cover
Contact Name
sulistiyanto
Contact Email
yantog98@gmail.com
Phone
+6281332986888
Journal Mail Official
jeecom@unuja.ac.id
Editorial Address
https://ejournal.unuja.ac.id/index.php/jeecom/about/editorialTeam
Location
Kab. probolinggo,
Jawa timur
INDONESIA
Journal of Electrical Engineering and Computer (JEECOM)
ISSN : 27150410     EISSN : 27156427     DOI : -
Journal of Electrical Engineering and Computer (JEECOM) is published by Engineering Faculty of Nurul Jadid University, Probolinggo, East Java, Indonesia. This journal encompasses research articles, original research report, : 1) Power Systems, 2) Signal, System, and Electronics, 3) Communication Systems, 4) Information Technology, etc.
Articles 289 Documents
Real-Time Packaging Quality Inspection and Sorting Using YOLOv8 and ESP32-Based IoT Integration Saputra, Muhammad Arya; Aziz, As'ad Shidqy
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17208

Abstract

Manual product inspection and sorting in small and medium-sized enterprises (SMEs) are often slow and error-prone, whereas conventional computer vision systems require expensive infrastructure. This study proposes a low-cost, real-time packaging inspection and sorting system utilizing YOLOv8 integrated with an ESP32 microcontroller. The proposed closed-loop architecture combines object detection, servo-based actuation, and dual data logging via LCD, Blynk IoT, and Google Sheets, alongside end-to-end latency characterization. The dataset used consists of 1,510 packaging images annotated into two classes: Good Product and Damaged Product. Five dataset-splitting scenarios were evaluated using the early stopping method, with performance assessed based on precision, recall, mAP50, and mAP50-95 metrics. The optimal configuration achieved 99.32% accuracy and an mAP50 of 97.6%, with zero false negatives across 292 test samples. The measured response time was approximately 0.51 seconds, providing a real-time margin of 1.40 seconds at a conveyor speed of 30 RPM. Physical sorting achieved success rates of 86% for Damaged Products and 96% for Good Products, while data logging achieved 100% transmission success. These findings demonstrate that the YOLOv8–ESP32–IoT integration is a viable solution for low-cost, real-time packaging inspection and sorting, although mechanical factors remain crucial and further validation at an industrial scale is required.
Optimization of Operating Patterns Using Particle Swarm Optimization for a 3 × 93 MW Combined Cycle Power Plant Burhanuddin, Burhanuddin; Haddin, Muhamad
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17058

Abstract

Changes in electricity demand can result in frequent variations in generator loading patterns, which may increase natural gas consumption and power generation costs. Therefore, an optimal loading pattern is required to achieve efficient operation of generating units while maintaining the required power output. An appropriate load distribution among generating units is important to ensure that the available generating capacity can be utilized efficiently and economically. This study investigates the optimization of the operating pattern of a 3 × 93 MW Combined Cycle Power Plant (CCPP) at Tambak Lorok, Semarang, with the objective of improving gas fuel utilization and reducing power generation costs. The parameters considered include load pattern, gas fuel consumption, and generator output power. The Particle Swarm Optimization (PSO) method was applied to determine the optimal combination of generating-unit loading, and the optimization process was implemented using MATLAB R2021a. The proposed optimization approach is expected to provide a more efficient loading strategy that can support economical and reliable power plant operation. The results show that PSO can effectively optimize the loading pattern of the 3 × 93 MW Tambak Lorok CCPP. The average gas fuel consumption decreased from 1,061.78 MMBTU/h under the conventional operating pattern to 1,032.56 MMBTU/h after PSO optimization, resulting in a fuel saving of 29.22 MMBTU/h. Based on a natural gas price of Rp118,000/MMBTU, the optimization resulted in estimated operational cost savings of Rp3,448,032.75/h, equivalent to approximately Rp82,752,786/day and Rp29.79 billion/year. These results demonstrate that PSO can improve the economic efficiency of CCPP operation by optimizing the distribution of load among generating units. Thus, the application of PSO has potential as a decision-support approach for improving fuel efficiency and reducing operational costs in CCPP operation.
Analysis of Arcing Horn on Disk Insulator Configuration in 150 kV SUTT at PT PLN (Persero) Unit Induk Pembangunan Sumatera Bagian Tengah Monice, Monice; Satria, Tiaz Putra; Arlenny, Arlenny
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17183

Abstract

The reliability of the electric power transmission system on 150 kV High Voltage Overhead Transmission Lines (SUTT) is strongly influenced by insulation coordination, particularly in the disk insulator string and arcing horn assembly, which functions to divert electrical flashover caused by overvoltage so that the insulator is not damaged. Under the existing condition, it was found that the installed arcing horn was designed for a 12-disk insulator configuration, while the actual string used only 10 disk insulators, thereby changing the distance between the arcing horns and affecting its breakdown voltage. This study aims to analyze the effect of changes in disk insulator configuration on the arcing horn breakdown voltage and to evaluate the potential risk of insulation unreliability resulting from this mismatch. The research method involves technical data collection of the insulator string and arcing horn configuration, calculation of Critical Flashover Voltage (CFO) using the rod-plane gap method based on CIGRE recommendations, visualized through COMSOL Multiphysics 5.5 simulation. The results show that the 12-disk insulator configuration has an arcing horn distance of 1.352 m with a breakdown voltage of 709.8 kV (positive) and 1209.219 kV (negative), while the 10-disk insulator configuration has a distance of 1.060 m with a breakdown voltage of 556.5 kV (positive) and 995.333 kV (negative). Nevertheless, both configurations still satisfy the insulation coordination principle because the arcing horn breakdown voltage remains lower than the insulator breakdown voltage, with an insulation margin to BIL of 108% (12 disks) and 73.3% (10 disks). The smaller the gap distance, the higher the potential for flashover and the risk of system unreliability, so adjustment of the arcing horn distance is still recommended.
Evaluation of Email Communication Security Using OpenPGP-Based End-to-End Encryption on Mozilla Thunderbird Putra, Bagus Setya; Yunitasari, Siska; Larasati, Suci; Gunawan, Fani Indra; Ardhianto, Eka; Supriyanto, Aji
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 1 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i1.16094

Abstract

Email remains a primary communication channel across academic, professional, governmental, and personal domains. Despite its widespread adoption, conventional email infrastructure continues to exhibit fundamental security vulnerabilities, including susceptibility to phishing attacks, unauthorized message interception, identity spoofing, and unintended data disclosure. Although Transport Layer Security (TLS) has become the de facto standard for securing email transmission between clients and servers, its protection is confined to the transport layer and does not extend to message content stored on mail servers or processed by third-party providers. This study presents an empirical evaluation of OpenPGP-based end-to-end encryption implemented through Mozilla Thunderbird as a mechanism to address the limitations of transport-layer-only security. The research employs a comparative experimental design, contrasting standard TLS-only communication against OpenPGP-encrypted communication across multiple message size scenarios using packet-level analysis via Wireshark. Evaluation parameters encompass confidentiality, message integrity, sender authentication, payload visibility in TCP stream analysis, and transmission overhead across varied email payloads. The results demonstrate that while TLS-only communication still exposes identifiable SMTP metadata during packet inspection, OpenPGP transforms email content into high-entropy ASCII-armored ciphertext that resists direct interpretation even under deep packet inspection. Furthermore, cryptographic digital signatures successfully verified sender identity and ensured message integrity across all tested scenarios. Although OpenPGP introduces measurable transmission overhead averaging approximately 117% depending on message size, the security benefits substantially outweigh this trade-off. These findings establish OpenPGP as a robust and practical solution for enhancing end-to-end email security in modern communication environments.
Predicting Sleep Quality Using Hybrid Stacking Ensemble Of Random Forest And Catboost With Shap Interpretability Hakim, Baitullah; Faisal, Muhammad; Imamudin, Mochamad
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17445

Abstract

Sleep quality is an important indicator of physical and mental well-being, yet its prediction from lifestyle variables remains challenging because behavioral and physiological factors interact nonlinearly. This study develops a hybrid stacking ensemble that combines Random Forest and CatBoost as base learners and Logistic Regression as the meta-classifier for three-class sleep-quality prediction (Poor, Moderate, Good). The Sleep Health and Lifestyle Dataset contains 374 records, of which only 109 are unique, and is preprocessed through blood-pressure decomposition, derived-feature construction, categorical encoding, and numerical standardization. Models are evaluated with Accuracy, Precision, Recall, F1-Score, and multiclass ROC-AUC under Stratified 10-Fold Cross Validation, both in its standard form and in a duplicate-aware form in which identical records are kept in the same fold. Under the duplicate-aware protocol, Random Forest achieved 97.86% Accuracy, 91.06% macro F1-Score, and 0.9970 ROC-AUC; CatBoost achieved 97.33%, 90.70%, and 0.9930; and Hybrid Stacking achieved 97.06%, 90.51%, and 0.9784. Recall for the minority Poor class (n = 12) was 66.7% for all three models, and stacking did not improve on its base learners. SHAP analysis identifies Stress Level and Sleep Duration as the two dominant features. The results are specific to this small, largely duplicated dataset and do not support clinical use.
Design and Construction of an IoT-Based Three-Phase Electric Motor Monitoring and Protection Device Rabbani, Arya Rambu; Diantari, Retno Aita
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.16977

Abstract

Three-phase induction motors are widely used in industry as the main drive for pumps, compressors, and conveyors, yet they remain vulnerable to overcurrent, voltage unbalance, and overheating that can shorten their service life. Conventional protection devices such as thermal overload relays and circuit breakers operate locally and do not provide real-time condition information to operators. This study designs and builds an Internet of Things (IoT)-based monitoring and protection device for three-phase electric motors that can observe motor conditions in real time and respond automatically to disturbances. The hardware uses an ESP32 S3 microcontroller, three PZEM-004T sensors to measure voltage, current, power, frequency and power factor, and three MLX90614 non-contact infrared sensors to measure motor temperature. Protection is executed through a solid-state relay coupled to a contactor, while monitoring data are displayed locally on a 3.5-inch TFT screen and remotely through the Blynk IoT platform and Telegram notifications. Testing shows that the prototype trips automatically when the current exceeds the setting value and when the voltage deviation between phases exceeds 2%, with an average trip response time of 354.4 ms, while normal operating conditions do not trigger false trips. Comparison against a standard measuring instrument shows a maximum measurement error of 1.67%. These results indicate that the proposed system is accurate, responsive, and suitable for improving the safety and reliability of three-phase motor operation.
Universal Metadata Dictionary: A Platform-Agnostic Metadata Representation Model for Cross-RDBMS Schema Drift Detection Permana, Putu Adi Guna; Sukarsa, I Made; Putra, I Ketut Gede Darma; Putra, I Made Suwija
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17145

Abstract

Enterprise information systems deployed in large-scale organisations commonly operate across heterogeneous Relational Database Management System (RDBMS) environments, where metadata heterogeneity between platforms prevents consistent automated schema drift detection. This paper proposes the Universal Metadata Dictionary (UMD), a platform-agnostic metadata representation model that normalises database schema metadata from six widely deployed RDBMS platforms—Oracle, Tibero, SQL Server, PostgreSQL, MySQL, and SQLite—into a unified 29-element relational structure. The UMD is governed by four design principles—platform independence, completeness, normalisation, and hashability—implemented through a five-stage pipeline: extraction, parsing, mapping, enrichment, and storage. A structured data type normalisation mapping across seven canonical categories eliminates false drift reports arising from platform-specific type nomenclature. Validated through expert review by 13 domain practitioners using a five-point Likert scale (composite mean scores: 4.52–4.70 out of 5) and structural completeness assessment confirming all 29 elements are extractable from standard JDBC and system catalogue access on all six platforms. A suite of 15 structured test scenarios defines the empirical evaluation plan spanning fault injection tests, performance benchmarks, and cross-platform type mapping validation. Three novelties distinguish the UMD from all existing approaches: (1) the first cross-RDBMS metadata normalisation model covering all six platforms simultaneously, including Tibero; (2) a per-object O(1) hash comparison mechanism enabling O(n) total Phase-1 change detection; and (3) a metadata model directly supporting AI-based Semantic Code-Schema Analysis.
A Local-First Course-Grounded Learning System Using Parent-Child Retrieval and Quantized Large Language Models Mahajaya, Nyoman Sarasuartha; Gede Aristana, I Dewa; Gede Oka Kessawa Adnyana, Anak Agung; Darma Kotama, I Nyoman; Ngurah Desnanjaya, I Gusti Made
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17200

Abstract

Conventional Learning Management Systems (LMSs) mainly provide fixed materials and predefined activities, while cloud-based generative artificial intelligence may require external data transmission and produce responses that are not aligned with lecturer-approved course materials. This paper presents a local-first, course-grounded learning system using structured document processing, parent-child Retrieval-Augmented Generation (RAG), semantic retrieval, and quantized Large Language Models (LLMs). The system provides cited conversational responses, source-scoped quiz generation, lecturer moderation, image annotation, and interaction-history recording. Five quantized 7B and 14B models were evaluated with 20 course-grounded questions. The 7B models reached 57.14-58.95 tokens/s using approximately 5 GB of VRAM, whereas Qwen3 14B achieved the highest Faithfulness and Answer Relevancy scores of 0.882 and 0.906. The results demonstrate a trade-off between local inference performance and course-grounded response quality.
Technical and Economic Feasibility of a Rooftop Solar Photovoltaic System at Bank Nagari Lubuk Gadang Branch Bandri, Sepannur; Anthony, Zuriman; Ismail, Fauzan; Warmi, Yusreni; Dewi, Arfita Yuana; Putra, Andi Muhammad Nur; Liliana, Liliana
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17293

Abstract

The increasing demand for electrical energy and operational costs encourage the use of renewable energy sources in commercial buildings. This study aims to analyze the technical and economic feasibility of implementing a photovoltaic system at PT Bank Nagari, Lubuk Gadang Branch, South Solok Regency. The study uses a quantitative approach with a technical-economic feasibility study design through an electrical load survey, analysis of installation area conditions, component design, simulation using HOMER, and investment evaluation with Net Present Value, Internal Rate of Return, and Payback Period. The results show energy consumption of 251,514 kWh per day on weekdays and 75,157 kWh per day on holidays, with a monthly consumption of 6,386,078 kWh. Based on these needs, a system with a capacity of 84 kWp is designed consisting of 210 modules with a power of 400 Wp, a battery bank with a capacity of 840 kWh, a 66 kW inverter, and 30 units of SCC MPPT. The HOMER simulation produced 105,442 kWh of electricity per year with excess electricity of 41,453 kWh per year or 39.3 percent. From the financial aspect, a positive NPV of Rp381,776,996, an IRR of 11.82 percent, and a payback period of 10.64 years were obtained. The results showed that the designed system has positive technical and economic prospects, but investment decisions still need to consider the company's MARR value, battery replacement costs, and the consistency of actual load data with simulation parameters. These findings indicate that the use of solar energy has the potential to support the reduction of electricity purchases from the grid, increase operational cost efficiency, and strengthen sustainable energy management strategies in commercial banking buildings effectively.
Understanding Adoption of PELNI Mobile: Effects of Barriers, Quality, Trust, and Value Sudradjad, Anggita Allaudia; Purwita, Anggraeni Widya
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17280

Abstract

The increasing number of PT PELNI passengers, reaching 5.15 million in 2025, has not been matched by a shift toward digital ticketing: PELNI Mobile is used by only about 10% of the national passenger base, indicating resistance among prospective users' adoption intention toward maritime mobile ticketing. This study examines effects of Usage Barrier, Risk Barrier, and Information Quality on Trust; Information Quality on Perceived Value; and Trust and Perceived Value on Adoption Intention, integrating Innovation Resistance Theory (IRT) with information quality dimensions to explain trust formation in early adoption of a historically conventional maritime service. Data were collected via purposive sampling from 281 national respondents who use PELNI's sea services, are aware of PELNI Mobile, but have not used it, analyzed using SEM-PLS 4. The model explains 62.7% of variance in Trust, 72.5% in Perceived Value, and 71.7% in Adoption Intention, with good predictive relevance (Q²predict > 0); six of seven hypotheses were supported. Information Quality was the strongest predictor of Trust (β = 0.688; p = 0.000), while Risk Barrier was a significant barrier (β = -0.239; p = 0.000), far more influential than Usage Barrier, which had no significant effect (β = -0.011; p = 0.852). Perceived Value was the most dominant predictor of Adoption Intention (β = 0.666; p = 0.000). These results show that in early digital maritime adoption, transaction-security concerns shape trust more than usability complexity, a novelty distinguishing this study from other transport-adoption research, with implications for IRT and PELNI's digital adoption efforts.