cover
Contact Name
Benny Hidayat, PhD
Contact Email
bennyhidayat@ft.unand.ac.id
Phone
-
Journal Mail Official
bennyhidayat@ft.unand.ac.id
Editorial Address
-
Location
Kota padang,
Sumatera barat
INDONESIA
Jurnal Rekayasa Sipil
Published by Universitas Andalas
ISSN : 18582133     EISSN : 24773484     DOI : -
Core Subject : Engineering,
Jurnal Rekayasa Sipil' translated as Civil Engineering Journal, is a scholarly periodical that published by Civil Engineering Departement, Faculty of Engineering, Andalas University (Unand), Padang, West Sumatra, Indonesia. The journal, abbreviated as JRS-Unand, covers recent topics in civil engineering as stated in its focus and scope. JRS-Unand publishes 6-10 articles in each edition with 8-14 pages long for each article. One volume of JRS-Unand divided into two editions, which published in February and October each year. Articles are written in Bahasa Indonesia (Indonesian language) or can be in English.
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 5, No 1 (2009)" : 6 Documents clear
PENGARUH EKSENTRISITAS PUSAT MASSA BANGUNAN BETON BERTULANG TERHADAP STABILITAS STRUKTUR YANG MENGALAMI BEBAN GEMPA Jati Sunaryati; Ruddy Kurniawan; Eko Sukma Putra
Jurnal Rekayasa Sipil (JRS-Unand) Vol 5, No 1 (2009)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (433.815 KB) | DOI: 10.25077/jrs.5.1.1-10.2009

Abstract

Untuk mengurangi resiko gempa bumi, perilaku struktur harus diketahui terlebih dahulu. Analisa ini dimaksudkan untuk mengetahui perilaku struktur terhadap gempa bumi bila pada stuktur tersebut mempunya eksentrisitas e terhadap pusat massa dan pusat rotasi. Eksentrisitas ini terjadi karena pusat rotasi dan pusat massa pada gedung tidak berimpit. Dengan adanya hal ini mengakibatkan gedung akan mengalami momen torsi yang mengakibatkan gedung mengalami puntir. Analisa yang digunakan adalah dengan Analisa 3 Dimensi, dimana analisa dengan memperhitungkan beban statis dan dinamis. Analisis ini dimaksudkan untuk melihat pengaruh eksentrisitas bangunan terhadap gaya-gaya yang bekerja pada bangunan. Periode natural struktur, gaya dalam struktur dan lendutan dipengaruhi oleh besarnya eksentrisitas, dimana bangunan model 1 (e = 22.458), model 2 (e = 18.057), model 3 (e = 13.943) dan model 4 (e = 10.079) semakin kecil eksentrisitas, maka semakin kecil periode natural struktur dengan selisih maksimum sebesar ± 18% dan semakin kecil gaya dalam struktur dengan selisih maksimum sebesar ± 21% dan semakin kecil lendutan dengan selisih maksimum sebesar ± 15%. Keywords : gempa bumi, perilaku struktur, eksentrisitas.
JENIS DAN RAGAM KERUSAKAN SALURAN PRIMER DAERAH IRIGASI BANDAR LAWEH KABUPATEN SOLOK Februarman Februarman
Jurnal Rekayasa Sipil (JRS-Unand) Vol 5, No 1 (2009)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (288.453 KB) | DOI: 10.25077/jrs.5.1.57-66.2009

Abstract

Untuk mengalirkan air dari sumbernya (intake) ke areal persawahan diperlukan saluran irigasi. Saluran irigasi akan melewati medan dengan berbagai kondisi topografi. Untuk dapat mengairi areal seluas mungkin, maka saluran primer dipilih sebagai saluran yang mengikuti garis kontur yang disebut juga saluran garis tinggi. Saluran primer pada Daerah Irigasi Bandar Laweh Kabupaten Solok melintasi medan dengan topografi yang curam, menyebabkan banyaknya kerusakan sepanjang saluran, mulai dari kebocoran saluran, kerusakan tanggul, sampai kelongsoran badan saluran, sehingga suplai air untuk areal persawahan tidak terpenuhi sesuai kebutuhan. Usaha rehabilitasi yang dilakukan selama ini hanya bersifat parsial, sehingga masalah utama yaitu kekurangan suplai air tidak dapat ditanggulangi. Diperlukan penataan dan perencanaan ulangsistem jaringan irigasi Bandar Laweh, agar daerah sasaran irigasi dapat terairi dengan baik.Kata Kunci : irigasi, saluran garis tinggi, kebocoran, kelongsoran.
ANALISA POTENSI LIKUIFAKSI BERDASARKAN DATA PENGUJIAN SONDIR (STUDI KASUS GOR HAJI AGUS SALIM DAN LAPAI, PADANG) Hendri Gusti Putra; Abdul Hakam; Dody Lastaruna
Jurnal Rekayasa Sipil (JRS-Unand) Vol 5, No 1 (2009)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (779.097 KB) | DOI: 10.25077/jrs.5.1.11-22.2009

Abstract

Likuifaksi (liquefaction) merupakan salah satu bahaya yang ditimbulkan dari gempa bumi. Pada saat gempa terjadi, tanah mengalami perubahan sifat dari solid ke liquid akibat beban siklik yang diterima. Untuk itu, diperlukan suatu metode yang mudah dan sederhana untuk mengevaluasi potensi perilaku likuifaksi pada tanah, yang dapat diterapkan di kota Padang dan Sumatera Barat secara umumnya. Salah satunya adalah metode analisa potensi likuifaksi menggunakan data pengujian sondir di lapangan. Metode yang dititik beratkan kepada korelasi data perlawanan konus terhadap cyclic stress ratio dalam suatu grafik sederhana (Seed dan Idriss) yang menunjukkan batasan tanah mengalami likuifaksi atau tidak. Grafik dapat menunjukkan variasi nilai kritis uji sondir terhadap potensi likuifaksi telah dikembangkan untuk beberapa variasi terahadap magnitude gempa dan percepatan maksimum tanah serta pengaruh level muka air tanah. Dari hasil penelitian yang dilakukan, menunjukkan daerah penelitian yaitu GOR Haji Agus Salim dan Lapai, Padang, memiliki nilai faktor keamanan yang sangat kecil (< 0,5), dibandingkan dengan faktor keamanan yang telah ditetapkan, yaitu 1,50. Hal ini berati bahwa daerah penelitian memiliki potensi besar terhadap likuifaksi. Keywords : gempa bumi, likuifaksi, normalisasi perlawanan kerucut, in-situ test
ANALISA PENGARUH PENAMBAHAN TULANGAN TEKAN TERHADAP DAKTILITAS KURVATUR BALOK BETON BERTULANG Oscar Fitrah Nur
Jurnal Rekayasa Sipil (JRS-Unand) Vol 5, No 1 (2009)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (354.779 KB) | DOI: 10.25077/jrs.5.1.23-34.2009

Abstract

Salah satu usaha untuk meningkatkan kekuatan, kekakuan dan daktilitas beton bertulang dapat dilakukan dengan penambahan tulangan tekan (compression steel). Penambahan tulangan tekan pada balok beton bertulang hanya sedikit memberikan konstribusi terhadap kekuatan dan kekakuan balok, akan tetapi mempunyai pengaruh besar terhadap peningkatan daktilitas balok beton bertulang. Penyelidikan tentang model konstitutif beton (hubungan tegangan-regangan beton) tak tertekang yang dilakukan oleh Hognestad, memberikan sumbangan yang berarti dalam menganalisis perilaku daktilitas kurvatur balok beton bertulang. Berdasarkan model konstitutif beton yang diberikan oleh Hognestad tersebut, dilakukan analisis pengaruh penambahan tulangan tekan terhadap daktilitas kurvatur balok beton bertulang. Studi kasus pada penelitian ini menggunakan model benda uji dengan rasio tulangan tarik dan tulangan tekan yang bervariasi. Hasil dari analisis yang dilakukan, memperlihatkan bahwa penambahan tulangan tekan pada balok beton bertulang akan meningkatkan daktilitas kurvatur balok beton bertulang tersebut. Keywords : balok beton bertulang, penambahan tulangan tekan, model konstitutif beton, daktilitas kurvatur balok
SEMPROTAN AIR PADA PIPA TEGAK MEMPENGARUHI DEBIT PEMBILASAN PADA MODEL ″SEA-OUTFALL″ Sunaryo Sunaryo
Jurnal Rekayasa Sipil (JRS-Unand) Vol 5, No 1 (2009)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3036.925 KB) | DOI: 10.25077/jrs.5.1.35-44.2009

Abstract

Untuk meningkatkan pengoperasian suatu ′sea-outfall′ perlu dihilangkan semua hambatan yang terjadi, seperti adanya air laut, tumbuhan laut, dan lumpur yang masuk kedalamnya yang dapat mengakibatkan terjadinya pengurangan debit air buangan yang akan dialirkan ke laut. Selain itulama-kelamaan akan mengakibatkan kerusakan pada ′sea-outfall′ itu sendiri. Untuk menghilangkan hambatan tersebut dan debit air buangan yang tetap, diperlukan suatu sistem. Dalam penelitian ini dilakukan pembuatan model ′sea-outfall′ dengan meletakkan suatu penyemprotan air di bawah pipa tegak dimana air buangan akan dikeluarkan. Dari percobaan ini diperoleh debit pembilasan sebesar 36,34 liter/menit (48%) dibandingkan tanpa semprotan air untuk beda jenis yang sama.Kata Kunci : semprotan air, pipa tegak, debit air pembuangan, ′sea-outfall′.
STUDI PENGARUH GEMPA TERHADAP VARIASI PANJANG TULANGAN PENYALURAN PADA SAMBUNGAN BALOK DAN KOLOM TEPI Febrin Anas Ismail
Jurnal Rekayasa Sipil (JRS-Unand) Vol 5, No 1 (2009)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1485.884 KB) | DOI: 10.25077/jrs.5.1.45-56.2009

Abstract

Pada struktur bangunan yang dimiliki masyarakat kita, sering dijumpai struktur tersebut kurang memenuhi persyaratan dalam hal teknis. Sehingga saat terjadi Gempa pada tanggal 6 Maret 2007 menimbulkan kerusakan pada konstruksi bangunan baik perumahan rakyat, fasilitas umum maupun bangunan pemerintah. Kerusakan yang terbanyak didominasi oleh perumahan rakyat yang tergolong non-engineered building, dimana perencanaannya dilakukan berdasarkan pengalaman turun temurun. Salah satu bentuk kerusakan pada komponen struktural bangunan yang terjadi akibat gempa terjadi pada bagian sambungan antara balok dan kolom. Hal ini diakibatkan karena tidak memadainya panjang tulangan penyaluran Oleh karena itu perlu dikaji seberapa besar pengaruh panjang penyaluran tulangan terhadap beban gempa pada bangunan rumah sederhana. Penelitian ini menggunakan portal berbentuk ″L″ dengan variasi panjang penyaluran tulangan pada sambungan balok dan kolom tepi sebesar 40 cm dan 20 cm. Untuk mengetahui mutu bahan yang digunakan, terlebih dahulu dilakukan tes material untuk agregat halus dan kasar.Pengujian sampel dilakukan dengan memberi beban horizontal dengan metode static pushover sebagai bentuk dari beban gempa. Dari hasil pengujian portal didapatkan besarnya pengaruh variasi penyaluran tulangan pada sambungan balok dan kolom tepi, sehingga didapatkan panjang penyaluran tulangan yang baik untuk digunakan.Kata Kunci : gempa, panjang penyaluran.

Page 1 of 1 | Total Record : 6