Claim Missing Document
Check
Articles

Found 10 Documents
Search

PEMANFAATAN REFLEKTOR UNTUK PENINGKATAN DAYA LUARAN PANEL SURYA Isdawimah *; Nuha Nadhiroh; Muchlishah *; Dezetty Monika; Arum Kusuma Wardhany; Ajeng Bening Kusumaningtyas
Jurnal Poli-Teknologi Vol. 21 No. 3 (2022)
Publisher : Politeknik Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32722/pt.v21i3.4723

Abstract

The Government of Indonesia has committed to support the development of solar power plant, while the efficiency of solar panels still around 5-16%. There are several methods to increase the output power of solar panel, but mostly consume a big portion of energy from solar power plant. The objective is to identify an off-grid solar power plant optimization method with smaller power consumption. The proposed optimization method is to add a reflector that can be positioned to direct sunlight so that it always hits the solar panel, so that the solar panel is able to produce electrical power optimally. This method can save the use of electrical power, because the weight of the reflector is much lighter than solar panels. The position of the reflector can be adjusted automatically based on feedback from the monitoring system. Off Grid solar system consisting of solar panels, batteries, solar charge controller (SCC), inverters, safety against overloads, short circuits and lightning strikes and mounted reflectors that can be adjusted in position, so that a lot of sunlight hits the solar panels so that the solar panel output power increase. In choosing the type of reflector, several things need to be considered, namely weight, refractive index, size, shading effect and the reflector's resistance to wind, impact and shock. Data retrieval is carried out automatically with a monitoring system to measure and store data when testing solar power system without reflectors and with reflectors in various positions. Data retrieval is based on IEC Standard 61724, while data processing is based on IEA-PVPS T2-01, 2000. Installing reflectors on solar panels is proven to increase the output power of solar panels, where aluminum reflectors and flat mirrors produce the greatest output power at an angle of 83°. Flat mirror reflectors produce a greater increase in solar panel output power compared to flat aluminum reflectors
PENERAPAN IEEE 519-2014 TERHADAP IDENTIFIKASI DISTORSI HARMONISA PADA TRANSFORMATOR 3 FASA Wardhany, Arum Kusuma; Monika, Dezetty; Gumilar, Langlang
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.835

Abstract

Transformator merupakan peralatan yang paling merasakan adanya harmonik, karena letaknya yang lebih dekat terhadap beban. Pada transformator, harmonik arus (THD% I) akan menyebabkan peningkatan rugi-rugi tembaga (Cu), sedangkan harmonik tegangan (THD% V) menyebabkan peningkatan rugi-rugi arus Eddy (Eddy Current) sehingga terjadi kerugian daya dan peningkatan temperatur. Pada penelitian ini dilakukan untuk mengetahui gangguan harmonik pada transformator 3 phasa dari pemakaian beban non linier dengan cara mengidentifikasi tingkat dominan harmonik, THD % arus maupun tegangan, peningkatan temperatur dan estimasi kerugian daya yang dimonitoring secara real-time menggunakan software IoT Blink. Hasil pengujian menunjukkan bahwa harmonisa arus pada transformator 3 phasa menimbulkan rugi – rugi tembaga (Cu) sebesar 0,0424 pu (setara 57,98 W) dan rugi arus eddy sebesar 0,0370 p.u (setara 50,60W).
OPTIMASI SISTEM PEMBUMIAN DENGAN PENERAPAN METODE ROD DAN ZAT BENTONITE : STUDI KASUS DI POLITEKNIK NEGERI JAKARTA Wardhany, Arum Kusuma; Aji, Anicentus Damar; Maydioputra, Muhammad Reyhan; Irawan, Adi; Putra, Yudi Utomo
INTEKNA Jurnal Informasi Teknik dan Niaga Vol 23 No 2 (2023): Jurnal INTEKNA, Volume 23, No. 2, Nov 2023
Publisher : P3M Politeknik Negeri Banjarmasin

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sistem pembumian merupakan komponen penting dalam instalasi listrik yang bertujuan untuk mengalirkan arus ke bumi secara aman, serta melindungi perangkat dan pengguna dari potensi bahaya listrik. Generator adalah satu contoh peralatan yang perlu diamankan dengan menggunakan sistem pembumian. Persyaratan Umum Instalasi Listrik tahun 2011 (PUIL 2011) telah menetapkan bahwa standar nilai tahanan pembumian kelistrikan di Indonesia sebesar <5ohm. Pengukuran sistem pembumian pada peralatan generator set (genset) di Politeknik Negeri Jakarta didapati bahwa nilai tahanan sistem pembumian melebihi standar yang telah ditetapkan yaitu sebesar 16,524 ohm. Penelitian ini dilakukan untuk memperbaiki nilai tahanan sistem pembumian agar memenuhi standar PUIL. Metode yang digunakan dalam penelitian ini yaitu metode rod, yang diawali dengan melakukan simulasi perhitungan untuk menentukan nilai jarak, kedalaman pemasangan dan ketebalan elektroda baru untuk menghasilkan nilai tahanan baru yang diinginkan. Setelah nilai dari parameter didapatkan, elektroda baru akan dihubungkan secara parallel dengan elektroda pembumian yang sudah ada, kemudian sekitar area pembumian akan ditambahkan dengan bentonite untuk menyerap air dan menahan air pada strukturnya. Hasil analisa rancangan didapatkan bahwa elektroda baru akan dipasang dengan jarak antar titik sejauh 5 meter, kedalaman pemasangan rod 25 meter dan ketebalan rod 5/8”. Hasil pengukuran didapatkan bahwa nilai tahanan elektroda baru sebelum diparalelkan adalah 3,447 ohm. Setelah kedua elektroda dihubungkan secara parallel, nilai tahanan pembumian pada lokasi terpasang sebesar 2,853 ohm.
SISTEM PENGENDALIAN RESISTANSI PEMBUMIAN OTOMATIS DAN AKURASI PENGUKURAN DENGAN ELEKTRODA GROUNDING GRID PADA PLTS Wardhany, Arum Kusuma; Isdawimah; Iskandar, Gilang Maulana; Juliansyah, Muhammad Fitra
INTEKNA Jurnal Informasi Teknik dan Niaga Vol 24 No 2 (2024): Jurnal INTEKNA, Volume 24, No. 2, Nov 2024
Publisher : P3M Politeknik Negeri Banjarmasin

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pengukuran dan pengendalian resistansi pembumian merupakan aspek penting dalam menjaga keamanan dan keandalan sistem tenaga listrik, terutama pada instalasi Pembangkit Listrik Tenaga Surya (PLTS). Pada penelitian ini, dikembangkan sistem pengendalian resistansi pembumian otomatis dengan memanfaatkan metode 3-pole-fall-of-potential. Sistem ini menggunakan sensor INA219 untuk mengukur arus dan modul ADS1115 untuk mengukur tegangan. Sistem ini juga dilengkapi mekanisme penyuntikan air secara otomatis untuk menjaga kelembaban tanah dan menurunkan resistansi ketika melebihi ambang batas yang ditentukan, yaitu 5 ohm dengan histeresis ±0,25 ohm. Sistem pengendalian besar resistansi berfungsi sesuai dengan yang direncanakan,yaitu secara manual dan otomatis. Dengan akurasi pengukuran menunjukkan bahwa sistem yang dikembangkan memiliki rata-rata akurasi sebesar 92,79% dengan persentase kesalahan rata-rata sebesar 7,21%, dibandingkan dengan alat ukur Earth Tester. Selain itu, penambahan air terbukti efektif dalam menurunkan resistansi tanah, terutama pada pengujian awal dengan penurunan resistansi sebesar 7,55% menggunakan sistem. Hasil penelitian ini menunjukkan bahwa sistem pengendalian resistansi pembumian otomatis ini efektif dalam menjaga resistansi tanah sesuai persyaratan yang berlaku, serta memberikan kemudahan bagi operator dalam pengoperasian dan pemantauan melalui antarmuka IoT.
Performance Analysis of Micro-Hydro Plants Using Crossflow Turbines at Varying Water Fall Heights Wardhany, Arum Kusuma; Monika, Dezetty; Ariansyah, Rafi; Lubis, Muhammad Rasyid; Arifin, Muhammad; Aji, A. Damar
Emitor: Jurnal Teknik Elektro Vol 25, No 1: March 2025
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23917/emitor.v25i1.7067

Abstract

Hydropower plants have limitations in scalability and location, as they require large water flows and complex infrastructure. One solution to overcome these drawbacks is portable hydroelectric power plants, which are more flexible and adaptable to variations in water level. Portable geothermal power plants allow the regulation of water fall height to optimise their performance, especially in remote areas that are not reached by conventional power grids. This research aims to develop the performance of portable geothermal power plants by utilising variations in water level to analyse the performance of the effect of water fall height on the performance of portable geothermal power plants with crossflow turbines. This research uses an experimental method, which involves collecting and analysing data from the height of (variation 1) and (variation 2) to determine the performance of the Pico Hydro Power Plant (PLTPh). The research was conducted at Mahogany Lake, University of Indonesia. The data collected includes measurements of voltage, current, power, and rotation speed of the turbine and generator at different altitude variations to determine the effect of water fall height on the performance of PLTPh with crossflow turbines. The results showed that the height of the water fall can affect the performance of the Pico Hydro Power Plant (PLTPh). At the height (variation 1), the power and output voltage generated are higher than the height (variation 2). In addition, the output voltage is also greater when the generator is operating without load. This difference shows that variations in altitude, flow speed and water discharge entering the turbine cross section greatly affect the rotation of the generator and the amount of electrical power generated by the PLTPh.
Penerapan Penerangan Jalan Umum Tenaga Surya Dengan Kendali Otomatis Pada Kampung Setaman Untuk Mewujudkan Ketahanan Energi Wardhany, Arum Kusuma; Dwiyaniti, Murie; Nadhiroh, Nuha; Setiana, Hatib; Widjayanto, Danang
Mitra Akademia: Jurnal Pengabdian Masyarakat Vol 7 No 1 (2024): Mitra Akademia: Jurnal Pengabdian Masyarakat
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32722/mapnj.v7i1.6364

Abstract

Kampung Setaman is one of the Climate Village (Proklim) prototypes, with work programs on greening and environmental planning, waste management, food and energy sustainability, and other community activities contributing to public resilience to climate change. Almost all of these work programs have been implemented privately, except for the energy sustainability work program, which promotes the use of renewable energy sources due to financial constraints. The lighting conditions on public street lights in Kampung Setaman continue to rely primarily on PLN sources sourced from nearby public houses, burdening the public's electricity bills. PS-TOLI conducted public service activities in the form of PJU-PLTS installation to solve the problem. Three (3) public street lighting point were installed using a PLTS source. The light is controlled automatically by a microcontroller based on the amount of sunlight and traffic density. Lamp lights can be dimmed as needed to conserve battery power. The PJU-PLTS performance test involves testing the output of the PLTS system as well as the automatic performance of the lighting lamp. In addition to the installation of street lights, the village community receives training in New and Renewable Energy as well as street lamp maintenance. It is hoped that the public will be encouraged to use PLTS as an alternative to electricity.
PEMBANGKIT LISTRIK TENAGA PIKOHIDRO MENGGUNAKAN TURBIN PELTON Wardhany, Arum Kusuma; Trianto, Andri; Salman Wilestar, Inggil Kholillulloh; Sakerebau, Karmila
INTEKNA Jurnal Informasi Teknik dan Niaga Vol 25 No 1 (2025): Jurnal INTEKNA, Volume 25, No. 1, Mei 2025
Publisher : P3M Politeknik Negeri Banjarmasin

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pembangkit Listrik yang memanfaatkan tenaga air seperti pikohidro (pico hydro) merupakan salah satu pembangkit yang potensial untuk dikembangkan secara mandiri. Rentang kapasitas daya luaran 0 – 5 kW dari pembangkit ini memungkinkan untuk dipasang pada saluran kecil berupa saluran irigasi. Penelitian ini bertujuan untuk mengembangkan trainer kit Pembangkit Listrik Tenaga Pikohidro (PLTPH) menggunakan turbin Pelton sebagai media pembelajaran bagi mahasiswa. Turbin Pelton dipilih karena cocok diaplikasikan pada aliran air kecil dengan tekanan tinggi, yang banyak ditemukan pada PLTPH. Alat ini memanfaatkan air yang disemprotkan ke turbin untuk menghasilkan energi listrik melalui generator. Pengujian dilakukan untuk mengevaluasi pengaruh sudut valve terhadap kecepatan turbin, tegangan, dan arus listrik yang dihasilkan. Hasil menunjukkan bahwa sudut valve 0° memberikan kinerja maksimal, dengan RPM dan tegangan tertinggi sebesar 895 Rpm, dan 23,25 volt pada kondisi tanpa beban, sedangkan arus meningkat saat beban ditambahkan. Trainer kit ini diharapkan dapat memberikan pemahaman praktis tentang energi terbarukan kepada mahasiswa.
Penyiram Tanaman Hidroponik Otomatis Berbasis IoT Dengan PLC Outseal Dan ESP32 Nadhiroh, Nuha; Wardhany, Arum Kusuma; Setiana, Hatib; Renaldy, Raihan; Putri, Amanda Alifya; Handayani, Mutiara Dwi
Electrices Vol 6 No 1 (2024): Volume 6 Nomor 1 Tahun 2024
Publisher : Jurusan Teknik Elektro, Politeknik Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32722/ees.v6i1.6361

Abstract

Proses penyiraman pada tanaman hidroponik adalah salah satu unsur penting dalam tumbuh kembang tanaman, tanaman membutuhkan air agar tetap terus tumbuh dengan baik. Kurang efisien nya penyiraman tanaman dengan cara manual menjadikan tanaman tidak terawat karena kebutuhan air yang tidak tercukupi ataupun melebihi kecukupan pada tanaman. Untuk menjaga tumbuh kembang pada tanaman dibutuhkan sistem monitoring yang dapat memantau kelembaban tanah untuk memastikan tanaman mendapatkan asupan air yang cukup. Beberapa komponen yang digunakan diantaranya adalah sensor kelembaban tanah, sensor level air pada tangki, motor pompa dan valve. Penelitian ini menggunakan metode experimental yang kemudian divalidasi dengan implementasi langsung pada kebun hidroponik. Penerapan sistem kontrol penyiram tanaman hidroponik otomatis dengan PLC Outseal digunakan untuk mengatur kontrol pompa penyiraman dan pompa sumur berdasarkan pembacaan sensor yang akan mengoptimalkan penyiraman sesuai dengan kebutuhan tanaman dan dapat termonitoring dari jarak jauh dengan melihat hasil pembacaan sensor melalui aplikasi Blynk pada smartphone. Hasil penelitian menunjukkan bahwa sistem dapat bekerja sesuai deskripsi apabila kelembaban dibawah 3300 maka pompa penyiraman akan mati, dan apabila kelembaban diatas 3300 maka pompa akan hidup, waktu kecepatan penerimaan data pada Blynk selisihnya sekitar 1 detik.
Skillion Roof Design to Get Optimum Solar Radiation in Yogyakarta Putra, Yudi Utomo; Asnawi, Rustam; Wardhany, Arum Kusuma
Jurnal Edukasi Elektro Vol. 7 No. 2 (2023): Jurnal Edukasi Elektro, Volume 7, Nomor 2, 2023
Publisher : DPTE FT UNY

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21831/jee.v7i2.65953

Abstract

Electrical energy is energy that cannot be released from daily activities at home, all elec-tronic equipment requires electrical energy, one source of electrical energy is the electrici-ty company PT. PLN (Persero) and as an alternative source of electrical energy, a home can use solar panels installed on the roof as a small scale power generator or can be called Solar Home System (SHS), but electrical energy obtained is very dependent on the radia-tion received by the solar panels, therefore, to obtain optimum solar radiation, it is neces-sary to calculate the azimuth angle and tilt angle which can be used as a reference for in-stalling solar panels. So mathematical calculations are needed to calculate the maximum azimuth angle and tilt angle. Mathematical modeling is used to calculate solar energy in-stalled at coordinates 7.7° south latitude, in that coordinate, average solar radiation can get from Meteorological, Climatological, and Geophysical Agency on horizontal surface, then calculation the declination angle, latitude angle, hour angle, azimuth angle and tilt angle to get value of incidence angle. Value of the declination angle, latitude angle, and hour angle are constant, while the azimuth angles divide into four directions, it's 0°, 90°, 180°, and 270° and the tilt angles are 20°, 25°, and 30° on skillion roof design. The results of the calculation and analysis of the movement of the sun for one year show that, by calculating the average solar radiation in a year, the roof of the house in the form of a skillion with an azimuth angle in the 0° gets the most optimal solar energy at an angle of 20° with an aver-age solar radiation of 442,96 W/m2 in one year.
Simulation of Automatic Solar Tracker Control System Using Proteus Application Efendi, Erwan Tri; Wibowo, Bayu Setyo; Dhiyaussalam, Dhiyaussalam; Wardhany, Arum Kusuma; Wibisono , Arifin
Eksergi Vol. 20 No. 03 (2024): SEPTEMBER 2024
Publisher : Politeknik Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32497/eksergi.v20i03.6360

Abstract

As a tropical country, Indonesia possesses significant renewable energy potential, particularly from solar and wind sources. However, seasonal variations—such as high solar intensity during the dry season and increased wind speeds during the rainy season—pose challenges to optimizing solar cell utilization. While solar energy presents an ideal solution for clean energy transition, static photovoltaic (PV) systems suffer from efficiency limitations due to their inability to track the sun’s movement. Dual-axis solar trackers can enhance energy efficiency by 25–35% compared to fixed systems, particularly in tropical regions with dynamic solar positioning. However, large-scale physical implementation requires substantial investment, making simulation tools like Proteus essential for computational validation prior to real-world deployment. Proteus facilitates comprehensive modeling of LDR sensors, servo motors, and microcontroller-based control algorithms (e.g., Arduino) in a precise virtual environment. This approach also evaluates the impact of tropical conditions (e.g., humidity, rainfall) on system reliability while optimizing designs to reduce costs. Integrating current research with Proteus simulations offers a robust methodology to accelerate solar tracker adoption in Indonesia.