Claim Missing Document
Check
Articles

Found 8 Documents
Search
Journal : Journal of Science Innovare

DEVELOPMENT OF COD (CHEMICAL OXYGEN DEMAND) ANALYSIS METHOD IN WASTE WATER USING UV-VIS SPECTROPHOTOMETER Uswatun Hasanah; Ade Heri Mulyati; Sutanto .; Diana Widiastuti; Siti Warnasih; Yulian Syahputri; Tri Panji
Journal of Science Innovare Vol 3, No 2 (2020): Journal of Science Innovare
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33751/jsi.v3i2.3007

Abstract

The COD (Chemical Oxygen Demand) analysis method based on the Indonesian National Standard (SNI) is a revision of SNI 06-6989.2-2004, Water and wastewater - Part 2: Method of testing for chemical oxygen demand (COD) with closed reflux spectrophotometrically. This SNI uses references from international standard methods, namely Standard Methods for the Examination of Water and Wastewater, 21st Edition, editor of LS Clesceri, AE Greenberg, AD Eaton, APHA, AWWA and WEF, Washington DC, 2005, Methods 5220 D (Closed Reflux, Colorimetric Methods). The purpose of this study was to validate the total method for testing chemical oxygen demand (COD) in water and wastewater with the reduction of Cr2O7 2- spectrophotometrically in the range of COD values of 100 mg / L to 900 mg / L measurements were made at a wavelength of 600 nm. and COD values less than or equal to 90 mg / L measurements were made at a wavelength of 420 nm. The results showed that the method SNI 06-6898.2- 2009  has good validation results including the r results obtained from the calibration curve equation of 0.998, a precision of 1.82%, an accuracy of 98.25% and LOD and LOQ of 12.27 mg / L and 25, 61 mg / L.
DEVELOPMENT OF COD (CHEMICAL OXYGEN DEMAND) ANALYSIS METHOD IN WASTE WATER USING SPECTRODIRECT Ade Heri Mulyati; Leny Heliawati; Sutanto .; Uswatun Hasanah; Diana Widiastuti; Siti Warnasih; Yulian Syahputri
Journal of Science Innovare Vol 3, No 2 (2020): Journal of Science Innovare
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33751/jsi.v3i2.3006

Abstract

Increased human activities will cause various problems, one of which is water pollution in water sources because it receives a pollution load that exceeds its carrying capacity. In the context of environmental conservation, the government has set quality standards for liquid waste produced by various industries and other activities in a Decree of the State Minister for the Environment. COD (Chemical Oxygen Demand) is one of the most important parameters in wastewater quality standards. This study aims to validate the COD analysis method which refers to COD Thermoreactor System (LOVIBOND brand) at Pakuan University Service Laboratory, to ensure the validity of COD analysis results at Pakuan University Service Laboratory. Spectrodirect COD analysis method provides results that meet the requirements of accuracy, precision, LOD, and LOQ which is quite good. The results of the Coefficient of Variation give good results with a value of 1.8841% indicating the accuracy of the analysis method is good. The accuracy parameter also gives good results and meets the requirements with a% recovery value of 98.70351%. Overall, it can be stated that the spectrodirect analysis method tested is an accurate, precise, simple, and economical method for determining COD levels
Utilization Of White-Meat, Red-Meat And Super Red Dragon Fruit (Hylocereus sp) Skin Waste As An Alternative Food Source Yulian Syahputri; Diana Widiastuti
Journal of Science Innovare Vol 1, No 01 (2018): Journal of Science Innovare
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (283.658 KB) | DOI: 10.33751/jsi.v1i01.679

Abstract

Dragon fruit skin, waste material (dragon fruit waste), will have a profitable sale value if it can be used as a food raw material. Dragon fruit skin waste contains relatively high dietary fiber so it can be used as a food raw material. This study aims to utilize dragon fruit skin waste for the manufacture of dragon fruit skin flour as an alternative food source. Some tests are made on white-meat dragon fruit skin, red-meat dragon fruit skin and super red dragon fruit skin. The preliminary study is the soaking of the three types of dragon fruit skin in two solutions, namely 0.1% sodium citrate and 0.1% sodium metabisulfite to prevent the browning effect on flour. Dragon fruit skin flour from the soaking with both solutions is then characterized physically, including its texture, color, flavor and rendement. The best physical characterization is followed by chemical characterization, including the contents of water, ash, protein, fat, carbohydrate, dietary fiber, minerals (Fe, Na, K, Ca and P), and also microbiological characterization of Escherichia coli, molds and Bacillus cereus. The chemical and microbiological characterization shows that the red-meat dragon fruit skin flour has better results than the white-meat and super red dragon fruit skin flour does. The red-meat dragon fruit skin flour contains 8.80% water, 0.20% ash, 2.35% fat, 7.69%, protein, 68,29% carbohydrate and 28,72% dietary fiber as well as 4.40 mg K, 8.76 mg Na , 0.65 mg Fe , 10.20 mg Ca and 32.58 mg P. Keywords: Waste, Dragon Fruit Skin, Dragon Fruit Skin Powder, Alternative Food Source
STUDIES ON PREPARATION OF Fe(III)/TiO2 BY SOL-GEL METHOD Linda J Kusumawardani; Yulian Syahputri
Journal of Science Innovare Vol 2, No 01 (2019): Journal of Science Innovare, February 2019
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (327.641 KB) | DOI: 10.33751/jsi.v2i01.1523

Abstract

In this study, Fe/TiO2 powder was synthesized by sol-gel method using mixture of Titanium Tetraisopropoxide (TTIP) as precursor and FeCl3 as iron source of 10% (w/w). The Fe/TiO2 powder was calcined at 500 °C for 1 hour. The sample of Fe/TiO2 was characterized using FTIR anad DRS measurements. FTIR analysis showed that Fe was successfully doped on TiO2 and then DRS analysis proved that the visible light was absorbed by Fe/TiO2 with its band gap energy up to 2.3 eV
DEVELOPMENT OF COD (CHEMICAL OXYGEN DEMAND) ANALYSIS METHOD IN WASTE WATER USING SPECTRODIRECT Ade Heri Mulyati; Leny Heliawati; Sutanto .; Uswatun Hasanah; Diana Widiastuti; Siti Warnasih; Yulian Syahputri
Journal of Science Innovare Vol 3, No 2 (2020): Journal of Science Innovare, Volume 03 Number 02 2020
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33751/jsi.v3i2.3006

Abstract

Increased human activities will cause various problems, one of which is water pollution in water sources because it receives a pollution load that exceeds its carrying capacity. In the context of environmental conservation, the government has set quality standards for liquid waste produced by various industries and other activities in a Decree of the State Minister for the Environment. COD (Chemical Oxygen Demand) is one of the most important parameters in wastewater quality standards. This study aims to validate the COD analysis method which refers to COD Thermoreactor System (LOVIBOND brand) at Pakuan University Service Laboratory, to ensure the validity of COD analysis results at Pakuan University Service Laboratory. Spectrodirect COD analysis method provides results that meet the requirements of accuracy, precision, LOD, and LOQ which is quite good. The results of the Coefficient of Variation give good results with a value of 1.8841% indicating the accuracy of the analysis method is good. The accuracy parameter also gives good results and meets the requirements with a% recovery value of 98.70351%. Overall, it can be stated that the spectrodirect analysis method tested is an accurate, precise, simple, and economical method for determining COD levels
Utilization Of White-Meat, Red-Meat And Super Red Dragon Fruit (Hylocereus sp) Skin Waste As An Alternative Food Source Yulian Syahputri; Diana Widiastuti
Journal of Science Innovare Vol 1, No 1 (2018): Journal of Science Innovare, Volume 01 Number 01 2018
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33751/jsi.v1i01.679

Abstract

Dragon fruit skin, waste material (dragon fruit waste), will have a profitable sale value if it can be used as a food raw material. Dragon fruit skin waste contains relatively high dietary fiber so it can be used as a food raw material. This study aims to utilize dragon fruit skin waste for the manufacture of dragon fruit skin flour as an alternative food source. Some tests are made on white-meat dragon fruit skin, red-meat dragon fruit skin and super red dragon fruit skin. The preliminary study is the soaking of the three types of dragon fruit skin in two solutions, namely 0.1% sodium citrate and 0.1% sodium metabisulfite to prevent the browning effect on flour. Dragon fruit skin flour from the soaking with both solutions is then characterized physically, including its texture, color, flavor and rendement. The best physical characterization is followed by chemical characterization, including the contents of  water,  ash, protein, fat, carbohydrate, dietary fiber, minerals (Fe, Na, K, Ca and P), and also microbiological characterization of Escherichia coli, molds and Bacillus cereus. The chemical and microbiological characterization shows that the red-meat dragon fruit skin flour has better results than the white-meat and super red dragon fruit skin flour does. The red-meat dragon fruit skin flour contains 8.80% water, 0.20% ash, 2.35% fat, 7.69%, protein, 68,29% carbohydrate and 28,72% dietary fiber as well as 4.40 mg K, 8.76 mg Na , 0.65 mg Fe , 10.20 mg Ca and 32.58 mg P. Keywords: Waste, Dragon Fruit Skin, Dragon Fruit Skin Powder, Alternative Food Source
STUDIES ON PREPARATION OF Fe(III)/TiO2 BY SOL-GEL METHOD Linda J Kusumawardani; Yulian Syahputri
Journal of Science Innovare Vol 2, No 1 (2019): Journal of Science Innovare, Volume 02 Number 01 2019
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33751/jsi.v2i01.1523

Abstract

In this study, Fe/TiO2 powder was synthesized by sol-gel method using mixture of Titanium Tetraisopropoxide (TTIP) as precursor and FeCl3 as iron source of 10% (w/w). The Fe/TiO2 powder was calcined at 500 °C for 1 hour. The sample of Fe/TiO2 was characterized using FTIR anad DRS measurements. FTIR analysis showed that Fe was successfully doped on TiO2 and then DRS analysis proved that the visible light was absorbed by Fe/TiO2 with its band gap energy up to 2.3 eV
DEVELOPMENT OF COD (CHEMICAL OXYGEN DEMAND) ANALYSIS METHOD IN WASTE WATER USING UV-VIS SPECTROPHOTOMETER Uswatun Hasanah; Ade Heri Mulyati; Sutanto .; Diana Widiastuti; Siti Warnasih; Yulian Syahputri; Tri Panji
Journal of Science Innovare Vol 3, No 2 (2020): Journal of Science Innovare, Volume 03 Number 02 2020
Publisher : Universitas Pakuan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33751/jsi.v3i2.3007

Abstract

The COD (Chemical Oxygen Demand) analysis method based on the Indonesian National Standard (SNI) is a revision of SNI 06-6989.2-2004, Water and wastewater - Part 2: Method of testing for chemical oxygen demand (COD) with closed reflux spectrophotometrically. This SNI uses references from international standard methods, namely Standard Methods for the Examination of Water and Wastewater, 21st Edition, editor of LS Clesceri, AE Greenberg, AD Eaton, APHA, AWWA and WEF, Washington DC, 2005, Methods 5220 D (Closed Reflux, Colorimetric Methods). The purpose of this study was to validate the total method for testing chemical oxygen demand (COD) in water and wastewater with the reduction of Cr2O7 2- spectrophotometrically in the range of COD values of 100 mg / L to 900 mg / L measurements were made at a wavelength of 600 nm. and COD values less than or equal to 90 mg / L measurements were made at a wavelength of 420 nm. The results showed that the method SNI 06-6898.2- 2009  has good validation results including the r results obtained from the calibration curve equation of 0.998, a precision of 1.82%, an accuracy of 98.25% and LOD and LOQ of 12.27 mg / L and 25, 61 mg / L.