Journal of Energy and Electrical Engineering (JEEE)
Published by Universitas Siliwangi
ISSN : -     EISSN : 2720989X     DOI : -
JEEE is a journal that contains research results in the field of Energy and Electrical Engineering. This journal can be used as a source of scientific information for researchers, researcher academia or institution, and government agencies. The topic focused on Power Systems, Control Systems, Energy Management and Electrical Materials. JEEE is published by Teknik Elektro Universitas Siliwangi and managed to be issued twice in every volume on October and April.
Articles 119 Documents
Estimasi Posisi Vertikal Elevator pada Purwarupa AGV Logistik Kristi, David; Nugraha, MB
Journal of Energy and Electrical Engineering Vol 5, No 1: Oktober 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v5i1.8560

Abstract

Industri pergudangan telah mengalami transformasi signifikan melalui otomasi yang merupakan bagian dari Revolusi Industri 4.0. Transformasi ini melibatkan berbagai jenis pergudangan, termasuk yang komersial, rumah sakit, dan fasilitas PLTN. Penggunaan robot dalam proses otomasi penyimpanan telah mengubah gudang menjadi entitas otomatis sepenuhnya, meskipun membutuhkan investasi awal yang substansial. Sebagai alternatif, penggunaan robot picker memungkinkan pengambilan barang tanpa perlu perancangan awal yang rumit, mengoptimalkan infrastruktur yang sudah ada. Meskipun Indonesia masih mengimpor robot otomasi, penelusuran teknologi robot picker sedang dalam proses. Penelitian lebih mendalam diperlukan, khususnya dalam konteks sistem pengangkatan robot, terutama untuk mendukung pertumbuhan pesat industri pergudangan. Penelitian ini berfokus pada perancangan sistem vertikal elevator dan gripper untuk AGV logistik, dengan perbandingan metode estimasi ketinggian untuk mencapai akurasi terbaik dalam hasil pergerakan elevator. Dari hasil pengujian, keberhasilan pengujian hanya didapatkan 31,25% dan 39,38% yang kemungkinan dihasilkan oleh sistem girboks mengalami slip sehingga akurasi yang didapatkan sangat rendah.
ANALISIS POTENSI DAYA LISTRIK PLTS ATAP DI GEDUNG DIREKTORAT POLITEKNIK NEGERI SEMARANG DENGAN PERANGKAT LUNAK PVSYST Karuniawan, Eriko Arvin; Sugiono, Friska Ayu Fitrianti; Larasati, Pangestuningtyas Diah; Pramurti, Adeguna Ridlo
Journal of Energy and Electrical Engineering Vol 4, No 2: 13 April 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v4i2.6683

Abstract

Pemerintah dalam tujuannya mencapai target bauran energi terbarukan sebesar 23% pada tahun 2025 terus mendorong masyarakat dalam menggunakan energi terbarukan terutama di jenis energi surya melalui pemanfaatan PLTS Atap. Dalam pembangunan sistem PLTS atap, perlu dilakukan perancangan sistem PLTS terlebih dahulu, untuk mengkalkulasi energi yang dapat dihasilkan pada sistem tersebut. Perhitungan potensi daya listrik perlu dilakukan karena merupakan salah satu dari tahap perencanaan dalam pembangunan sistem PLTS. Polines(Politeknik Negeri Semarang) sebagai Perguruan Tinggi Negeri hendaknya dapat ikut berkontribusi dalam mengembangkan dan mensosialisasikan peraturan pemerintah tersebut dengan cara mengembangkan dan mensosialisasikan PLTS Atap di lingkungan Polines. Untuk itu dalam penelitian ini dilakukan perhitungan potensi energi listrik dari PLTS Atap jika dilakukan pengaplikasian teknologi PLTS Atap di lingkungan kampus Polines sebagai salah satu tahapan dalam perancangan suatu sistem. Dari simulasi PVSyst yang telah dilakukan maka dapat didapat potensi energi listrik di Gedung Direktorat Polines sebesar 9321 kWh/tahun atau 25,56 kWh/hari dengan kapasitas PLTS sebesar 6,08 kWp. Untuk Performance Ratio dari sistem PLTS ini sebesar 0,82.
PERANCANGAN ANTENA MIKROSTRIP PATCH DOUBLE LAYER BERFREKUENSI 2,4 GHZ UNTUK TEKNOLOGI ZIGBEE Marini, Sri; Supratno, Setyo -; Pitaloka, Habibah Fiola
Journal of Energy and Electrical Engineering Vol 5, No 2: April 2024
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v5i2.10572

Abstract

Sistem Peringatan Dini Bencana Banjir Menggunakan Triple Node IoT dan Multisensor Sumardiono, Arif; Alimudin, Erna; Zaenurohman, Zaenurohman
Journal of Energy and Electrical Engineering Vol 4, No 2: 13 April 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v4i2.5558

Abstract

Banjir merupakan bencana alam yang harus di waspadai oleh masyarakat sekitar aliran sungai. Fenomena bencana banjir sering menyebabkan kerusakan harta benda bahkan sampai merenggut korban jiwa [1]. Banjir disebabkan oleh daerah resapan atau saluran air yang tidak berfungsi dengan baik, serta adanya intensitas curah hujan yang tinggi menyebabkan aliran masuk lebih besar dibandingkan aliran keluar [2]. Maka perlu dibuat media komunikasi yang dapat mengirimkan informasi kepada masyarakat jika akan ada banjir yang datang. Pengumpulan data pada daerah sekitar sungai seperti ketinggian aliran sungai, curah hujan di aliran sungai serta kelembaban udara dialiran sungai sangat diperlukan untuk dapat diolah sehingga dapat prediksi akan adanya banjirData – data tersebut diambil dengan menggunakan beberapa sensor seperti rain gauge  (sensor curah hujan), anemometer (sensor kecepatan angin), sensor SR04T ( pendeteksi ketinggian air), sensor DHT11 ( sensor suhu dan kelembaban udara). Sensor tersebut diintegrasikan menggunakan arduino mega lalu di kirimkan datanya melalui modul gsm sim 800L. Data tersebut akan dikirimkan ke sistem cloud dan database, serta ditampilkan pada website. Sistem monitoring telah bekerja mengirimkan data – data yang diperlukan. Data – data tersebut menghasilkan bahwa saat keadaan hujan keadaan lingkungan disekitar sistem pernodenya mempunyai suhu 250C sampai 270C. Kelembaban 99 Rh, Ketinggian Air 102 cm sampai 104 cm, curah hujan 20 ml/s dan kecepatan angin antara 2 m/s sampai 6 m/s.
PENENTUAN KUANTITAS PAKAN IKAN BERBASIS FUZZY LOGIC Taufiqurrahman, Imam; Nurdiansyah, Rian; Risnandar, Muhammad Aris; Rahayu, Andri Ulus; Faridah, Linda
Journal of Energy and Electrical Engineering Vol 4, No 2: 13 April 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v4i2.6882

Abstract

Perkembangan teknologi dalam bidang perikanan berhasil menghasilkan alat pemberi pakan otomatis yang mampu memberikan kemudahan dalam mengatur waktu dan durasi pemberian pakan. Namun perkembangan ini masih bisa ditingkatkan dengan memperhatikan tingkat pemberian pakan/ feeding rate (FR) di suatu kolam budidaya ikan agar pemberian pakan optimal dan tidak berlebihan. Penentuan FR ini pada prakteknya dipengaruhi oleh beberapa faktor seperti berat atau umur ikan, banyaknya oksigen terlarut dalam air, suhu air dan tingkat kejernihan (turbidity) air. Untuk memperhitungkan pengaruh faktor-faktor tersebut terhadap FR dari alar pemberi pakan otomatis akan digunakan metode fuzzy logic sehingga bisa didapatkan nilai optimal pemberian pakan berdasar pertimbangan faktor-faktor tersebut. Dalam penelitian ini akan dilakukan simulasi penerapan sistem penentuan penyesuaian nilai FR dengan memperharikan faktor-faktor tersebut menggunakan aplikasi MATLAB.
DESAIN DAN SIMULASI DC-DC SHUNT BUCK CONVERTER EFISIENSI TINGGI MENGGUNAKAN KONTROL LOGIKA FUZZY Muladi, Sofian Ichsan; Wiryajati, I Ketut; Supriono, Supriono
Journal of Energy and Electrical Engineering Vol 5, No 2: April 2024
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v5i2.10465

Abstract

Abstract                The development of electronic component and circuit technology is able to produce a direct current voltage power supply system or more briefly DC (Direct Current), which is produced by converting the input voltage to the desired output voltage form (DC to DC converter). In its development, there are three types of DC to DC converter types, namely, boost converter (step up), buck converter (step down),and  buck-boost converter (step up and step down). Of the three types, there have been several developments that have been carried out, as one example is the shunt buck converter that will be used in this study.                The simulation test result of the shunt buck converter circuit carried out by means of 3 approaches, namely open loop, close loop with PID control, and close loop with fuzzy logic control can produce an output voltage value that is smaller than the input voltage value given, this is accordance with the function of the buck converter itself. In addition, the efficiency value obtained from the three experiments with the previously mentioned approaches has a fairly high value ranging from 65% - 99% with the highest efficiency obtained being 98,7%. Keyword: Buck Converter, Efficiency, Fuzzy Logic, PID, Shunt Abstrak                                Perkembangan teknologi komponen dan rangkaian elektronika mampu menghasilkan sistem penyedia daya tegangan arus searah atau lebih singkatnya DC (Direct Current), yang dihasilkan dengan cara mengkonversi tegangan masukan ke bentuk tegangan keluaran yang diinginkan (DC to DC converter).Pada perkembangannya ada tiga tipe tipe DC to DC converter yaitu, boost converter (step up), buck converter (step down), dan buck-boost converter (step up dan step down). Dari tiga tipe tersebut sudah ada beberapa pengembangan yang telah dilakukan, sebagai salah satu contohnya yaitu shunt buck converter yang akan digunakan pada penelitian ini.                                Hasil uji simulasi rangkaian shunt buck converter yang dilakukan dengan cara 3 pendekatan yaitu open loop, close loop dengan kontrol PID, dan close loop dengan kontrol logika fuzzy dapat menghasilkan nilai tegangan keluaran yang lebih kecil dari nilai tegangan masukan yang diberikan, hal ini sesuai dengan fungsi dari buck converter itu sendiri. Selain itu, nilai efisiensi yang didapatkan dari ketiga percobaan dengan pendekatan yang telah disebutkan sebelumnya memiliki nilai yang terbilang tinggi yang berkisar antara 65% - 99% dengan efisiensi tertinggi yang didapatkan adalah 98,7%.Keyword: Buck Converter, Efisiensi, Logika Fuzzy, PID, Shunt.
Analisis Kelayakan Instalasi Listrik di PT. Komatsu Indonesia (KBN Plant) Sidiq, Riky Permana; Priatna, Edvin; Usrah, Ifkar
Journal of Energy and Electrical Engineering Vol 5, No 1: Oktober 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v5i1.7850

Abstract

PT. Komatsu Indonesia (KBN Plant) merupakan perusahaan yang bergerak dibidang konstruksi dan pertambangan, sejak awal beroperasi pada tahun 2005 PT. Komatsu Indonesia terus berkembang pesat seiring dengan perkembangannya tentunya kebutuhan pasar akan meningkat begitupun dengan perlatan yang membutuhkan energi listrik akan ikut bertambah sama halnya dengan daya listrikpun mengalami penambahan. Dengan bertambahnya kapasitas, beban serta instalasi dikhawatirkan kinerja instalasi kelistrik akan menurun, termasuk sistem1penghantar, sistem1pengaman instalasi1yang1digunakan dan sistem1pembumian. Berdasarkan permasalahan tersebut, penelitian ini bertujuan untuk mengetahui kelayakan sistem instalasi listrik yang ada di PT. Komatsu Indonesia (KBN Plant) seperti sistem penghantar, sistem pengaman dan sistem pembumian. Berdasar hasil penelitian sistem instalasi di PT. Komatsu Indonesia (KBN Plant) sudah memenuhi standar yang berlaku. Sistem penghantar, sistem pengaman, dan sistem grounding menunjukan hasil yang baik sesuai standard PUIL 2011, khususnya nilai setiap perhitungan tidak melebihi standar PUIL 2011 seperti pengaman pada panel MDB Utility nilai KHA setelah dihitung sebesar 47.48 A dan bedasar PUIL 2011 nilai pengaman yang dipakai sebesar 50 A, tentunya pengaman terpasang sudah memenuhi dan bahkan melebihi standar diamna nilai rating arus pada pengaman terpasang sebesar 160 A. Nilai arus tersebut memiliki nilai yang cukup jauh dari hasil perhitungan dari beban saat ini.Kata Kunci ; PUIL 2011, Luas Penampang, KHA, Pengaman, Grounding.
PERENCANAAN SISTEM PROTEKSI PENANGKAL PETIR DI STADION SAKTI LODAYA KECAMATAN CISAYONG KABUPATEN TASIKMALAYA Mulyadi, Zaki; Usrah, Ifkar; Andang, Asep
Journal of Energy and Electrical Engineering Vol 4, No 2: 13 April 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v4i2.6118

Abstract

Petir merupakan peristiwa peluahan listrik antara suatu awan bermutan dengan bumi, atau antar awan bermuatan dengan awan bermuatan lainnya. Sistem proteksi petir dirancang untuk melindungi suatu area dari dampak sambaran petir. Wilayah Indonesia sendiri memiliki intensitas sambaran petir yang cukup tinggi. Penelitian ini bertujuan untuk merencanakan (SPP) Sistem Proteksi Petir Eksternal dan mengetahui efektifitas sistem penangkal petir yang akan terpasang pada Stadion Sakti Lodaya Kecamatan Cisayong Kabupaten Tasikmalaya. Standar yang digunakan dalam menganalisa Sistem Proteksi Petir (SPP) adalah SNI 03-7015-2004 dan Peraturan Umum Instalasi Penangkal Petir (PUIPP). Dalam penelitian ini metode yang digunakan adalah Metode Sudut Proteksi, Metoda Bola Bergulir. Menurut hasil analisa yang telah dilakukan, sistem proteksi petir pada Stadion Sakti Lodaya Kecamatan Cisayong Kabupaten Tasikmalama belum terpasang proteksi penangkal petir , karenanya harus memasang proteksi yang memenuhi zona proteksi petir sesuai standar yang dibutuhkan. Berdasarkan hasil analisa yang telah dilakukan sistem proteksi petir pada Stadion Sakti Lodaya Kecamatan Cisayong Kabupaten Tasikmalama sudah termsuk aman.
Prototype of CO, CO2 , UV Light, Temperature and Humidity Detection Device Based on IoT and Solar Cells Tejaleksono, Gunawan; Notosudjono, Didik; Machdi, Agustini Rodiah; Adzikri, Fikri; Rahayu, Andri Ulus
Journal of Energy and Electrical Engineering Vol 5, No 2: April 2024
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v5i2.10321

Abstract

Exposure to air pollution, excessive ultraviolet (UV) light, and changes in environmental temperature and humidity can have serious impacts on human health. Therefore, a tool design was created that combines Solar Cell-based technology and the Internet of Things (IoT) to detect potential dangers from air pollution, exposure to UV rays, and changes in environmental temperature and humidity. This tool uses an ESP32 microcontroller as its brain, which allows data to be collected from the sensors used. The sensors used include the MQ2 Sensor for toxic gas detection, the MQ135 Sensor for CO2 pollutant gas detection, the UV Sensor for monitoring harmful UV radiation, and the DHT11 Sensor for measuring environmental temperature and humidity. The information collected by these sensors is displayed in real-time via an OLED display, giving users an instant understanding of the level of danger that may exist in their surroundings. Apart from that, this tool uses Solar Cells as a power source, so it can operate independently and is environmentally friendly. This tool has great potential for use in a variety of environments, including residential areas, work spaces and open areas. It helps society as a whole to maintain their health and safety by providing accurate and real-time information about the dangers that may be around them. KEYWORDS: DHT-11, ESP-32, GUVA S12SD, Internet of Things (IoT), MQ-2, MQ-135 Solar Cell.
Karakteristik Peluahan pada Permukaan Akrilik di Sekeliling Elektroda Plat nurdiansyah, rian; ardiansyah, neris peri; khayam, umar
Journal of Energy and Electrical Engineering Vol 5, No 1: Oktober 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v4i1.5628

Abstract

Lebih dari 50% kerusakan pada instrumen sistem daya disebabkan oleh cacat isolator. Cacat isolator ini terkait erat dengan peluahan sebagian karena selain memicu terjadinya kerusakan pada isolator juga bisa menjadi pertanda awal kerusakan isolator. Oleh karena itu, deteksi dan pengukuran peluahan sebagian sangat penting untuk mengetahui keberadaan dan sifat kerusakan pada isolator yang diuji, sehingga tindakan pencegahan dapat diambil sesegera mungkin ketika kerusakan terjadi dan mencegah peningkatan kerusakan dan menyebar ke peralatan lain dengan fungsi vital ke sistem daya. Dalam percobaan ini, pengujian dan pengukuran peluahan sebagian pada bahan isolator padat akrilik dengan mengacu pada standar IEC 60270. Hasil pengukuran Partial Discharge Inception Voltage (PDIV) pada isolator menghasilkan kesimpulan bahwa peluahan sebagian yang terjadi adalah peluahan sebagian permukaan, karena nilai PDIV jauh lebih kecil dari nilai tegangan breakdown akrilik dan lebih mendekati tegangan breakdown udara.