Claim Missing Document
Check
Articles

Found 24 Documents
Search

Green Technology of Processing Chicken Egg Shell Waste into Nanocalcium for Osteoporosis Prevention: A Literature Study Sunardi
Jurnal Serambi Engineering Vol. 9 No. 3 (2024): Juli 2024
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Egg shells have a high enough calcium content which can.be used as a source of calcium. The elderly population is increasing globally and is predicted to reach 1.5 billion by 2050. The quality of life of the elderly must be considered, for example by developing functional foods for the elderly. This literature review will discuss the development of functional foods to reduce the risk of osteoporosis in the elderly. Oxidative stress is one of the factors that accelerates the occurrence of osteoporosis. Various antioxidants, including vitamin C, vitamin E, polyphenols, or lycopene, have been shown to have antioxidant activity, thereby reducing the risk of osteoporosis. In addition, the application of nanocalcium from chicken egg shells in various food products has been reported to increase calcium intake, and its use is environmentally friendly because it can contribute to reducing food waste. The application of antioxidants and nanocalcium can be a good combination, but the amount of some antioxidants must be considered so as not to interfere with calcium bioavailability. Therefore, this literature review aims to explore functional foods for the elderly to reduce the risk of osteoporosis, especially with antioxidants and nanocalcium from chicken egg shells. Eating preferences and eating patterns of the elderly are also a consideration to determine the appropriate form of functional food for the elderly. The results presented in this literature review can be the basis for the development of new food products enriched with nanocalcium from chicken egg shells for the elderly.
Treating Waste with Waste : Utilization of Iron Powder for the Reduction of Chromium (Cr6+) in Metal Plating Industry Liquid Waste Sunardi
Jurnal Serambi Engineering Vol. 9 No. 3 (2024): Juli 2024
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Metal plating industry waste is the main source of environmental pollution due to heavy metal chromium(Cr6+). The method commonly used in processing chromium metal waste (Cr6+) in industry is by means ofreduction and coagulation. Chromium metal (Cr6+) is highly toxic because it is highly unstable comparedto chromium (Cr3+). Therefore, chromium waste (Cr6+) must be reduced to chromium (Cr3+) before beingdischarged into the environment. The purpose of the study is to reduce the content of chromium ions (Cr6+)in liquid waste of the metal coating industry by the reduction and coagulation process using waste ironpowder and calcium hydroxide. Liquid chromium waste (Cr6+) and iron powder waste are taken from the metal coating industry in Palur Karanganyar, Central Java. Iron waste is in the form of powder that comesfrom the sanding process that is no longer used. The parameters studied were the weight of iron powder, the addition of H2SO4 2N, and the reduction time. The measurement of chrom ion levels (Cr6+) in all treatments was determined by UV-Vis Spectroscopy. The results of the study showed that the chromium level (Cr 6+) of liquid waste of the metal coating industry was 749 mg/L. Theoptimum condition for reducing chromium (Cr6+) is to use 3 gr iron powder, 10 ml of H2SO4 2N, and a reduction time of 7 minutes there is a decrease in chromium (Cr6+) levels by 100% with a chromium level (Cr6+) of 0 mg/L. This result meets the Regional Regulation of Central Java Province Number 5 of 2012 concerning Liquid Wastewater Quality Standards for the Metal Plating Industry which requires a maximum chromium level (Cr6+) of 0.1 mg/L.
Sintesis dan Karakterisasi Pupuk Lepas lambat Fe-Zn dari Limbah Besi, Limbah Seng, dan Cangkang Telur Ayam Rosy Dwi Rahmawati; Sunardi
Jurnal Serambi Engineering Vol. 9 No. 3 (2024): Juli 2024
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The synthesis of slow-release Fe-Zn fertilizer from community waste, using iron waste, zinc waste, and chicken eggshells as raw materials, aims to transform underutilized waste into economically valuable products. The study investigates three fertilizer compositions for the ratios 1:1:1, 1:1:2, and 2:1:1 (FeSO4 : CaCO3 : ZnSO4). The synthesis process involves mixing FeSO4, CaCO3, and ZnSO4 with distilled water. After mixing, the fertilizer is dried and characterized using FTIR (Fourier Transform Infrared Spectroscopy) and SEM (Scanning Electron Microscope) - EDS (Energy Dispersive Spectroscopy). SEM analysis reveals irregularly shaped Fe-Zn slow-release fertilizers with uneven surfaces. FTIR results show similar spectral regions among the three variations. The presence of CaO is indicated by absorption bands at 709.80 cm-1, while Zn-O-H bonds appear at 1,070 cm-1. Fe-O bonds are identified at 692 cm-1
Analysis of COD and BOD5 at the Inlet and Outlet of the Wastewater Treatment Plant (WWTP) at Hospital X Sunardi; Fakhrizal Falah; Argoto Mahayana; Sumardiyono; Nur Hidayati; Soebiyanto; Mahardira Dewantara
Jurnal Serambi Engineering Vol. 9 No. 4 (2024): Oktober 2024
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Hospitals are one of the service facilities that produce large amounts and quality of liquid waste that requires special attention because it contains hazardous materials for public health and the environment. This study aims to determine the quality of COD and BOD effluents in X Hospital. The type of research used is observational with a descriptive approach. The sampling technique used was purposive sampling, where wastewater samples were taken from two points, namely the inlet and the outlet of the WWTP. Based on the results of the laboratory analysis of the wastewater samples from Hospital X, it can be concluded that the average COD value at the inlet of the WWTP was 64.04 mg/L, while the average COD value at the outlet of the WWTP was 47.90 mg/L, and the average BOD value at the inlet was 12.69 mg/L, while the average BOD value at the outlet was 1.60 mg/L. All of these values are qualified according to the Hospital Activity Liquid Wastewater Quality Standards based on Central Java Province Regional Regulation No. 5 of 2012. It is expected that Hospital X will continue to maintain the wastewater treatment plant.