cover
Contact Name
Augusta Adha
Contact Email
augusta.adha@eng.uir.ac.id
Phone
-
Journal Mail Official
saintis@journal.uir.ac.id
Editorial Address
-
Location
Kota pekanbaru,
Riau
INDONESIA
JURNAL SAINTIS
Published by Universitas Islam Riau
ISSN : 14107783     EISSN : 25807110     DOI : -
Core Subject : Social, Engineering,
Saintis is devoted to research on civil engineering related fields including geotechnics, transports, structures, water resources and others related with civil engineering topics.
Arjuna Subject : -
Articles 224 Documents
Optimasi Bentuk Struktur Elemen Cangkang Pada Pondasi Terapung Menggunakan Metode Algoritma Genetik: Shape Optimization of Structural Shell Element in Floating Foundation Using Genetic Algorithm Method Adha, Augusta; Kurniawan, Mahadi
JURNAL SAINTIS Vol. 18 No. 2 (2018)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1814.025 KB) | DOI: 10.25299/saintis.2018.vol18(2).2130

Abstract

[ID] Prinsip dasar pondasi terapung adalah keseimbangan antara berat struktur atas dan total berat tanah (termasuk didalamnya air tanah) yang dipindahkan oleh konstruksi pondasi tersebut sehingga tidak menghasilkan penurunan struktur. Pondasi terapung sangat baik digunakan pada daerah dengan daya dukung tanah yang rendah atau pada daerah yang memiliki tanah dengan derajat pemadatan yang bervariasi. Hal ini dikarenakan karakteristik pondasi terapung yang membagi gaya ke area kontak yang sangat besar sehingga seluruh area kontak tersebut hanya mengalami tegangan yang relatif kecil. Namun demikian, karena kapasitas dukung pondasi terapung sangat tergantung pada luasan area, maka pondasi terapung menjadi tidak efektif untuk diterapkan pada daerah yang kecil. Salah satu solusi yang dapat digunakan untuk mengatasi permasalahan ini adalah dengan penerapan struktur pelat cangkang (shell structure) pada pondasi terapung untuk meningkatkan luas area bidang kontak pondasi terapung dan tanah. Paper ini membahas optimasi bentuk pelat cangkang yang digunakan pada pondasi terapung agar memiliki daya dukung yang cukup untuk menahan gaya yang ditransferkan oleh struktur atas. Metode algoritma genetik digunakan dalam proses optimasi dimana koordinat dari titik yang menyusun bentuk (shape) struktur cangkang (cn) dipakai sebagai desain variabel. Pada penelitian ini, proses optimasi menggunakan pemodelan dengan 11, 13 dan 15 variabel desain untuk melihat sensitivitas desain variable tersebut terhadap hasil optimasi. Tegangan yang terjadi pada struktur cangkang tersebut di evaluasi dengan Analisa Elemen Hingga dengan perilaku element cangkang seperti model teory pelat Reissner-Midlin. Fungsi tujuan pada penelitian ini adalah meminimalkan penggunaan material untuk membentuk sebuah pondasi terapung dengan fungsi penalti tegangan pada elemen cangkang. [EN] The basic principle of floating foundation is counterforce balancing between the weight of the structure and thetotal weight of the soil (including groundwater) which is displaced by the structure. Floating foundation is effective in areas with low soil bearing capacity because the external load is widely spread that resulting lower stress level in contact area; Hence, it is necessary to design the shape of floating structure that provide adequate uplift whilst also create lower stress level by spreading the external load to wider contact area. This paper discusses the shape optimization of the floating foundations to have sufficient capacity to resist the force transferred by the upper structure whilst also minimize the use of material without resulting element overstress. Genetic algorithm method is used in the optimization process where the coordinates of the points that shape the shell structure (cn) are used as variable designs. In this study, the multivariable optimization using finite element model is investigated . The stress that occurs in the shell structure is evaluated by Finite Element Analysis with the behavior of shell elements based on Reissner-Mindlin plate theory.
Evaluasi Waktu dan Biaya Pelaksanaan Pembangunan Gedung Rektorat Universitas Muhammadiyah Riau Tahap I Jalan Tuanku Tambusai – Pekanbaru Riau: Evaluation of Implementation Time and Cost of Rectorate Building of Universitas Muhammadiyah Riau Phase I Jalan Tuanku Tambusai - Pekanbaru Riau Saifullah, Saifullah; Wanim, Arhan; Boer, Astuti
JURNAL SAINTIS Vol. 17 No. 2 (2017)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (946.138 KB)

Abstract

[ID] Perkembangan teknologi dewasa ini terus memperlihatkan grafik kemajuan yang begitu pesat, hampir di segala bidang. Begitu pula dengan bidang konstruksi gedung yang semakin maju dan berkembang. Pembangunan Gedung Rektorat Universitas Muhammadiyah Riau bertujuan untuk meningkatkan sarana dan prasarana pendidikan Universitas Muhammadiyah Riau itu sendiri. Dalam setiap pembangunan kendala - kendala yang sering dihadapi dalam pelaksanaan pekerjaan adalah terjadinya keterlambatan waktu pelaksanaan pekerjaan. Waktu pelaksanaan pekerjaan merupakan salah satu unsur penting dalam manajemen konstruksi apabila terjadi keterlambatan pekerjaan akan terjadi pula pembengkakan anggaran biaya pekerjaan. Jika dalam suatu pelaksanaan pekerjaan terjadi keterlambatan, maka perlu dilakukan evaluasi waktu pada beberapa aktivitas proyek. Tujuan penelitian ini untuk mengetahui apakah waktu pelaksanaan pekerjaan sudah sesuai dengan waktu rencana awal dan menganalisa kemungkinan memperpendek waktu pelaksanaan dari realisasi lapangan. Dalam penelitian ini, digunakan dua langkah pengumpulan data yaitu observasi lapangan dan wawancara. Untuk mengatasi keterlambatan pekerjaan digunakan dua metode pada Pembangunan Gedung Rektorat Universitas Muhammadiyah Riau, yaitu dengan menggunakan metode kerja lembur dan metode penambahan tenaga kerja baru. Pada metode kerja lembur upah yang harus dibayar kepada pekerja lebih tinggi 1,5 atau 2 kali upah biasa. Sedangkan pada metode penambahan tenaga kerja upah untuk tenaga baru sama dengan pekerja tetap, ditambah dengan biaya transportasi dan uang makan. Berdasarkan hasil analisa pemendekan durasi dilakukan selama 21 hari kerja pada 18 kegiatan pekerjaan yang terdapat pada lintasan kritis. Penambahan biaya dengan metode kerja lembur sebesar Rp.265.842.755,00dengan metode penambahan tenaga kerja baru sebesar Rp.298.472.000,00. Dari kedua metode yang ditinjau didapat bahwa metode kerja lembur lebih efisien dalam penambahan biaya karena jumlah biaya yang dikeluarkan lebih kecil. [EN] Today's technological developments continue to show a graph of progress so rapidly, almost in all areas. Similarly, the construction of buildings that more advanced and growing. Development of Rectorate Building University of Muhammadiyah Riau aims to improve facilities and infrastructure education of Muhammadiyah University of Riau itself. In every development constraint - constraints that often faced in the implementation of work is the occurrence of delay in the implementation of work. Timing of the work is one of the most important elements in construction management in the event of a delay in work will also occur swelling budget work costs. If there is a delay in the implementation of the work, it is necessary to evaluate the time in some project activities. The aims of this study is to determine whether the timing of the implementation of the work is in accordance with the time schedule plan and to analyze the possibility of shortening time. In this study, using two steps of data collection is works observation and interview. To overcome the delay of work using two methods on the Rectorate Building Building University of Muhammadiyah Riau, they are by using method of overtime work and method of addition of new worker. In the method of overtime work wages to be paid to workers is higher 1.5 or 2 times the usual wage. While on the method of adding labor wages for new personnel equal to permanent workers, included with the cost of transportation and money to eat. Based on the results of the crash program analysis conducted during 21 working days on 18 work activities contained on the critical path. The additional cost with the overtime method of Rp.265.842.755,00 with the method of adding new workforce of Rp.298.472.000,00. From the of method showing that methods reviewed, it is found that the overtime method more efficient in adding cost because the amount of expenses is smaller.
Evaluasi Keandalan Sistem Proteksi Kebakaran Pada Bangunan Gedung (Studi Kasus Gedung PT. PLN Wilayah Riau Dan Kepulauan Riau): Reliability Evaluation of Fire Protection SystemsIn building (Case Study of PT. PLN Building in Riau and Riau Islands Region) Ruspianof, Arda Dwi Cahyo; Retno, Deddy Purnomo; Mildawati, Roza
JURNAL SAINTIS Vol. 17 No. 2 (2017)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (513.193 KB)

Abstract

[ID] Bangunan gedung merupakan wujud fisik dari hasil pekerjaan konstruksi yang menyatu dengan tempat kedudukannya, sebagian maupun seluruhnya berada di atas, di dalam tanah dan air, yang berfungsi sebagai hunian atau tempat tinggal, kegiatan keagamaan, kegiatan usaha, kegiatan sosial budaya, maupun kegiatan khusus. Faktor keselamatan menjadi persyaratan penting yang harus dipenuhi oleh suatu bangunan gedung (UURI,2002) Salah satu aspek keselamatan kerja tersebut adalah keselamatan dari bahaya kebakaran maupun ledakan. Kebakaran merupakan suatu peristiwa atau kejadian yang sangat merugikan semua pihak, baik pihak pengelola atau pengguna gedung, pemilik gedung, maupun masyarakat yang berada di sekitar gedung (UURI, 1970). Metode yang digunakan dalam penelitian ini adalah metode analisis deskriptif. Dimana untuk mendapatkan data yang dibutuhkan, dilakukan pengamatan langsung di lapangan. Komponen yang diidentifikasi yaitu kelengkapan tapak, sarana penyelamatan, sistem proteksi aktif dan sistem proteksi pasif. Pengamatan ini dilakukan untuk mengetahui ketersediaan alat proteksi dan Nilai Keandalan Sistem Keselamatan Bangunan (NKSKB) pada gedung PT. PLN Wilayah Riau dan Kepulauan Riau. Hasil dari penelitian ini menyatakan bahwa sistem proteksi kebakaran pada gedung PT. PLN Wilayah Riau dan Kepulauan Riau sebagian besar telah tersedia. Dengan nilai keandalan pada lantai dasar (87,878%), lantai 1 (87,878%), lantai 2 (87,878%), lantai 3 (87,878%), dan lantai 4 (87,878%). Sedangkan nilai keandalan pada gedung PT. PLN Wilayah Riau dan Kepulauan Riau sebesar 86,47%, hal ini berarti menurut Pd–T–11–2005–C nilai keandalan bangunan terhadap bahaya kebakaran adalah andal. [EN] Building is a physical manifestation of the work of construction that blends with its domicile, partly or wholly located above and / or in the soil and / or water, which serves as a dwelling or residence, religious activities, business activities, social culture activities, as well as special events. Safety factors become essential requirements that must be met by a building (Act No. 28 of 2002 Section 1 on Building). One aspect of the work safety is the safety of the danger of fire or explosion. Fire is an event or events that are very detrimental to all parties, either the manager or the user of the building, the owner of the building, and the people who were around the building (Act No. 1 of 1970 Chapter II Article 2 of the Scope of Work Safety). The method used in this research is descriptive analysis method. Where to get the required data, direct observation was conducted in the field. Components were identified as completeness footprint, rescue facilities, active protection system and passive protection system. These observations were made to check the availability of protective devices and Value of Building Safety System Reliability (NKSKB) on building the PT. PLN Region Riau and Riau Islands. The results of this study stated that the fire protection systems in buildings PT. PLN Riau and Riau Islands region has been largely unavailable. With the value on the ground floor (87.878%), 1st floor (87.878%), 2nd floor (87.878%), 3rd floor (87.878%), and the 4th floor (87.878%). While the value of reliability in building the PT. PLN Riau and Riau Islands region at 86.47%, which means according to the Pd-T-11-2005-C value of the reliability of the building against fire is reliably.
Analisis Risiko Pekerja Pengelasan Terhadap Kesehatan Ditinjau Dari Ergonomi Di CV Las Jasa Muda Kota Pekanbaru: Health Risk Analysis of Welding Work from Ergonomics point of view at CV Las Jasa Muda, Pekanbaru City Edigan, Firman; Putra, Abriansyah
JURNAL SAINTIS Vol. 17 No. 2 (2017)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (481.768 KB)

Abstract

[ID] CV Las Jasa Muda Pekanbaru adalah bengkel jasa pengelasan baik rumah tangga maupun industri. Dalam melakukan proses pengelasan masih menggunakan alat yang dipergunakan manusia secara manual sehingga aktivitas dalam melakukan pekerjaan memiliki risiko yang menyebabkan masalah kecelakaan yang berpengaruh terhadap kesehatan. Tujuan penelitian ini adalah untuk menganalisis risiko kesehatan yang berhubungan dengan postur kerja, kebisingan dan durasi kerja. Penelitian ini merupakan penelitian kualitatif yang bersifat deskriptif, yang bertujuan untuk mendapatkan informasi dengan metode wawancara, observasi serta pengukuran REBA, NBM dan kebisingan dimana penelitian ini dilakukan di CV Las Jasa Muda Pekanbaru. Subjek penelitian ini berjumlah 5 informan yaitu seluruh pekerja. Variabel dalam penelitian ini yaitu postur kerja, kebisingan, durasi kerja. Hasil penelitian diketahui bahwa masih banyak terdapat postur kerja yang dapat menyebabkan risiko tinggi bagi kesehatan pekerja yaitu pada angka 9, tingginya tingkat kebisingan yang diterima pekerja sekitar 86-92,7 dB dapat menyebabkan masalah kesehatan serius dan durasi kerja yang cenderung lama membuat pekerja menjadi lelah, serta kebisingan yang melebihi nilai ambang batas yang menyebabkan masalah kesehatan yaitu hipertensi dan stres. Untuk mengurangi risiko dalam bekerja adalah dengan sosialisasi terkait keselamatan dan kesehatan kerja, meningkatkan kesadaran pentingnya kesehatan dan keselamatan bagi pekerja dengan tujuan untuk menciptakan kondisi pekerjaan yang aman serta terjaminnya kesehatan pekerja dan memberikan APD earplug pada pekerja untuk menghindari kebisingan yang berlebih. [EN] CV Las Jasa Muda Pekanbaru is workshop services welding domestic and industry. In welding still used the manually tool that human in activity having risk work that causes trouble accident influence on health. The purpose of this research is to analyze health risks associated with work posture, noise and work duration. The research is qualitative that are descriptive, aims to get information with the interview, observation and measurement of REBA, NBM and noise where the study is done at CV Las Jasa Muda Pekanbaru. The subject this research is 5 informants all workers. This variabel research is work posture, noise, work duration. The results of research known that there are still many work posture that can cause risk high for health workers namely at approximately 9, the high level noise for workers around 86-92,7 dB can cause serious problems health and work duration old workers to make tired, the noise threshold above value that causes health problems that hypertension and stress. To reduce risk of work is to socialize the work safety and health, raise awareness the importance of safety and health for workers with the aim of condition creating of a job that safe and guaranteeing the health and give PPE earplug on workers to avoid the noise excess.
Perbandingan Kuat Tekan Beton Dengan Menggunakan 4 Cara Perawatan: Comparation Compressive Strength Of Concrete By Using 4 Ways Of Curing Supriadi, Supriadi; Dewi, Sri Hartati
JURNAL SAINTIS Vol. 17 No. 2 (2017)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (695.129 KB)

Abstract

[ID] Beton merupakan material paling sering digunakan dalam dunia konstruksi, baik konstruksi bangunan maupun infrastruktur jalan. Sifat beton diketahui akan lebih baik jika kuat tekan betonnya lebih tinggi, dengan demikian mutu beton didasari oleh kuat tekan beton. Semakin besar kuat tekan beton maka semakin baik mutu beton, namun demikian mutu setiap beton sangatlah bervariasi. Hal ini dipengaruhi oleh beberapa faktor salah satunya yaitu curing atau perawatan beton. Usaha perawatan pada umumnya sering terabaikan atau kurang diperhatikan. Penelitian ini bertujuan untuk menentukan cara perawatan beton yang lebih baik. Pada penelitian ini menggunakan sampel beton berbentuk silinder, sampel dicetak dan dibiarkan dalam cetakan ± 24 jam, sampel dibuat sebanyak 36 sampel, Dalam penelitian ini perawatan yang digunakan adalah perendaman dalam air, diselimuti goni, diluar ruangan, didalam ruangan, Dilakukan analisa uji kuat tekan di Laboratorium masing-masing pada umur 7, 14 dan 28 hari, jumlah sampel pada masing-masing setiap jenis perawatan dan umur beton sebanyak 3 sampel. Analisis kuat tekan beton dilakukan dengan SNI 03-2834-2000. Hasil penelitiaan ini menunjukan bahwa beton dengan perawatan direndam dapat meningkat kuat tekan beton, sedangkan untuk beton yang didalam ruangan, diluar ruangan dapat mengurangi kekuatan tekan beton. Setelah dilakukan perhitungan dalam penelitian ini didapatkan hasil kuat tekan rata-rata beton pada umur 28 hari yang direndam diperoleh sebesar 18.05 MPa, dan selimuti goni didapat sebesar 17,67 MPa, sedangkan untuk beton yang didalam ruangan, diluar ruangan diperoleh sebesar 16,24 MPa dan 14,95 MPa, pada pekerjaan dilapangan sangat sulit mengaplikasikan jenis perawatan direndam di dalam air, maka dapat diambil jenis perawatan diselimuti goni karena memiliki nilai kuat tekan beton melebihi mutu beton rencana dibanding perawatan di luar ruangan dan di dalam ruangan. [EN] Concrete is the most common material used in the construction world, both building construction and road infrastructure. The nature of the concrete is known to be better if the compressive strength of the concrete is higher, thus the quality of the concrete is based on the compressive strength of the concrete. The greater the compressive strength of the concrete the better the quality of the concrete, however the quality of each concrete varies greatly. This is influenced by several factors one of which is curing or concrete treatment. Nursing care in general is often overlooked or poorly cared for. This study aims to determine how better concrete treatment. In this study using cylindrical concrete sample, the sample is printed and left in the mold ± 24 hours, the sample is made as many as 36 samples. In this research the treatment used is water immersion, covered by jute, outside the room, in the room, in each laboratory at the age of 7, 14 and 28 days, the number of samples in each type of treatment and the concrete age of 3 samples. Analysis of concrete compressive strength was done with SNI 03-2834-2000. The results of this research show that concrete with soaked treatment can increase the compressive strength of concrete, while for concrete inside the room, outside the room can reduce the compressive strength of concrete. After calculation in this research got result of compressive strength strength of concrete average at 28 days soaked obtained by 18.05 MPa, and blanket goni obtained 17,67 MPa, while for concrete inside room, outside room obtained equal to 16,24 MPa and 14,95 MPa, in the field work is very difficult to apply the type of treatment soaked in the water, it can take the type of treatment covered with jute because it has a value of concrete compressive strength exceeds the quality of concrete plans compared to outdoor treatments and indoors.
Studi Karakteristik Fondasi Pelat Tipis Dengan Pengaku Tiang “+” Pada Tanah Granuler Melalui Uji Eksperimen Dan Analisis Pemodelan Menggunakan Software Abaqus: Study of Characteristics of Thin Plate Foundation with Stiffener "+" in Granular Soil through Experimental Test and Analysis Modeling Using Abaqus Software Syarif, Firman; Adi, Agus Darmawan; Saputra, Ashar
JURNAL SAINTIS Vol. 17 No. 2 (2017)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1271.702 KB)

Abstract

[EN] The amount of damage that happened in Indonesian road is the impact of high traffic load exceeds the carrying capacity of the pavement. To reduce the problems that occur on the pavement the good systems of pavement are built, various studies conducted to produce a creative innovation in order to evaluate and improve the performance of the pavement system. this study has developed a new system of foundation with pile "+" to make the connection between plate and minipile (joint) becomes better. In this study, three models of foundation will be tested by loading test (following ASTM D 114 381 and ASTM D 3689 Pile Under static axial compressive load) to observe and analyze the behavior of the foundation model by loading centric and eccentric. In addition to laboratory tests this research also modeling analysis with Abaqus software to observe and analyze the behavior of the foundation model in terms of deformation and settlement. The results showed the distances between pile and pile provides a significant contribution in reducing the settlement in the foundation when given a maximum load of 20 kN, where is the foundation 1 had short distance between the other foundation the deformation and settlement is the smallest. The length of pile also give significant contribution to reduce the settlement like in foundation 3 that have 20 cm length of the pile have settlement and deformatioan smaller than the foundation 2 that have 10 cm length of the pile
Karakteristik Respon FPSO Konversi Tanker Ukuran 310 M: Response Characteristics of FPSO Conversion of Tanker Size 310 M Adnyani, Luh Putri; Harahap, Rima Gusriana
JURNAL SAINTIS Vol. 19 No. 1 (2019)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1943.973 KB) | DOI: 10.25299/saintis.2019.vol19(1).2524

Abstract

[ID] Floating Production Storage and Offloading (FPSO) sudah banyak beroperasi di seluruh dunia dan akan lebih banyak lagi yang akan dibangun untuk eksplorasi dan eksploitasi laut dalam. Penelitian ini menunjukkan respon dari FPSO dengan ukuran 310 m lpp dan membandingkan nilai respon yang didapat dengan experiment yang didapatkan oleh Kim. Penelitian dimulai dengan memodelkan FPSO sesuai dengan data yang ada dan melakukan analisa dengan menggunakan pemodelan numeric. Dari hasil analisa didapatkan bahwa respon dari FPSO sangat dipengaruhi oleh gerakan dari FPSO akibat gelombang dan bervariasi terhadap sudut. Respon gaya geser longitudinal maksimum pada sudut 120o. Respon gaya geser transversal maksimum pada sudut 90o. Respon gaya geser vertikal maksimum pada sudut 90o. Respon roll moment maksimum pada sudut 90o. Respon pitch moment maksimum pada sudut 120o. Respon yaw moment maksimum pada sudut 60o. [EN] Floating Production Storage and Offloading (FPSO) has a lot of operating around the world and there will be more to be built for the exploration and exploitation of deep sea. This study shows the response of the 310 m LPP FPSO and compares the responses with experiment result by Kim [1]. The study begins by modeling the FPSO in accordance with the existing data and to analyze using numerical modeling. From the results found that the response of the FPSO is strongly influenced by the heading and motion of the FPSO. Maximum longitudinal shear force in 120o, maximum transverse shear force in 90o, maximum vertical shear force in 90o, maximum roll moment in 90o, maximum pitch moment in 120o, maximum yaw moment in 60o.
Studi Pengaruh Komposisi Pengisi Serat Alam Kayu Galam (Melalueca Leucadendra) Bentuk Serutan pada Sifat Mekanik dan Mikrostruktur Komposit Poliester Sebagai Material Untuk Aplikasi Bilah Kincir Angin: Study of Composite Composition Effect of Natural Shavings of Galam Wood Fiber (Melalueca Leucadendra) on the Mechanical and Microstructure Properties of Polyester Composites as Materials for the Windmill Blades Application Laksono, Andromeda Dwi; Ismail, Ika; Ningrum, Cahyaningtyas Ratna
JURNAL SAINTIS Vol. 19 No. 1 (2019)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1349.613 KB) | DOI: 10.25299/saintis.2019.vol19(1).2629

Abstract

[ID] Sebagai alternatif sumber energi konvensional, energi angin merupakan salah satu energi alternatif yang banyak dikembangkan. Pemanfaatan energi ini tidak lepas dari alat pengonversinya, kincir angin. Salah satu komponen kincir angin yang cukup penting adalah bilah. Bilah sering mengalami masalah berupa pengikisan pada bagian permukaannya akibat benturan dengan oleh partikel yang terbawa oleh angin yang dapat mengakibatkan fungsi bilah tidak optimal. Sehingga, dibutuhkan material pengganti yang lebih kuat tetapi ringan, yakni komposit. Komposit yang digunakan adalah komposit serat alam (serat Melaleuca leucadendra-poliester). Dalam penelitian ini akan dianalisa pengaruh fraksi volume serat berbentuk serutan terhadap kekuatan tarik, kelenturan dan ketangguhan. Pembuatan komposit serat alam Kayu Galam (Melaleuca leucadendra)-poliester dengan cara mencampurkan resin, katalis dan serat Kayu Galam yang berbentuk serutan kemudian dicetak didalam cetakan yang telah dilapisi alumunium foil. Sampel kemudian dilakukan pengujian kekuatan tarik dengan standar ASTM D 638, pengujian tekuk dengan standar ASTM D 790 serta pengujian impak dengan standar ASTM D 6110. Metode yang digunakan dalam pembuatan adalah metode hand lay-up. Hasil dari penelitian ini adalah nilai optimum yang dicapai yaitu 70% serat pada semua uji mekanik. Didapatkan nilai kekuatan tarik berada sebesar 13,07 MPa, kekuatan tekuk optimum 36,8 MPa dan nilai optimum dari kekuatan impak sebesar 590,39 MPa. [EN] As an alternative to conventional energy sources, wind energy is one of the many alternative energies that have been developed. The utilization of this energy is inseparable from its conversion tool, windmills. One component of the windmill that is quite important is the blade. Blades often experience problems in the form of erosion on the surface due to collisions by particles carried by the wind which can cause the blade function to be not optimal. So, it takes a replacement material that is stronger but lighter, namely composite. The composites used were natural fiber composites (Melaleuca leucadendra-polyester fibers). In this study, the effect of the volume fraction of fiber in the form of shavings on tensile strength, flexibility, and toughness will be investigated. The making of natural fiber composites of Galam Wood (Melaleuca leucadendra) -polyester by mixing resin, catalyst, and Galam Wood fiber in the form of shavings is then printed in a mold that has been coated with aluminum foil. Samples were then tested for tensile strength with ASTM D 638 standard, bending test with ASTM D 790 standard and impact testing under ASTM D 6110 standard. The method used in manufacturing was the hand lay-up method. The result of this study is the optimum value achieved is 70% fiber in all mechanical tests. Obtained tensile strength values of 13.07 MPa, the optimum bending strength of 36.8 MPa and the optimum value of impact strength of 590.39 MPa.
Studi Pengaruh bukaan Corewall terhadap Kinerja Lateral Sistem Struktur yang Mengalami Beban Gempa: Study of The Effect of CoreWall Openings On Structural Lateral Performance Under Earthquake Loads Gunawan, Anggi; Dewi, Sri Hartati; Adha, Augusta
JURNAL SAINTIS Vol. 19 No. 1 (2019)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2820.878 KB) | DOI: 10.25299/saintis.2019.vol19(1).2803

Abstract

[IN] Untuk mengurangi pengaruh defleksi yang berlebihan pada gedung akibat beban gempa, dibutuhkan struktur yang dapat mereduksi pengaruh dari beban gempa yaitu struktur dinding geser. Corewall merupakan modifikasi dari struktur dinding geser yang dapat menahan pengaruh beban lateral dan efek torsi dari adanya eksentrisitas serta juga dapat difungsikan sebagai ruang lift. Dalam perencanaannya, corewall diberi bukaan yang difungsikan sebagai pintu untuk lift. Dengan adanya bukaan dapat memberikan pengaruh terhadap kekakuan pada corewall. Tujuan dari penelitian ini yaitu melakukan analisis terhadap kinerja sistem struktur frame dan corewall dengan bukaan dalam menahan beban lateral pada gedung tidak beraturan. Metode yang digunakan adalah analisis dinamik respon spektrum berdasarkan peraturan SNI 1726-2012. Tahapan awal dalam penelitian ini adalah menentukan posisi letak corewall yang yang terbaik. Setelah didapat posisi corewall yang optimal, selanjutnya dilakukan investigasi terhadap 12 tipe bukaan pada corewall untuk mengetahui model bukaan dengan kinerja deformasi akibat beban gempa. Hasil peneitian ini menunjukkan dari ke-12 tipe bukaan pada corewall, bukaan corewall pada model 11 lantai 7 untuk arah Y, kinerja simpangan antar lantai melebihi batasan simpangan antar lantai ijin sebesar 0,19%. Selain dari model 11, kinerja simpangan antar lantai pada model bukaan yang lain tidak melebihi dari batasan simpangan ijin. [EN] Structure equipped with shear wall is effective to reduce the effect of excessive deflection due to earthquake load. Core wall is a modification of shear wall that can withstand lateral loads and torsion effects due to eccentricity whilst also functioned as elevator room. Core wall is designed with openings that functioned as access path to elevators. The openings can influence the stiffness of core wall. This study discusses the analysis of irregular frame structure systems and core wall with openings against lateral loads. The method used in this paper is the dynamic response spectrum method based on Standar Nasional Indonesia (SNI) code 1726-2012. The initial stage of this research was to determine the position of the best core wall location. Having obtained the optimal core wall position, an investigation of 12 types of openings on the core wall was carried out to determine the opening model with the best lateral deformation performance due to earthquake load. The results of this research show the best lateral performance of 12 types of opening of core wall. The worst core wall openings model no. 11 shows the increasing inter-floor capacity by 0.19% from the requirements set by SNI 1726-2012. Meanwhile, other models show the performance of inter-floor deviation does not exceed the allowable deviation based on SNI the given code.
Tinjauan Proses Pengolahan Air Baku (Raw Water) Menjadi Air Bersih Pada Sarana Penyediaan Air Minum (Spam) Kecamatan Rangsang Kabupaten Kepulauan Meranti: Review of Raw Water Processing Process to Clean Water at Drinking Water Supply (SPAM) Rangsang, Meranti District Harmiyati, Harmiyati
JURNAL SAINTIS Vol. 18 No. 1 (2018)
Publisher : UIR Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1773.014 KB) | DOI: 10.25299/saintis.2005.vol8(2).2808

Abstract

[ID] Di kabupaten Kepulauan Meranti khususnya Masyarakat Kecamatan Rangsang pada umumnya menggunakan air hujan dan air Sungai sebagai kebutuhan air bersih sehari-hari, jika pada musim kemarau masyarakat pada umumnya sulit mendapatkan air bersih. Dengan adanya Sarana penyediaan air bersih yang dibangun oleh pemerintahan Kabupaten Kepulauan Meranti yaitu Sarana Penyediaan Air Minum (SPAM) ini sangat membantu dalam memenuhi kebutuhan air bersih masyarakat. Dilihat secara warna, air bersih yang di produksi oleh SPAM Kecamatan Rangsang berwarna kecoklatan, dilihat dari segi warna hampir sama dengan air baku SPAM Kecamatan Rangsang tersebut. Pada SPAM Kecamatan Rangsang ini proses pengolahan air bersih menggunakan metode koagulasi, flokulasi, sedimentasi dan filtrasi. Peneliti mencoba meninjau apakah proses-proses pengolahannya telah sesuai dengan metode yang telah di terapkan, mengetahui kualitas air bersih yang dihasilkan serta mengetahui masalah-masalah yang terdapat pada SPAM Kecamatan Rangsang tersebut. Dari hasil penelitian yang dilakukan untuk pemprosesan air bersih adanya proses yang tidak dilakukan yaitu tidak dilakukan pembubuhan zat Koagulan, hal tersebut dikarenakan zat-zat Koagulan yang ada di SPAM Kecamatan Rangsang tidak tersedia untuk saat ini. Untuk kualitas air bersih yang di produksi SPAM Kecamatan Rangsang tidak memenuhi standar kualitas air bersih berdasarkan peraturan menteri kesehatan nomor 416 tahun 1990 tentang “syarat-syarat dan pengawasan kualitas air” yaitu air bersih sesuai dengan hasil uji laboratorium dinas kesahatan kota pekanbaru pada tanggal 13 November 2017, serta terdapat beberapa alat yang tidak beroperasi, yaitu rusaknya 1 buah pompa Intake dan 1 buah pompa distribusi [EN] In the Meranti Islands district, especially in the Subdistrict of Rangsang District, the people generally use rain water and river water as their daily clean water needs, if in the dry season the community in general is difficult to get clean water. With the availability of clean water facilities built by the government of the Meranti Islands Regency, the Drinking Water Supply Facility (SPAM) is very helpful in meeting the community's clean water needs. Viewed in color, the clean water produced by SPAM in the District of Rangsang is brownish in color, in terms of color it is almost the same as the SPAM raw water in the District of Rangsang. At SPAM in the District of Rangsang, the process of treating clean water uses the methods of coagulation, flocculation, sedimentation and filtration. Researchers try to review whether the treatment processes are in accordance with the methods that have been applied, find out the quality of clean water produced and find out the problems found in the SPB Subdistrict. From the results of research conducted for the processing of clean water there is a process that is not done that is not done by adding coagulant substances, it is because the coagulant substances in SPAM Subdistrict, Rangsang District are not available at this time. For the quality of clean water produced by SPAM in the Subdistrict of Rangsang District, it does not meet clean water quality standards based on the Minister of Health Regulation number 416 of 1990 concerning "requirements and quality control of water", which is clean water in accordance with the results of laboratory tests on the city health office Pekanbaru on November 13 2017, and there are some tools that are not operating, namely the damage of 1 Intake pump and 1 distribution pump.

Page 11 of 23 | Total Record : 224