Studi Kelayakan Pengaman Input-Output Trafo Distribusi Fuse Cut Out (FCO) dan NH Fuse di Area Payakumbuh A Fahrezi, Irgi; Liliana, Liliana
MSI Transaction on Education Vol 2 No 4 (2021): MSI Transaction on Education
Publisher : Minangkabau Scholar Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.46574/mted.v2i4.66

Abstract

Pada penyalurkan energi listrik, gardu distribusi merupakan salah satu komponen utama. Pengaman yang tidak sesuai standar banyak ditemukan pada gardu distribusi, contoh nya penggunaan pengaman keluaran trafo step-down NH-Fuse melebihi batas standar yang ditentukan dan penggunaan FCO yang tidak sesuai dengan standar. Tujuan dari penulisan penelitian ini adalah mengetahui standar penggunaan pengaman Fuse Cut Out (FCO) dan NH Fuse pada PHB-TR dari sebuah gardu distribusi. Metode yang di gunakan adalah dengan melakukan perhitungan rating Fuse Cut Out (FCO) dan NH Fuse kemudian dibandingkan dengan data yang telah diperoleh lalu di analisis. Berdasarkan hasil perhitungan dan analisa ukuran Fuse Link pada trafo 25 KVA adalah 2A, pada trafo 50 KVA adalah 2A, pada trafo 100 KVA adalah 4A, dan pada trafo 160 KVA adalah 6A. Kemudian berdasarkan hasil perhitungan dan analisa ukuran NH Fuse pada trafo 25 KVA dengan 2 jurusan adalah 20A, pada trafo 50 KVA dengan 2 jurusan adalah 40A, pada trafo 100 KVA dengan 2 jurusan adalah 80A, pada trafo 160 KVA dengan 1 jurusan adalah 250A, dan pada trafo 160 KVA dengan 2 jurusan adalah 125A.
ANALISA RPN TERHADAP KEANDALAN PERALATAN PENGAMAN JARINGAN DISTRIBUSI DENGAN METODE FMEA PLN CABANG PEKANBARU RAYON PANAM Liliana Liliana
SITEKIN: Jurnal Sains, Teknologi dan Industri Vol 10, No 2 (2013): Juni 2013
Publisher : Fakultas Sains dan Teknologi Universitas Islam Negeri Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24014/sitekin.v10i2.545

Abstract

AbstrakPemerintah melalui Perusahaan Listrik Negara (PLN) selalu berusaha untuk memenuhi kebutuhan akan energi listrik yang andal dan berkelanjutan. Salah satunya dengan menjaga fungsi peralatan pengaman dalam pendistribusian listrik ke konsumen. Metode yang digunakan dalam penelitian ini adalah Failure Mode Effect Analisis (FMEA). Metode ini bertujuan mengetahui tingkat resiko peralatan yang mengalami  gangguan yang dapat menyebabkan kegagalan pada sistem , metode meliputi  parameter severity (keparahan), occurrence (banyaknya kerusakan), dan dettection (pendeteksian) yang digunakan untuk menentukan Risk Potential Number (RPN) tiap peralatan pengaman. Hasil dari RPN tersebut dapat membuat urutan prioritas yang memposisikan cut out rusak sebagai resiko tertinggi dengan nilai 162, berikutnya MCB pembatas rusak dengan nilai RPN 112, dan  Rele Pelepas Beban Bekerja Karena Gangguan Station Service Pusat memiliki nilai resiko 56. Dengan melakukan prioritas penanganan yang tepat maka akan dapat memperkecil nilai RPN yang berpengaruh terhadap peningkatan keandalan sistem distribusi.
RANCANG BANGUN PAPAN SKOR OLAHRAGA BERBASIS MIKROKONTROLER ATMEGA 8535 DENGAN INPUTAN KEYBOARD KOMPUTER Liliana Liliana
SITEKIN: Jurnal Sains, Teknologi dan Industri Vol 11, No 1 (2013): Desember 2013
Publisher : Fakultas Sains dan Teknologi Universitas Islam Negeri Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24014/sitekin.v11i1.565

Abstract

Papan skor merupakan salah satu alat bantu dalam bidang olahraga untuk mengumumkan dan mencatat hasil suatu pertandingan sehingga para penonton dan atlit dapat mengetahui hasil skor pertandingan. Papan skor ini menggunakan mikrokontroler ATMega 8535 sebagai penyimpan dan proses program data kemudian ditampilkan kerangkaian seven segment, keyboard komputer sebagai input data agar memudahkan kita dalam penggunaan alat serta dapat di aplikasikan pada beberapa macam cabang olahraga seperti Volley, Sepak Takraw, futsal serta Bulutangkis. Papan skor ini juga dapat digunakan pada tempat olahraga yang semi permanen seperti disekolahan.
PENEMPATAN SVC (STATIC VAR COMPENSATOR) PADA JARINGAN DISTRIBUSI DENGAN ETAP 7.5.0 Liliana Liliana; Syahputra. I
SITEKIN: Jurnal Sains, Teknologi dan Industri Vol 12, No 1 (2014): Desember 2014
Publisher : Fakultas Sains dan Teknologi Universitas Islam Negeri Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24014/sitekin.v12i1.767

Abstract

Suatu  sistem  yang  baik  seharusnya  memiliki  nilai  tegangan  yang tidak  melebihi  batas  toleransi dengan kerugian daya yang minimal. Pada jaringan Distribusi tenaga listrik, aliran daya aktif dan    reaktif merupakan  parameter  yang  sangat  penting  dalam  meningkatkan  tegangan  sistem.  Daya  reaktif  yang berlebihan  dapat  mengakibatkan  menurunnya  faktor  daya  sehingga  mengakibatkan    kerugian  daya meningkat.  Penelitian ini menempatkan SVC  pada jaringan untuk menurunkan  daya reaktif tersebut.    Dari hasil  simulasi  yang  dijalankan  menggunakan  ETAP  7.5.0,  setelah  ditempatkannya  SVC  pada  jaringan menghasilkan  penurunan  rugi  daya  nyata  yang  mencapai  16,96%  dan  rugi  daya  reaktif  menurun  sebesar 22,32%.
Simulasi Dinamika dan Stabilitas Tegangan Sistem Tenaga Listrik dengan Menggunakan Power System Stabilizer (PSS) (Aplikasi Pada Sistem 11 Bus IEEE) Liliana Liliana
SITEKIN: Jurnal Sains, Teknologi dan Industri Vol 10, No 1 (2012): Desember 2012
Publisher : Fakultas Sains dan Teknologi Universitas Islam Negeri Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24014/sitekin.v10i1.572

Abstract

Untuk menjaga kestabilan sebuah sistem, maka perlu diupayakan mesin-mesin sinkron berada pada kondisi sinkronnya. Kestabilan sistem pada mesin sinkron dapat ditingkatkan dengan menggunakan perangkat kontrol PSS. Makalah ini membahas kestabilan tegangan saat unjuk kerja sistem dalam kondisi normal dan gangguan tanpa dan dengan peralatan kontrol tersebut. Studi kasus yang diambil adalah sistem 11 bus standar IEEE pada software EDSA (electrical Distribution and Transmision System Analysis) dan disimulasikan langsung. Dari hasil simulasi program menunjukkan penggunaan PSS yang digunakan pada sistem 11 bus tidak terlalu berpengaruh terhadap kestabilan dinamik walaupun unjuk perbaikan sistem sudah mulai meningkat dibandingkan sebelum pemasangan PSS, pengaruh yang paling besar dalam penggunaan PSS pada sistem 11 bus ini terdapat pada bus 01 saat kondisi normal besar arus 2616.44 A, setelah terjadi gangguan menjadi 8404.51 A, juga bus 05 mengalami kenaikan dari 128.42 A menjadi 377.77 A, dengan penggunaan PSS osilasi dapat diredam, pada bus 01 overshoot tegangan sebesar 1.1 PU dapat diredam pada settling time 9 detik pada tegangan 1 PU,dan pada bus 05 overshoot tegangan sebesar 9 PU dapat diredam pada settling time 9.8 detik pada tegangan 8.8 PU.
Reliability Improvement Using Sectionalizer with Section Technique Method liliana liliana; Zulfatri Aini; Hanif Naufal Qasthari
Seminar Nasional Teknologi Informasi Komunikasi dan Industri 2021: SNTIKI 13
Publisher : UIN Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Unreliability in the 20 kV distribution system at PT. PLN (Persero) Rayon Rumbai feeder Rusa is more caused by disturbances that occur. During 2020 this feeder was recorded to experience the highest disturbance of 83 times, causing the system to experience frequent blackouts. This study seeks to identify and improve the reliability of the system in the feeder. The reliability of the system can be calculated and analyzed in more detail with the Section Tehnique method. This method can identify reliability by breaking the system into several sections so that the reliability of each section can be known. The increase in reliability is done by adding a sectionalizer to a system that has low reliability, there are two scenarios that are carried out in placing this sectionalizer correctly to produce better reliability. The results of the calculation of the reliability of each section of the system using the Section Technique method have been obtained, the average value of each reliability index is SAIFI 11.231 (f/customer.yr), SAIDI 30.55 (hr/customer.yr), CAIDI 11.015 (hr/customer interruption). ). The results of this index calculation do not meet the standards of SPLN 68-2 1986 with SAIFI 3.2 (f/customer.yr) and SAIDI 21.9 (hr/customer.yr). The reliability improvement was carried out by implementing sectionilizer on the feeder and the reliability index was obtained with SAIFI values 9.8185 (f/customer.yr), SAIDI 27.5292 (hr/customer.yr) and CAIDI 11.223 (hr/customer interruption) with an increase in SAIFI percentage. by 10.4%, SAIDI 8.8% and CAIDI 0.37%. With the addition of a sectionilizer, it is very helpful in increasing reliability, although it still does not meet the expected standard values.Unreliability in the 20 kV distribution system at PT. PLN (Persero) Rayon Rumbai feeder Rusa is more caused by disturbances that occur. During 2020 this feeder was recorded to experience the highest disturbance of 83 times, causing the system to experience frequent blackouts. This study seeks to identify and improve the reliability of the system in the feeder. The reliability of the system can be calculated and analyzed in more detail with the Section Tehnique method. This method can identify reliability by breaking the system into several sections so that the reliability of each section can be known. The increase in reliability is done by adding a sectionalizer to a system that has low reliability, there are two scenarios that are carried out in placing this sectionalizer correctly to produce better reliability. The results of the calculation of the reliability of each section of the system using the Section Technique method have been obtained, the average value of each reliability index is SAIFI 11.231 (f/customer.yr), SAIDI 30.55 (hr/customer.yr), CAIDI 11.015 (hr/customer interruption). ). The results of this index calculation do not meet the standards of SPLN 68-2 1986 with SAIFI 3.2 (f/customer.yr) and SAIDI 21.9 (hr/customer.yr). The reliability improvement was carried out by implementing sectionilizer on the feeder and the reliability index was obtained with SAIFI values 9.8185 (f/customer.yr), SAIDI 27.5292 (hr/customer.yr) and CAIDI 11.223 (hr/customer interruption) with an increase in SAIFI percentage. by 10.4%, SAIDI 8.8% and CAIDI 0.37%. With the addition of a sectionilizer, it is very helpful in increasing reliability, although it still does not meet the expected standard values.
Analysis of Imbalance Loads and Losses Based on The Largest Loading by 3 Units of 3 Phase Distribution Transformer Zulfatri Aini; Esa Mutari; Liliana Liliana; Oriza Candra
JTEV (Jurnal Teknik Elektro dan Vokasional) Vol 7, No 1 (2021): JTEV (Jurnal Teknik Elektro dan Vokasional)
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (244.709 KB) | DOI: 10.24036/jtev.v7i1.111965

Abstract

The imbalance load of distribution transformers often occurs.This is due to the fact that the load time amongst consumers is not the same, so that there is a difference in the value for each R, S, and T phase. The value difference of the phase causes overload in several phases so as the current emerges in neutral transformers. The current flowing in the neutral transformers causes the losses. In this research, the identification of the overload and the calculation of the distribution transformer load with the IEC reference standard which is allowed for 80% and the calculation of the imbalance transformer load with the 5% standard, then the losses resulting from the presence of neutral currents were carried out. There are three transformers in the Hangtuah feeder that have a load exceeded the standard, namely the DRI 0157, DRI 0241, and DRI 0065 transformers. The calculations for the three transformers are taken from measurement data in the form of voltage and current values for each phase during the daytime and nighttime and are simulated using ETAP 12.6.0 software. The symmetrical component method was used to obtain the imbalance value of the transformer load based on the measurement results and the ETAP simulation. The result of this research is the imbalance load occured in the three transformers. DRI 0241 is the transformer that has the largest percentage of an imbalance load at night. At nighttime, based on the measurement results of the DRI 0241, the transformer load is 80% and 65% at daytime, while for the imbalance load at nighttime and daytime are 32.2% and 29.8%, respectively. The greater the loading of the transformer, the larger the imbalance loading of transformer becomes. The current in neutral transformer generated losses in the amount of 45 A and 2.4% at nighttime while for 33 A and 1.2% at daytime. The neutral current affects the values of losses that the higher it is, the bigger the losses appear in a transformer.
Pengaruh Pertambahan Beban Jangka Panjang Terhadap Penyettingan Fuse Cut Out dan Nieder Spannung Hoch Leistung Fuse (Studi Kasus GD-200 Kota Payakumbuh) Irgi A Fahrezi; Liliana Liliana
Seminar Nasional Teknologi Informasi Komunikasi dan Industri 2022: SNTIKI 14
Publisher : UIN Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Gardu distribusi merupakan salah satu komponen yang terpenting dalam menyalurkan energi listrik. Terdapat perangkat proteksi pada gardu distribusi, ditemukannya perangkat proteksi Fuse Link yang terdapat pada Fuse Cut Out (FCO) tidak semestinya dan NH Fuse yang melebihi standar yang sudah ditetapkan. Penelitian ini bertujuan menganalisis nilai pembebanan pada transformator distribusi GD-200 di tahun 2022 dan menganalisis nilai resetting pada pengaman transformator Fuse Cut Out (FCO) dan NH Fuse. Jenis pada penelitian ini adalah penelitian kuantitatif dengan menggunakan metode deskriptif. Peramalan dengan menggunakan metode Time Series dengan trend Quadratic, kemudian dilakukan perhitungan untuk menentukan kapasitas trafo di tahun 2022 hingga akhirnya melakukan perhitungan resetting FCO dan NH Fuse. Berdasarkan hasil penelitian didapatkan hasil ramalan beban GD-200 tahun 2022 dalam satuan kVA pada bulan Januari-Desember berturut-turut 137,639 138,301 138,965 139,633 140,303 140,976 141,652 142,331 143,013 143,697 144,384 145,075 resetting FCO menjadi 8 A, dan NH Fuse menjadi 125 A.
Pengaruh Temperatur dan Nilai Berat Jenis Cairan Elektrolit Terhadap Tegangan Sel Baterai Nickel Cadmium 110 Vdc Gardu Induk Perawang Sistem 150 kV Irvan Nurhadi Nurhadi; Liliana Liliana
CYCLOTRON Vol 5, No 2 (2022): CYCLOTRON
Publisher : Universitas Muhammadiyah Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (726.743 KB) | DOI: 10.30651/cl.v5i2.13501

Abstract

Pada suatu sel baterai mengandung elektrolit yang memiliki temperatur dan berat jenis tertentu dan dapat berubah sewaktu-waktu. Kinerja sel baterai dapat dipengaruhi oleh temperatur cairan elektrolit, yang mempengaruhi nilai berat jenis cairan elektrolit dan kemudian mempengaruhi tegangan keluaran yang dihasilkan sel baterai. Penelitian ini bertujuan untuk mengetahui nilai tegangan sel pada baterai Nickel Cadmium akibat pengaruh dari temperatur dan nilai berat jenis cairan elektrolit baterai di gardu induk Perawang setelah dilakukannya pengujian. Penelitian ini menerapkan metode regresi linier sederhana dengan bantuan software minitab guna mengetahui seberapa besar pengaruh temperatur dan nilai berat jenis cairan elektrolit pada baterai terhadap tegangan tiap sel pada baterai Nickel Cadmium di gardu induk Perawang. Hasil penelitian menunjukkan bahwa tegangan sel baterai yang dihasilkan sebesar 1,400 V hingga 1,483 V ketika temperatur dan nilai berat jenis elektrolit sebesar 27°C dan 1,23 gr/cm3. Sebaliknya, saat tegangan keluaran yang dihasilkan baterai sebesar 1,381 V hingga 1,397 V ketika temperatur dan nilai berat jenis elektrolit sebesar 28°C dan 1,21 gr/cm3. Hasil dari uji koefisien determinasi diperoleh bahwa besar pengaruh temperatur elektrolit terhadap tegangan keluaran sel adalah sebesar 44,22% dan besar pengaruh berat jenis cairan elektrolit terhadap tegangan keluaran sel sebesar 36,72%.
SIMULASI PERANCANGAN SISTEM PEMBANGKIT LISTRIK TENAGA SURYA ON-GRID PADA BARBERSHOP GAUL DENGAN MENGGUNAKAN HELIOSCOPE : Desain Sistem PLTS On-Grid pada Barbershop Gaul dengan menggunakan Helioscope Vito Arnando
Indonesian Journal of Electrical Engineering and Renewable Energy (IJEERE) Vol 3 No 1 (2023): IJEERE Juni 2023
Publisher : Institut Riset dan Publikasi Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57152/ijeere.v3i1.528

Abstract

Indonesia is a tropical country where Indonesia has summer with an average radiation of 4.5 kwh/m2 per day. Based on this, Indonesia is classified as a country that has abundant potential for solar energy so that the most suitable and most efficient generator to use is a solar power plant. Barbershop Gaul is a building that is used as a pilot for the object of research in this project. This building has high electricity consumption so that the difference between income and expenses for electricity consumption is often a deficit. The amount of electricity consumption is contributed by several existing electronic equipment including shaving machines, air conditioners, water pumps and so on. To overcome this problem, this project aims to produce a PLTS system design using a simulation method using the helioscope application. In addition to producing a system design, this project further produces an overview of the monthly PLTS energy production, a summary of the system, power loss sources to its economic analysis including initial investment costs, payback period and potential profits that can be obtained. After carrying out this project, it was concluded that the On-Grid PLTS at Barbershop Gaul produces 1,243.8 kWh of electrical energy annually with an energy consumption of 2,662 kWh/year. Thus if a PLTS is installed, the electrical energy used from the PLTS is 1,243.8 kWh and the remaining 1,418.2 kWh is supplied by PLN so Barbershop Gaul needs to pay IDR 3,600,000 to PLN for electricity consumption. However, with the savings generated by implementing the ON-grid system, the business owner only pays Rp. 1,682,593/year. For the initial investment issued in the installation of PLTS, it is Rp. 19,094,480 with Return Of Investment 11.3 Years or 11 Years 3 months