Sistem Monitoring Konsumsi Daya Listrik Berbasis IoT untuk Efisiensi Energi pada Gedung PENMARU Universitas Muhammadiyah Lampung Yudi Eka Putra; Oktavia Eka Rahayu; Yenni Afrida; Jeckson Jeckson; Fitriono Fitriono; Sri Suryani
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 2 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n2.3199

Abstract

Abstract. Electrical energy usage in buildings with three-phase distribution systems requires proper monitoring to ensure energy consumption can be controlled effectively and efficiently. Common problems in building electrical systems include load imbalance between phases, delayed fault detection, and manual monitoring processes that prevent real-time observation of power consumption conditions. This study aims to design and develop an Internet of Things (IoT)-based electrical power consumption monitoring system for the PENMARU Building of Muhammadiyah University of Lampung using the PZEM-004T sensor and ESP32 microcontroller. The system was designed to monitor electrical parameters such as voltage, current, active power, electrical energy, and power factor in a three-phase electrical system in real-time through an IoT-based monitoring dashboard. The research method used in this study was Research and Development (R&D), which included system design, hardware and software implementation, system testing, and analysis of measurement results. The results showed that the system was able to monitor electrical parameters in real-time with a measurement error below 1%. The seven-day testing results indicated that the average power on phase R was 74.86 W, phase S was 225.64 W, and phase T was 51.01 W, with total electrical energy consumption reaching 47.06 kWh. In addition, the system successfully transmitted monitoring data stably through a Wi-Fi network and displayed the data on the IoT dashboard in real-time. Therefore, the proposed monitoring system is considered capable of supporting more effective, responsive, and efficient electrical energy consumption monitoring.
Effects of Butylated Hydroxytoluene and Butylated Hydroxyanisole on Viscosity and Breakdown Voltage of Palm Oil Yenni Afrida; Herman H Sinaga; Dewi A. Iryani; Nining Purwasih; Diah Permata
Journal of Renewable Energy, Electrical, and Computer Engineering Vol. 6 No. 1 (2026): March 2026
Publisher : Institute for Research and Community Service (LPPM), Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v6i1.26366

Abstract

In the electric power system, insulating oil plays a pivotal role in separating two or more electrical conductors with different voltages. This separation is crucial to prevent unintended electrical connections or sparks that could compromise the system's safety and integrity. Mineral-based insulating oil is disadvantageous because it is classified as a mineral oil. This classification indicates that the waste is non-biodegradable, meaning biological processes cannot break it down. This characteristic can hurt the environment. Therefore, alternative efforts must be made to use liquid insulation, such as environmentally friendly vegetable oils. Vegetable oils are unsuitable as insulating oils due to their high viscosity, low oxidation stability, and good lubricity. A proposed solution to reduce palm oil viscosity involves adding additives. The dilution process can be enhanced by incorporating various additives, including butylated hydroxytoluene and butylated hydroxyanisole. The present study utilizes the Megger OTS80Af to assess the breakdown voltage and viscosity of the subject material. Vegetable oils are unsuitable as insulating oils due to their high viscosity, low oxidation stability, and good lubricity. A proposed solution to reduce palm oil viscosity involves adding additives. The dilution process can be enhanced by incorporating various additives, including butylated hydroxytoluene and butylated hydroxyanisole. The present study utilizes the Megger OTS80Af to assess the breakdown voltage and viscosity of the subject material. The experimental findings indicate that crude palm oil, when augmented with butylated hydroxytoluene and butylated hydroxyanisole, is deemed unsuitable for utilization as a transformer insulation medium. This determination is predicated on its inability to comply with the stipulated criteria outlined in SPLN 49-91: 1982, specifically the minimum breakdown voltage of 30 kV/2.5 mm for transformer insulation oil.
Efect of Antioxydants on Viscosity and Breakdown Voltage of Palm Oil Insulation Ronald A Sitorus; Yenni Afrida; Herman H Sinaga; Dewi A Irayani; Nining Purwasih; Diah Permata
Journal of Renewable Energy, Electrical, and Computer Engineering Vol. 4 No. 1 (2024): March 2024
Publisher : Institute for Research and Community Service (LPPM), Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v4i1.16253

Abstract

Insulating oil is a type of insulator that is widely used as insulation in electrical equipment such as transformers. The insulating oil in the transformer functions as insulation in the transformer windings so that flashover does not occur and causes voltage leaks to the outside of the transformer, then the insulating oil also functions as a transformer coolant. Generally, the insulating oil used today is made from mineral oil which cannot be renewed so its availability is limited and may run out in the future. In an effort to reduce the use of mineral oil as a basic ingredient for insulating oil, it is necessary to develop a basic ingredient for making insulating oil, which can use vegetable oils such as crude palm oil (CPO) with the additive butylated hydroxytoulene added. In testing the suitability of crude palm oil with the addition of butylated hydroxytoulene additive as insulating oil, breakdown voltage testing was carried out using Megger OTS80Af and viscosity. Based on the test results, the highest breakdown voltage value was obtained for crude palm oil with the addition of butylated hydroxytoulene of 11.13 kV and a viscosity of 27.12 cSt. From the test results, it can be concluded that crude palm oil with the addition of butylated hydroxytoulene is not suitable for use as transformer insulating oil because it cannot meet the standard SPLN 49-91: 1982, the breakdown voltage of transformer insulating oil is 30 kV/2.5 mm.
Study On Implementation Of Watergate Control System From Manual To Automatic Based Arduino Nano ATmega328 Syafrudin, Ahmad; Jeckson, Jeckson; Afrida, Yenni
Emerging Information Science and Technology Vol. 5 No. 1 (2024): May
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/eist.v5i1.22424

Abstract

The system for processing river water into clean water by operating sluice gates which are controlled manually by operators often causes problems (human error), so a system must be created that is capable of controlling sluice gates automatically. The turbidity sensor detects water turbidity which is then accepted by the Arduino nano as the basis for controlling the water gate. In this research, data collection techniques were carried out using interviews with resource persons (operators), observation and literature study. After the automatic sluice control system based on the Arduino nano ATmega328 was implemented, the results obtained were: When the water conditions are muddy and murky, relay one is "on", relay two is "off" (the sluice gate is closed), while when the water conditions are normal and clear then the relay two "on" relays and one "off" relay (open floodgate). In this way, we no longer just have to rely on the operator to control the sluice gate, so that the water treatment process can be more optimal and efficient
Optimalisasi Faktor Daya dan Reduksi Rugi Daya Menggunakan Capacitor Bank Berbasis MATLAB Simulink Fatahilal Rasyid Agusta; Yenni Afrida; Fitriono Fitriono; Dasweptia D; Hamimi Hamimi; Jeckson son; Yudi Eka Putra
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 3 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n3.3092

Abstract

Abstract. Operation of electrical equipment with a low power factor results in increased current and reactive power, reducing efficiency and causing losses in the PLN distribution network. This study examines the capacitor bank requirements based on load measurements and power factor (cosΆ) for 52 three-phase low-voltage customers of PT PLN (Persero) ULP Karang. MATLAB simulations were used to determine the required capacity of the capacitor bank to increase the power factor above 0.85. The simulation results show that after installing capacitor banks, the average power factor increased to 0.99. Active power increased by 30.4% (from 76,638 watts to 99,970 watts), while reactive power decreased by 63% (from 65,768 VAR to 24,521 VAR). These improvements are expected to enhance the operational efficiency of electrical equipment with inductive loads and reduce power losses in the PLN network.
Sesame Oil with Butylated Hydroxyanisole as a Candidate Natural Ester for Transformer Insulation Afrida, Yenni; Maretha, Carla; Fitriono, Fitriono
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17036

Abstract

This study evaluates sesame oil modified with butylated hydroxyanisole (BHA) as a candidate eco-friendly transformer insulating liquid. Ten formulations were prepared using 500 mL sesame oil with 1-10 g BHA. Viscosity was measured using a rotational viscotester, and the laboratory-reported kinematic values were treated as estimates derived from the direct viscosity readings. Alternating-current breakdown voltage (BDV) was measured five times for each formulation, and differences among BHA loadings were evaluated using one-way analysis of variance. The estimated kinematic viscosity ranged from 33.33 to 42.59 cSt and generally decreased as BHA loading increased. The highest mean BDV was obtained at 3 g BHA/500 mL (30.24 +/- 7.94 kV), whereas the 10 g formulation showed the lowest estimated viscosity (33.33 cSt) and the second-highest BDV (25.58 +/- 3.38 kV). BDV exhibited a non-monotonic response to BHA loading. One-way ANOVA indicated significant differences among formulations (F(9,40)=7.98, p<0.001). The results identify 3 g BHA/500 mL as the most promising formulation in the current screening because it combined the highest dielectric performance with moderate viscosity. Further validation with BHA-free sesame oil, mineral-oil controls, independent formulation batches, measured density, moisture, acidity, and direct kinematic-viscosity testing is required before transformer application.