cover
Contact Name
Aris Fiatno
Contact Email
abi.fiat@gmail.com
Phone
+6282113270340
Journal Mail Official
teknikindustri@universitaspahlawan.ac.id
Editorial Address
Jl. Tuanku Tambusai No. 23 Bangkinang Kampar, Riau » Tel / fax : (0762) 216 77 / (0762) 216 77
Location
Kab. kampar,
Riau
INDONESIA
Jurnal Teknik Industri Terintegrasi (JUTIN)
ISSN : 26208962     EISSN : 26208962     DOI : 10.31004jutin
Jurnal Teknik Industri Terintegrasi merupakan jurnal yang dikelola oleh Program Studi Teknik Industri Fakultas Sains dan Teknologi Universitas Pahlawan Tuanku Tambusai yang menjebatani para peneliti untuk mempublikasikan hasil penelitian di bidang ilmu teknik dan teknik industri mencakup proses manufaktur, kegagalan dan rekayasa material, perawatan berbasis keandalan, keselamatan kerja, perancangan sistem kerja dan ergonomi, pengendalian dan penjaminan mutu, tata letak fasilitas, penelitian operasional, kewirausahaan dan pengembangan bisnis
Arjuna Subject : -
Articles 1,566 Documents
Optimasi Rute Distribusi Pertamax dari FT Wonoayu Menggunakan Ant Colony Optimization pada CVRP Asimetris Calista Aulia Haqi; Nano Koes Ardhiyanto
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64550

Abstract

Secondary distribution of Pertamax from a terminal to fuel stations (SPBU) requires efficient routes to reduce travel distance, fleet size, and operating cost. This study optimizes the distribution routes from the Wonoayu Fuel Terminal (FT), Sidoarjo, to 81 SPBU, formulated as a Capacitated Vehicle Routing Problem (CVRP) with an 82×82 asymmetric distance matrix. Ant Colony Optimization (30 ants, 50 iterations, α = 1, β = 2, ρ = 0.5) was applied with a 40 kL tanker capacity and at most two trips per truck per day. All 81 SPBU are served in 11 multi-drop trips with a total distance of 822.78 km per day (best of 30 replications), 70.76% shorter than the conventional round-trip system of 2,814.00 km. This equals the nearest-neighbor result, while the savings algorithm gives a shorter distance (758.47 km) but needs 13 trips. The average load factor reaches 94.4% and only 6 tankers are required. A capacity analysis shows that this fleet is sufficient in the peak month but 7 units are needed at the terminal design load.
Analisis Variasi Celah Kekuatan Tarik Brazing Kuningan CuZn40 Pada Baja Karbon Rendah St 40 Yosua Hotman Aritonang; Mukhnizar Mukhnizar; Zulkarnain Zulkarnain
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64576

Abstract

Brazing is a long-established and widely used metal-joining method. It involves joining metals using a filler material with a melting point above 450 °C, while keeping the base metals below their melting points. This study aims to investigate the effect of joint gap widths specifically 0.10 mm and 0.30 mm on the tensile strength of ST40 steel joints brazed with CuZn40 brass; to determine the optimal joint gap width for achieving maximum tensile strength; and to identify the failure modes and joint efficiency of the ST40 steel–CuZn40 brass joints in terms of tensile strength. The results indicate that varying the joint gap width between 0.10 mm and 0.30 mm does not significantly affect the optimal tensile strength. A gap width of 0.30 mm yielded a higher average tensile strength (333.23 MPa) compared to a gap width of 0.10 mm (283.09 MPa). All specimens failed at the joint, exhibiting a brittle failure pattern (with Fp/Fm ratio ranging from 0.539 to 0.997).
Analisis Coefficient of Performance (COP) Sistem Refrigerasi R404a pada Cold Storage di Ramayana Plaza Andalas Padang Darus Samin; Risal Abu; Mukhnizar Mukhnizar
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64629

Abstract

Cold storage is a low-temperature storage facility that plays a crucial role in maintaining product quality within the food industry and modern commerce. The refrigeration system in this facility utilizes R404A refrigerant, a replacement for the original R22 refrigerant; yet, to date, no specific study has been conducted on the system's Coefficient of Performance (COP). Measurements and analysis indicate a refrigeration effect of 100.2 kJ/kg and a compressor work input of 65.5 kJ/kg. Although the COP value suggests that the system is capable of performing its cooling function effectively (maintaining a temperature of −20 °C), it is not yet operating optimally. An analysis of operational parameters shows that the superheat on the suction side (9.1 °C) and the evaporator air temperature differential (4.8 °C) remain within the normal range. However, a subcooling value in the liquid line approaching 0 °C suggests that the refrigerant retrofit process—from R22 to R404A—has not been fully optimized, particularly regarding the refrigerant charge quantity and the compatibility of the lubricating oil. This is believed to be one of the factors contributing to the system's suboptimal COP.
Analisis Keandalan Sistem Electronic Interlocking di Resor Sinyal 2.6 Kiaracondong Menggunakan FMEA dan FTA Dhina Setyo Oktaria; Arief Darmawan; Daniel Septian Wisdiawan
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64659

Abstract

The Electronic Interlocking (EI) system is vital for train safety on high-density lines such as the Daop 2 Bandung area. This study analyses the reliability and availability of the EI system, identifies critical components, and formulates maintenance strategies. Failure Mode and Effects Analysis (FMEA) with Pareto and severity-based prioritisation, Fault Tree Analysis (FTA), and Reliability-Availability-Maintainability (RAM) calculations were applied to 29 failure events recorded in 2023–2024 at the Kiaracondong 2.6 Signalling and Telecommunication Resort. The axle counter had the most failures (14 events). The priority failure modes were false red track sections due to axle counter counting errors (RPN 252), point machines failing to reverse or flickering (240), and interlocking module faults (216), plus two severity-9 modes prioritised for their safety impact. The system has an MTBF of 494.9 hours, an MTTR of 2.49 hours, and an availability of 99.50%, below the 99.9% target for vital signalling; 90% reliability lasts only about 52 hours.
Analisis Variasi Kuat Arus terhadap Kekuatan Uji Tarik Pengelasan SMAW pada Pelat Baja Karbon Rendah AISI 1020 Tri Yuli Padrji; Risal Abu; Azmil Azman
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64681

Abstract

Welding is a joining method in which the quality of the weld joint is influenced by a specific heat input. Electric current determines the depth of penetration as well as the microstructure within the heat-affected zone (HAZ). This study aims to analyze the effect of varying welding currents 90 A, 110 A, and 130 A on the tensile strength ( of AISI 1020 steel joints. The test results show tensile strength ( values ​​of 304.91 N/mm² at 90 A, 341.47 N/mm² at 110 A, and 311.97 N/mm² at 130 A. The corresponding yield strength ( ) values ​​are 213.55 N/mm², 239.04 N/mm², and 218.40 N/mm², while the strain (ε) values ​​are 6.00%, 6.53%, and 4.00%, respectively. It can be concluded that a current of 110 A is the optimal parameter for achieving maximum tensile strength. Using a current of 90 A results in incomplete penetration, whereas a current of 130 A leads to excessive heat input, which widens the heat-affected zone and degrades the material's mechanical properties due to coarse grain growth.
Analisis Kerusakan Kompresor HVAC untuk Tindakan Perawatan di PT. Supreme Energy Muara Labuh Egi Candra Adrial; Risal Abu; Mukhnizar Mukhnizar
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64721

Abstract

An HVAC system serves not only to regulate room temperature but also to maintain air quality, humidity, and the overall comfort and safety of the work environment. The reliability of an HVAC system depends on the performance of its key components. However, inadequate maintenance can lead to minor issues that may eventually escalate into serious problems. This study aims to analyze the failures that occur, evaluate the current maintenance system, and propose an improved maintenance approach. Based on an analysis using the Failure Mode and Effects Analysis (FMEA) method, five potential failures in an HVAC compressor were identified: low suction pressure, high discharge pressure, refrigerant leakage, expansion valve failure, and compressor overheating. The calculated Risk Priority Number (RPN) values ​​are as follows: high discharge pressure (216), compressor overheating (200), low suction pressure (192), refrigerant leakage (160), and expansion valve failure (140).