Analysis of Transmitted and Received ECG Signal Based on Internet of Thing Using Web Browser and Server-Client HTML Protocol Dewi Rushalina; I Dewa Gede Hari Wisana; Priyambada Cahya Nugraha; Nazila Ragimova
Jurnal Teknokes Vol 15 No 4 (2022): December
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v15i4.469

Abstract

Cardiovascular disease is one of the leading causes of death worldwide. One of the reasons for the large number of deaths from heart disease is the lack of regular cardiac monitoring. Electrocardiograph (ECG) is a method of monitoring heart conditions. There are still many ECG examinations in hospitals that are carried out directly in certain places and the results can only be seen at that time. Meanwhile, when negligence or carelessness occurs, it can endanger the patient due to delays in handling. One of the efforts that can be made to improve service to heart patients is by having ECG monitoring based on IoT (Internet of things). The purpose of this study is to analyze the ECG signals sent and received by IoT media so that they are useful for the diagnostic process. The contribution of this research is to know the shape of the ECG signal that is sent and received through IoT media. The procedure to achieve this goal is with the AD8232 sensor whose output will be processed through the microcontroller and displayed on computer and smartphones via IoT. From this research, the results obtained that the average value of lost data at BPM 60 and BPM 120 is quite good, namely 21.26% and 24.44%.hile the average time delay value at BPM 60 and BPM 120 is also quite good, namely 0.023 s and 0.03 s. So, it can be concluded that the sending of IoT-based ECG signals affects the form of signals sent and received. The results of this study are expected to be developed in further research with development in the form of adding leads or adding BPM parameters.
Bedside Monitor Based on Personal Computer Using STM32F7 Microcontroller Ingga Ariestya Riswandhani; Priyambada Cahya Nugraha; Syaifudin Syaifudin
Jurnal Teknokes Vol 16 No 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v16i2.566

Abstract

A vital sign examination is one of the important indications used to establish the diagnosis of a disease and is useful for determining the medical treatment plan needed for the patient. An electrocardiograph (ECG) is a parameter in medical equipment used in the process of measuring the electrical activity of the heart muscle by measuring biopotential differences from the body surface. In 2016, cardiovascular disease was the number-one cause of death in the world. This happens because the detection of cardiovascular disease is often late, so a monitoring tool is needed that can monitor the patient's condition quickly and efficiently. The purpose of this research is to create a tool that is used to facilitate the monitoring of patient conditions. The implication of this research is that in the many cases where the signal produced is not perfect and there is still a lot of noise, this can be overcome by using the STM32F7 microcontroller, which has a 16-bit resolution, so that the resulting signal will be better, smoother, and have less noise. produced is very small. The method used in this study was to use a phantom ECG as a comparison and to use five respondents whose BPM values were to be compared with another comparison using a pulse oximeter. The design of this tool uses an ECG analog circuit that is placed on the patient's lead II leads to detect the patient's electrocardiograph signal. Data processing will be done using the STM32F7 microcontroller, and the results of the data processing will be sent to the PC using Visual Basic. The results showed that the BPM error value using a phantom ECG was 2.5%. While the smallest error value is 0,83%. In BPM measurements using 5 respondents, the largest error value was 0.9% and the smallest error value was 0%. The results of these tests indicate that this module can be used to monitor the value of each parameter in accordance with the plan.
Educational for Technical Personnel of Krembangan Health Center in order to increase Awareness on Leakage Current Measurement for Medical Equipment and Patient Safety Ridha Makruf, Muhammad; Priyambada Cahya Nugraha; Pudji, Andjar
Frontiers in Community Service and Empowerment Vol. 3 No. 4 (2024): December
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v3i4.85

Abstract

The electrical safety of medical equipment is crucial to prevent hazards that endanger both healthcare workers and patients. Krembangan Health Center faces significant challenges due to staff's limited knowledge about electrical safety, including leakage current detection. The aim of this study was to enhance staff skills in ensuring electrical safety through a focused training program. The program covered the basics of electrical safety, leakage current risks, and practical use of a digital multimeter for inspections. Field surveys and practical training were conducted to inspect and measure electrical systems across the health center. Results revealed inadequate grounding, uneven load distribution, and leakage voltage up to 99 volts AC in the new building, while the old building had minor leakage issues. The conclusion emphasized the need for regular maintenance, comprehensive electrical safety audits, and ongoing staff training to ensure long-term safety. These efforts aim to create a safer healthcare environment, improving the reliability of medical equipment and safeguarding patient care.
Web-Based Infant Weight and Height Measurement for Early Stunting Detection at Krembangan Posyandu, Surabaya Pudji, Andjar; Ridha Makruf, Muhammad; Priyambada Cahya Nugraha
Frontiers in Community Service and Empowerment Vol. 3 No. 4 (2024): December
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v3i4.86

Abstract

Early childhood is a critical phase for physical and cognitive development, making early detection of stunting vital to a child’s long-term health. Traditional methods of measuring infant growth in regions like Indonesia rely on manual data collection, leading to delays in identifying stunting. This study aims to implement a web-based system for infant weight and height measurements to assist healthcare workers in early stunting detection at Krembangan Posyandu, Surabaya. The system provides real-time monitoring, automatic z-score calculations, and data storage, enhancing efficiency and accuracy. Methodologically, the tool was tested with 16 infants, allowing cadres to input measurements directly into a web platform for analysis. Results showed the tool's ease of use, increased speed in data handling, and improved access to growth data, reducing manual errors. The findings indicated that most infants had healthy growth, though a few required further attention. In conclusion, this web-based tool significantly improves the accuracy and timeliness of stunting detection, with implications for wider adoption in regions with limited healthcare infrastructure. However, limitations include a small sample size and a lack of assessment of long-term outcomes. Future research should focus on larger populations and the tool’s integration into broader healthcare systems
Bedside Monitor Based on Personal Computer Using STM32F7 Microcontroller Riswandhani, Ingga Ariestya; Cahya Nugraha, Priyambada; Syaifudin, Syaifudin
Jurnal Teknokes Vol. 16 No. 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

A vital sign examination is one of the important indications used to establish the diagnosis of a disease and is useful for determining the medical treatment plan needed for the patient. An electrocardiograph (ECG) is a parameter in medical equipment used in the process of measuring the electrical activity of the heart muscle by measuring biopotential differences from the body surface. In 2016, cardiovascular disease was the number-one cause of death in the world. This happens because the detection of cardiovascular disease is often late, so a monitoring tool is needed that can monitor the patient's condition quickly and efficiently. The purpose of this research is to create a tool that is used to facilitate the monitoring of patient conditions. The implication of this research is that in the many cases where the signal produced is not perfect and there is still a lot of noise, this can be overcome by using the STM32F7 microcontroller, which has a 16-bit resolution, so that the resulting signal will be better, smoother, and have less noise. produced is very small. The method used in this study was to use a phantom ECG as a comparison and to use five respondents whose BPM values were to be compared with another comparison using a pulse oximeter. The design of this tool uses an ECG analog circuit that is placed on the patient's lead II leads to detect the patient's electrocardiograph signal. Data processing will be done using the STM32F7 microcontroller, and the results of the data processing will be sent to the PC using Visual Basic. The results showed that the BPM error value using a phantom ECG was 2.5%. While the smallest error value is 0,83%. In BPM measurements using 5 respondents, the largesterror value was 0.9% and the smallest error value was 0%. The results of these tests indicate that this module can be used to monitor the value of each parameter in accordance with the plan.
Using Android Technology for Early Detection of Stunting in Toddlers in Krembangan Selatan Ridha Makruf, Muhammad; Pudji, Andjar; Nugraha, Priyambada Cahya; Wisana, I Dewa Gede Hari
Frontiers in Community Service and Empowerment Vol. 4 No. 3 (2025): September
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v4i3.116

Abstract

Stunting is a long-term health problem that mainly impacts the growth and development of young children, particularly in residential areas like Kelurahan Krembangan Selatan, Surabaya. A significant obstacle in preventing stunting is finding a practical way to assess children's nutritional status. This community study aims to raise awareness and educate people about the use of Android-based tools for monitoring body mass index (BMI) and basal metabolic rate (BMR) as innovative methods for detecting stunting risk. The device, tested on 16 infants, enables users to submit detailed data to a web platform for further analysis. Findings reveal that this tool simplifies processes, accelerates data handling, and provides quicker access to up-to-date information, thereby reducing the burden of manual tasks. Results also show that most infants have healthy growth, although some individuals may need more time to understand the benefits. In general, this web-based solution greatly improves the precision and speed of stunting detection and could be widely adopted in areas with limited healthcare infrastructure. However, the study is limited by its small sample size and limited assessment of result length. Future research should focus on a broader population and integrating this tool into larger healthcare systems. This innovation facilitates timely and accurate monitoring of young children's health. The hope is that it will become part of regular posyandu services to help strengthen the stunting prevention program across the Puskesmas Krembangan Selatan area.
Development of a Low-Cost and Efficient ECG devices with IIR Digital Filter Design Wisana, I Dewa Gede Hari; Nugraha, Priyambada Cahya; Rachman, Rizki Aulia
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 1 (2021): February
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i1.194

Abstract

Measurement of biosignals such as electrocardiograph has the interpretation of noise from other signals. The noise can interfere with the measurement of the heart signal and make the measurement inaccurate, so the purpose of this study is to make a 6-Lead Electrocardiogram module with an Arduino-Based Digital Filter. By using a digital filter. The contribution of this research is the use of digital filters to eliminate noise in electrocardiograph signals. This research uses Infinite Impulse Filter digital filters such as Butterworth, Chebyshev I, Chebyshev II, and Elliptic in order 2, 4, 6, 8, and 10. The study was conducted by providing input from the Function Generator on Arduino which has been applied digital filters with Frequency with 0.5Hz – 100Hz cut-off. The instrument is compared with a factory electrocardiograph. Filter measurements using 460 input data. Butterworth filter with the greatest emphasis on order 8 frequency 0.5Hz produces an emphasis of -5.74298158 dB and a frequency of 100Hz produces an emphasis of -5.93529424 dB. The Chebyshev I filter has the greatest emphasis on order 6 frequency 0.5Hz producing an emphasis of -3.27104076 dB and on order 8 frequency 100Hz producing an emphasis of -5.08730424 dB. Chebyshev II filter the biggest emphasis on the order of frequency 0.5Hz produces a suppression of -44,66011104 dB and 80Hz frequency produces a suppression of -37,3653957 dB. Elliptic filters the greatest emphasis on order 6 frequency 0.5Hz produces an emphasis on -1.55429354 dB and 100Hz frequency on order 8 produces an emphasis on -2.2849115 dB. The results of this study can be implemented on a 6-Lead ECG module to eliminate noise or interference when tapping ECG signals.
Snellen Chart Based On Android Control Fitria, Annisa Novantina Eka; Nugraha, Priyambada Cahya; Lamidi, Lamidi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 1 No. 1 (2019): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v1i1.239

Abstract

Eye vision is a person's visual acuity examination that is usually done using a Snellen chart. The Snellen chart is a poster that contains a number of letters that are different on each line with the letters getting closer to the bottom lines. Eye vision examination using a normal Snellen chart is done at a distance of 6 meters because someone is considered normal if he is able to read on the 20/20 line in feet or 6/6 in meters. Snellen chart control android is an electronic Snellen chart that controls the light transfer using Android. Commands originating from the Mitapp application on android are sent to the Bluetooth HC-05 module in the min sys Atmega16 circuit. Atmega 16 was chosen because it has a sufficient number of pins to control the displacement of the lights used by 23 lights. The appearance of the MIT app application has been adjusted to the letters contained in the Snellen chart, making it easier for operator to correct the results of the readings that have been performed by the eye vision patient
Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters Zahra, Isna Fatimatuz; Wisana, I Dewa Gede Hari; Nugraha, Priyambada Cahya; Hassaballah, Hayder J.
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 3 (2021): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.244

Abstract

Acute myocardial infarction, commonly referred to as a heart attack, is the most common cause of sudden death where a monitoring tool is needed that is equipped with a system that can notify doctors to take immediate action. The purpose of this study was to design a heart attack detection device through indicators of vital human signs. The contribution of this research is that the system works in real-time, has more parameters, uses wireless, and is equipped with a system to detect indications of a heart attack. In order for wireless monitoring to be carried out in real-time and supported by a detection system, this design uses a radio frequency module as data transmission and uses a warning system that is used for detection. Respiration rate was measured using the piezoelectric sensor, and body temperature was measured using the DS18B20 temperature sensor. Processing of sensor data is done with ESP32, which is displayed wirelessly by the HC-12 module on the PC. If an indication of a heart attack is detected in the parameter value, the tool will activate a notification on the PC. In every indication of a heart attack, it was found that this design can provide notification properly. The results showed that the largest respiratory error value was 4%, and the largest body temperature error value was 0.55%. The results of this study can be implemented in patients who have been diagnosed with heart attack disease so that it can facilitate monitoring the patient's condition
Robust Real-Time SpO₂ Signal Enhancement Using Optimized IIR Filtering in a Web-Based Vital Sign Monitoring System Indah Firdausi Nuzula; Priyambada Cahya Nugraha; Moch Prastawa Assalim Tetra Putra; I Dewa Gede Hari Wisana; Riqqah Dewiningrum; Alfi Nur Zeha; Syaifullah Yusuf
Jurnal Teknokes Vol. 19 No. 2 (2026): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jteknokes.v19i2.152

Abstract

SpO₂ is a critical physiological parameter in vital sign monitoring, particularly within Internet of Things (IoT) based healthcare systems that enable continuous and remote patient observation. However, the accuracy of SpO₂ measurements is often compromised by motion artifacts in photoplethysmograph (PPG) signals, which introduce amplitude distortion and frequency spreading that degrade oxygen saturation estimation. Although various signal processing approaches have been proposed, limited studies have evaluated digital filtering performance on real PPG signals using real-time embedded platforms with direct comparison of filter characteristics. This study aims to analyze the effectiveness of two Infinite Impulse Response (IIR) digital filters, Butterworth and Elliptic, in suppressing motion artifacts in SpO₂ signals processed on a microcontroller. Data were collected from ten healthy participants under three  conditions: baseline (no movement), induced finger motion, and filtered signals. Signal quality improvement was assessed using Fast Fourier Transform (FFT), Power Spectral Density (PSD), and Signal-to-Noise Ratio (SNR) analyses. Results indicate that motion artifacts increase high-frequency components above 3 Hz and disrupt the morphological integrity of the PPG waveform. Applying a low-pass IIR filter with a 3 Hz cutoff frequency successfully restored the principal periodic components. The Butterworth filter produced a smoother spectral response with minimal phase distortion, while the Elliptic filter achieved a sharper roll-off with slight passband ripple. Quantitative evaluation demonstrated average SNR improvements of +0.905 dB (Butterworth) and +0.899 dB (Elliptic) using FFT , and +0.98 dB and +0.66 dB, respectively, using PSD. These findings demonstrate that computationally efficient IIR filtering can be reliably implemented in resource-constrained embedded platforms without compromising signal integrity. This approach enhances signal stability, reduces false desaturation alarms, supports scalable deployment in wearable and telemedicine applications, improving patient safety and system robustness in continuous remote health monitoring.