cover
Contact Name
Rudi Kurnianto
Contact Email
rudi.kurnianto@ee.untan.ac.id
Phone
+6285252665807
Journal Mail Official
j3eit@untan.ac.id
Editorial Address
Jl. Prof. Dr. Hadari Nawawi, Pontianak 78124, Indonesia
Location
Kota pontianak,
Kalimantan barat
INDONESIA
Journal of Electrical Engineering, Energy, and Information Technology
ISSN : -     EISSN : 30261856     DOI : http://dx.doi.org/10.26418/j3eit.v11i2
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) (E-ISSN: 3026-1856) is the latest name for the JTE UNTAN, which underwent a name change. This journal has been in circulation within UNTAN since 2013 under its previous name. The name change reflects an evolution in the topics covered by the journal, encompassing the fields of electrical engineering, energy, and information technology. With the establishment of J3EIT, it is expected to become a significant resource for the academic and research community in this discipline, fostering the exchange of knowledge and innovation among professionals in the field of electrical engineering and related areas. By consistently publishing high-quality scientific papers, this journal is expected to play a vital role in advancing knowledge in its field. J3EIT is published three times a year, April, August and December.
Articles 513 Documents
STUDI KOMPARATIF PATHLOSS PADA MODEL WALFISCH IKEGAMI MENGUNAKAN METODE DRIVE TEST DENGAN WALK TEST Hari Haryani; Fitri Imansyah; Jannus Marpaung
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 8, No 2: Juli 2020
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v8i2.43564

Abstract

Pathloss merupakan salah satu komponen perencanaan jaringan telkomunikasi yang harus diperhitungkan dengan baik, dimana analisis pathloss ini membantu memprediksi seberapa buruk redaman yang terjadi pada daerah tersebut, dalam perhitungan pathloss diperlukan pemilihan beberapa model propagasi yang sesuai dengan cluster dari perencanaan jaringan telekomunikasi tersebut, Pada penelitian ini dilakukan dikota Ketapang dan menggunakan model propagasi Walfisch Ikegami. Untuk mengetahui kualitas jaringan diperlukan metode pengukuran didaerah tersebut, untuk metode pengukuran menggunakan metode drive test dan walk test. Dimana kedua metode pengukuran ini akan digunakan pada 5 titik tempat penelitan dalam dua kondisi yang berbeda yaitu pada saat kondisi jam sibuk (18.00-22.00) dan jam tidak sibuk (01.00-06.00). Hasil pada penelitian ini, perhitungan model Walfisch Ikegami diperoleh nilai level daya terima (RSRP) sebesar -78.2 dBm dijalan Kutilang, -87.44 dBm dijalan Agus Salim, -91.19 dBm dijalan Manggis, -92.26 dBm dijalan M.T. Haryono dan -92.73 dBm dijalan H. Jahari. Untuk hasil pengukuran dari metode drive test diperoleh nilai RSRP untuk jam sibuk dan jam tidak sibuk sebesar -82 dBm dan -75 dBm dijalan Kutilang, -80 dBm dan -81 dBm dijalan Agus Salim, -76 dBm dan -80 dBm dijalan Manggis, -86 dBm dan -89 dBm dijalan M.T. Haryono dan -82 dBm dan 80 dBm dijalan H. Jahari. Sedangkan hasil pengukuran dari metode walk test diperoleh nilai RSRP untuk jam sibuk dan jam tidak sibuk sebesar -88 dBm dan -84 dBm dijalan Kutilang, -77 dBm dan -79 dBm dijalan Agus Salim, -77 dBm dan -81 dBm dijalan Manggis, -88 dBm dan -87 dBm dijalan M.T. Haryono dan -81 dBm dan 81 dBm dijalan H. Jahari. Selisih nilai di pengaruhi oleh faktor-faktor yang berada pada lokasi penelitian, seperti jarak BTS Rooftop ke MS, lebar jalan, tinggi gedung, jarak antar gedung, kecepatan waktu pengukuran dan faktor kepadatan pengguna jaringan internet.
PENJADWALAN EKONOMIS PADA UNIT-UNIT PEMBANGKIT THERMAL DENGAN MENGGUNAKAN METODE GRAVITATIONAL SEARCH ALGORITHM Aprianto Alhamdani .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 7, No 2: Juli 2019
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v7i2.33618

Abstract

In a generation, a generator can serve a load with a certain power value, so what needs to be considered is how much power must be generated by each generating unit, so that the optimum power generation and economical fuel costs are obtained or commonly called the Economic Dispatch (ED). Several methods such as conventional methods have been carried out in solving Economic Dispatch problems such as the Lagrange, Linear Programming and Quadratic Programming methods. In a problem such as economic dispatch, researchers using gravitational Search Algorithm methods, (GSA) is one of the modern methods applied based on the laws of gravity. In the ED representation the GSA method finds optimum values of optimally generated power as a reference for the lowest fuel cost ($ / h) as the best mass with the smallest distance. To test the Gravitational Search Algorithm method, it is tested with several different parameters from the IEEE standard system on 3 generator units with 6 generator units and 20 generator units. To test the effectiveness of the Gravitational Search Algorithm method, the results are compared with conventional methods, namely the Lagrange Multiplier method. One of the results of the test is the unit 3 generator test system with losses of transmission on the load test 125 MW with the GSA method having a more economical price than the LM method of ± 0.185%, in testing a load of 225 MW taking into account transmission loss, GSA method more economical than the LM method of ± 0.124%. Furthermore, transmission losses at the time of the test load 225 MW with the GSA method amounting to ± 2.52% of the power generated by calculating the transmission loss means that the total power to be generated is 230.8119 MW. While the LM method is ± 2.64% with a total power generation of 231,101 MW. The factors that affect the results of the GSA method optimization test are Mass Agent (N), alpha, G0, and Maximum Iteration Number. In this case the gravitational search algorithm method is one of the modern methods that can be used in economic dispatch problems because it has succeeded in completing the achievement of optimum prices for generating economic fuel costs with the accuracy of the results obtained optimally.
ANALIS PREDIKSI PENERIMAAN LEVEL SINYAL PADA DAERAH SUB URBAN TERHADAP UNJUK KERJA JARINGAN GSM Muhammad Mudjiono .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.18903

Abstract

Sub-urban area is a suburban area (rural) with some of the barriers of trees, houses and buildings that are not too high under 5 level. Some of the causes of interruption of the call is limited channel reception level talks and the problem of RF signals (radio frequency) where the quality of the signal level is strongly influenced by local conditions damping propagation. The study was conducted in village siduk, districtsnanga tayap, north kayong district, Problems GSM network performance can be seen from the monitoring of traffic through NetAct software by using parameter-parameter above as: SDCCH Blocking, SDCCH Drop, Loss RF SDCCH, TCH Blocking, TCH Drop, and TCH RF Loss. Then do the calculation Prediction Reception signal level using Okomura-Hatta. Manual calculation results in BTS North Kayong siduk shows that the BTS antenna sector 1 with a power 27 W is obtained within a range of 3.2 km with a reception signal level -80 dBm, while the range desired by PT. Telkomsel is 3.5 Km, then power must be increased to 34.62 W. In sector 2, the transmit power of 27 W, within a range of 3.2 km, with the reception signal level -80 dBm, the desired range of 3.8 Km, power must be increased to 35.80 W. in the third sector, the transmit power of 26 W, within a range of 3.1 km, with the reception signal level -80 dBm, the desired range 3.5 Km, power should rise to 34.26 W. from the results of calculations can be concluded that the performance of the BTS antennas siduk north Kayong less than the maximum because of the decreasing transmission power due to the loss of damping propagation in sub urban Reviewed sector antenna 1 is (2 dBm), sector 2 is (3 dBm), sector 3 is (3 dBm). But in general is still quite good. Key word : Sub- urban , NETACT , Traffic , Okomura – Hatta.
PEMETAAN COVERAGE AREA BASE TRANSCEIVER STATION (BTS) DI KECAMATAN HULU GURUNG KABUPATEN KAPUAS HULU KALIMANTAN BARAT MENGGUNAKAN SOFTWARE ARCMAP Pratama, Aditya Cahya; Pontia W, F. Trias; Ade Putra, Leonardus Sandy; Imansyah, Fitri; Tjahjamooniarsih, Neilcy
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 10, No 2: Juli 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v10i2.56176

Abstract

Base Tranceiver Station merupakan perangkat pemancar (Transceiver) dan penerima (Receiver) yang memberikan pelayanan radio kepada Mobile Station (MS). Setiap BTS melayani sebuah sel. Dalam daerah layanan tersebut, pelanggan dapat bergerak secara bebas sambil berkomunikasi tanpa terjadinya pemutusan hubungan komunikasi. Dalam permodelannya, sel biasanya digambarkan dalam bentuk heksagonal (atau bentuk lain) untuk mempermudah penggambaran pada layout perancanaan. Guna mengetahuai cakupan sebenarnya dari sebuah BTS, diperlukan penelitian pemetaan coverage area dengan mengambil nilai sudut tilting antena, ketinggian antena serta arah cakupan antena dari suatu BTS yang kemudian diolah menggunakan software ArcMap. Output penelitian berupa peta coverage area BTS Kecamatan Hulu Gurung Kabupaten Kapuas Hulu. Hasil penetian menunjukkan bahwa dari 15 desa yang ada, hanya 8 desa yang sudah terlayani jaringan telekomunikasi dan 7 sisanya merupakan blankspot area.
PEMETAAN MEDAN ELEKTROMAGNETIK PADA PEMUKIMAN PENDUDUK DI BAWAH JARINGAN SUTT 150 KV PLN WILAYAH KALIMANTAN BARAT Baharuddin .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 2, No 1: Januari 2014
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v2i1.5160

Abstract

Semakin tinggi tegangan transmisi semakin besar medan electromagnet yang ditimbulkan. Mengingat pentingnya hal ini, maka dilakukan pengukuran kuat medan elektromagnet dibawah saluran transmisi 150 kV dengan menggunakan EMF Survey Meter HI-3604. Harga ini menunjukkan bahwa kuat medan elektrik masih dibawah ambang batas yang distandarkan oleh WHO yaitu untuk medan listrik 5 kV/m dan untuk nilai medan magnet melebihi ambang batas yang di tetapkan oleh WHO yaitu 100 mT (80 mA/m).
ANALISIS KINERJA TRANSMISI MICROWAVE LINK END SITE PADA MONITORING MENGGUNAKAN IMASTER NCE Angga Kusuma Yuda; Fitri Imansyah; Dedy Suryadi; Jannus Marpaung; Redi Ratiandi Yacoub
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 9, No 1: Januari 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v9i1.44867

Abstract

Penelitian ini membahas bagaimana kinerja transmisi microwave link end site, pada hasil pengukuran terhadap parameter dari perencanaan link budget dan berdasarkan standar dari international telecommunication union (ITU), menggunakan website pengukuran sinyal iMaster NCE. Faktor-faktor yang dapat menurunkan atau melemahkan nilai RSL diantaranya, adanya obctacle, faktor meteorologis (cuaca), kondisi jarak, kesalahan konfigurasi jaringan, pergeseran sudut antena, dan kerusakan perangkat ODU serta peralatan terutama alat ukur. Website iMaster NCE digunakan untuk memonitoring nilai RSL suatu site dengan menggunakan site ID secara real time. Proses penelitian yang dilakukan adalah melakukan pengukuran nilai RSL pada 5 transmisi microwave link end site selama 3 kali perhari pada 15 hari pengukuran. Analisis kinerja dilakukan berdasarkan hasil pengukuran RSL pada monitoring terhadap parameter daya terima dari perencanaan link budget dan (ITU). Pada pengukuran nilai RSL transmisi microwave link  hanya 4 end site yang pernah mencapai nilai RSL sesuai pada perencanaan link budget dan yang tidak adalah site sepakat 4B. Penurunan nilai RSL terendah selama pengukuran diakibatkan oleh cuaca hujan. Berdasarkan parameter dari (ITU) penurunan nilai RSL selama pengukuran masih masuk kedalam kondisi sangat baik yaitu masih > -50 dBm, hal tersebut disebabkan oleh kondisi jarak antar site masih tergolong dekat yaitu kurang dari 1 Km sehingga redaman ruangan bebas yang dimiliki kecil, serta selama pengukuran berlangsung tidak terjadi kondisi-kondisi yang menyebabkan menurunnya nilai RSL kecuali hanya cuaca hujan yang menurunkan sedikit nilai RSL. Transmisi microwave link end site memiliki sedikit kelebihan yaitu sulit untuk terjadi pergeseran sudut antena dikarenakan diameter antena yang digunakan rata-rata kecil.
KESTABILAN DINAMIS SISTEM DOUBLE INVERTED PENDULUM DENGAN PERSAMAAN LAGRANGE Bhareszy, Rahel; Hadary, Ferry; -, Hilda
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 10, No 2: Juli 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v10i2.56794

Abstract

Double inverted pendulum adalah sistem yang nonlinear, tidak stabil dan reaksi sistem yang cepat. Sistem ini merupakan suatu modifikasi dari pendulum terbalik, yaitu dengan menambahkan satu batang pendulum lagi yang disambungkan di ujung batang pendulum sebelumnya. Berdasarkan tinjauan, banyak dari peneliti yang menggunakan Lagrange untuk model dinamis dari sistem. Pada jurnal ini juga menampilkan pembelajaran dari sistem dengan menggunakan metode Linear Quadratic Regulator (LQR). Persamaan Lagrange dapat diperoleh dengan meninjau energi kinetik dan energi potensial partikel tanpa perlu meninjau gaya yang beraksi pada partikel. Persamaan dinamis nonlinear dari sistem diperoleh menggunakan persamaan Lagrange.
ANALISIS UNJUK KERJA RADIO IP DALAM PENANGANAN JARINGAN AKSES MENGGUNAKAN PERANGKAT HARDWARE ALCATEL-LUCENT 9500 MICROWAVE PACKET RADIO (MPR) Syarifah Riny Rahmaniah Syarifah Riny Rahmaniah
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 2, No 2: Juli 2014
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v2i2.6416

Abstract

Tujuan mengevaluasi unjuk kerja Radio Ip dalam menangani jaringan akses dengan menggunakan perangkat hardware Alcatel-Lucent 9500 MPR adalah dapat membantu untuk mendapatkan jaringan akses yang tidak dapat dijangkau pada daerah sub urban seperti Rasau Jaya. Link budget adalah sebuah power budget yang merupakan salah satu elemen fundamental dari perencanaan system radio. Link budget adalah bagian dari perencanaan system RF, dimana semua kumpulan persoalan termasuk propogasi, Link budget harus menghitung semua gain dan loss yang akan dialami gelombang radio dari transmisi menuju receiver. Parameter-parameter link budget yaitu loss feeder, free space loss, gain antena dan  equivalent isotrop radiated power (EIRP). Dalam penelitian ini dilakukan analisis unjuk kerja Radio Ip dalam penanganan jaringan akses pada BTS Pontianak-Rasau Jaya untuk mendapatkan hasil daya terima sinyal (Pr) yang dilakukan dengan menggunakan Software Radio Ip yaitu aplikasi NetO yang merupakan aplikasi PT. Telkom, Tbk. Dari data hasil menggunakan aplikasi NetO bahwa daya terima (Pr) Pontianak-Rasau Jaya dari bulan Oktober-Januari yang memiliki daya terima paling baik yaitu pada tanggal 17 Januari 2014, -42,0 dBm, sedangkan daya terima (Pr) yang diperoleh dari perhitungan tanpa faktor K adalah -40,373 dBm dan dengan faktor K adalah -41,703. hasil yang diperoleh hanya berbeda -2,373 dBm. Berdasarkan tolok ukur untuk daya terima yang di gunakan mengacu pada standar International Telecommunication Union (ITU) yaitu Pr > - 50 dBm, maka sangat baik. Sehingga daya terima yang diperoleh dari hasil pengukuran dan perhitungan sangat baik. Jadi dapat disimpulkan bahwa hasil pengukuran nilainya masih memenuhi standar ITU dalam penanganan jaringan akses.   Kata kunci : Jaringan Akses, Nirkabel, Radio Ip, Aplikasi NetO, dan  Power Link Budget
Analisis Penerapan Penggunaan Wajan Bolic Dengan Antena Helix Dalam Memperkuat Sinyal WiFi Adrianus Umben; Ade Elbani; Jannus Marpaung
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 9, No 2: Juli 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v9i2.48235

Abstract

Sinyal internet di Batulayang di jalan Panca Bakti khususnya Panca Bhakti dalam Bukit Reel yang memiliki sinyal internetan yang rendah, jarak Tower Indosat, 3 (Tri) dan XL terdekat juga terbilang cukup jauh dari lokasi penelitian dan daerah Bukit rell tersebut masih dalam katagori banyak perpohonan sehingga dan dalam katagori daerah blankspot (sinyal lemah) khususnya, menggunakan kartu Indosat, 3 (Tri) dan XL. Hal ini menimbulkan permasalah bagi pengguna internet. Internet sangat di butuhkan pada berbagai kalangan khususnya pada kalangan siswa dan mahasiswa-mahasiswi dimana pada jaman ini virus covid-19 masih melanda sehingga proses ngajar-mengajar secara online dengan ini jaringan internet sangat di butuhkan pada daerah Bukit Reel dan sekitar menginggat jaringan di Bukit Reel khususnya pada layanan Indosat, 3 (Tri) dan XL tidak stabil bahkan terbilang sinyal lelet dengan adanya antena wajan Bolic dan antena Helix dapat menjadi solusi di daerah yang blankspot (sinyal lemah) agar masyarakat setempan dapat mengikuti  perkembangan proses ngajar-mengajar menggunakan internetan atau secara daring. Dalam penelitian dimana analisis dilakukan pada dua antena yang berbeda yaitu antena wajan Bolic dan antena Helix dengan tujuan yang sama yaitu memperkuat sinyal sinyal WiFi. Bedasarkan hasil pengujian kecepatan internet menggunakan aplikasi Speedtest dan aplikasi G-NetWiFi mendapatkan nilai kecepatan parameter terbaik menggunakan kartu Indosat dengan antena wajan Bolic di lokasi 1 signal strength -50 dBm, RSSI -8 dBm, jitter 32 ms, kecepatan download 2,84 Mbps dan kecepatan upload 2,29 Mbps sedangkan menggunakan antena Helix signal strength -50 dBm, RSSI -8 dBm, jitter 170 ms, kecepatan download 2,73 Mbps dan kecepatan upload 1,03 Mbps. Dengan kualitas sinyal yang baik maka dapat dilakukan aktifitas akses internet dan fitur-fiturnya seperti whatsapp, googel chrome dan youtube tanpa kendala.
EVALUASI SISTEM PENCAHAYAAN DI PERPUSTAKAAN UNTAN GEDUNG LAMA BERDASARKAN STANDAR PUIL 2011 Ricki Oktafianus M; Rudi Gianto; Purwoharjono -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 7, No 2: Juli 2019
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v7i2.35373

Abstract

Sistem penerangan pada suatu ruangan yang baik akan mempengaruhi hasil kerja dan kenyamanan bekerja seseorang. Sistem pencahayaan pada gedung lama Perpustakaan Untan perlu dilakukan evaluasi, agar mengetahui intensitas cahaya yang dibutuhkan pada ruangan. Pengukuran dilakukan pada 3 (tiga) periode waktu yaitu periode waktu pagi, periode pada siang hari dan periode pada malam hari serta metode yang digunakan untuk melakukan perhitungan dengan menggunakan metode lumen. Teknis pengukuran yang dilakukan pada setiap ruangan dengan menggunakan metode pengukuran setempat. Hasil pengukuran dengan menggunakan lux meter diperoleh ruangan yang memenuhi standar kuat penerangan pada pengukuran pagi diperoleh ruangan yang memenuhi standar kuat penerangan pada pagi hari yaitu R 11 sekitar 11,75 %, pada siang hari R 11 sekitar 11,75 %, sedangkan untuk malam hari tidak ada ruangan yang memenuhi standar yang sesuai dengan SNI 6197-2011. Kurangnya intensitas penerangan pada pagi dan siang hari dalam ruangan ini disebabkan karena pencahayaan alami yang masuk ke dalam ruangan terhalang oleh bangunan sekitar, sedangkan untuk malam hari faktor yang mempangaruhi adalah penentu jumlah lampu dan jenis lampu yang tidak tepat.

Page 6 of 52 | Total Record : 513