Ruliyanta Ruliyanta
Program Studi Teknik Elektro Universitas Nasional, Jakarta 12520

Published : 15 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 15 Documents
Search

PENDAMPINGAN PENGUKURAN PROFILE BEBAN LISTRIK DI GEDUNG PUSAT BELANJA Ruliyanta Ruliyanta; Wismanto Setyadi; Muhammad Al Fauzi
JMM (Jurnal Masyarakat Mandiri) Vol 7, No 4 (2023): Agustus
Publisher : Universitas Muhammadiyah Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31764/jmm.v7i4.16480

Abstract

Abstrak: Kegiatan ini dilakukan pasca Pandemi COVID-19 di Indonesia. Dampak Pandemi COVID-19 di Indonesia secara signifikan sangat mengganggu ekonomi di Indonesia, pusat belanja banyak ditinggalkan konsumen dalam hal ini penyewa toko. Saat ini, gedung mulai beroperasi secara normal. Tentunya terjadi perubahan profile energi sebelum dan pasca terjadi pandemi. Profile energi diperlukan untuk melihat indeks konsumsi energi (IKE). Kegiatan pendampingan pengukuran beban listrik ini bertujuan untuk melihat profile konsumsi energi dan analisisnya menghasilkan nilai IKE. Hasil pendampingan berjalan dengan lancar atas 15 orang teknisi secara bergilir. Metode pendampingan dalam kegiatan ini berupa arahan teknis dan klasifikasi pengukuran beban listrik bangunan berdasarkan kelompok profile konsumsi energi. Hasil pendampingan berupa profile konsumsi energi. Hasilnya terjadi anomali dimana konsumsi energi untuk sistem AC yang digunakan hanya 48 %, sedangkan nilai rata-rata di pusat perbelanjaan di Indonesia adalah 62,9 %. Besarnya listrik yang dijual kembali kepada tenant mencapai 37 %, selebihnya digunakan untuk mendukung fasilitas gedung lainnya. Kegiatan ini juga menghasilkan analisis IKE sebesar 17,46 kWh/bulan/m2 atau setara dengan 209,47 kWh/m2/tahun untuk nilai GFA (Gross Floor Area).Abstract: This activity was carried out after the COVID-19 Pandemic in Indonesia. The impact of the COVID-19 Pandemic in Indonesia has significantly disrupted the economy in Indonesia; many shopping centers have been abandoned by consumers, in this case, shop tenants. Currently, the building is starting to operate normally. Of course, there was a change in the energy profile before and after the pandemic. The energy profile is needed to see the energy consumption index (IKE). This assistance activity aims to see the energy consumption profile and its analysis to produce an IKE value. The results of the assistance went smoothly for 15 engineer. The assistance method in this activity is in the form of technical directives and classification of building electrical load measurements based on load group profiles. The assistance results in the form of an energy consumption profile. The result is an anomaly where the energy consumption for the AC system used is only 48 %, while the average value in shopping centers in Indonesia is 62.9 %. The amount of electricity resold to tenants reaches 37 %, and the rest is used to support other building facilities. This activity also resulted in an IKE analysis of 17.46 kWh/month/m2, or the equivalent of 209.47 kWh/m2/year, for the GFA (Gross Floor Area) value.
Perancangan Antena Komunikasi Selular Generasi ke-5 pada Frekuensi 2.350 MHz di Indonesia David Gideon; Ruliyanta Ruliyanta; Rianto Nugroho
Jurnal Ilmiah Giga Vol 26, No 1 (2023): Volume 26 Edisi 1 Tahun 2023
Publisher : Universitas Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47313/jig.v26i1.2468

Abstract

The current development of the cellular communication system has ushered in the 5G telecommunications era. The government has provided a 2.3 GHz frequency spectrum for 5G implementation in Indonesia. The frequency value used in the implementation of 5G technology in Indonesia which has just started can be said to have a high impact with a high attenuation value, so an antenna with the right dimensions and parameters is needed to be used in the application of 5G technology. In this study, a microstrip antenna was designed and manufactured with a 2x8 patch circular array shape working at a frequency of 2,350 MHz for application to 5G technology using the microstrip line feed feeder method. The design and manufacture of the antenna design utilize the Ansys HFSS application and uses the FR-4 Epoxy substrate with a dielectric constant value of 4.4, a substrate thickness of 1.6 mm, and a patch made of copper. The results of the design based on the simulation results obtained the working frequency value at 2,350 MHz with a return loss value of -21.9711 dB and a wide bandwidth of 109 MHz. The VSWR value obtained is 1.0849 with a gain value of 10.06 dB and a directional radiation pattern. Based on the results of the analysis, the microstrip antenna design test has good parameter values from previous studies at the same working frequency and the microstrip antenna is suitable for use to support the development of 5G technology.
PEMANFAATAN AIR LIMBAH SEBAGAI SUMBER AIR NON-POTABLE UNTUK SIRAM TAMAN DAN TOILET Ruliyanta Ruliyanta; R.A. Suwodjo Kusumoputro; Rama Asy'ari
JMM (Jurnal Masyarakat Mandiri) Vol 8, No 3 (2024): Juni
Publisher : Universitas Muhammadiyah Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31764/jmm.v8i3.22613

Abstract

Abstrak: Ancaman nyata dampak ekplorasi air bersih di Indonesia adalah menurunnya permukaan tanah utamanya di sekitar Pantai. Kota Jakarta, Semarang dan kota-kota besar di pesisir utara pulau Jawa sudah merasakan dampaknya. Untuk mengatasi permasalahan ini perlu dilakukan upaya konservasi lingkungan melalui pengendalian penggunaan air tanah. Gedung Inalum memiliki fasilitas pengolahan air limbah tetapi belum difungsikan. Kegiatan ini bertujuan untuk pendampingan para teknisi Gedung Inalum yang jumlahnya 14 orang dalam pemanfaatan air limbah sebagai air non-potabel untuk menyiram tanaman dan toilet Dengan adanya pendampingan, para teknisi yang ada mampu untuk melaksanakan kegiatan secara mandiri dan mampu meningkatkan hard skill mereka. Metode pendampingan yang dipakai adalah dengan pengawasan proses pengolahan air limbah dan perawatan peralatan pengolahan air limbah mulai dari sewage treatment plant, proses pemfilteran air, pompa transfer dan utilitas pemipaan.Kegiatan ini berhasil menurunkan konsumsi air bersih yang semula 728 m3 per bulan menjadi 270 m3 per bulan atau turun sebesar 62,91%. Sedangkan air yang dibuang ke saluran kota menurun yang 565 m3 turun menjadi 107 m3 atau turun 81,06%.Abstract: The real threat from water exploration in Indonesia is land subsidence, especially around the coast. Jakarta, Semarang and other major cities on the north coast of Java have already felt the impact. To overcome this problem, it is necessary to conserve the environment through controlling the use of groundwater. The Inalum building has a wastewater treatment facility but it has not been utilised. This activity aims to assist 14 Inalum Building technicians in the utilisation of wastewater as non-potable water for watering plants and toilets. With the assistance, the existing technicians are able to carry out activities independently and are able to improve their hard skills. The mentoring method used is to supervise the wastewater treatment process and maintenance of wastewater treatment equipment starting from the sewage treatment plant, water filtering process, transfer pump and piping utilities. This activity succeeded in reducing clean water consumption from 728 m3 per month to 270 m3 per month or a decrease of 62.91%. While water discharged into city drains decreased from 565 m3 down to 107 m3 or down 81.06%.
PELATIHAN ISO 17025:2017 UNTUK STANDARDISASI KINERJA DAN KUALITAS LABORATORIUM Puji Hartoyo; Ruliyanta Ruliyanta
JMM (Jurnal Masyarakat Mandiri) Vol 8, No 4 (2024): Agustus
Publisher : Universitas Muhammadiyah Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31764/jmm.v8i4.23432

Abstract

Abstrak: Pelatihan ISO 17025:2017 penting untuk standardisasi kinerja dan kualitas laboratorium pengujian dan kalibrasi. Standar ini memberikan panduan untuk memastikan bahwa laboratorium dapat melakukan pengujian atau kalibrasi yang konsisten, akurat, dan dapat dipercaya. Laboratorium Fakultas Teknik Universitas Tadulako belum berstandar ISO 17025:2017. Pelatihan ini bertujuan untuk memberikan penambahan hard skill dalam pemahaman persyaratan dan klausa yang terdapat dalam standar ISO 17025:2017 dan soft skill berupa komunikasi yang efektif, manajemen waktu dan ketrampilan interpersonal dalam pengelolaan laboratorium berstandar internasional. metode yang digunakan melalui ceramah dan diskusi dalam kelas serta praktek langsung. ... Peserta pelatihan ISO 17025:2017 terdiri dari 20 orang, yang terdiri dari dosen, laboran dan asisten laboratorium. Metode evaluasi yang dipakai berupa feedback dari peserta pelatihan dalam bentuk form pertanyaan singkat.. Hasilnya pengetahuan peserta pelatihan mengalami peningkatan sebesar 18%. Sementara hasil evaluasi proses pelatihan mendapatkan penilaian sebesar 3,76 dari para peserta pelatihan.Abstract: ISO 17025:2017 Training is important for standardizing the performance and quality of testing and calibration laboratories. These standard guides ensure that laboratories perform consistent, accurate, and reliable testing or calibration. The Tadulako University Faculty of Engineering laboratory is not yet ISO 17025:2017 standard. This training aims to provide additional hard skills in understanding the requirements and clauses in the ISO 17025:2017 standard and soft skills in effective communication, time management, and interpersonal skills in managing international standard laboratories. The method used is through lectures and discussions in class as well as direct practice. ISO 17025:2017 training participants comprised 20 people, including lecturers, laboratory assistants, and laboratory assistants. The evaluation method was feedback from training participants in a short question form. As a result, training participants' knowledge increased by 18%. Meanwhile, the results of the evaluation of the training process received an assessment of 3.76 from the training participants.
PENINGKATAN EFISIENSI PANEL SURYA MELALUI PERAWATAN BERKALA Ruliyanta Ruliyanta; R. A. S Kusumoputro; Puji Hartoyo
JMM (Jurnal Masyarakat Mandiri) Vol 8, No 1 (2024): Februari
Publisher : Universitas Muhammadiyah Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31764/jmm.v8i1.20255

Abstract

Abstrak: Panel surya memanfaatkan photovoltaic dan merupakann sumber pembangkit listrik terbarukan. Efisiensi panel surya tergantung pada kondisi permukaan panel tersebut. Benda yang menghalangi sinar matahari dapat mengganggu efisiensi listrik yang dihasilkan. Salah satu gedung yang memiliki pembangkit listrik tenaga surya adalah gedung Inalum. Permasalahannya, para teknisi belum memahami perawatan pembaangkit listrik tenaga surya. Untuk itu diusulkan pelatihan di gedung ini dengan tujuan memberikan tambahan pengetahuan. Pelatihan diikuti oleh 11 teknisi dan 2 orang supervisor. Sistem evaluasi yang dilakukan dengan cara melakukan pra dan pasca test dengan soal yang sama. Sebelum dan Proses pelatihan mendapatkan penilaian sebesar 4,23 skala 5. Sementara pelatihan ini mampu meningkatkan kemampuan peserta pelatihan sebesar 60,77% menjadi 95,38% atau mengalami kenaikan sebesar 34,16%. Dengan bekal pelatihan ini harapannya pembangkit listrik tenaga surya yang ada di gedung Inalum memiliki efisiensi yang baik melalui perawatan yang berkala.Abstract: Solar Cells are a technology that converts solar energy into electrical energy. Solar panels utilize photovoltaics and are a renewable source of electricity generation. The efficiency of solar panels depends on the surface condition of the panels. Objects that block sunlight can interfere with the efficiency of the electricity produced. One of the buildings with a solar power plant is the Inalum building. The problem is that technicians need to understand the maintenance of solar power plants. For this reason, training is proposed in this building to provide additional knowledge. Eleven technicians and two supervisors attended the training. The training process received an assessment of 4.23 on a scale of 5. Meanwhile, this training increased the training participants' abilities by 60.77% to 95.38% or an increase of 34.16%. With this training, the solar power plant in the Inalum building will have good efficiency through regular maintenance.