Orange Peel Waste as Natural Electrolyte for Bio-Batteries: Experimental Evaluation of Energy Storage Performance I Wayan Suriana; Ida Ayu Dwi Giriantari; Wayan Gede Ariastina; I Nyoman Setiawan
Advance Sustainable Science Engineering and Technology Vol. 8 No. 4 (2026): August-October
Publisher : Science and Technology Research Centre Universitas PGRI Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26877/asset.v8i4.2501

Abstract

This study aims to explore the potential of orange peel waste as an alternative electrolyte solution in environmentally friendly bio-battery systems. The significance of this research lies in the use of abundant and often discarded organic materials as active components for energy storage. Orange peel is extracted to obtain citric acid and bioactive compounds, then processed into an electrolyte gel to enhance ionic stability. Experimental methods were used to test the electrolyte performance in a Cu–Zn electrode configuration. The test results showed that the orange peel solution produced a maximum voltage of 0.9 V, while the gel formulation reached 1.0 V with voltage stability for up to 12 hours. The gel form showed better ionic conductivity and durability compared to the liquid solution. These findings confirm the potential of orange peel waste as a sustainable source of bioelectrolyte and support the application of circular economy in energy storage technology.
Analisis Konsumsi Energi Listrik dan Identifikasi Peluang Penghematan pada Gedung Pusat Kebugaran Galih Tri Prawira Harja; I Wayan Suriana; I Wayan Sukadana; I Wayan Sugara Yasa
Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim Vol. 5 No. 3 (2026): Ocean Engineering : Jurnal Ilmu Teknik dan Teknologi Maritim
Publisher : Fakultas Teknik Universitas Maritim AMNI Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58192/ocean.v5i3.5438

Abstract

Electrical energy is essential for supporting the operational activities of commercial buildings. Fitness centers have relatively high electricity consumption due to the use of air conditioning (AC), lighting, sports equipment, and other electrical devices that operate for long hours. LPD GYM Pemogan was selected as the study object because it operates daily with extended hours and various electrical loads. This study aims to determine the Energy Consumption Intensity (ECI), evaluate electrical energy use by comparing the ECI with applicable standards, and identify Energy Saving Opportunities (ESO). The research uses a quantitative descriptive method with an initial energy audit approach, using primary and secondary data on building conditions, electrical equipment, installed power capacity, building area, operating hours, electricity consumption, and electricity bills over six months. The analysis was conducted by calculating electricity consumption and ECI and comparing the results with reference standards. The average electricity consumption was 14,850 kWh/month, with a building area of 764.62 m². The ECI was 19.42 kWh/m²/month or 233.06 kWh/m²/year. Based on the ECI standard for air-conditioned buildings, the value is categorized as inefficient (wasteful), while it remains below the ASEAN-USAID benchmark. Energy savings can be achieved by optimizing AC temperature set points, regulating AC operation, and adjusting schedules according to room usage.
Simulasi Perancangan Tekno-Ekonomi Pembangkit Listrik Tenaga Surya (PLTS) Atap Sistem On-Grid dan Hybrid pada Sektor Rumah Tangga di Desa Tembok, Kecamatan Tejakula, Kabupaten Buleleng Menggunakan PVsyst Gede Yogi Wahyu Pratama; I Wayan Dikse Pancane; I Wayan Suriana
Indonesian Journal of Multidisciplinary on Social and Technology Vol. 4 No. 3 (2026): Juli - Oktober
Publisher : PT Ilmu Data Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.69693/ijmst.v4i3.14266

Abstract

Transisi energi sektor rumah tangga perdesaan dihadapkan pada tantangan variabilitas profil beban dan aturan Zero Export Peraturan Menteri ESDM Nomor 2 Tahun 2024, di mana daya surplus ke jaringan PLN tidak dihitung sebagai pengurangan tagihan. Penelitian ini bertujuan menganalisis kinerja teknis, neraca energi, dan kelayakan finansial 25 tahun dari perancangan Pembangkit Listrik Tenaga Surya (PLTS) atap sistem on-grid dan hybrid di Desa Tembok, Kabupaten Buleleng, Bali, serta mengevaluasi dampak optimasi geometri atap (tilt dan azimuth). Metodologi penelitian menerapkan pemodelan prediktif berbasis simulasi PVsyst 8.1.4 terhadap 15 rumah sampel yang mewakili variasi daya PLN (900 VA, 1300 VA, dan 2200 VA) dengan evaluasi 60 skenario kombinasi konfigurasi sistem dan geometri atap. Evaluasi finansial dianalisis menggunakan metode Discounted Cash Flow pada discount rate 6,0%. Hasil simulasi menunjukkan optimasi geometri atap meningkatkan penerimaan radiasi surya tahunan menjadi 2.056–2.074 〖"kWh/m" 〗^2 "/tahun" . Namun, ketiadaan kompensasi ekspor menyebabkan curtailment masif pada rumah tangga berbeban malam dan beban rendah, dengan energi terbuang (EUnused) membengkak hingga 82,5%–99,7%. Sebaliknya, sistem hybrid menekan EUnused hingga mendekati 0 kWh/tahun dan menaikkan Performance Ratio hingga 79,73%. Evaluasi finansial mengungkapkan hanya 2 dari 60 skenario (3,33%) yang dinyatakan layak ("NPV">0), yang seluruhnya berasal dari sistem on-grid sampel minimarket daya 2200 VA. Seluruh skenario hybrid dinyatakan tidak layak akibat tingginya investasi awal dan reinvestasi BESS LiFePO4 pada tahun ke-10. Disimpulkan bahwa dalam kerangka Zero Export, kelayakan ekonomi PLTS atap ditentukan oleh kesesuaian profil beban harian (load matching), sehingga perancangan disarankan beralih ke pendekatan Demand-Driven.