cover
Contact Name
Wesli
Contact Email
wesli@unimal.ac.id
Phone
+62811671918
Journal Mail Official
teras.jurnal@unimal.ac.id
Editorial Address
Civil Engineering Department, Universitas Malikussaleh,Main Campus of Universitas Malikussaleh Jl. Medan-Banda Aceh, Cot Tengku Nie, Reuleut, North Aceh District, Aceh, Indonesia Email: teras.jurnal@unimal.ac.id
Location
Kota lhokseumawe,
Aceh
INDONESIA
Jurnal Teknik Sipil
ISSN : 20880561     EISSN : 25021680     DOI : https://doi.org/10.29103/tj.v16i2.1360
Core Subject :
Focus and Scope Teras Jurnal - Jurnal Teknik Sipil is a journal that communicates the results of research within the scope of civil engineering and scientific development as well as aspects of practitioners. The process of manuscript submission is open throughout the year. All submitted manuscript will be screened with double-blind peer review and editorial review before they are accepted to publish. Teras Jurnal receives a manuscript from the following area below civil engineering science and development with the interdisciplinary and multidisciplinary approach: Building Materials and Structures Constructions Technology Constructions Economy and Management Earthquake Engineering Environmental Engineering Renovation of Buildings Geotechnical Engineering Highway Engineering Hydraulic and Hydraulic Structures Road and Bridge Engineering Structural Engineering Surveying and Geo-Spatial Engineering Transportation Engineering Tunnel Engineering Urban Engineering and Economy Water Resources Engineering Urban Drainage
Arjuna Subject : -
Articles 441 Documents
Kajian Kuat Tekan Beton Beragregat Halus Pasir Pantai Pasca Bakar Dengan Variasi Waktu Water Curing Syarifah Asria Nanda; maulani emi; Yovi Chandra
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 2 (2022): Volume 12 Nomor 2, September 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i2.671

Abstract

Abstrak Material beton salah satu bahan penyusunnya adalah pasir (agregat halus). Pasir pantai sebagai bahan penyusun beton menjadi pilihan oleh masyarakat pesisir. Kebakaran meninggalkan kekhawatiran akan struktur beton yang mengakibatkan penurunan terhadap kekuatan beton. Untuk menggembalikan kekuatan beton pasca bakar perlu dilakukan proses pemulihan. Penelitian menggunakan pasir pantai sebagai pengganti agregat halus pada beton yaitu mengetahui besar kuat tekan untuk beton beragregat pasir pantai pasca bakar dan metode waktu water curing. Penelitian dilakukan di Laboratorium dengan metode eksperimental. Benda uji dibuat 15 sampel berbentuk silinder dengan diameter 15 cm dan tinggi 30 cm. Pengujian kuat tekan beton dengan waktu 28 hari tanpa pembakaran, pasca bakar 350°C, dan pasca bakar 350°C dengan water curing pada umur 7, 14 dan 28 hari. Hasil pengujian kuat tekan untuk beton beragregat halus pasir pantai sebesar 17,90 Mpa dan pasca bakar 350°C sebesar 10.41 Mpa. Perlakuan beton pasca bakar 350°C beragregat halus pasir pantai dengan water curring umur 7,14 dan 28 hari berturut-turut adalah 12,20 Mpa, 13,69 Mpa, dan 14,89 Mpa. Pemulihan beton pasca bakar 350°C dengan water curing 28 hari menunjukkan kenaikan kuat tekan beton yang maksimal bahwa pengaruh perawatan (curing) pada beton pasca pembakaran sangat mempengaruhi pengembalian kuat tekan beton beragregat halus pasir pantai. Kata kunci: kuat tekan beton, pasca bakar, waktu water curing, pasir pantai.   Abstract One of the materials for making concrete is sand (fine aggregate). Beach sand as a material for making concrete is the choice of coastal communities. The fire left a concern for the concrete structure which resulted in a decrease in the strength of the concrete. To restore the strength of post-combustion concrete, it is necessary to carry out a recovery process. Research using beach sand as a substitute for fine aggregate in concrete is to determine the compressive strength for post-burnt aggregated beach sand and the method of water curing time. The research was conducted in a laboratory with an experimental method. The test specimens were made of 15 cylindrical samples with a diameter of 15 cm and a height of 30 cm. Testing the compressive strength of concrete with a time of 28 days without burning, post-burning 350°C, and post-burning 350°C with water curing at the age of 7, 14 and 28 days. The results of the compressive strength test for fine aggregated beach sand are 17.90 Mpa and post-burnt 350°C is 10.41 Mpa. The treatment of post-burned concrete at 350°C with fine aggregated beach sand with water curring at the age of 7.14 and 28 days, respectively, was 12.20 Mpa, 13.69 Mpa, and 14.89 Mpa. Recovery of post-burned concrete at 350°C with water curing 28 days showed an increase in the maximum compressive strength of concrete that the effect of curing on post-combustion concrete greatly affects the return of the compressive strength of fine-aggregated concrete on beach sand. Keywords: compressive strength of concrete, post burn, water curing time, beach sand.
Kajian Pengaruh Lubang Resapan Biopori (LRB) Terhadap Kapasitas Infiltrasi Pada Perumahan Kencana Damai Kota Palembang Febrinasti Alia
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.672

Abstract

Abstrak Permasalahan banjir di kawasan pemukiman padat penduduk merupakan permasalahan yang sering terjadi di wilayah perkotaan. Salah satu contohnya adalah banjir yang sering terjadi pada perumahan Kencana Damai yang terletak pada Kecamatan Sako, Kelurahan Sukamaju, Kota Palembang. Setiap musim penghujan, genangan atau banjir sering terjadi dengan durasi 2-3 jam. Penelitian ini digunakan untuk mengetahui kapasitas infiltrasi dan mengetahui seberapa besar efektivitas LRB dalam meningkatkan laju infiltrasi.  Dalam pembuatan lubang biopori, diberikan jarak 60 cm (50-100 cm) karena disesuaikan dengan luas lahan yang terbatas. Lubang yang dibuat memiliki kedalaman sekitar 1 m dengan diameter lubang sebesar 4 inch. Kemudian dimasukkan sampah daun kering, dan pengukuran laju infiltrasi dilakukan setelah sampah terdekomposisi selama 7 hari, 14 hari, dan 28 hari. Berdasarkan penelitian yang dilakukan, diketahui bahwa sifat fisik dan jenis tanah pada lokasi 1 dan 3 sama yaitu SW (pasir bergradasi baik), sedangkan pada lokasi 2 memiliki jenis tanah SP (pasir bergradasi jelek). Sifat fisik dan jenis tanah ini mempengaruhi kapasitas infiltrasi. Hal ini dibuktikan dengan kenaikan laju infiltrasi yang besar pada lokasi 1 dan 3 (SW) yaitu 15,588 cm/jam atau 57,86% dan 14,971 cm/jam atau 55,57%. Berbeda dengan laju infiltrasi lokasi 2 dengan jenis tanah SP (pasir bergradasi jelek), kenaikan laju infiltrasi pada lokasi tersebut hanya sebesar 4,435 cm/jam atau 16,46%. Kata kunci: karakteristik tanah, LRB, infiltrasi, ekodrainase  Abstract The problem of flooding in densely populated residential areas is a problem that often occurs in urban areas. One example is the frequent flooding of Kencana Damai housing estates located in Sako District, Sukamaju Village, Palembang City. Every rainy season, puddles or floods often occur with a duration of 2-3 hours. This study was used to determine the infiltration capacity and to find out how much effective LRB is in increasing the infiltration rate.. In making biopore holes, a distance of 60 cm (50-100 cm) is given because it is adapted to the limited land area. The hole made has a depth of about 1 m with a hole diameter of 4 inches. Then, dry leaf litter was added, and the infiltration rate was measured after the waste had decomposed for 7 days, 14 days, and 28 days. Based on the research conducted, it is known that the physical properties and soil types at locations 1 and 3 are the same, namely SW (good graded sand), while at location 2 the soil type is SP (poorly graded sand). These physical properties and soil types affect the infiltration capacity. This is evidenced by the large increase in the infiltration rate at locations 1 and 3 (SW), namely 15.588 cm/hour or 57.86% and 14.971 cm/hour or 55.57%. In contrast to the infiltration rate at location 2 with SP soil type (poorly graded sand), the increase in infiltration rate at that location was only 4.435 cm/hour or 16.46%. Keywords: soil characteristics, LRB, infiltration, ecodrainage
Aplikasi Teknologi Pemanenan Air Hujan (PAH) Sebagai Sumber Air Bersih di Pangkalan Pendaratan Ikan (PPI) Eldina Fatimah; Amir Fauzi; Azmeri Azmeri
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 2 (2022): Volume 12 Nomor 2, September 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i2.680

Abstract

Abstrak PPI di desa Meunasah Keudee kecamatan Mesjid Raya kabupaten Aceh Besar sejak pembangunannya tahun 2013 sampai saat ini belum tersedia fasilitas air bersih yang dibutuhkan nelayan saat pendaratan. Kebutuhan air untuk membersihkan diri (sanitasi), mencuci bagian dalam kapal, dan mencuci hasil tangkapan sulit diperoleh dan sangat minim. Akibat dari keterbatasan tersebut para nelayan harus membeli air bersih melalui depot penjualan yang datang khusus saat kapal mendarat. Hal ini tentu saja cukup memberatkan nelayan dan mengurangi hasil pendapatan mereka. Tujuan dari kegiatan ini adalah penyediaan air bersih dengan menerapkan teknologi tepat guna berupa pemanenan air hujan (PAH) dari atap salah satu bangunan PPI yang ada dan ditampung ke tandon air berkapasitas 1000l. Dari hasil diskusi dan musyawarah informal dengan Perangkat Desa disepakati, tidak hanya menggunakan talang air sebagai pemanen air hujan tetapi juga dilengkapi sumur dangkal. Sehingga kekurangan air bila musim kemarau dapat diatasi. Kata kunci: pemanenan air hujan (PAH), tandon air, sumur dangkal, teknologi tepat guna.  Abstract PPI located at Meunasah Keudee Village, Mesjid Raya District, Aceh Besar Regency, since its construction in 2013 has not yet provided clean water facilities needed by fishermen when their ships landing. The need of water for sanitation is difficult to obtain and quite scarce. As a result, they have to buy water that comes specifically when the ship lands. This of course is quite burdensome for fishermen and reduces their income. The purpose of this activity is the provision of clean water by applying appropriate technology in the form of rainwater harvesting (PAH) from the roof of one of the existing PPI buildings and accommodated into a water tank with a capacity of 1000l. After informal discussion with the Village Head and Panglima Laot, it was agreed that both gutters and shallow well are used to fillup the tank. Hence the lack of water during the dry season can be overcome. Keywords: rainwater harvesting (PAH), water tanndon, shallow wells, appropriate technology
Studi Numerik Sambungan Spun Pile Terhadap Pile Cap Dengan Dan Tanpa Beton Pengisi Akibat Pembebanan Siklik Vania Callista; Yuskar Lase; Widjojo Adi Prakoso; Mulia Orientilize
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.681

Abstract

Abstrak Berdasarkan SNI 8460, spun pile sebagai struktur bawah didesain belum menggunakan konsep performance-based design (PBD) karena pertimbangan sulitnya proses perbaikan, meskipun PBD sudah diperbolehkan di negara lain. Peta gempa tahun 2017 menunjukkan adanya peningkatan seismic demand di Indonesia yang menyebabkan desain fondasi yang tidak efisien jika perilaku inelastic pada pondasi akibat gempa besar tidak diperbolehkan. Untuk mempelajari perilaku inelastic pondasi, tiga sambungan spun pile berukuran full scale diuji dengan pembebanan siklik horizontal. Analisis lanjutan dengan finite element (FE) dilakukan menggunakan Abaqus. Karena kurangnya jumlah tulangan geser (spiral) pada spun pile yang ada di Indonesia, efek confinement dari pemodelan tulangan spiral dibandingkan dengan pemodelan jika spiral disederhanakan sebagai hoops. Analisis FE juga dilakukan untuk mempelajari perbandingan perilaku antara spun pile kosong dan dengan beton pengisi dalam hal kekuatan, daktilitas dan performance levels dari sambungan spun pile.  Kata kunci: sambungan spun pile, performance-based design, the effect of concrete infill, daktilitas                                                   Abstract According to SNI 8640, spun pile as part of lower structure is not designed with the concept of performance-based design (PBD) because of repair issues, although PBD has been allowed for lower structures in other countries. According to the 2017 seismic zone, the increasing seismic demand in Indonesia results in an inefficient foundation design if inelastic behavior of foundation due to a big earthquake is not allowed. Three full scales of spun pile connections were tested with lateral cyclic loading to explore the inelastic behavior of foundation. A finite element (FE) analysis using Abaqus was conducted for further study. Due to low number of spun piles shear reinforcement (spiral) produced in Indonesia, the confinement effect of spiral model is compared with hoops model. Finite element analysis was also done to investigate the behavior difference of hollow spun pile and spun pile with concrete infill in terms of strength, ductility, and performance levels of spun piles connection. Keywords: spun pile connection, performance-based design, the effect of concrete infill, ductility
Studi Numerikal Grup Fondasi Elevated Pile Cap Pada Tanah Pasir Fathia Handayani Kamal; Widjojo Adi Prakoso; Mulia Orientilize
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.682

Abstract

Abstrak Elevated Pile Cap (EPC) merupakan fondasi tertanam sebagian di dalam tanah yang rentan terhadap beban gempa karena momen fleksural yang terjadi lebih besar daripada jenis fondasi yang tertanam sepenuhnya. Studi numerikal dengan metode BNWF menggunakan aplikasi OpenSees berbasis eksperimen yang dilakukan peneliti lain dilakukan untuk mempelajari perilaku non-linear fondasi di tanah pasir. Fondasi berkonfigurasi tunggal, 2x2, dan 2x3 dimodelkan dan divalidasikan terhadap penelitian tersebut. Variasi nilai densitas pasir dan pemberian nilai p-multiplier yang berbeda diperhitungkan per baris fondasi grup. Analisis pushover monotonik dilakukan untuk mengetahui perilaku ineastik fondasi. Semua model membentuk sendi plastis pada sambungan dan di bawah tanah pada tiang leading row. Perbandingan respons individu tiap tiang dengan respons rata-rata fondasi per tiang digunakan untuk mengetahui distribusi gaya pada fondasi yang dipengaruhi oleh nilai p-multiplier. Kuat geser tanah divariasikan untuk mengetahui keelastisitasan tanah saat pembebanan di titik tertentu, di mana semakin padat tanah maka semakin cepat fase plastis tercapai. Secara keseluruhan, variasi kepadatan tanah dan nilai p-multiplier mempengaruhi perilaku inelastis fondasi. Kata kunci: EPC, fondasi grup, sendi plastis, p-multiplier, analisis pushover                                                Abstract Elevated Pile Cap (EPC), a partially-embedded foundation, is vulnerable under seismic loadings since it suffers more flexural moment than average foundations. A BNWF numerical study was performed using OpenSees based on an experiment conducted in China. The 1x1, 2x2, and 2x3 rectangular EPC groups were modeled and validated by the test result. Each model is embedded in sand with a varied density and A different value of p-multiplier for each pile rows was considered. Monotonic pushover analysis was performed, and its inelastic behavior were investigated. All models suffer double plastic hinges on the leading row, located in connection and underground, depending on the soil density. The ratio of each pile row response to the average pile group response is an indicator to examine the forces distribution, influenced by p-multiplier only. The soil shear strength was investigated to observe the elasticity of soil when it reach its yield, ultimate, and the formed of plastic hinges. The p-multiplier and varied soil density affects the soil strength for pile rows, the denser the soil, the faster it reaches its plastic state. Overall, both p-multiplier and soil density affect inelastic behavior of foundations. Keywords: EPC, group foundation, plastic hinge, p-multiplier, pushover analysis
Pengaruh Penggunaan Limbah Polyethylene Terephthalate Terhadap Campuran Aspal Concrete Binder Course Abdul Gaus; Raudha Hakim; Seniyasmin Seniyasmin
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.683

Abstract

Abstrak Penggunaan plastik sebagai kemasan makanan dan minuman hingga saat ini belum tergantikan, dampaknya keberadaan limbah plastik semakin meningkat. Unsur penyusun utama plastik adalah karbon dan hydrogen hal ini identik dengan unsur penyusun utama dari aspal. Indonesia merupakan salah satu negara pengimpor aspal, 50% kebutuhan aspal dalam negeri dipenuhi dengan mengimpor dari luar negeri. Salah satu solusi yang dapat dilakukan untuk mengurangi limbah plastik dan mengurangi impor aspal adalah penggunaan limbah plastik sebagai campuran aspal beton untuk mengurangi penggunaan aspal. Penelitian ini bertujuan untuk menganalisis pengaruh penggunaan limbah plastik jenis PET pada campuran aspal AC-BC. Limbah PET dibuat dalam bentuk serat yang ditambahkan dalam campuran aspal dengan komposisi 0.3% dan 0.6% yang dibanding dengan campuran aspal tanpa PET. Penambahan serat PET dalam campuran aspal menunjukkan bahwa stabilitas aspala semakin meningkat dengan bertambahnya persentase serat PET dalam campuran aspal, nilai flow menjadi lebih kecil hal ini mengindikasikan bahwa campuran aspal cenderung lebih kaku, nilai MQ juga menjadi lebih besar. Kata kunci: Aspal, plastik, limbah, marshall, PET   Abstract he use of plastic as food and beverage packaging has not been replaced until now, the impact of the existence of plastic waste is increasing. The main constituent elements of plastic are carbon and hydrogen, which are identical to the main constituent elements of asphalt. Indonesia is one of the asphalt importing countries, 50% of domestic asphalt needs are met by importing from other countries. One solution that can be done to reduce plastic waste and reduce asphalt imports is the use of plastic waste as a mixture of asphalt-concrete to reduce the use of asphalt. This study aims to analyze the effect of the use of PET type plastic waste on the AC-BC asphalt mixture. PET waste is made in the form of fiber which is added to the asphalt mixture with a composition of 0.3% and 0.6% compared to the asphalt mixture without PET. The addition of PET fibers in the asphalt mixture indicates that the asphalt stability increases with the increase in the percentage of PET fibers in the asphalt mixture, the flow value becomes smaller, this indicates that the asphalt mixture tends to be stiffer, the MQ value also becomes larger. Keywords: Asphalt, plastic, waste, marshall, PET
Pengaruh Abu Sekam Kayu Pada Nilai Unconfined Compression Strength Lempung Plastisitas Tinggi Terstabilisasi Semen Kapur Soewignjo Agus NUGROHO; Muhammad Faisal Al Ridho; Ferry Fatnanta
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.688

Abstract

Abstrak Perbaikan lempung dengan semen, kapur, dan abu sekam (RHA) terbukti meningkatkan kuat geser dan daya dukung. Kandungan silika abu sekam kayu (ASK) hampir sama dengan RHA. Penelitian melihat pengaruh ASK pada lempung terstabilisasi semen dan kapur. Pengujian Tekan bebas (UCS) dilakukan untuk membandingkan nilai kuat tekan bebas (qu) lempung asli, lempung distabilisasi semen, dan kombinasi semen dan kapur dan/atau ASK. Sampel diuji pada empat kondisi. Hasil UCS tanpa pemeraman, nilai qu seragam. Pada kondisi tanpa pemeraman dan perendaman, nilai qu semua variasi relatif sama. Pada kondisi pemeraman dan tanpa perendaman, nilai qu berkisar 365 kPa sampai dengan 485 kPa untuk campuran dengan ASK dan kombinasi kapur dengan ASK. Penambahan kapur 10% meningkatkan nilai qu lebih 1100 kPa. Hasil UCS membuktikan, kapur lebih optimal meningkatkan nilai qu dibanding ASK. Penggantian kapur dengan ASK 4% sampai 6% meningkatkan nilai qu menjadi 485 kPa (rendaman) dan menjadi 475 kPa (tanpa rendaman). Kata kunci: Abu sekam Kayu, Kapur, lempung, semen, stabilisasi  Abstract Clay stabilized with cement, lime, and rice hush ash (RHA) has been increasing shear strength and bearing capacity. The silica content of wood husk ash (ASK) is almost the same as RHA. The study seen effect of ASK on clay-cement and lime. Unconfined Compression Strength (UCS) is performed and compare unconfining strength values (qu) of clay, clay-cement, and cement and lime and/or ASK. Sampel was tested on four conditions. UCS results without watering, uniform qu value. Conditions non-curing and soaked, the qu values of all variations are relatively the same. In curing and unsoaked conditions, qu values range from 365 kPa to 485 kPa for ASK and lime with ASK. Adding 10% lime increases qu value more than 1100 kPa. Stabilized with lime is more optimal than ASK to increase qu. Subtitution lime with ASK 4% to 6% increases qu value to 485 kPa (soaked) and to 475 kPa (unsoaked). Keywords: clay, cement, lime, sawdust ash, stabilization 
Efektivitas Penggunaan Difa SS Pada Soil-Bottom Ash Dan Soil Cement Dalam Meminimalkan Kerusakan Sub-Grade Jalan Sumiati sumiati; Mahmuda Mahmuda; Siswa Indra
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.690

Abstract

Abstrak Salah satu penyebab kerusakan jalan adalah seringnya struktur perkerasan jalan terendam air saat musim hujan. Tanah lempung berplastisitas tinggi mempunyai sifat fisik dan teknik yang kurang baik jika digunakan sebagai lapisan tanah dasar (sub grade), karena mempunyai sifat kembang susut yang tinggi dan nilai CBR yang rendah jika terendam air. Stabilisasi menggunakan chemical additive dan limbah pabrik merupakan salah satu cara untuk memperbaiki sifat fisik dan teknik tanah, di mana akan memberikan hasil yang memadai jika komposisi campuran yang digunakan sesuai dan tepat. Oleh sebab itu akan diteliti efektifitas penggunaan aditif Difa SS pada Soil-Bottom ash dan Soil-Cement dengan melakukan pengujian CBR laboratorium unsoaked dan soaked. Hasil penelitian didapatkan bahwa penambahan Difa SS tidak memberikan peningkatan nilai CBR soaked pada Soil-bottom ash. Nilai CBR soaked Soil-Cement menunjukkan peningkatan dan lebih besar dibandingkan nilai CBR unsoaked sehingga Difa SS lebih efektif digunakan sebagai chemical additive pada Soil-Cement dalam usaha meminimalkan kerusakan jalan. Kata kunci: tanah-bottom ash, tanah-semen, Difa soil stabilizer.  Abstract One of the causes of road damage is that the pavement structure is often submerged in water during the rainy season. High plasticity clays soils have poor physical and technical properties when used as a subgrade layer, because they have high sweeling and shrinkage properties and low CBR values when submerged in water. Stabilization using chemical additives and factory waste is one way to improve the physical and engineering properties of the soil, which will give adequate results if the composition of the mixture used is appropriate and appropriate. Therefore, the effectiveness of the use of Difa SS additive in Soil-Bottom ash and Soil-Cement will be investigated by conducting unsoaked and soaked laboratory CBR testing. The results showed that the addition of Difa SS did not increase the soaked CBR value in soil-bottom ash. Soil-Cement soaked CBR value shows an increase and is greater than the unsoaked CBR value so that Difa SS is more effectively used as a chemical additive in Soil-Cement in an effort to minimize road damage. Keywords: soil-bottom ash, soil-cement, Difa soil stabilizer  
Model NRECA Untuk Prediksi Ketersediaan Air di Daerah Irigasi Citanduy Kota Tasikmalaya Sulwan Permana; Adi Susetyaningsih
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.693

Abstract

Abstrak Sektor pertanian masih merupakan primadona masyarakat dan dijadikan sebagai pekerjaan dalam menunjang kehidupan, meskipun banyak kawasan pertanian yang beralih fungsi menjadi pemukiman terutama di perkotaan. Hampir setiap tahun, luas panen mengalami penurunan. Untuk mengantisipasi hal tersebut, pemerintah dan pemerintah daerah telah banyak membangun infrastruktur keairan, terutama bendung dan bendungan. Daerah irigasi Citanduy dengan luas layanan 427 hektar merupakan salah satu daerah irigasi di Kota Tasikmalaya, sehingga sangat rentan terhadap alih fungsi lahan persawahan menjadi pemukiman. Ketersediaan air sangat penting dalam pemenuhan areal pertanian. Penelitian ini dilakukan untuk mengetahui debit andalan di DAS Citanduy-Sirnagalih seluas 474,65 km2. Terdapat 2 pos curah hujan yaitu Cigede dan Tejakalapa selama sepuluh tahun dari tahun 2009 hingga 2018. Curah hujan rata-rata bulanan dihitung dengan metode Thiessen dengan proporsi luas pengaruh adalah 0,4 dan 0,6. Evapotranspirasi dihitung menggunakan metode Penman-Monteith, dan pemodelan debit menggunakan metode NRECA. Pos duga air Asta-Cikunir digunakan sebagai acuan dalam menentukan parameter kalibrasi yaitu PSUB, GFW, dan tampungan air tanah awal dengan nilai 0,8, 0,29: 100, serta nilai NSE 0,719. Debit andalan Q80 adalah 17,4 m3/s. Debit andalan adalah ketersediaan air di daerah irigasi Citanduy. Berdasarkan debit andalan ini, musim tanam I dan II masih dapat dilakukan secara bersamaan. Kata kunci: debit andalan, kalibrasi, NSE, sungai Citanduy   Abstract The agricultural sector is still the prima donna of the community and is used as a job to support life. However, many agricultural areas have been converted into settlements, especially in urban areas. Almost every year, the harvested area has decreased. To anticipate this, the government and local governments have built a lot of water infrastructure, especially weirs and dams. The Citanduy irrigation area with a service area of 427 hectares is one of the irrigation areas in the City of Tasikmalaya, so it is very vulnerable to the conversion of rice fields into settlements. The availability of water is crucial in fulfilling agricultural areas. This research was conducted to determine the mainstay discharge in the Citanduy-Sirnagalih watershed covering an area of 474.65 km2. There are two rainfall posts, namely Cigede and Tejakalapa, for ten years from 2009 to 2018. The average monthly rainfall is calculated by the Thiessen method, with the proportion of the area of influence being 0.4 and 0.6. Evapotranspiration was calculated using the Penman-Monteith method and discharge modeling using the NRECA method. The Asta-Cikunir water gauge post is used as a reference in determining calibration parameters, namely PSUB, GFW, and initial groundwater reservoirs with values of 0.8, 0.29: 100, and NSE values of 0.719. The Q80's dependable flow is 17.4 m3/s. The mainstay of debit is the availability of water in the Citanduy irrigation area. Based on this reliable discharge, planting seasons I and II can still be carried out simultaneously. Keywords: dependable flow, calibration, NSE, Citanduy river 
Efek Perkuatan Glass Fiber Reinforce Polymer Sheet Pada Balok Beton Bertulang Dengan Tulangan Korosi Mufti Amir Sultan; Ridwan AR; Abdul Gaus
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.694

Abstract

Abstrak Artikel ini menyajikan tentang balok beton bertulang yang tulangannya telah korosi kemudian diberi perkuatan ekternal berupa serat glass tipe lembaran atau Glass Fiber reinforced Polymer-Sheet (GFRP-S). Pada studi ini variabel berdasarkan variasi tingkat korosi pada tulangan. Lima macam benda uji yang digunakan berbentuk balok dengan dimensi 15x20 cm panjang 160 cm. Tulangan utama yang digunakan besi f12 dan tulangan sengkang f8-100. Mutu beton digunakan 25 MPa. Balok beton bertulangan normal tanpa perkuatan sebagai balok kontrol (BN), balok beton bertulangan normal dengan perkuatan GFRP-S (BP), balok beton bertulangan korosi dengan perkuatan GFRP-S (BPK), variasi waktu pengkorosian tulangan selama 2 minggu (BPK2), 4 minggu (BPK4) dan 6 minggu (BPK6) dengan metode perendaman pada larutan asam sulfat 2,0%. Balok diperkuat GFRP-S pada daerah Tarik di bagian bawah balok. Pengujian lentur dengan twopoint load. Hasil penelitian menunjukkan bahwa balok beton bertulang yang diperkuat dengan GFRP-S mempunyai kapasitas lebih besar dibandingkan dengan balok normal sebesar 12,07%. Balok beton bertulang dengan tulangan tingkat korosi lebih besar (pengkorosian 6 minggu) cenderung menurunkan kapasitas balok namun kapasitasnya masih lebih besar dari balok normal sebesar 1,38%. Kata kunci: balok beton, tulangan korosi, asam sulfat, GFRP-S  Abstract This article presents about reinforced concrete beams whose reinforcement has been corroded and then externally reinforced in the form of sheet type glass fiber or Glass Fiber Reinfroced Polymer-Sheet (GFRP-S). In this study, the variables are based on variations in the level of corrosion on the reinforcement. Five kinds of test objects used in the form of blocks with dimensions of 15x20 cm and length of 160 cm. The main reinforcement used is f12 and f8-100 stirrup reinforcement. The quality of the concrete used is 25 MPa. Normal reinforced concrete beams without reinforcement as control beams (BN), normal reinforced concrete beams with GFRP-S reinforcement (BP), corrosion reinforced concrete beams with GFRP-S reinforcement (BPK), variations in reinforcement corrosion time for 2 weeks (BPK2), 4 weeks (BPK4)and 6 weeks (BPK6) by immersion method in 2.0% sulfuric acid solution. The beam is reinforced with GFRP-S in the Tensile region at the bottom of the beam. Flexural test with two point load. The results showed that reinforced concrete beams reinforced with GFRP-S had a larger capacity than normal beams by 12.70%. Reinforced concrete beams with reinforcement with a higher corrosion rate (6 weeks corrosion) tend to reduce the capacity of the beam but its capacity is still larger than normal beams by 1.38%. Keywords: concrete beam, corrosion reinforcement, sulfuric acid, GFRP-S 

Filter by Year

2011 2026


Filter By Issues
All Issue Vol. 16 No. 2 (2026): Teras Jurnal (September 2026) Vol. 16 No. 1 (2026): Teras Jurnal Vol. 15 No. 1 (2025): Volume 15 Nomor 1, Maret 2025 Vol. 15 No. 2 (2025): Teras Jurnal (September) Vol. 14 No. 2 (2024): Volume 14 Nomor 2, September 2024 Vol. 14 No. 1 (2024): Volume 14 Nomor 1, Maret 2024 Vol. 13 No. 2 (2023): Volume 13 Nomor 2, September 2023 Vol. 13 No. 1 (2023): Volume 13 No 1, Maret 2023 Vol. 12 No. 2 (2022): Volume 12 Nomor 2, September 2022 Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022 Vol. 11 No. 2 (2021): Volume 11 Nomor 2, September 2021 Vol. 11 No. 1 (2021): Maret 2021 Vol. 10 No. 2 (2020): Volume 10 Nomor 2 September 2020 Vol. 10 No. 1 (2020): Volume 10 Nomor 1 Vol. 9 No. 2 (2019): Volume 9, Nomor 2, September 2019 Vol. 9 No. 1 (2019): Volume 9, Nomor 1, Maret 2019 Vol. 8 No. 2 (2018): Vol 8 No 2 September 2018 Vol. 8 No. 1 (2018): Vol 8 Nomor 1, Maret 2018 Vol. 7 No. 2 (2017): Vol. 7 Nomor 2, September 2017 Vol. 7 No. 1 (2017): Vol 7 No 1 Maret 2017 Vol. 6 No. 1 (2016): Volume 6 Nomor 1 (2016), Teras Jurnal, Vol 6 No 1, Maret 2016 Vol. 6 No. 2 (2016): Volume 6 Nomor 2, September 2016 Vol. 5 No. 2 (2015): TERAS JURNAL Vol.5, No.2, September 2015 Vol. 5 No. 1 (2015): TERAS JURNAL, Vol. 5, No. 1, Maret 2015 Vol. 4 No. 2 (2014): TERAS JURNAL, VOL.4, NO.2, SEPTEMBER 2014 Vol. 4 No. 1 (2014): TERAS JURNAL, VOL.4, NO.1, MARET 2014 Vol. 3 No. 2 (2013): Teras Jurnal, Vol 3, No 2, September 2013 Vol. 3 No. 1 (2013): Teras Jurnal, Vol 3, No.1, Maret 2013 Vol. 2 No. 4 (2012): Teras Jurnal, Vol 2, No 4, Desember 2012 Vol. 1 No. 1 (2011): Teras Jurnal, Vol.1, No.1, Maret 2011 More Issue