Articles
Snellen Chart Based On Android Control
Annisa Novantina Eka Fitria;
Priyambada Cahya Nugraha;
Lamidi Lamidi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 1 No 1 (2019): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (729.332 KB)
|
DOI: 10.35882/ijeeemi.v1i1.5
Eye vision is a person's visual acuity examination that is usually done using a snellen chart. Snellen chart is a poster that contains a number of letters that are different on each line with the letters getting closer to the bottom lines. Eye vision examination using a normal snellen chart is done at a distance of 6 meters because someone is considered normal if he is able to read on the 20/20 line in feet or 6/6 in meters. Snellen chart control android is an electronic snellen chart that controls the light transfer using Android. Commands originating from the mitapp application on android are sent to the bluetooth HC-05 module in the minsys Atmega16 circuit. Atmega 16 was chosen because it has a sufficient number of pins to control the displacement of the lights used by 23 lights. The appearance of the mitapp application has been adjusted to the letters contained in the snellen chart, making it easier for operator to correct the results of the readings that have been performed by the eye vision patient.
Bed For Measuring Ebv and CO With TFT Display Equipped With Data Storage (SpO2 and BPM)
Ahmad Zaky Ma'arif;
Priyambada Cahya Nugraha;
Andjar Pudji
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 1 (2020): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/jeeemi.v2i1.2
Abstract— BED for measuring EBV and CO are the tools used to monitor the condition of preoperative patients. The Estimation Blood Volume (EBV) is a calculation to determine the approximate volume of blood in the human body and CO is the amount of blood volume pumped by the heart per minute the calculation of EBV used uses weight, height and gender. CO calculations utilize BPM multiplied by standard Stroke Volume. In this section the author discusses oxygen saturation in the blood using different wavelengths of red LED light and infrared captured by the photodiode. The author also discusses BPM to monitor minute heart rates. The design of this measuring instrument uses MAX30100 sensor, Arduino Mega , Arduino Nano and TFT LCD. Data from the MAX30100 sensor enters the Arduino minimum system, then is processed to produce a percentage of SpO2 values which are then displayed on the TFT LCD. In the module, the data displayed can be stored and displayed again so that patient data can be traced. Testing is done by comparing the module with a standard measuring instrument that produces the biggest error of 2.80% on BPM and 0.95% on SpO2.
Development Portable Spirometer using MPXV7002DP Sensor and TFT Display for Lung Disease Detection.
Lizarazu Maulidil Li Kharis;
Andjar Pudji;
Priyambada Cahya Nugraha
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 3 (2020): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v2i3.3
Chronic obstructive pulmonary disease (COPD) is a disease whose prevalence tends to increase annually, with the World Health Organization (WHO) data predicting in 2020 the disease is the cause of the third-highest mortality worldwide. The assessment of the recurrence of COPD patients is very important, as it will accelerate the decline of lung function and health status. The purpose of this research is to design a spirometer by utilizing the MPXV7002DP sensor and equipped with a graphical display as well as lung health status on the Nextion TFT LCD. A portable Spirometer design has been done using the MPXV7002DP pressure sensor out as a transducer with a display on the Nextion TFT LCD. The design aims to determine the health of lung function by knowing the volume of lung Forced Vital Capacity (FVC), Forced Expired Volume in one second (FEV1), and Vital Capacity (VC). The working principle of this tool is to process the pressure from the results of the user blowing to the sensor through a mouthpiece which is designed based on Venturimeter law, the data will be processed by the Arduino microcontroller 2560 to be displayed on the LCD TFT and Nextion stored in SD card memory. The result of module validation data against a Spirometer 3L calibrator Benchmarking tool was obtained 1.58% VC error. The value is still below the 5% error tolerance limit so that the VC parameters in the secure module is used.
An Improved Measurement Accuracy of Fetal Heart Rate using Digital Filter
Riska Setyawati;
Priyambada Cahya Nugraha;
Her Gumiwang Ariswati;
Nur Hasanah Ahniar
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 3 (2020): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v2i3.5
Non stress test, there are several parameters including the fetal Doppler. fetal doppler is used to detect the fetal heart in the womb. It can be seen that the fetal heart rate in the womb under normal circumstances is in the range of 120-140 beats per minute. Noise on doppler fetal output can affect fetal heart rate readings. the purpose of this research is to design a non stress test device that is displayed on nextion. The contribution of this research is the creation of a portable device with nextion display and using analog and digital filters that can be used as noise removal. the method used to eliminate noise by using a bandpass type filter design frequency 20-40 Hz by designing a large frequency suppression outside the cutoff so that noise is not counted as a fetal heart rate. to detect the fetal heart rate in the mother's womb using a piezoelectric sensor. then the fetal heart rate obtained is filtered and the data is processed using Arduino after the results of processing the filter between analog bandpass and digital bandpass type Chebyshev method I then the results of the tool will be displayed on nextion. The results showed that measurements on analog filter modules that have been made produce an error value of 8.62% and digital filters that have been made produce an error value of 12.97%. The results of this study can be applied to fetal heart rate gauges portable at a health clinic.
Development of a Low-Cost and Effisient ECG devices with IIR Digital Filter Design
I Dewa Gede Hari Wisana;
Priyambada Cahya Nugraha;
Rizki Aulia Rachman
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 1 (2021): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v3i1.4
Measurement of biosignals such as electrocardiograph has the interpretation of noise from other signals. The noise can interfere with the measurement of the heart signal and make the measurement inaccurate, so the purpose of this study is to make a 6-Lead Electrocardiogram module with an Arduino-Based Digital Filter. By using a digital filter. The contribution of this research is the use of digital filters to eliminate noise in electrocardiograph signals. This research uses Infinite Impulse Filter digital filters such as Butterworth, Chebyshev I, Chebyshev II, and Elliptic in order 2, 4, 6, 8, and 10. The study was conducted by providing input from the Function Generator on Arduino which has been applied digital filters with Frequency with 0.5Hz – 100Hz cut-off. The instrument is compared with a factory electrocardiograph. Filter measurements using 460 input data. Butterworth filter with the greatest emphasis on order 8 frequency 0.5Hz produces an emphasis of -5.74298158 dB and a frequency of 100Hz produces an emphasis of -5.93529424 dB. The Chebyshev I filter has the greatest emphasis on order 6 frequency 0.5Hz producing an emphasis of -3.27104076 dB and on order 8 frequency 100Hz producing an emphasis of -5.08730424 dB. Chebyshev II filter the biggest emphasis on the order of frequency 0.5Hz produces a suppression of -44,66011104 dB and 80Hz frequency produces a suppression of -37,3653957 dB. Elliptic filters the greatest emphasis on order 6 frequency 0.5Hz produces an emphasis on -1.55429354 dB and 100Hz frequency on order 8 produces an emphasis on -2.2849115 dB. The results showed that what was appropriate with the cut-off frequency was the Butterworth order 8 filter which was suitable for the application of the Electrocardiograph signal filter because it had bandwidth that suppressed the signal outside the cut-off frequency. The results of this study can be implemented on a 6-Lead ECG module to eliminate noise or interference when tapping ECG signals.
Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters
Isna Fatimatuz Zahra;
I Dewa Gede Hari Wisana;
Priyambada Cahya Nugraha;
Hayder J Hassaballah
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v3i3.5
Acute myocardial infarction, commonly referred to as a heart attack, is the most common cause of sudden death where a monitoring tool is needed that is equipped with a system that can notify doctors to take immediate action. The purpose of this study was to design a heart attack detection device through indicators of vital human signs. The contribution of this research is that the system works in real-time, has more parameters, uses wireless, and is equipped with a system to detect indications of a heart attack. In order for wireless monitoring to be carried out in real-time and supported by a detection system, this design uses a radio frequency module as data transmission and uses a warning system that is used for detection. Respiration rate was measured using the piezoelectric sensor, and body temperature was measured using the DS18B20 temperature sensor. Processing of sensor data is done with ESP32, which is displayed wirelessly by the HC-12 module on the PC. If an indication of a heart attack is detected in the parameter value, the tool will activate a notification on the PC. In every indication of a heart attack, it was found that this design can provide notification properly. The results showed that the largest respiratory error value was 4%, and the largest body temperature error value was 0.55%. The results of this study can be implemented in patients who have been diagnosed with heart attack disease so that it can facilitate monitoring the patient's condition.
Implementation of a Microcontroller Arduino for Portable Peak Expiratory Flow Rate to Examine the Lung Health
Nabilla Farikha Azzahra;
Priyambada Cahya Nugraha;
Torib Hamzah;
Kamilu O. Lawal
International Journal of Advanced Health Science and Technology Vol. 2 No. 2 (2022): April
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijahst.v2i2.1
A peak flow meter will measure the ability to push air out of the lungs; the lungs are one of the body's most vital organs. The commonly used method is to deploy a peak flow meter, which uses mechanical systems. This mechanical system is prone to a high error rate of reading, and as a result, a more accurate and reliable means becomes inevitable. This paper describes the design and implementation of a micro-controller-based portable peak flow meter, which can be used to provide accurate data for the diagnosis of asthma, bronchitis, and emphysema. In the heart of the system are the programmable Mega Arduino microcontroller and a device called MPX5100GP sensor, which has a pressure range of 0-100 Kpa to detect a patient breath. The device was equipped with a display facility, which uses Nextion touch TFT output to display related tests and examinations. There is also a provision to store the results data using SD Card, while a printer prints the test results for further diagnostic purposes. An experimental setup in the laboratory shows that the designed micro-controller-based PFM shows that the error rate was between 0.50 % and 4.21 % compared with the mechanical-based peak flow meter. The application of micro-controller-based peak flow meters also allows real-time and remote monitoring of peak flow parameters. The evolution of modern technology has made the possibility of developing a micro-controller based portable, peak flow meters, which can be used to measure the data involved in the diagnosis of lung-related diseases more accurately.
Dynamic feature for an effective elbow-joint angle estimation based on electromyography signals
Triwiyanto Triwiyanto;
Triana Rahmawati;
Endro Yulianto;
Muhammad Ridha Mak'ruf;
Priyambada Cahya Nugraha
Indonesian Journal of Electrical Engineering and Computer Science Vol 19, No 1: July 2020
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.11591/ijeecs.v19.i1.pp178-187
Some physical parameters influence the electromyography signal (EMG). when the EMG signal is used to estimate the position of the elbow. An adaptable feature was important to reduce a variation on the parameters. The aim of this paper is to estimate the joint position of the elbow using EMG signal based on a dynamic function. The major contribution of this work is that the method proposed is capable of determining the elbow position using the non-pattern (NPR) recognition (PR) method. A Wilson amplitude (WAMP) which used a dynamic threshold was used to reduce the EMG signal. The dynamic threshold was generated from the root mean square (RMS) processor. With the dynamic threshold, the model could adapt to any variations on the independent variables. In order to confirm this opportunity, this work involved ten healthy male subjects to perform an experimental protocol. After a tuning and calibration process, the mean of RMS error and correlation coefficient are 9.83º±1.69º and 0.98±0.01 for a single cycle of motion, 10.39º±1.82º and 0.97±0.01 for a continuous cycle of motion and 15.19º±1.92º and 0.94±0.02 for the arbitrary gesture. For conclusion, the performance of the prediction did not significantly depend on the varying cycle of gesture (p-value>0.05). This study has confirmed that the success of the non-pattern recognition-based prediction of elbow position is adaptable to any different subjects, loads, and speed of motion.
Accuracy Analysis on Dual Pressure (Positive and Negative) Calibrator Design to Investigate the Sensor Response
Abdi Wibowo;
Triana Rahmawati;
Priyambada Cahya Nugraha;
I Dewa Gede Hari Wisana;
Honey Honey;
Mansour Asghari
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 3 (2022): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/jeeemi.v4i3.247
Calibration is an activity to determine the conventional correctness of the value of measuring instrument designation and measuring material by comparing against the measuring standards that are traced to national or international standards. A sphygmomanometer is a device used to measure blood pressure. Suction pump is a tool to suck various types of fluid formed from the body's secretion process that under certain conditions need to be cleaned. DPM (Digital Pressure Meter) is a tool for calibrating sphygmomanometers and suction pumps. Therefore, it takes a calibrator device to calibrate both tools. The purpose of this study was to determine the sensor response and analyze the accuracy of the design of a dual pressure calibrator (+ and -) that can be used for two devices at once (sphygmomanometer and suction pump) using one sensor (pss-C01V-R18 autonics). The research was conducted at the Campus of the Department of Electrical Engineering Of The Ministry of Health Surabaya, first the data was taken from three different brands of sphygmomanometer and suction pump, the second data was taken using module calibrators, and the third data collection from modules and comparison tools (DPM). In this study successfully measured positive and negative pressure with autonics sensors, the results obtained are accurate in accordance with the results of standard tools. The result of this tool can be used for dual pressure calibrators using autonics sensors.
Smartband for Heartbeat and Oxygen Saturation Monitoring with Critical Warning to Paramedic via IoT
I Dewa Gede Hari Wisana Wisana;
Priyambada Cahya Nugraha;
Farid Amrinsani;
Fani Ferina Sani;
Yusita Indhira Anwar;
Satheeshkumar Palanisamy
Jurnal Teknokes Vol 15 No 3 (2022): September
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/teknokes.v15i3.317
There are vital signs in the human body that indicate important physiological values for the body. In the COVID-19 pandemic, some of the important vital signs that must be monitored are BPM (Beats Per Minute) and SpO2 (oxygen saturation) as indicators of whether a person is in good health or lacks oxygen to predict the early symptoms of COVID-19. The purpose of this study is to create a device on the patient's wrist that can monitor BPM and SpO2 in real-time, as well as provide notifications on smartphones and emails when the patient's condition is abnormal. The contribution of this study is to implement an IoT (Internet of Things) system using a Wi-Fi connection so that monitoring activities are not separated by distance and time. The MAX86141 sensor is used in the design of this tool to detect the BPM and SpO2 values, after which the data is processed and displayed on the ESP32 TTGO T-Display. Monitoring results are also sent to the Blynk, and if the patient's condition is abnormal, an email notification is sent. According to the tool testing results, BPM has the smallest error of 0.94 percent and the largest error of 6.48 percent, whereas SpO2 has the smallest error of 0.20 percent and the largest error of 3.23 percent. The findings of this study can be used to improve the ease and efficiency of body health monitoring activities. This has the potential to significantly improve public health service quality, particularly during the COVID-19 pandemic