cover
Contact Name
Adi Kusmayadi
Contact Email
adikusmayadi@polindra.ac.id
Phone
-
Journal Mail Official
jtt@polindra.ac.id
Editorial Address
-
Location
Kab. indramayu,
Jawa barat
INDONESIA
Jurnal Teknologi Terapan
ISSN : 24773506     EISSN : 25491938     DOI : -
JTT memuat naskah hasil-hasil penelitian di bidang teknologi terapan.
Articles 292 Documents
EFEK MEDAN ELEKTROMAGNET PADA MESIN BENSIN TERHADAP EMISI GAS BUANG DAN ENERGI PEMBAKARAN Tatun H Nufus; Andi Ulfiana; Isnanda Nuriskasari; Sri Lestari
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.308

Abstract

The purpose of this study was to analyze the effects of electromagnetic fields on combustion quality, especially on gasoline engines. One of the indicators of good combustion quality was environmentally friendly exhaust emissions and relatively large combustion energy. This research uses an experimental method, with the independent variables magnetic field strength and fuel. The field strength used in this study consisted of 4 variations, namely 647 Gauss, 847 Gauss, 1068 Gauss and 1419 gauss, while the fuel used was E0 (premium 100% bioethanol 0%), E10 (premium 90% bioethanol 10%), E20 (premium 80% bioethanol 20%), and E30. (premium 70% bioethanol 30%). The parameters of the electromagnetic field strength and various types of fuel composition were used to test exhaust gas emissions and combustion energy (as the dependent variable) on the 125cc MIO gasoline motorbike in 2018.The result was that the levels of CO2 exhaust emissions increased by 35% and CO levels decreased by 71%, combustion energy increases in the range of 13-21%. The greater the electromagnetic field provided, the more environmentally friendly the exhaust emissions are and the greater the combustion energy.
Pendeteksi Kehadiran menggunakan ESP32 untuk Sistem Pengunci Pintu Otomatis Anton Prafanto; Edy Budiman; Putut Pamilih Widagdo; Gubtha Mahendra Putra; Reza Wardhana
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.318

Abstract

The design of the detection system in this study using ESP32 module that includes Wi-Fi: 802.11 b / g / n and Bluetooth: v4.2 BR / EDR and Bluetooth Low Energy (BLE). In general, the automatic door lock system using a fingerprint or RFID card in its implementation, but this study using BLE which is a component of iBeacon which has a function as a result of the fingerprint and RFID card. ESP32 have a duty to control the door lock in order to open and lock the door using relays and solenoid system, in addition to the BLE on ESP32 serves to detect the presence of individuals where Bluetooth Device Address (BD_ADDR) smartwatch or individual gadget is already registered on ESP32. Based on the experimental results, the system can detect a user's presence smartwatch on the Received Signal Strength Indicator (RSSI), which is determined on the program was uploaded to ESP32. This system can also be developed in the future and applied to a variety of special purposes such as absenteeism, indoor mapping, and smart home.
PERANCANGAN SISTEM TATA UDARA PADA RUANG NICU DI LANTAI 3 RUMAH SAKIT “X” Annisa Pramudhita
Jurnal Teknologi Terapan Vol 6, No 2 (2020): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v6i2.272

Abstract

In order to reduce nosocomial infections, or generally known as Hospital-acquired Infections (HAIs) in NICU room, a special design of air conditioning system is needed, as per HVAC Design Manual for Hospital and Clinics. There are several parameters that concerned in air conditioning design such as temperature, Relative Humidity (RH), room pressure, air cleanliness, ventilation and room air distribution. Cooling Load Temperature Difference (CLTD) will be the main method in this research. Meanwhile, Equal Friction Loss method will be used in air duct sizing. From calculation, obtained that cooling load capacity 8,805 kW. Meanwhile heating capacity obtained 3,660 kW. Total pressure loss value for design air duct is 44,85 Pa.. Pre-filter and medium filter was built-in at AC unit, so HEPA filter is needed to be mounted in ceiling.
PENERAPAN PROTOKOL PUBLISH / SUBSCRIBE MESSAGING SYSTEM PADA SISTEM WIRELESS BUILDING NETWORK BERBASIS NRF24L01 Sarosa Castrena Abadi; Anton Prafanto; Mindit Eriyadi; Aris Suryadi; Givy Devira Ramadi
Jurnal Teknologi Terapan Vol 6, No 2 (2020): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v6i2.275

Abstract

Wireless sensor network is a common method used in the design of shared resource interconnection infrastructure at a location point to provide optimal performance. The main factor in the design of a wireless sensor network (WSN) communication protocol in the form of coordination optimization efforts between nodes, one of the effective methods that can be made to achieve such conditions is the provision of nodes using the publish / subscribe messaging system protocol. This research discusses the implementation of publish / subscribe messaging system protocol on wireless building network system based on NRF2L01. Discussions include simulation, design, implementation, application testing and system performance both on a work-to-work and performance-by-node performance. The results showed the system was able to monitor all information and control equipment from a building through a web interface making it easier for officers to maintain and supervise a building, then to test the performance of nodes with a fixed data packet size of 32 bytes, the delay value for each node is less than 1 second, then for the minimum throughput 250 kbps data rate obtained at 5.9 Kbps and the maximum throughput obtained at 72 Kbps and for packet loss of at least 0.59% while the maximum packet loss of 13.23% and the standard deviation value of delay, throughput and packet loss are smaller than the average value, the data is not very varied (stable).
Pengaruh Perubahan Dimensi Filter-Drier Dan Pipa Kapiler Terhadap Coefficient Of Performance (COP) Mesin Pendingin Kulkas 2 Pintu Khairul Mustofa; Yohanes Primadiyono
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.316

Abstract

COP on a cooling machine is used to reveal the performance of a cooling engine. To increase the COP value in the system, it can be done by changing the dimensions of the filter-drier and capillary pipes used. Therefore, this study was conducted to determine the effect of changing the dimensions of the filter-drier and capillary pipe on the COP and the consumption of electrical power produced by the 2-door refrigerator unit. The method used was an experimental method, namely by varying the filter drier and capillary tube dimensions of the 2-door refrigerator. Variations of filter driers used were filter driers with sizes 7 cm and 9 cm. While the capillary pipes used were 0.31 inches in diameter and 0.51 inches in diameter with a length of 200 cm and 250 cm respectively. The results obtained from this study indicate that the greatest COP value is obtained when using a 7 cm filter-drier and a capillary pipe with a diameter of 0.31 inches with a length of 200 cm, which is 2.80. The COP value also continues to decline as the size of the filter-drier and capillary pipes used increases.
STUDI PERANCANGAN PISAU PADA MESIN PENCACAH PLASTIK MENGGUNAKAN FINITE ELEMENT ANALYSIS Rizqi Ilmal Yaqin; Mega Lazuardi Umar; Sigiet Haryo Pranoto; Angger Bagus Prasetiyo; Bambang Hari Priyambodo
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.320

Abstract

The amount of plastic waste each year will increase by 10% every year which is a problem for a country. Therefore, proper processing of plastic waste needs to be done. Before being processed into plastic waste processing, it is necessary to have a chopping process using a plastic chopping machine. The plastic chopping machine has an important component, namely the chopping knife. Before carrying out the knife manufacturing process, it is necessary to validate the design of the blade that is used with its loading. Model simulation using software is one way to quickly validate the model. This study aims to determine the effect of loading variations on stress, strain, deformation and safety factors of the model. The use of ANSYS R17.2 software is used to analyze the chopping machine knife model with a variation of 5kg / hour, 10kg / hour, 20kg / hour and 50kg / hour capacities. The result is that the stress, strain and deformation parameters have an increase in value with increasing loading variations. The greatest values of stress, strain and deformation are in the variation of 50kg / hour respectively 64.995 Pa; 336.76 and 56,358 x 10-11mm. The value of the safety factor for all variations of loading has a value of 15. The value of the safety factor means that the design of the plastic chopping knife is safe to use up to a loading of 50kg / hour
KAJI EKSPERIMENTAL PANAS KONDENSOR AC SPLIT DENGAN VARIASI PUTARAN FAN UNTUK PENGERINGAN PADI yudhy kurniawan; Kusnandar Kusnandar; Yusup Nur Rohmat; wardika wardika
Jurnal Teknologi Terapan Vol 6, No 2 (2020): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v6i2.265

Abstract

The use of Split of Air Conditioning (AC) which is usually used for air conditioning for human convenience. In this study a split AC was used for drying rice. Rice drying using Split AC is a type of artificial drying that has an advantage compared to natural, which is shorter drying. In Split AC the hot air generated from the condenser released into the environment is useless will be flowed through the air duct to be used for drying rice. The use of condenser heat is carried out to find out how to grow rice by using variations in the condenser fan speed regulation. In Split AC, it is done to find out the flow of drying with a variation fan rotation speed of 450 rpm and 800 rpm. From the results of the data experiment for taking around 1.5 hours in the drying process obtained moisture content is 8% and 12% for the 450 rpm and 800 rpm condenser fan rotation each. Although the temperature of the air produced by the condenser heat is 53.6 oC and 50.6oC. The other data of relative humidity of the air (Relative Humidity) is 15%.
PERHITUNGAN BEBAN PENDINGINAN PADA SISTEM REFRIGERASI AIR BLAST FREEZER Boby Wisely Ziliwu
Jurnal Teknologi Terapan Vol 6, No 2 (2020): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v6i2.291

Abstract

Refrigeration is an attempt to maintain the temperature level of a material or room at a level lower than the temperature of the surrounding environment by absorbing heat from the material or room. In short it can be said that refrigeration is the process of transferring heat from a material or another room. Basically, refrigeration technology is heat treatment. The refrigeration process is inseparable from the cooling load problem during the refrigeration machine operates. Excessive cooling load on a refrigeration unit will certainly have an effect that can accelerate the process of decomposition or deterioration in the quality of the catch. This research aims to calculate the cooling load of the blast freezer water and determine the refrigeration components of the blast freezer water unit. From the research results obtained, that the ship whose refrigeration system has a cooling power of 30 kW is able to cool fish as much as 3.5 tons (3,500 kg). With a cooling load of 1 ABF space of 28.54 kW with a fish mass of 3,500 kg. the COPactual achieved by the blast freezer water is about 2.8 smaller than the COPcarnot of 6.1.
Analisis Kontrol Aliran Fluida Bervikositas Tinggi dengan Sensor Flow YF-S201 pada Otomatisasi Dispenser Minyak Goreng Hadi Supriyanto
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.311

Abstract

The purpose of Automation system on the Hygenist Automatic Frying Oil Dispenser making is to assist the frying oil sellers or suppliers in measuring the oil accurately and minimize the frying oil contamination. The dispenser is designed using pump and flowsensor to measure the frying oil pumped out. Electric valve or faucet is used to prevent contamination of the oil as the substitute of manual faucet. This study is focused on designing and making automation system on the frying oil dispenser, measuring time and volume accuracy of dispenser. Dispensers can be moved, capable of accommodating 50 Kg of oil and have a choice of two quantities; 500ml and 250ml.  As a result, flowsensor reading shows the same average frequency of 25 Hz and 35 Hz for filling 250 mL oil and 500 mL respectively. Time consumption for pumping 250 mL and 500 mL oil out from the dispenser is 8.85 s and 15,3 s respectively. Using delay program, the oil pumped out for 250 mL and 500 mL target volume need 5.75 s and 12 s delay time.
PERBANDINGAN PERFORMANSI MESIN REFRIGERASI KOMPRESI UAP CHEST FREEZER MENGGUNAKAN PIPA KAPILER dan ORIFICE ferry sugara
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.242

Abstract

Teknologi refigerasi saat ini memberikan pengaruh yang penting dalam peningkatan kualitas produk makanan. Chest dalam bahasa Inggris adalah peti, sedangkan freezer adalah pembeku. Chest freezer artinya adalah peti beku. Bentuknya adalah kotak kubus atau persegi panjang dan diletakkan di atas lantai. Akses pintu chest freezer berbentuk pintu buka atas, dan sangat efektif untuk menyimpan bahan makanan beku supaya kualitas makanan tetap baik setiap saat Tujuan dari penelitian ini adalah Mengetahui seberapa besar perbedaan performansi yang dihasilkan dari alat ekspansi berupa pipa kapiler dengan orifice dengan diameter yang berbeda dan mengetahui daya konsumsi listrik yang dipakai, sehingga mengetahui daya listrik per-hari. Metode yang dipakai dalam penelitian kali ini adalah melakukan pengujian pada sistem refrigerasi mesin pembuat es krim, dengan menguji performansinya dengan mengukur temperatur dan tekanan di setiap komponen utamanya saat sistem dalam keadaan steady. Hasil penelitian nilai COP aktual rata-rata diameter pipa kapiler 0,028 inchi adalah 2,16 sedangkan nilai COP aktual rata-rata orifice  0,031 inchi adalah 2,74. Dan nilai COP Aktual pipa kapiler diameter 0,028 inchi memiliki nilai lebih besar yaitu 2,16 sedangkan untuk orifice diameter 0,031 inchi memiliki nilai lebih kecil yaitu 1,88. Sedangkan untuk nilai efisiensi refrigrasi terbesar pada nilai rata-rata adalah pipa kapiler diameter 0,028 inchi sebesar 63,58 %. Sedangkan untuk orifice  diameter 0,031 inchi lebih kecil memiliki nilai efesiensi refrigrasi rata-rata 59,49% dan temperatur kabin pada pipa kapiler diameter 0,028 inchi nilai rata-rata dengan temperatur sebesar -9,82 0C. Sedangkan untuk orifice diameter 0,031 inchi lebih kecil memiliki nilai rata-rata lebih dingin yakni sebesar -9,09 0CKata Kunci: pipa kapiler,orifice dan COP.