Fuzzy Logic Temperature Control on Baby Incubator Transport Battery Efficiency Co’o, Yohanes Cristomus; Wisana, I.D.G. Hari; Kholiq, Abd
Jurnal Teknokes Vol. 17 No. 1 (2024): March
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Baby incubator transport is a life support tool used to maintain the body temperature of newborn babies during transportation from one place to another, such as from a hospital to an intensive care center with more complete facilities. The problem that often occurs in transport incubators is limitations in the power system. Baby incubator transport uses a battery as the main power source. However, the limited battery power can cause risks to the baby if there is a problem with the power system or the battery runs out. This study aims to monitor the remaining battery voltage in a transport baby incubator that uses fuzzy logic to control the temperature inside and will compare with the performance of PID control. This research uses a fuzzy logic method to control temperature and maximize battery power. In this study, researchers only looked at the efficiency of the fuzzy logic method in temperature control and the battery that will be used. The research uses a display that will display the battery voltage and current values, battery power percentage, skin temperature, chamber temperature, humidity and the selected temperature control. The module that has been made is then compared with the Digital Multimeter measuring instrument. From the results of data collection, the measurement of the remaining battery voltage between the sensor reading and the measuring instrument has a difference where at a temperature of 34 ºC it is 2.1%, at a temperature of 35 ºC it is 2% and at a temperature of 36 ºC it is 3.9%. When compared to research using PID control, fuzzy logic takes longer to reach the desired temperature and demands more battery power when compared to PID control.
PID Temperature Control of Baby Incubator Transport Battery Efficiency Vidaryanto, Angga; Wisana, I.D.G Hari; Kholiq, Abd; Dewiningrum, Riqqah
Jurnal Teknokes Vol. 17 No. 1 (2024): March
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Transport baby incubators are used to keep babies warm and safe while in transport using battery voltage sources or DC electricity, which are portable and can be used without getting a supply of electrical energy. The problem that often occurs with this tool is the limited battery power system. causes a risk to the infant in the event of power failure or battery exhaustion. We aim to evaluate the battery efficiency of Baby Incubator Transport using a PID temperature controller. The evaluation is done by comparing and analyzing the battery voltage of the device to the standard device, as well as considering the setting temperature and duration of use of the device so that it can provide convenience in evacuating babies in an emergency. The tool uses the PID method to control temperature and maximize battery power. In this design, researchers only look at the efficiency of the PID method on temperature control and the battery to be used. This module will have a display that will display the battery voltage value, battery voltage percentage, skin temperature, chamber temperature, humidity, and temperature control that has been selected in the form of a graph. Compared with the digital multimeter measuring instrument. From the results of data collection, it can be concluded that the PID method has a faster rise time to reach the setting temperature, while the fuzzy method has a longer rise time to reach the setting temperature. However, the PID method requires more battery power than the Fuzzy method. The measurement results between the display and the measuring device have a difference of 3.1% at 34°C, at 35°C it is 3.9%, and at 36°C it is 4.7%. The biggest error is at a temperature of 36ºC, the smallest is at a temperature of 34ºC. Based on the results of the observation analysis of battery power consumption, it is found that the smaller the battery energy, the smaller the current issued, as well as the voltage issued. But if the load is large, the current is inversely proportional to the center, the battery voltage decreases while the current increases.
Erika (Local Wisdom E-module) Dhadak Merak Dance on Newton’s Material Choirunnisa', Adinda; Kholiq, Abd
Jurnal Pembelajaran Fisika Vol 11, No 2 (2023): Jurnal Pembelajaran Fisika
Publisher : Jurnal Pembelajaran Fisika

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The research carried out is development research which aims to produce e-modules based on local wisdom that are declared feasible. Feasibility is reviewed based on validity, practicality and effectiveness. This development research uses the Hannnafin & Peck model by going through three stages, namely needs assessment, design and development as well as implementation. In terms of validity, an average percentage of 93.45% is obtained with a very valid category. Practical results were obtained from the implementation and learning constraints by using Erika (local wisdom e-module) Dhadak Merak Reog Ponorogo dance which was stated to be practical. The implementation of learning using Erika gets 91.67% results in a very good category. The results of process-based activities using e-modules in learning obtained an average percentage of 75.71 in the good category. The effectiveness of student learning outcomes has increased with an average n-gain score of 0.3 in the moderate category. The results of student responses to learning using Erika (local e-module) Dhadak Merak Reog Ponorogo Dance obtained an average percentage of 87.59% in the very good category. Thus Erika (local wisdom e-module) Dhadak Merak Reog Ponorogo Dance on Newton's Law material is declared suitable for use in terms of validity, practicality, and effectiveness to be applied in learning.
A Low Cost Baby Incubator Design Equipped with Vital Sign Parameters Lamidi, Lamidi; Kholiq, Abd; Ali, Muslim
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 2 (2021): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.203

Abstract

The aim of this study was to create a compact system at a low cost in an infant incubator. Apart from stabilizing the temperature, it can also calculate the premature baby's heart rate and oxygen saturation value. The contribution of the system being built can detect the early symptoms of congenital abnormalities so that abnormalities detection becomes more practical. The temperature stability in this system uses a threshold system, where the sensor readings are compared with the set point value. Meanwhile, the SpO2 system uses a finger sensor attached to the baby's finger to detect oxygen saturation and heart rate. The signal from the sensor is processed in a signal conditioning circuit consisting of an astable circuit, filter and amplifier, LPF, and demultiplexer. Based on the results of testing and measurement, the difference produced by this tool is only 0.13 - 0.182 ° C. The biggest error in the system is 0.517%. Measurement of skin temperature was carried out on 10 respondents with an average value of 34.825 ° C. so that the difference generated from this tool is only 0.175 ° C, the difference on the Humidity parameter is 0.21%. The average BPM reading of respondent 1 was 81 beats per minute and the average SpO2 value was 97%. The average BPM reading of respondent 2 was 83 beats per minute and the average SpO2 value was 98%. You can see that the module with the Arduino control system can work automatically and is able to adjust the stability of the baby incubator according to the settings. In addition, the BPM and SpO2 systems are within tolerance so they can be used for patient measurements
Defibrillator with Monophasic and Biphasic Fibrillation Signal Wijaya, I Gusti Bagus Aditya; Wijaya, Aditya; Yulianto, Endro; Kholiq, Abd
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 1 No. 2 (2019): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v1i2.252

Abstract

Lack of knowledge about functions, working methods, and safety can pose a big risk (death). Defibrillators are electronic devices that flow the shock electrical signal (pulse) to the heart muscle to maintain myocardial depolarization that is experiencing cardiac fibrillation (ventricular fibrillation or atrial fibrillation). The purpose of this study is make a defibrillator as a learning material so that anyone can have sufficient knowledge about the working principle and function of the defibrillator tool. This defibrillator is equipped with two wave selections namely monophasic and biphasic with asynchronous and synchronous modes, the energy provided ranges from 10-50 joules with use on tools 10, 20, 30, 50 joules. The energy will be flowed to the patient by pressing the Discharge button on Paddle which equivalently is adapted to humans. Energy disposal is controlled by a driver then the relay will work alternately from the first condensator then the second condensator to Paddle. Energy testing is done by 10 times using a defibrillator analyzer in a predetermined test point, the results of the monofacic wave measurement obtained by the error value of each setting with the smallest value of 0.0024% and the largest error value of 0.023%. To produce energy (joule) that appropriate capacitor is needed with real value. Bifasic waves cannot be tested because the defibrillator analyzer measuring instrument cannot detect the energy value (joule) capacitor that has been delivered.
A Fuzzy Logic Approach for Temperature Stability in Infant Incubator Systems Syaifudin; Abd. Kholiq; Anita Miftahul Maghfiroh
Engineering Science Letter Vol. 4 No. 03 (2025): Engineering Science Letter
Publisher : The Indonesian Institute of Science and Technology Research

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56741/IISTR.esl.001451

Abstract

An infant incubator is a critical life-support device that provides thermal regulation for premature or low-birth-weight infants who are unable to maintain stable body temperature. Precise temperature control is essential, as instability and prolonged transient responses can increase health risks. Conventional on-off control methods commonly used in basic incubator systems often result in slower stabilization and higher temperature error. Therefore, this study aims to design and implement a baby incubator temperature control system using a fuzzy logic controller (FLC) integrated with a DS18B20 temperature sensor to improve thermal stability. The proposed system was implemented on a physical incubator prototype and evaluated experimentally. System performance was assessed based on dynamic response characteristics, including rise time, peak overshoot, and settling time. Experiments were conducted using three temperature setpoints: 32°C, 35°C, and 36°C. To ensure measurement accuracy, system performance was validated using an Incu Analyzer as a reference device. The experimental results show that the fuzzy logic-based control system achieved a steady-state temperature error of approximately 1% across all setpoints. The maximum observed settling time after peak overshoot was 100 seconds, indicating faster and more stable temperature regulation compared with conventional on-off control methods reported in previous studies. These results demonstrate that fuzzy logic control is effective in handling nonlinear thermal dynamics and improving temperature stability in infant incubator systems. This study focuses on technical performance evaluation; therefore, further investigations related to safety assessment and regulatory compliance are required before clinical implementation. Nevertheless, the proposed system shows strong potential as an intelligent temperature control approach for the development of neonatal incubator technology.
Temperature response analysis between PD and PI controls applied to infant incubators Abd. Kholiq; Lamidi Lamidi; Farid Amrinsani; Anisia Yunita Maulani Argumery; Hafizh Aushaf Mahdy
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 2: April 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i2.25879

Abstract

Premature infants, born with low birth weight, require specialized care and isolation due to their vulnerability to infections in public settings. Baby incubators, classified as life support equipment, play a crucial role in safeguarding these infants by maintaining a consistent temperature and humidity similar to the mother’s womb. This study compares the temperature control systems in baby incubators, specifically proportional and derivative (PD) control versus proportional and integral (PI) control. LM35 and DS18B20 sensors were employed in the study. Results from PD control using the LM35 sensor show a rise time of 5 min and 40 sec, a settling time of 25 min, and an overshoot of 2.2 °C. The DS18B20 digital sensor, under PD control, achieves a rise time in 6 min and 30 sec, a settling time of 23 min, with an overshoot of 1.2 °C. For PI control with the LM35 sensor, there’s a 3 °C overshoot, a 5-minute rise time, and a 30-minute settling time. The DS18B20 sensor under PI control exhibits a 2.7 °C overshoot, a 5-minute rise time, and a 29-minute settling time. PD control demonstrates lower overshoot and faster response but longer rise times than PI control. Future research explores fuzzy control systems and proportional integral derivative (PID)-fuzzy hybrid control.
Telemedicine-based baby incubator system with DWT method to detect respiratory rate from electrocardiogram signals Bambang Guruh Irianto; Anita Miftahul Maghfiroh; Mohamad Sofie; Yuni Kusmiati; Abd. Kholiq
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 6: December 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i6.26048

Abstract

This pioneering research introduces a telemedicine-based baby incubator designed to accurately monitor premature babies’ electrical heart signals and respiratory rates. The research aims to monitor premature babies, especially those related to heart and respiratory problems. This research combines telemedicine technology with the discrete wavelet transform (DWT) method to obtain respiratory rate values from electrocardiogram (ECG) signal leads directly. This research contribution can be used for simultaneous and non-invasive monitoring of heart electrical signals and respiratory rate. By leveraging existing telemedicine infrastructure, this incubator enables real-time monitoring. Using a data-driven approach with premature babies as subjects, respiratory signals are captured using sensitive sensors and analyzed via the DWT method. The results show that the accuracy of this telemedicine-based incubator is superior in monitoring respiratory rate compared to conventional methods with a P-value>0.05. This study confirms the effectiveness of DWT-based telemedicine incubators in monitoring the breathing of premature babies, thereby offering superior performance compared to traditional methods. The implications resulting from this research as a whole, this telemedicine-based baby incubator marks a significant advancement in the care of premature babies, ensuring precise and real-time breathing monitoring.