=work session.
EVALUASI FASILITAS BAGI PENYANDANG DISABILITAS DI STASIUN YOGYAKARTA Aisyah Nur Jannah; Prayogo Afang Prayitno; Prima Juanita Romadhona
TEKNISIA Vol. XXVI, No. 2, November 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss2.art3

Abstract

Yogyakarta Station is a railway station located in Yogyakarta City. As a transportation mode transfer point, the station must be inclusive for all train passengers, including passengers with disabilities. An inclusive railway station will be accomplished by providing station facilities that accommodate accessibility for passengers with disabilities. This study aims to evaluate the facilities for passengers with disabilities at Yogyakarta Station. By understanding the evaluation, railway operators and governments will create specific improvements that would make the station more inclusive. The facilities are following the Minister of Transportation Regulation Number PM 98 of 2017 concerning Providing Accessibility to Public Transportation Services for Service Users with Special Needs. This study uses the IPA (Importance Performance Analysis) method obtained through observation and questionnaires. The result shows that based on 15 (fifteen) facilities evaluated, all facilities are available in Yogyakarta Station except the guide block to the counters and toilets, information in Braille letters, ticketing counters/special ticketing counters, and information/customer service rooms which accessible easily. In addition, based on the IPA method, improving facilities for passengers with disabilities at Yogyakarta Station should be prioritized for ready-to-use wheelchair facilities, access to and from passengers in multi-story buildings, and toilet access.
THE USE OF AN INERTER FOR BASE-ISOLATION SYSTEM IN A SINGLE-DEGREE-OF-FREEDOM STRUCTURE Predaricka Deastra
TEKNISIA Vol. XXVI, No. 2, November 2021
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol26.iss2.art4

Abstract

This paper presents seismic performance of a single-degree-of-freedom (SDOF) structure equipped with a base isolation system (BIS). Common BIS employs rubber material to provide lateral flexibility in order to minimize the transmitted energy induced by the ground motion to the structure. The concept is to lower the structural natural frequency such that it falls far below the pre-dominant frequency of most earthquakes. A similar effect can also be achieved by using a device called inerter, a two-terminal device generated forces proportional to the relative acceleration between its two terminals. Instead of reducing stiffness, inerter amplifies the theoretical mass of the structure without significantly increase its physical mass. It is because, depending on the inertance-generation mechanism, an inerter is capable of generating inertance – a constant ratio of forces and relative accelerations of the inerter – several times higher than its physical mass. In this paper, the effectiveness of inerter for use as a BIS is compared to the common BIS concept. The results show that, for a similar natural frequency level, a BIS with inerter has narrower response around the resonance in the frequency domain. Furthermore, in the time domain analysis, the structure with an inerter has a lower response compared to the structure with a traditional BIS when subjected to a long-period earthquake ground motion
STUDI KINERJA CAMPURAN ASPAL PORUS DENGAN PENAMBAHAN BAHAN ADDITIVE REDISET LQ-1106 Eza Marizka; Miftahul Fauziah; Subarkah
TEKNISIA Vol 27 No 1 (2022): Teknisia
Publisher : Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20885/teknisia.vol27.iss1.art2

Abstract

Porous asphalt is an asphalt mixture with high porosity to reduce the potential waterlogging and increase the roughness of the road surface. However, porous asphalt mixture has shortcomings in terms of strength and durability. This paper presents laboratory testing results of the effect of adding Rediset LQ-1106 additive on the performance of a porous asphalt mixture. The research was started with the determination of the optimum asphalt content. Then, the test object was made with Rediset LQ-1106 using variations in 0%, 1%, 2%, and 3% of the optimum asphalt content and carried out the Marshall test, Immersion Test, Indirect Tensile Strength, Tensile Strength Ratio, and Wheel Tracking. The test results show that adding 1% of Rediset LQ-1106 resulted in the optimum performance of porous asphalt compared to other grade additions. This performance is evidenced by the increase in the mixture stability value by 18.62%, the Indirect Tensile Strength value of 20.14%, the dynamic stability value of 35.88%, and the most negligible deformation speed compared to porous asphalt, which does not use Rediset LQ-1106. However, the Index Retained Strength, and Tensile Strength Ratio tests did not significantly increase performance.

Page 9 of 14 | Total Record : 137