cover
Contact Name
Syafii
Contact Email
jnte@ft.unand.ac.id
Phone
-
Journal Mail Official
Syafii@ft.unand.ac.id
Editorial Address
-
Location
Kota padang,
Sumatera barat
INDONESIA
JURNAL NASIONAL TEKNIK ELEKTRO
Published by Universitas Andalas
ISSN : 23022949     EISSN : 24077267     DOI : -
Core Subject : Engineering,
Jurnal Nasional Teknik Elektro (JNTE) adalah jurnal ilmiah peer-reviewed yang diterbitkan oleh Jurusan Teknik Elektro Universitas Andalas dengan versi cetak (p-ISSN:2302-2949) dan versi elektronik (e-ISSN:2407-7267). JNTE terbit dua kali dalam setahun untuk naskah hasil/bagian penelitian yang berkaitan dengan elektrik, elektronik, telekomunikasi dan informatika.
Arjuna Subject : -
Articles 610 Documents
Keandalan Jaringan Tegangan Menengah 20 kV di Wilayah APJ Padang PT.PLN (Persero) Cabang Padang Ali Basrah Pulungan; Sukardi .; Dahlan Prinando Tambun
JURNAL NASIONAL TEKNIK ELEKTRO Vol 1 No 1: September 2012
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (922.475 KB) | DOI: 10.25077/jnte.v1n1.62.2012

Abstract

Sistem distribusi sebagai sistem penyaluran tenaga listrik yang langsung berhubungan dengan pelanggan harus memperhatikan tingkat keandalannya yaitu dapat menyuplai tenaga listrik ke konsumen secara kontiniu.Tingkat keandalan suatu system dapat ditentukan dengan menghitung SAIFI (SistemAvarage Interruption Frequency Index) dan SAIDI (Sistem Avarage Interruption Duration Index) yaitu frekuensi pemadaman dan lama pemadaman yang dialami system distribusi dalam rentang waktu tertentu.Penelitian ini bertujuan menghitung  indeks keandalan jaringan tegangan menengah 20 kV di Wilayah Area Pelayanan Jaringan (APJ) Padang.Perhitungan indeks keandalan didasarkan pada indeks keandalan berbasis sistem yaitu SAIFIdan SAIDI. Berdasarkan perhitungan dan analisis indeks keandalan berbasis sistem  pada jaringan tegangan menengah Area Pelayanan Jaringan (APJ) Padang tahun 2009, maka dapat disimpulkan bahwa indeks keandalan berbasis system pada Area Pelayanan Jaringan (APJ) Padang termasuk tingkat keandalan rendah.Kata kunci: Keandalan, SAIFI, SAIDI, APJ Padang
Kontrol Posisi Robot Mobil Menggunakan Logika Fuzzy dengan Sensor Ultrasonik Darwison .; Ilhamdi Rusydi; Rico Fajri
JURNAL NASIONAL TEKNIK ELEKTRO Vol 1 No 1: September 2012
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3862.935 KB) | DOI: 10.25077/jnte.v1n1.63.2012

Abstract

Penelitian ini bertujuan membuat kontrol posisi robot mobil dengan menggunakan sensor ultrasonik sebagai pengukur jarak dan encoder untuk penghitung kecepatan robot mobil. Dengan menerapkan metoda logika fuzzy akan membuat pergerakan servomotor DC dari robot mobil bergerak lebih halus. Logika fuzzy merupakan suatu hubungan ketidakpastian sesuatu yang tidak mempunyai suatu batas jelas kedalam suatu persamaan matematis yang mudah dimengerti. Fungsi keanggotaan menggunakan segitiga dan dinyatakan secara numerik serta Metoda inference yang digunakan adalah metode Mandani. Hasil-hasil percobaan menunjukkan bahwa semakin dekat jarak akan membuat pergerakan robot mobil semakin lebih halus. Encoder mempunyai rata-rata persentase kesalahan sebesar 22.38% dan sensor ultrasonic mempunyai rata-rata perubahan waktu per 2 cm yaitu 0.114546 ms dengan kesalahan sebesar 4,14%.          Kata Kunci : robot mobil, logika fuzzy dan kontrol posisi.
Perancangan Rele Arus Lebih Dengan Karakteristik Invers Berbasis Mikrokontroler Atmega 8535 Cahayahati .; Mirza Zoni Zoni
JURNAL NASIONAL TEKNIK ELEKTRO Vol 1 No 1: September 2012
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1257.316 KB) | DOI: 10.25077/jnte.v1n1.64.2012

Abstract

Untuk melindungi peralatan listrik dari kerusakan akibat gangguan hubung singkat atau short circuit  penyebab masalah yang harus diaman diperlukan suatu alat pengaman arus lebih (over current protection atau over current relay (OCR)). Alat pengaman ini dapat bekerja dengan respon cepat, fleksibel, tidak mudah rusak, akurat dalam mengatasi gangguan dan dirancang dengan rangkaian elektronik berbasis mikrokontroler. Bentuk prototipe proteksi arus lebih digital (Digital over current protection) dengan karakteristik invers dengan rele arus lebih ini dirancang dengan menggunakan Hall Effect Current Sensor tipe ACS706 ELC020 sebagai pendeteksi arus. Perancangan rele arus lebih didukung oleh teknologi mikrokontroler AVR Atmega 8535 yang diprogram dengan BASCOM-AVR, dengan tingkat kepresisian waktu trip  yang tinggi.Kata kunci: Proteksi digital, Mikrokontroler, Hubung Singkat
Program Aliran Daya Untuk Analisis Sistem Distribusi Dengan Penambahan Photovoltaic Model Syafii .; Ricky Maulana
JURNAL NASIONAL TEKNIK ELEKTRO Vol 1 No 1: September 2012
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (662.715 KB) | DOI: 10.25077/jnte.v1n1.65.2012

Abstract

Perkembangan teknologi yang semakin pesat memicu kebutuhan akan energi, terutama energi listrik. Kondisi tersebut mengindikasikan bahwa listrik telah menjadi bagian yang sangat penting bagi umat manusia. Di negara berkembang seperti Indonesia, idealnya pertumbuhan listrik 2-2,5 kali lipat dibandingkan pertumbuhan ekonomi. Kenyataannya, saat ini pertumbuhan listrik per tahun hanya 7-8 persen. Penambahan pembangkit dengan energi yang dapat terbarukan menjadi salah satu solusi untuk mengatasi kebutuhan akan listrik. Seperti dengan penambahan pembangkit listrik dengan tenaga matahari atau photovoltaic. Dalam artikel ini, perhitungan aliran daya menggunakan metoda fast decoupled dengan model photvltaic yang terhubung ke jaringan distribusi. Program aliran daya dibangun menggunakan Microsoft visual studio 2010 dengan Bahasa Pemograman C++.Penambahan  variasi jumlah dan ukuran photvoltaic pada sistem distribusi akan mengurangi rugi-rugi daya dan jatuh tegangan. Kata Kunci :Kebutuhan listrik, Photovltaic, Microsoft visual studio 2010, Rugi-rugi daya, Jatuh tegangan
Simulasi dan Analisa Sistem Kendali Kecepatan Motor Arus Searah Dengan Pendekatan Tempat Kedudukan Akar Heru Dibyo Laksono
JURNAL NASIONAL TEKNIK ELEKTRO Vol 1 No 1: September 2012
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jnte.v1n1.66.2012

Abstract

Dalam pengendalian kecepatan motor arus searah, model sistem bersifat nonlinier. Untuk menganalisa pola tingkah laku disekitar titik operasi, salah satu model sistem adalah dengan dilinierisasi di titik operasi. Berdasarkan model sistem yang dilinierisasi tersebut diperoleh fungsi alih  motor arus searah dan dirancang pengendali Proporsional (P), Proporsional Integral (PI), Proporsional Diferensial (PD) dan Proporsional Integral Diferensial (PID) melalui suatu simulasi dengan menggunakan perangkat lunak Matlab serta pendekatan tempat kedudukan akar. Hasil simulasi didapatkan nilai konstanta Proporsional (P), konstanta Integral (I) dan konstanta Diferensial (D)  pengendali yang mengendalikan kecepatan motor arus searah. Kata Kunci : motor arus searah (DC),  pengendali proporsional (P), pengendali proporsional integral (PI),  pengendali proporsional diferensial, pengendali proporsional integral diferensial (PID), tempat kedudukan akar.
Simulasi Kualitas Daya Saluran Distribusi Sekunder Perumahan Andi Faharuddin; Gunawan Wibisana
JURNAL NASIONAL TEKNIK ELEKTRO Vol 1 No 1: September 2012
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (795.887 KB) | DOI: 10.25077/jnte.v1n1.67.2012

Abstract

Lazimnya, beban listrik pada perumahan  berupa kombinasi antara beban linear dan beban nonlinear. Beban-beban nonlinear misalnya peralatan-peralatan elektronik yang terpakai di rumah, berpotensi  menurunkan kualitas daya saluran distribusi sekunder secara signifikan akibat besarnya kandungan harmonik arus yang ditariknya. Persentase THD arus yang tinggi pada sistem, dapat menyebabkan beberapa persoalan harmonisa seperti misalnya meningkatnya rugi-rugi sistem, overload penghantar netral, interferensi pada sistem komunikasi dan lain sebagainya. Pada penelitian ini, beban sistem distribusi sekunder perumahan dimodelkan dalam tiga macam model: model beban linear, nonlinear dan gabungan beban linear dan nonlinear, di dalam laboratorium. Selanjutnya, diadakan simulasi dan pengukuran pada saluran penyuplai daya (distribusi sekunder) bagi masing-masing model-model tersebut dengan  menggunakan alat ukur power fluke analyzer 43. Hasil penelitian menunjukkan bahwa model beban nonlinear menyebabkan degradasi kualitas daya yang sangat signifikan (hingga kisaran 90 persen), jauh melebihi beban linear. Model beban linear menjadi model yang sesuai dengan standar distorsi harmonisa yang ditetapkan oleh IEEE-519-1992.Kata kunci :  THD, individu harmonisa, spektrum harmonisa, beban linear, beban nonlinear, sistem distribusi sekunder.
Pengembangan Sistem Proteksi Digital Arus Lebih Berbasis Logika Fuzzy Sebagai Pengaman PLTMH Cahayahati .; Syafii .; Ija Darmana; Zulwisli .
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2 No 2: September 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (627.193 KB) | DOI: 10.25077/jnte.v2n2.68.2013

Abstract

In this paper discussed digital overcurrent protection system fuzzy logic on plant systems or Micro Hydro Power Plants with fuzzy logic approach to the identification of the signal changes due to interference overcurrent short circuit the lifeboat station on the system. A digital overcurrent protection with a fuzzy logic-based method and the rules set if-then, fuzzification and defazzification which has 2 inputs are crisp and delta error and error the actual fault current has a crisp output 1 to input changes in current to drive the relay breaker. This system consists of a hardware system with microcontroller (mc) ATMega8535 and other series as well as software that helps in the protection process performance Delpi 7 computer using fuzzy logic and program using C language and dicompel with CodeVisionAVR software and uploaded to the microcontroller using ponyprog2000 ATMega8535. The success of a prototype digital overcurrent protection system was tested on a fuzzy logic system voltage of 220 volts with a simple system technique burdened beyond any current settings and calculated over a given working time protection relay. After testing and calculations, then the inverse Characteristics of digital protection between the current disruption to the working time protection can be envisaged that a larger fault current less time working to secure protection from interference generating systems.Keyword : Fuzzy Logic, ATMega8535, Proteksi Digital.AbstrakDalam makalah ini dibahas sistem proteksi digital arus lebih logic fuzzy (Fuzzy Logic Protection) pada sistem pembangkit atau Pembangkit Listrk Tenaga Mikro Hidro dengan pendekatan fuzzy logic untuk identifikasi perubahan sinyal besar gangguan arus lebih akibat hubung singkat yang terjdi pada sistem pembangkit. Suatu proteksi digital arus lebih dengan metode berbasis logika fuzzy dan kaidah-kaidah atur if-then, fuzzifikasi dan defazzifikasi yang mempunyai 2 crisp input yaitu error dan delta error arus gangguan aktual dan mempunyai 1 crisp output perubahan arus untuk input rele untuk menggerakan pemutus. Sistem ini terdiri dari perangkat keras dengan sistem mikrokontroler (mc) ATMega8535 dan rangkaian lainnya serta perangkat lunak yang membantu penampilan proses proteksi di komputer menggunakan Delpi 7 dan program fuzzy logic menggunakan bahasa C dan dicompel dengan software CodeVisionAVR dan diupload ke mikrokontroler ATMega8535 menggunakan ponyprog2000. Keberhasilan prototipe sistem proteksi digital arus lebih fuzzy logic diujikan pada sistem sederhana tegangan 220 Volt dengan teknik sistem dibebani melebihi setting dan setiap arus lebih yang diberikan dihitung waktu kerja rele proteksi. Setelah melakukan pengujian dan perhitungan, maka karaktristik invers proteksi digital antara arus gangguan terhadap waktu kerja proteksi dapat tergambar bahwa semakin besar arus gangguan semakin cepat waktu kerja proteksi untuk mengamankan sistem pembangkit dari gangguan. Keyword : Fuzzy Logic, ATMega8535, Proteksi Digital.  
Antena Kupu - Kupu Sebagai Sensor Ultra High Frequency (UHF) Untuk Mendeteksi Partial Discharge Pada Gas Insulation Substation Hanalde Andre; Umar Khayam
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2 No 2: September 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (978.164 KB) | DOI: 10.25077/jnte.v2n2.69.2013

Abstract

The use of antennas as receiving electromagnetic waves can be used as a tool for the detection of partial discharge (PD) that occurs in high voltage equipment. Especially in the insulation gas substation (GIS), the characteristics of the electromagnetic waves generated lies in the range of ultra high frequency (UHF) in the range of 300 MHz - 3 GHz. Characteristics of the antenna ultra wide band (UWB) is required to detect PD in a wide range. Antenna design is done using a simulation with finite element method or finite element method (FEM). Characteristics of return loss (RL) to be considered in the design of the antenna to get better sensitivity yan. Antenna testing is done with vector network analyzer (VNA). Measurement and simulation results of the modified antennas showed a decrease in the value of RL.Keywords : Partial Discharge (PD), Antena, Ulltra High Frequency (UHF),Gas Insulation Substation     (GIS) AbstrakPenggunaan antena sebagai penerima gelombang elektromagnetik dapat digunakan sebagai alat untuk mendeteksi kegiatan partial discharge (PD) yang  terjadi pada paralatan tegangan tinggi. Khususnya pada gas insulation substation (GIS), karakteristik gelombang elektromagnetik yang dihasilkan terletak pada rentang  ultra high frequency (UHF) dalam rentang 300 MHz – 3 GHz. Karakteristik antena ultra wide band (UWB) diperlukan untuk mendeteksi PD pada rentang yang lebar. Perancangan antena dilakukan menggunakan simulasi dengan metoda elemen hingga atau finite element method (FEM). Karakteristik return loss (RL) antena dipertimbangkan dalam perancangan untuk mendapatkan sensitivitas yan lebih baik. Pengujian antena dilakukan dengan vector network analyzer (VNA). Hasil pengukuran dan simulasi antena yang dimodifikasi menunjukkan penurunan nilai RL. Keywords : Partial Discharge (PD), Antena, Ulltra High Frequency (UHF),Gas Insulation Substation     (GIS)  
Evaluasi Pola Tingkah Laku Tegangan Sistem Eksitasi Generator Dengan Metoda Penempatan Kutub Menggunakan Algoritma Bass–Gura Heru Dibyo Laksono; Noris Fredi Yulianto
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2 No 2: September 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (439.493 KB) | DOI: 10.25077/jnte.v2n2.70.2013

Abstract

In power systems, the behavior patterns of excitation system voltage is very important to note because it can affect the voltage stability of the power system. Several previous studies showed performance behavior pattern generator excitation system voltage is less than satisfactory at the point of operation. Under these conditions, conducted a study of the patterns of behavior of dynamic voltage generator excitation system with pole placement method using the Bass-Gura algorithm. With the help of information obtained by Matlab software, that behavior pattern generator excitation system voltage indicates better performance compared to the performance of the behavior patterns of excitation system voltage without the pole placement method.Keywords: generator excitation systems, pole placement method, bass-Gura, performance AbstrakDalam sistem tenaga listrik, pola tingkah laku tegangan sistem eksitasi merupakan hal yang sangat penting untuk diperhatikan karena dapat mempengaruhi kestabilan tegangan sistem tenaga listrik.  Beberapa penelitian terdahulu menunjukkan performansi pola tingkah laku tegangan sistem eksitasi generator yang kurang memuaskan pada titik operasinya. Berdasarkan kondisi tersebut, dilakukan suatu studi dinamik mengenai pola tingkah laku tegangan pada sistem eksitasi generator dengan metoda penempatan kutub menggunakan algoritma Bass-Gura. Dengan bantuan perangkat lunak Matlab diperoleh informasi, bahwa pola tingkah laku tegangan sistem eksitasi generator menunjukkan performansi yang lebih baik dibandingkan performansi pola tingkah laku tegangan sistem eksitasi tanpa metoda penempatan kutub.Keywords: generator excitation systems, pole placement method, bass-Gura, performance  
Pengolahan Citra Digital Untuk Menghitung Luas Daerah Bekas Penambangan Timah Rika Favoria Gusa
JURNAL NASIONAL TEKNIK ELEKTRO Vol 2 No 2: September 2013
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (377.881 KB) | DOI: 10.25077/jnte.v2n2.71.2013

Abstract

Image processing technology gives extraordinary advance in various fields included satellite image utilization. Through some processing phases, it can be acquired information about digital image features such as area or size of the object. In Province of Bangka Belitung Archipelago, there are many tin mining regions. In this research, digital image processing of certain region in Bangka Belitung is carried out to obtain the area of tin ex-mining. The research started with survey to get coordinate and dimension (length and width) of the tin ex-mining. The coordinate used to obtain satellite image of the tin ex-mining. Furthermore, satellite image (RGB image) converted to grayscale image. The grayscale image enhanced through contrast stretching process, and then it converted to binary image. Morphology operations, that are erosion and dilation, applied to the binary image so that the total pixels of the image object (tin ex-mining) can be counted. The real dimension (length and width) of the tin ex-mining used to get the scale for calculating the image object area (tin ex-mining) in m2.Keywords: digital image processing, area, tin ex-mining AbstrakKehadiran teknologi pengolahan citra memberikan kemajuan yang luar biasa pada berbagai bidang termasuk pemanfaatan citra satelit. Melalui berbagai tahapan pengolahan, dapat diperoleh informasi yang diinginkan tentang fitur tertentu dari sebuah citra digital antara lain luas atau ukuran objek. Di Provinsi Kepulauan Bangka Belitung, banyak terdapat daerah penambangan timah. Dalam penelitian ini, dilakukan pengolahan citra digital dari suatu wilayah tertentu di Provinsi Kepulauan Bangka Belitung yang memiliki daerah bekas penambangan timah untuk dapat diketahui luasnya. Penelitian dimulai dengan survei lapangan untuk memperoleh data berupa koordinat serta ukuran (panjang dan lebar) daerah bekas penambangan timah. Koordinat tersebut digunakan untuk memperoleh citra satelit dari daerah bekas penambangan timah. Selanjutnya, citra satelit berupa citra warna (RGB) diubah menjadi citra grayscale. Citra grayscale kemudian diperbaiki melalui proses perenggangan kontras, lalu diubah menjadi citra biner. Operasi morfologi yaitu erosi dan dilasi diterapkan pada citra biner tersebut sehingga dapat dihitung jumlah piksel objek (daerah bekas penambangan timah) di dalam citra. Ukuran sebenarnya (panjang dan lebar) daerah bekas penambangan timah digunakan untuk mengetahui nilai skala yang diperlukan guna menghitung luas objek citra (daerah bekas penambangan timah) dalam satuan m2.Keywords: digital image processing, area, tin ex-mining