cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota yogyakarta,
Daerah istimewa yogyakarta
INDONESIA
International Journal of Power Electronics and Drive Systems (IJPEDS)
ISSN : -     EISSN : 20888694     DOI : -
Core Subject : Engineering,
International Journal of Power Electronics and Drive Systems (IJPEDS, ISSN: 2088-8694, a SCOPUS indexed Journal) is the official publication of the Institute of Advanced Engineering and Science (IAES). The scope of the journal includes all issues in the field of Power Electronics and drive systems. Included are techniques for advanced power semiconductor devices, control in power electronics, low and high power converters (inverters, converters, controlled and uncontrolled rectifiers), Control algorithms and techniques applied to power electronics, electromagnetic and thermal performance of electronic power converters and inverters, power quality and utility applications, renewable energy, electric machines, modelling, simulation, analysis, design and implementations of the application of power circuit components (power semiconductors, inductors, high frequency transformers, capacitors), EMI/EMC considerations, power devices and components, sensors, integration and packaging, induction motor drives, synchronous motor drives, permanent magnet motor drives, switched reluctance motor and synchronous reluctance motor drives, ASDs (adjustable speed drives), multi-phase machines and converters, applications in motor drives, electric vehicles, wind energy systems, solar, battery chargers, UPS and hybrid systems and other applications.
Arjuna Subject : -
Articles 2,660 Documents
Analysis of the feasibility of adding a grid-connected hybrid photovoltaic system to reduce electrical load Moranain Mungkin; Habib Satria; Dina Maizana; Muzamir Isa; Syafii Syafii; Muhammad Yonggi Puriza
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp1160-1171

Abstract

The power generation system with hybrid system grid connected (HSGC) technology is an energy-saving technology that is able to compensate for electricity loads in an energy-efficient manner in today's technological advances. Electrical transient analyzer power (ETAP) simulation software is implemented so that the modeling will have an impact on the development of hybrid systems. Testing the reliability of the system is simulated at the load of school buildings, laboratories, mosques, and kindergarten schools. parameters obtained by evaluating the ratio of the voltage drop before and after the addition of photovoltaic. The value of the voltage drops decreases with the integration of hybrid photovoltaic. The school building panels experienced a voltage drop of 0.15%, reduced after the addition of photovoltaics and wind turbines. Then on the Laboratory panel, a voltage drops of 0.05% was obtained, on the mosque panel the voltage drop reached 0.11%, and on the kindergarten building panel the voltage drop reached 0.09% after the addition of photovoltaic hybrid. From this comparison it can be said that PV and wind turbines can affect the voltage drop and reduce the consumption of electricity loads from the grid caused by adding power from the hybrid photovoltaic hybrid to each load.
Establishment of new automated multi range thermal current converter Nahed Abdelmonaem; Rasha Sayed Mohammed Ali; Hamdy Shatla
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp842-851

Abstract

A new automated multirange thermal current converter (TCC) has been designed and implemented at the National Institute of Standards (NIS), Egypt. Five single junction thermal current converters (SJTCCs) have been connected in parallel on PCB with an LCD, keypad and a microcontroller to control a five fast switching relays. This TCC has been designed to cover the ac current ranges from 500 mA to 5 A at frequencies from 40 Hz up to 100 kHz. The construction of the new automated TCC has been presented to solve some problems of using shunt resistance at high currents. Furthermore, a new automatic calibration system has been established to calibrate the established TCC against another standard TCC. This software program has been specially designed using MATLAB program to overcome the problems of manual calibration and measurement. The expanded uncertainties are estimated for all ranges at different frequencies and also, the ac-dc differences. The performance of the new automated TCC is also evaluated by comparing its accuracy by measuring ac currents at different frequencies with the performance of a traditional TCC.
Fuzzy logic control based maximum power point tracking technique in standalone photovoltaic system Muhammad Hasbi Azmi; Siti Zaliha Mohammad Noor; Suleiman Musa
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp1110-1120

Abstract

This study describes the development of a smart technique for tracking the highest power point on a standalone photovoltaic (SAPV) system when temperature and irradiance conditions are changing using fuzzy logic control (FLC). The PV systems comprises of a PV array, a boost converter, a controller for tracking the maximum power point, and an inverter to power the AC loads. The FLC-based maximum power point tracking (MPPT) is proposed because the technique is not complex and does not need a deep comprehension of the particular model of the system. Furthermore, the technique is efficient and fast response in tracking maximum power (MP) from the PV array. The technique overcame the limitation of the conventional MPPT technique that resulted in slow tracking of the MP and was not accurate on the optimal position of the PV array output power. The SAPV system is integrated with the sealed lead acid (SLA) battery bank as an alternative power source and makes up for power shortages by supplying energy to the load without interruption during power shortages. A system for managing the battery has been included in the system to preserve the battery's longevity by controlling the battery's charging process. The PV system is able to supply single-phase output AC voltage of 230 Vrms and has low total harmonic distortion (THD) that is suitable for home appliances. The achieved simulation results demonstrate the effectiveness of the suggested fuzzy logic controller in tracking the MPP.
An intelligent overcurrent relay to protect transmission lines based on artificial neural network Noha Abed-Al-Bary Al-Jawady; Mohammed Ahmed Ibrahim; Laith A. Khalaf; Mahmood Natiq Abed
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp1290-1299

Abstract

Power systems are susceptible to faults due to system failures or natural calamities. This could be caused by damage to power system components, resulting in an interruption of power delivery to clients. Overcurrent relays are important relays that protect distribution feeders, transmission lines, transformers, and other components. The intelligent relay can perform both primary and secondary functions. Line-to-ground (L-G) faults are the most common occurrence in long transmission lines, posing a serious threat to electrical equipment. This article presents improved fault classification for transmission line overcurrent protection and highlights the use of artificial neural network (ANN) techniques to protect transmission lines of 100 km (terco type). An ANN is used to classify the faults. A back propagation neural network (BPNN) is used in this case. The neural network has been trained to classify faults in transmission lines for overcurrent protection. Various fault conditions are considered. In the event of a fault condition, the output of a neural network will be a tripping signal. The MATLAB neural network tool and the Simulink package are used to model the suggested method.
Dynamic analysis of grid-connected hybrid wind farm Jannatul Mawa Akanto; Md Kamrul Islam; Effat Jahan; Md. Rifat Hazari; Mohammad Abdul Mannan; Md. Abdur Rahman
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp1230-1237

Abstract

Since the last couple of years, the expansion of grid-connected wind farms (WFs) has increased dramatically. The wind turbine might be a fixed-speed squirrel cage induction generator (FSWT-SCIG) or a variable speed wind turbine with a doubly-fed induction generator (VSWT-DFIG). The main disadvantage of FSWT-SCIG is its lack of ability to adjust power quality. Inversely, the VSWT-DFIG is a competitive wind turbine technology that allows for the effective management of both active and reactive power outputs. Moreover, it has some extraordinary functionaries rather than FSWTSCIG. However, the major downside to this system is that it only has a partial rating AC/DC/AC power converter, which is extremely expensive. Hence, to reduce the overall cost combining the implementation of VSWT-DFIG and FSWT-SCIG in a WF could be a feasible alternative. Therefore, a novel DFIG control technique is proposed in this article, which can keep the connection point voltage of the hybrid WF stable during dynamic analysis. To evaluate the proposed controller responses PSCAD/EMTDC software has been used.
Design of suspension control system for bearingless induction motor using fuzzy-I controller Qasim Kadhim Jasim; Mohammed Moanes E. Ali
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp771-780

Abstract

In the bearingless induction motor (BIM), the rotor of BIM is supported by the magnetic force, the radial position control technique is studied in this paper, an approximation and simplification are used to create a linearized model of suspension system. The objective of this paper is to design a control system that overcomes the limitations of the traditional controller and to improve the control performance and achieve high stability, even if it is exposed to external disturbance and internal disturbance (changes in load or speed). In order to solve this problem, the proposed controller is based on the fuzzy-I controller that combines the positive features of both fuzzy logic and the integration. In comparison with the conventional PID, the results show that the fuzzy-I controller reduces the peak-to-peak rotor deviation by 23% under effect of external disturbance force and 31% under effect of speed variation and 9% under effect of load variation.
Optimization of fractional order PI controller to regulate grid voltage connected photovoltaic system based on slap swarm algorithm Ibrahim Altawil; Mohammad Awad Momani; Mahamood A. Al-Tahat; Raed Al Athamneh; Mohammed Adnan Al-Saadi; Zaid Albataineh
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp1184-1200

Abstract

Problems with voltage and stability have arisen as a result of the dramatic development in renewable energy generating units, notably solar energy systems linked to low and medium voltage networks, and the influence of active loads that vary rapidly from time to time during the day. Because reactive power is directly proportional to voltage, its use to renewable energy producing units can only improve their efficiency. Better performance for these controllers is possible via the usage of several controller types. In this paper, we use a salp swarm optimization algorithm (SSA) to design fractional order proportional-integral (FO-PI) controllers, whose job it is to regulate the active and reactive power of solar inverters by compensating for the overvoltage and undervoltage presented by the inverters' ability to absorb and produce reactive power. After that, we compared the FO-PI controller's results to those of the standard PI controller. Grid-connected photovoltaic (PV) system modeling and simulation were performed using the MATLAB/ Simulink modeling and simulation tools. After that, the full PV system was simulated in the most likely situations across a range of grid and weather conditions. We may infer from the simulation results that this model is credible, reliable, and applicable to the analysis of grid-connected PV systems.
Discontinuous conduction mode approach of ultra-lift DC-DC converter based on three windings coupled inductor Saeed Hasanzadeh; Milad Asadi; Tole Sutikno
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp921-933

Abstract

These days, DC-DC boost converters play an essential role in a variety of applications. Therefore, a variety of techniques were proposed in the literature to achieve the highest voltage gain. A large number of passive elements are typically used in high-voltage DC-DC converters. Increasing the order of the system would make modeling and controlling the output voltage of the converter more complex. This paper examines an ultra-lift DC–DC converter using a three-winding inductor and a super-lift construction in discontinuous conduction mode (DCM). This converter provides substantial voltage gain by utilizing the three-winding coupling inductor topology without increasing the duty cycle or passive circuit parts. Because the DCM operation mode occurs in the converter, it is necessary to investigate and analyze it. The DCM operation mode of an Ultra-Lift converter is examined in this study, and then simulation results are shown to validate the equations.
Design of a multi-level inverter for solar power systems with a variable number of levels technique Mohammed A. Qasim; Vladimir Ivanovich Velkin; Mustafa Fawzi Mohammed; Alaa Ahmad Sammour; Yang Du; Sajjad Abdul-Adheem Salih; Baseem Abdulkareem Aljashaami; Sharipov Parviz Gulmurodovich
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp1218-1229

Abstract

Overall harmonic distortion and losses will grow during an energy conversion process, while power stability will be reduced. Multilevel inverter technologies have recently become very popular as low-cost alternatives for a variety of industrial purposes. The design's minimal benefits include reduced component losses, decreased switching and conduction losses, along with enhanced output voltage and current waveforms. Also, a reduction of the harmonic components of the current and output voltage of the inverter are the most important requirements in multilevel inverters. A seven-level inverter design is presented in this paper that is simulated using MATLAB/Simulink. The inverter converts the DC voltage from three photovoltaic (PV) systems into AC voltage at seven levels. During an outage of one of the PV systems, the inverter will make a switching reduction and supply the AC voltage as a five-level inverter. The inverter’s total harmonic distortion (THD) when it performs as a five-level or seven-level inverter is 4.19% or 1.13% respectively. The modulation technique used is phase disposition via four carriers and a single reference signal at the fundamental frequency.
Reduced switched seven level multilevel inverter by modified carrier for high voltage industrial applications Sanka Sreelakshmi; Machineni Sanjeevappa Sujatha; Jammy Ramesh Rahul; Tole Sutikno
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 14, No 2: June 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v14.i2.pp872-881

Abstract

Multilevel inverters are widely used in high-power and high-voltage applications due to their lower total harmonic distortion (THD), decreased switching stress on their switches, and other benefits. However, increasing the number of steps results in a drop in THD, which results in a larger size. As a result, a new 7-level reduced switched cascaded multilevel inverter (CMLI) has been designed for the current project. This architecture employs seven switches and seven levels of MLI to achieve the same output as a conservative multilevel inverter (MLI). To generate gate pulses for the switches, conventional and modified carriers were employed, and a third harmonic component was added into the sine wave to increase the fundamental output voltage. Finally, MATLAB or simulation is utilized to test the results of this task's design. According to the analysis, the proposed design may reduce harmonic distortion and improve the fundamental voltage component with fewer switches.

Filter by Year

2011 2026


Filter By Issues
All Issue Vol 17, No 1: March 2026 Vol 16, No 4: December 2025 Vol 16, No 3: September 2025 Vol 16, No 2: June 2025 Vol 16, No 1: March 2025 Vol 15, No 4: December 2024 Vol 15, No 3: September 2024 Vol 15, No 2: June 2024 Vol 15, No 1: March 2024 Vol 14, No 4: December 2023 Vol 14, No 3: September 2023 Vol 14, No 2: June 2023 Vol 14, No 1: March 2023 Vol 13, No 4: December 2022 Vol 13, No 3: September 2022 Vol 13, No 2: June 2022 Vol 13, No 1: March 2022 Vol 12, No 4: December 2021 Vol 12, No 3: September 2021 Vol 12, No 2: June 2021 Vol 12, No 1: March 2021 Vol 11, No 4: December 2020 Vol 11, No 3: September 2020 Vol 11, No 2: June 2020 Vol 11, No 1: March 2020 Vol 10, No 4: December 2019 Vol 10, No 3: September 2019 Vol 10, No 2: June 2019 Vol 10, No 1: March 2019 Vol 9, No 4: December 2018 Vol 9, No 3: September 2018 Vol 9, No 2: June 2018 Vol 9, No 1: March 2018 Vol 8, No 4: December 2017 Vol 8, No 3: September 2017 Vol 8, No 2: June 2017 Vol 8, No 1: March 2017 Vol 7, No 4: December 2016 Vol 7, No 3: September 2016 Vol 7, No 2: June 2016 Vol 7, No 1: March 2016 Vol 6, No 4: December 2015 Vol 6, No 3: September 2015 Vol 6, No 2: June 2015 Vol 6, No 1: March 2015 Vol 5, No 4: 2015 Vol 5, No 3: 2015 Vol 5, No 2: 2014 Vol 5, No 1: 2014 Vol 4, No 4: December 2014 Vol 4, No 3: September 2014 Vol 4, No 2: June 2014 Vol 4, No 1: March 2014 Vol 3, No 4: December 2013 Vol 3, No 3: September 2013 Vol 3, No 2: June 2013 Vol 3, No 1: March 2013 Vol 2, No 4: December 2012 Vol 2, No 3: September 2012 Vol 2, No 2: June 2012 Vol 2, No 1: March 2012 Vol 1, No 2: December 2011 Vol 1, No 1: September 2011 More Issue