Comparing Temperature and Humidity Control Using PID and Fuzzy Logic in a Climatic Chamber Putra, Affan Kurnia; Rahmawati, Triana; Assalim T.P, Moch.Prastawa; Misra, Shubhrojit
Jurnal Teknokes Vol. 17 No. 2 (2024): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The presence of a thermohygrometer is important in some places, especially in hospitals and climate room equipment. A climate chamber is an enclosed space or isolated environment, which will provide the environmental conditions of relative humidity and temperature. In accordance with the Decree of the Minister of Health of the Republic of Indonesia. Certain rooms such as rooms in hospitals require special attention to environmental conditions, such as the surgical process that occurs in the operating room. A thermohygrometer is a tool used to monitor room conditions. The thermoygrometer used must be able to trace the measurement results using certain media. A climate chamber is a device that provides the desired climate regardless of the external environment. The purpose of this study was to analyze the comparison of PID and Fuzzy Logic temperature control systems on the Climatic Chamber (Fuzzy Logic System) device which plays a role in the process of measuring room temperature and humidity in the field. The method used in this study was to compare directly with a previously calibrated thermohygrometer. The measurement results at 25°C have a response time of 7 minutes 30 seconds and an overshoot of 0.1°C, at a temperature of 30°C has a response time of 5 minutes 15 seconds and an overshoot of 0.1°C, at a temperature of 35°C has a response time of 5 minutes 30 seconds and 0.2°C overshoot. At 50%RH Humidity has a response time of 13 minutes 30 seconds, at 60%RH Humidity has a 12 minute response time, At 70%RH Humidity has a 6 minute response time. The measurement results show that fuzzy logic control has more advantages than PID control. Fuzzy logic control has a faster response time to setpoint than PID control and fuzzy logic control has smaller overshoot compared to PID control.
Measuring Instruments for Oxygen Concentration, Flow, Temperature, and Humidity in CPAP Equipped with Microcontroller Based External Data Storage Wafa, Muhammad Ali; Assalim Tetra Putra, Moch. Prastawa; Wakidi, Levana Forra; Misra, Shubhrojit
Jurnal Teknokes Vol. 16 No. 3 (2023): September
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The recommended approach for addressing sleep apnea in infants involves the utilization of CPAP therapy. A pivotal component of CPAP therapy is the inclusion of a humidifier, which serves to counteract potential hazards by introducing humidified air. The purpose of this study was centered on developing a compact, portable model to assess temperature and humidity parameters in CPAP humidifiers. The method utilized was the pre-experimental One Group Post Test Design. The contribution of this research lies in its ability to measure temperature and humidity in the CPAP humidifier using the SHT30 sensor. The sensor readings were processed using the Arduino Mega 2560 Pro Mini microcontroller. The measurement data was presented on a 20x4 LCD screen and had the capability to be stored using an SD Card, alongside the inclusion of a buzzer indicator on the tool. The results demonstrated that the highest error value for the temperature parameter was 1.8%, while the lowest was 0.49%. The expected conclusion is that these findings can be implemented effectively to assist operators in recording, measuring, and monitoring temperature and humidity in CPAP humidifiers and to facilitate monitoring of sleep apnea treatment procedures.
Comparing Temperature and Humidity Control Using PID and Fuzzy Logic in a Climatic Chamber Putra, Affan Kurnia; Rahmawati, Triana; Assalim T.P, Moch.Prastawa; Misra, Shubhrojit
Jurnal Teknokes Vol. 17 No. 2 (2024): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The presence of a thermohygrometer is important in some places, especially in hospitals and climate room equipment. A climate chamber is an enclosed space or isolated environment, which will provide the environmental conditions of relative humidity and temperature. In accordance with the Decree of the Minister of Health of the Republic of Indonesia. Certain rooms such as rooms in hospitals require special attention to environmental conditions, such as the surgical process that occurs in the operating room. A thermohygrometer is a tool used to monitor room conditions. The thermoygrometer used must be able to trace the measurement results using certain media. A climate chamber is a device that provides the desired climate regardless of the external environment. The purpose of this study was to analyze the comparison of PID and Fuzzy Logic temperature control systems on the Climatic Chamber (Fuzzy Logic System) device which plays a role in the process of measuring room temperature and humidity in the field. The method used in this study was to compare directly with a previously calibrated thermohygrometer. The measurement results at 25°C have a response time of 7 minutes 30 seconds and an overshoot of 0.1°C, at a temperature of 30°C has a response time of 5 minutes 15 seconds and an overshoot of 0.1°C, at a temperature of 35°C has a response time of 5 minutes 30 seconds and 0.2°C overshoot. At 50%RH Humidity has a response time of 13 minutes 30 seconds, at 60%RH Humidity has a 12 minute response time, At 70%RH Humidity has a 6 minute response time. The measurement results show that fuzzy logic control has more advantages than PID control. Fuzzy logic control has a faster response time to setpoint than PID control and fuzzy logic control has smaller overshoot compared to PID control.
Fuzzy Logic Method to Control Evenly Distributed and Stable Waterbath Temperature with Four Heaters Kurniawan, Rifqi; Syaifudin, Syaifudin; Lamidi, Lamidi; Misra, Shubhrojit
Jurnal Teknokes Vol. 17 No. 1 (2024): March
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Water baths are commonly used in scientific fields to incubate samples at specific temperatures. The temperature of the water bath must be controlled precisely, because even the slightest temperature variation can affect the results of the experiment. It can handle imprecise, uncertain and incomplete information, making it suitable for temperature control in water baths. This research aims to determine the distribution and stability of fuzzy logic control to control the temperature of a water bath with four heaters. Even heat distribution from the four heaters will ensure consistent water bath temperature throughout the bath. This research uses an Arduino microcontroller to process the temperature sensor output from the DS18B20, then the processed temperature value will be displayed on the TFT LCD. The independent variable in this research is the temperature value, while the dependent variable is the DS18B20 temperature sensor. The largest error value from the module measurements is at a temperature setting of 30 ºC on the 2nd temperature sensor with an error value of 1.43%. Meanwhile, the smallest error value is found at a temperature setting of 35 ºC on the 1st and 4th temperature sensors with an error value of 0.01%. Data collection used a digital thermometer comparison tool with 10 repetitions as a temperature sensor reference tool. The results obtained using this sensor are more stable and have a high accuracy value. The results of the research show that the temperature difference between points 1 to 4 when viewed from the error percentage is very small, or it can be said that the temperature distribution is even. The conclusion from these results is that the module has a stable temperature value and the error value is low and is still within the tolerance limit. permitted is ±5%.
Analysis of Changes in Flow Setting Against Rise Time Using Gas Board 7500E Sensor on Bubble CPAP Pudji, Andjar; Amrinsani, Farid; Luthfiyah, Sari; Lusiana, Lusiana; Misra, Shubhrojit; Ahniar, Nur Hasanah; Barus, Yenda Mita; Lamidi , Lamidi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 2 (2022): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.143

Abstract

Respiratory distress syndrome (RDS) is a breathing disorder that occurs in newborns, often in premature babies born before 28 weeks of gestation. The bubble CPAP (Continuous Positive Airways Pressure) is a device used to provide positive pressure to newborns who can breathe spontaneously but are still prone to apnoea. The rise time is the time it takes for the airway pressure to reach the maximum standard value. The aim of this study is to analyze the changes in flow regulation during the rise time using a 7500E gas sensor card on a bubble CPAP probe. The method used in this study is to use the mean hijacking of the sensor to reduce the noise generated by the sensor. When analyzing the data, the researcher recorded data up to five times and calculated the mean measurement error. The research design is calibrated to confirm the correctness of the displayed values. The results of the data analysis are a mean error value of 0.88% at a setting of 30% oxygen content, 0.78% at a setting of 50%, and 0.95% at a setting of 90%. For liters per minute (LPM) at the 1 LPM and 5 LPM settings, the mean error values are 0.18 % and 0.03 % for the 10 LPM setting. From the test results with 3 bubble CPAP devices, it appears that when a high LPM setting is used, the oxygen concentration is reached faster with a mean value of ±10 seconds. The conclusion from this study shows that increasing the oxygen flow rate affects the duration of the rise in bubble CPAP oxygen concentration. The implication of this study is that this data will help add artificial intelligence to bubble CPAP to automatically determine settings by combining breathing data from patients.
Analysis of the Accuracy of Thermocouple Sensors at the Incubator Calibrator Laboratory Equipped with Internet of Thing-Based Data Storage Prastyadi, Candra; Irianto, Bambang Guruh; Ariswati, Her Gumiwang; Titisari, Dyah; Nyatte, Steyve; Misra, Shubhrojit
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 4 (2022): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.158

Abstract

Laboratory incubator is a tool used to incubate a breed. This incubator provides optimum temperature conditions for microorganisms to grow. It has a temperature regulator so that the temperature can be adjusted according to the breed incarnated. In this case, incubator worked like the hot-dry system of ovens. The purpose of this study was to conduct testing and analysis on the accuracy of thermocouple sensors using incubator media in laboratory incubator calibrator tools. The contribution of the research was to know the level of accuracy of the right sensor for sensing the temperature in the laboratory incubator. The main designed tool consisted of 8 MAX6675 standards, 8 K thermocouple, Arduino-Mega, and SD Card Standards. The temperature of the incubator device, in this case, was measured by the K thermocouple sensor. The sensor system had 8 channels that serve to measure the temperature at each incubator point. The temperature data were further stored in the SD card to analyze the data and the data can be processed into the form of a graphic. Benchmarking was done using a data logger temperature tool. This was done to make the designed tool results under the standards tool. After comparing between the tool designed and the standard tool obtained the largest error value of 3.98% in channel T6 at the temperature of 35°C with ordinary incubator media, while the smallest error in ordinary incubator media was at the point T6 at temperature of 37°C by 0.06%. Meanwhile, in the fan incubator, at the temperature of 35oC, had the largest error of 2.98%, while the smallest error was 0.86%. The conclusion of this study is that the tool designed could work well in measuring the temperature of the incubator, as well as the system for storing the data reading using the SD card.
Antenatal Care Bed For Preeclamsi Early Detection Based on Web System Ramadhan, Fiqih Fahrur; Pudji, Andjar; Mak’ruf, Muhammad Ridha; Misra, Shubhrojit
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 3 (2023): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i3.181

Abstract

One of the causes of the high maternal mortality rate is dominated by three factors, one of which is preeclampsia. Preeclampsia is a condition in which the mother experiences hypertension and changes in BMI (Body Mass Index) at the 20th week of gestation. Preeclampsia indications in pregnant women are related to examinations, namely Antenatal care (ANC). Antenatal care is one of the prenatal checks with certain standards. Pregnant women need extra antenatal supervision from health workers. Preeclampsia detection carried out in health care facilities is currently considered to be still not optimal so that there are still many cases of preeclampsia that are not handled properly. A web-based ANC test is one of the ways that services for pregnant women may be improved. To make NIBP and BMI data supplied and received by IoT media helpful for the diagnostic procedure, this study will evaluate them. Knowing the reaction of NIBP and BMI data provided and received over IoT medium is the contribution of this research. The MPX5050 sensor and Loadcell, whose output will be processed and presented on a web page, will be used in the technique to accomplish this purpose. Although the largest error value was -5.4 at the measurement point of 150 mmHg at diastole, it can be argued that the measurement findings for the NIBP parameter are plausible. Overall NIBP measures, however can be considered practicable and can be used to human measurements. Additionally, the weight parameter measurement data have an error value of 0.19328%. From this study, it can be inferred that transmitting IoT-based NIBP and BMI data has an impact on received lost data or delays. The findings from this study are expected to be developed in further research.
Design a Low-Cost Digital Pressure Meter Equipped with Temperature and Humidity Parameters Utomo, Bedjo; Hariwisana, I Dewa Gede; Misra, Shubhrojit
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 2 (2021): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.204

Abstract

Calibration is a technical activity which consists of determining one or more properties and characteristics of a product, process or service according to a predetermined special procedure. The purpose of calibration is to ensure measurement results comply with national and international standards. The purpose of this study is to design two mode digital pressure meter (DPM) device equipped with a thermo-hygrometer and pressure in which the design is completed with a selection mode to determine the positive and negative pressure (vacuum) using MPX 5050GP sensor as a positive pressure sensor. In this design DHT 22 sensors is used to measure the humidity and temperature. To test the leak test this device is also equipped with timer. This design uses a 2.4 inch Nextion TFT LCD screen to display data. Data analysis was performed by comparing modul with standard tools. In the measurement process, Mercury tensimeter was carried out 6 times the data and the smallest results were 0 mmHg on the module and 0 mmHg on the standard tool and the largest was 298.0 mmHg on the module and 300 mmHg on the standard tool. Data were collected in a room with a temperature of 31̊C and humidity of 87%. Finally, this design is applicable for daily used for electromedical engineer to calibrate the sphygmomanometer in the hospitals
Design and Development of Electricity Use Management System of Surabaya State Shipping Polytechnic Based on Decision Tree Algorithm Realdo, Adam Meredita; Nugraha, Anggara Trisna; Misra, Shubhrojit
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 4 (2021): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.215

Abstract

Electrical energy has become a primary need in society, including in education. This is related to the number of electrical equipment used to support teaching and learning activities. However, this is not directly proportional to the students' awareness of the importance of saving energy. From this, the authors create a management system for electric power, which aims to save electricity consumption by limiting the use of electrical loads. In this system, the method used is a decision tree; the goal is to limit and set priorities for electrical loads. When three classes are ON simultaneously, there will be a reduction in the electrical load. There is a website for monitoring and changing the automatic or manual mode in this system. The manual mode is used to control the electrical load according to the status entered on the website. While the automatic mode regulates the use of electrical loads by controlling the ON or OFF conditions using a schedule that has been made, the website also monitors current, voltage, power, energy, and usage costs. The system has been tested with automatic and manual modes for monitoring data on the website. It has data updates every 10 minutes. The system has also been tested by scheduling using a decision tree and compared with scheduling without using a decision tree. From the test results for a day, it can be concluded that the system created is able to save electricity consumption. This is reinforced by a decrease in energy use of 1,17 kWh and a cost of Rp. 1.116