Kadar D-Dimer Sebagai Indikator Derajat Keparahan Pada Pasien Terkonfirmasi Covid-19 di RS. Permata Hati Tangerang Armal, Hadits Lissentiya; Bakti, Sukma; Annisa, Istiana
Journal of Medical Laboratory Research Vol. 2 No. 2 (2024): Journal of Medical Laboratory Research
Publisher : Politeknik Kesehatan Kementerian Kesehatan Banten

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36743/jomlr.v2i2.732

Abstract

Terdapat beberapa pemeriksaan yang dapat dilakukan untuk mendiagnosa derajat keparahan infeksi COVID 19 diantaranya menggunakan pemeriksaan AGD, PT, APTT, D-dimer, NLR, ataupun Thorax Pa. Pemeriksaan D-dimer menjadi salah satu pemeriksaan yang sangat beperan penting dalam menentukan derajat keparahan pasien isolasi/ pasien yang infeksi COVID 19. D-dimer secara efektif memprediksi kematian di rumah sakit pada pasien COVID-19, yang mengindikasikan D-dimer dapat menjadi penanda awal dan bermanfaat untuk meningkatkan manajemen pasien COVID-19 Tujuan: penelitian ini adalah untuk mengetahui hubungan antara kadar d-dimer dan klasifikasi derajat keparahan pada pasien terkonfirmasi COVID-19 di RS. Permata Hati Tangerang. Metode: Jenis penelitian dengan pendekatan cross-sectional, populasi berjumlah 713 pasien, sampel berjumlah 256 responden, analisis dengan menggunakan uji chi-square. Hasil: Menunjukkan adanya hubungan antara kadar d-dimer dengan klasifikasi derajat keparahan pada pasien terkonfirmasi covid-19 di RS Permata Hati Tangerangkarena nilai p-value 0,000< (α= 0,05). Maka dapat disimpulkan bahwa Ha diterima dan Ho ditolak, jadi ada hubungan antara kadar d-dimer dengan klasifikasi derajat keparahan pada pasien terkonfirmasi covid-19 di RS Permata Hati Tangerang.
Pooled Serum in House sebagai Bahan Kontrol untuk Pemantapan Mutu Internal Nuraeni, Hanny Siti; Armal, Hadits Lissentiya; Astriani, Ranti Dwi
Journal of Medical Laboratory Research Vol. 3 No. 2 (2025): Journal of Medical Laboratory Research
Publisher : Politeknik Kesehatan Kementerian Kesehatan Banten

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36743/jomlr.v3i1.827

Abstract

One method used to carry out internal quality control at the analytical stage is to use control serum. . For some clinical laboratories, especially primary clinical laboratories where the number of clinical examinations is still small, the use of commercial control serum for quality control is not affordable because the cost is very expensive. Production of control materials from pooled blood serum can be used as an alternative to expensive production controls. The aim of this study was to find out whether serum collected at home can be used as a control material to carry out quality tests by determining its homogeneity and stability.The implementation process includes taking samples, sample from 48 person and then making pooled serum, examining pooled serum, homogeneity and stability tests, determining reference value ranges, and analyzing results. The combined serum that has been made is homogeneous and stable in the parameters of glucose and total cholesterol, while it is unstable in uric acid. The pooled serum value range for glucose is 49-86 mg/dL, total cholesterol 196-288 mg/dL and uric acid 1.36-3.70 mg/dL. The results of making pooled serum as a control material are declared homogeneous and stable in terms of glucose and total cholesterol parameters so that it can be used as quality control in daily activities. Suggestions for future researchers to add other parameters related to clinical chemistry examinations.