Claim Missing Document
Check
Articles

Found 13 Documents
Search

Multi-tuned Active Power Filter Based on p-q Theory for Power Harmonic Supression Moh. Jauhari; Kukuh Widarsono; Akhmad A. Kurdianto; Ciptian W. Priananda; Moch. Machmud Rifadil; Arman Jaya
IPTEK Journal of Proceedings Series No 3 (2019): International Conference on Engineering Technology Advance Science and Industrial Appli
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j23546026.y2019i3.5854

Abstract

The phenomenon of voltage and or current harmonic distortion often occurs in industrial electrical system. The harmonic distortion waveforms are caused by non-linear loads. Active power filters can reduce harmonic distortion on almost any harmonic order that appears. The p-q theory is a widely used method to calculate harmonic reference currents that required. This paper proposes an active power filter controlling method that can determine the desired harmonic order to be compensated specifically. Through this method, only the desired harmonic order will be compensated. This proposed method increases the effectiveness of p-q theory in the calculation of current harmonic suppression. the simulation results show that the proposed method can suppress the desired harmonics to be compensated, ie 3rd order from THD 30% to 0.46%, while in 5th order from 10% to 0.09%.
Meter Daya 1 Fasa Dengan Proteksi Over Voltage Dan Under Voltage berbasis Internet of Things (IoT) Endro Wahjono; Mochammad Machmud Rifadil; Ony Asrarul Qudsi; Muhammad Nur Sururi
INOVTEK - Seri Elektro Vol 2, No 2 (2020): INOVTEK Seri Elektro
Publisher : Politeknik Negeri Bengkalis

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35314/ise.v2i2.1384

Abstract

This research discusses about design and implementation of the power meters which are equipped with over or under voltage relays at 1 phase load based on internet of things (IoT). The power meters use power sensors that can detect active power values (P), apparent power (S), voltage (V), current (I), power factor (PF), frequency, energy, and total harmonic distortion (THD). Data on the power meter will be sent and stored in the database. Data on the power meters can also be monitored remotely via smartphones and personal computers using internet media. The power meters are equipped with indicators for over voltage, normal and under voltage conditions. This power meter is also equipped with a relay to disconnect the power at the load when there is interference with over voltage or under voltage on the system. From the results of tests that have been carried out, the relay will cut the load when there is interference with over voltage or under voltage on the system. Based on the results of testing that has been done, the design of the power meter made in this research had an average error of 0.0562% for resistive load and has the largest data readout error is 9.255% for non-linear load.
Alat Uji MCB 1 Fasa Instalasi Milik Pelanggan (IML) Karunia Vio Nita Rusyatul Ummah; S Sutedjo; Moch. Machmud Rifadil; Luki Septya Mahendra
Emitor: Jurnal Teknik Elektro Vol 22, No 2: September 2022
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23917/emitor.v22i2.19352

Abstract

MCB (Miniature Circuit Breaker) adalah bagian instalasi listrik yang berfungsi sebagai pengaman dalam instalasi listrik apabila terjadi beban berlebih atau arus hubung singkat. Untuk menghindari kegagalan fungsi MCB diperlukan pengecekan MCB terlebih dahulu sebelum dipasang pada pelanggan, selain itu juga untuk menghindari pencurian energi listrik oleh pelanggan yang tidak bertanggung jawab. Alat uji MCB ini menggunakan dimmer AC sebagai pengatur arus uji dan sebagai bebannya yaitu lampu halogen dan motor induksi 1 fasa. MCB akan diuji dengan arus uji sesuai dengan SPLN 108:1993. Dari pengujian MCB ini akan dibandingkan hasil waktu uji dengan SPLN, sehingga didapatkan MCB dalam kondisi baik atau tidak. Hasil pengujian MCB akan ditampilkan pada LCD untuk dijadikan sebagai Berita Acara sesuai dengan ketentuan perusahaan. Untuk mengatasi permasalahan tersebut maka dibuatlah alat uji MCB yang ringkas dan mudah digunakan sehingga diharapkan dapat mempermudah dalam menguji kelayakan MCB 1 Phase. Hasil pengujian alat uji MCB ini mampu menghasilkan arus uji 1,05In; 1,2In; 1,5In; 4In; dan 6In sesuai dengan SPLN 108:1993. Alat uji ini juga mampu menguji MCB 2A tipe CL sesuai dengan kondisinya dan didapatkan hasil 2 merk MCB dalam keadaan baik dan 1 merk MCB dalam keadaan buruk sesuai dengan SPLN 108:1993.
DESAIN DAN IMPLEMENTASI BUCK CONVERTER PADA SISTEM POWER SUPPLY UNTUK MESIN CUCI DENGAN MENGGUNAKAN PANEL SURYA Faisa Musahiroh
Jurnal Teknologi Terpadu Vol 11, No 1 (2023): JTT (Jurnal Teknologi Terpadu)
Publisher : Pusat Penelitian dan Pengabdian Kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32487/jtt.v11i1.1506

Abstract

Dalam makalah ini akan dijelaskan dan disimulasikan mengenai rangkaian buck converter sebagai penstabil tegangan menggunakan software MATLAB. Dimana sumber dari buck converter ini menggunakan panel surya sebesar 50 WP sebanyak 4 buah yang dipasang secara paralel. Keluaran dari buck converter yaitu langsung menuju beban berupa mesin cuci sebesar 12 VDC/200 Watt. Sistem disini menggunakan metode constant voltage. Dimana untuk mencapai tegangan yang konstan ini menggunakan kontrol logika fuzzy. Metode constant voltage ini dipilih dikarenakan metode ini yang paling sesuai dengan karakteristik secara umum. Selain itu juga dengan metode ini akan mengurangi resiko cepat panasnya pada beban selama proses penggunaan. Sehingga, dengan metode ini akan menambah umur beban. Dalam proses simulasi ini akan dilihat nilai tegangan yang dihasilkan selama proses. Pada simulasi juga dapat dilihat pengaruh dari kontrol fuzzy yang menyebabkan tegangan sesuai dengan set point. Hasil dari makalah ini pada sistem power supply dilakukan dengan satu tahapan yaitu untuk memperoleh tegangan konstan sebesar 12 Volt.
Penyeimbangan Beban Sistem Kelistrikan Tiga Fasa Berbasis Fuzzy Logic Aji Ragasukma Sutejo; Sutedjo Sutedjo; M Machmud Rifadil; Regina Salsabila
TELKA - Jurnal Telekomunikasi, Elektronika, Komputasi dan Kontrol Vol 9, No 1 (2023): TELKA
Publisher : Jurusan Teknik Elektro UIN Sunan Gunung Djati Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15575/telka.v9n1.1-8

Abstract

Ketidakseimbangan beban pada suatu sistem distribusi tenaga listrik selalu terjadi dikarenakan pembagian beban satu fasa tidak merata. Membiarkannya dalam waktu lama akan menyebabkan arus netral. Ketidakseimbangan beban ini terjadi karena adanya perbedaan nilai arus yang signifikan pada setiap fasanya. Untuk mengatasi ketidakseimbangan beban yang berlebihan maka kami membuat penelitian penyeimbangan beban sistem kelistrikan tiga fasa berbasis Fuzzy Logic yang telah dirancang dengan standar ketidakseimbangan beban 5% menurut IEC yang membandingkan arus setiap fase. Logika Fuzzy mempunyai efek mendeteksi fasa dengan arus seperti saat fasa R mempunyai arus yang lebih banyak dari fasa yang tersisa. Relai akan memberikan efek memutus beban fasa R dengan skala prioritas terendah terlebih dahulu. Sebelum dilakukan penyeimbangan beban hasil presentase ketidakseimbangan beban sebesar 7.34%. Tindakan penyeimbangan beban membuat ketidakseimbangan beban menjadi 2.39%. Nilai ini sudah memenuhi standar ketidakseimbangan beban dari IEC. Load imbalance in an electric power distribution system always occurs due to the uneven distribution of single-phase loads. Leaving it on for a long time will cause a neutral current. This load imbalance occurs because there is a significant difference in the current value of each phase. To overcome excessive load imbalance, we conducted a study on balancing a three-phase electrical system based on Fuzzy Logic which has been designed with a 5% load imbalance standard according to the IEC, which compares the currents of each phase. Fuzzy logic detects phases with currents, such as when phase R has more current than the remaining phases. The relay will have the effect of breaking the R phase load with the lowest priority scale first. Prior to load balancing, the percentage of load imbalance was 7.34%. The load balancing action brings the load unbalance to 2.39%. This value meets the IEC load unbalance standard.
Rancang Bangun Prototipe Rumah DC Sistem Off Grid Berbasis Fuzzy Logic Regina Salsabila; Sutedjo Sutedjo; Moch. Machmud Rifadil
Indonesian Journal of Engineering and Technology (INAJET) Vol. 5 No. 2 (2023): April 2023
Publisher : Fakultas Teknik Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/inajet.v5n2.p54-61

Abstract

Indonesia memiliki potensi yang besar sebagai penghasil sumber energi terbarukan, salah satunya energi surya. Energi surya tidak selalu menghasilkan daya yang stabil, hal ini dikarenakan kontiniutas energi yang bergantung pada siklus dan kondisi iklim. Untuk terjaganya kontiniutas energi maka, pada proyek akhir ini dirancang Prototype Rumah DC 200 watt dengan tujuan konsep rancangan tersebut dapat digunakan pada Rumah DC. Rumah DC menggunakan sumber panel surya yang nantinya akan terhubung ke SEPIC konverter yang berfungsi sebagai charging battery dengan tegangan output 14,4 V untuk charging baterai dengan tegangan input 18 V dari solar panel akan diturunkan tegangannya melalui SEPIC konverter sesuai dengan nilai duty cycle yang diatur pada mosfet untuk mengisi daya baterai sesuai dengan perhitungan kebutuhan beban baterai lead acid 12V/140 Ah. Sistem charging battery menggunakan metode CV (constant voltage) dengan diberikan algoritma fuzzy logic. Hasil dari proyek akhir dengan cara simulasi pada SEPIC konverter telah dikontrol menggunakan algoritma fuzzy dengan metode charging constant voltage, set point 14,4 V sehingga dengan algoritma fuzzy dapat digunakan untuk charging baterai. Pada pengujian hardware, tegangan charging baterai dapat dikontrol menggunakan logika fuzzy dengan tegangan charging rata - rata 14,4 V dengan keadaan iradiasi yang berbeda. Oleh karena itu desain ini dapat digunakan untuk Rumah DC 12 V/200 watt
Pertumbuhan Akar Anggrek Bulan Melalui Sistem Tanam Hidroponik dalam Smart and Aesthetic Greenhouse Ayu Ratna Permanasari; Harita Nurwahyu Chamidy; Robby Sudarman; Dianty Rosirda; Mochammad Machmud Rifadil; Wahyu Wibisono
Jurnal Serambi Engineering Vol. 9 No. 4 (2024): Oktober 2024
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Hydroponic orchid (Phalaenopsis) growing is a modern agricultural technique that is growing in popularity due to its ability to produce high quality orchid plants with efficient use of resources. Hydroponics is an agricultural method that does not use soil media, but rather nutrient solutions specially formulated to meet the nutritional needs of plants. In orchid cultivation, hydroponics offers several advantages, including more precise nutrient control, a more sterile growing environment, and a reduced risk of soil-borne pests and diseases. The aim of this study was to investigate the effectiveness of the hydroponic method in orchid cultivation, focusing on vegetative growth, flower quality and the efficiency of water and nutrient use. The results of the study showed that orchids grown hydroponically had faster growth and better flower quality compared to conventional methods. The average growth of orchid roots in the aquaponic system was 2mm per week and the growth of orchid roots without hydroponics was approximately 1.3mm per week.
A Hardware Implementation of SEPIC Converter Using ANFIS for Water Flow Control Adila, Ahmad Firyal; Sutedjo, Sutedjo; Mahendra, Luki Septya; Habibi, Muhammad Nizar; Rifadil, Mochammad Machmud; Putri, Ghodah Haifa
ROTASI Vol 26, No 2 (2024): VOLUME 26, NOMOR 2, APRIL 2024
Publisher : Departemen Teknik Mesin, Fakultas Teknik, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/rotasi.26.2.45-52

Abstract

Water resources are one of the needs for the continuation of life. The majority of people in Indonesia still use a manual water tank filling system, so it requires regular checks. Filling the water tank manually is ineffective because it requires turning on and off the pump first so the use of electrical energy is increasingly wasteful. In this research, a water flow control system was developed to fill water tanks, making it easier to use water both at home and in public facilities. This water flow control system uses a Single Ended Primary Inductor Converter (SEPIC) Converter as a DC motor pump supply voltage regulator. The SEPIC converter has the advantage of being able to increase and decrease the voltage value without changing the polarity. The duty cycle settings on the SEPIC converter are regulated using the Adaptive Neuro-Fuzzy Inference System (ANFIS) control method. The water flow control settings in this system use feedback from the water flow sensor by utilizing the hall effect. Based on simulations and implementation that have been carried out using MATLAB as well as hardware testing, at a set point value of 1.5 liters/minute the output voltage value is 3.9 V, and at a set point value of 3 liters/minute the output voltage value is 6.8 V. Implementation of ANFIS control has proven to be a solution for regulating voltage and has worked more efficiently on loads.
Design and Simulation of Single Input Double Output Coupled Inductor Boost Converter with Bisection Method for Independent Home Application Sudiharto, Indhana; Rifadil, Mochammad Machmud; Romadhoni, Muhammad Fauzi; Milchan, Muhamad
Jurnal Rekayasa Elektrika Vol 20, No 4 (2024)
Publisher : Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17529/jre.v20i4.34086

Abstract

This paper proposed a converter design that functions as a voltage booster, increasing the input voltage while supplying two load outputs from a single voltage input using only one switch. Known as a single input double output (SIDO) converter, it aims to enhance power efficieny. The bisection method is employed as an output voltage controller through pulse width modulation (PWM) to achieve an optimal voltage value, adjusted to meet the load requirements. The loads used for independent home applications include a 72 V/12 Ah battery and a 24 V/22 W water circulation pump. The output of the high voltage level acts as a battery charger while the output of the low voltage level serves as an energy supply for the water cir-culation pump. The two loads were chosen because they are widely used, aligning with the goal of realizing independent home applications. The simulation test results showed that the voltage output for battery charging in constant voltage mode was 80.6 V, with an error of 0.0515%, and the voltage output for the water circulation pump was 24 V, with an error of 0.33%.
Sistem Pengisian Baterai Konstan Tegangan Berbasis Fuzzy Logic Pada Aplikasi Off Grid Rumah DC Nisa, Karimatun; Salsabila, Regina; Rifadil, Moch Machmud; Sutedjo, Sutedjo; Mahendra, Luki Septya
ELECTRA : Electrical Engineering Articles Vol. 3 No. 2 (2023)
Publisher : UNIVERSITAS PGRI MADIUN

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25273/electra.v3i2.15711

Abstract

Pada penelitian yang diusulkan dirancang Rumah DC dengan kapasitas daya 200 watt. Rumah DC berisikan beban – beban rumah tangga DC. Panel surya digunakan sebagai sumber dari Rumah DC. Konverter daya yaitu SEPIC terhubung dengan panel surya yang berfungsi sebagai pengisian baterai dengan tegangan keluaran sebesar 14,8 V . Luaran tegangan panel surya adalah 18 V, dari panel surya akan diturunkan tegangannya melalui SEPIC konverter sesuai dengan nilai duty cycle yang diatur pada mosfet untuk mengisi daya baterai sesuai dengan kebutuhan beban baterai lead acid 12V/140 Ah. Sistem pengisian baterai yang digunakan adalah  metode constant voltage (CV) dengan diberikan algoritma fuzzy logic. Simulasi yang akan disajikan yaitu SEPIC telah dikontrol menggunakan algoritma fuzzy dengan metode CV dengan set point 14,8 V , sehingga dengan algoritma fuzzy digunakan untuk control pengisian baterai. Sedangkan pada pengujian alat, tegangan pengisian baterai dapat dikontrol menggunakan logika fuzzy yaitu dengan rata – rata tegangan pengisian 14,8 V  dengan iradiasi yang bervariasi. Oleh karena itu desain ini dapat diaplikasikan pada Rumah DC 12 V/200 watt.Â