Evaluasi Mutu Beton Menggunakan Beton Inti Diameter Kecil Yulius Rakhman; Herman Parung; Rita Irmawaty
Jurnal Penelitian Enjiniring Vol 23 No 1 (2019)
Publisher : Center of Techonolgy (COT), Fakultas Teknik, Universitas Hasanuddin

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (404.291 KB) | DOI: 10.25042/jpe.052019.10

Abstract

Salah satu penyebab keterbatasan pengambilan sampel beton inti karena keberadaan tulangan pada struktur beton. Jika digunakan diameter core besar, dapat menurunkan kapasitas struktur beton dengan adanya tulangan yang terpotong. Oleh karena itu, dilakukan studi penggunaan core beton diameter kecil untuk memprediksi kuat tekan beton diameter kecil terhadap silinder beton diameter standar. Benda uji berupa (a) silinder beton berdiameter 10 cm dan tinggi 20 cm; (b) 2 plat beton berdimensi 45cm x 45cm x 13cm; dan (c) 4 balok beton berdimensi 70cm x 30cm x 15cm. Metode pengambilan sampel core diameter 2 inchi dan 1 inchi dengan arah sejajar dan tegak lurus arah pengecoran. Ada 2 variasi mutu beton yaitu 20 MPa dan 30 Mpa dengan MSA masing-masing 10 mm dan 20 mm. Pengujian kuat tekan dan modulus elastisitas beton dilakukan, serta uji normalitas beton inti untuk mengevaluasi kecukupan benda uji. Dari hasil pengujian dapat disimpulkan bahwa kuat tekan beton inti 2 inchi dengan pengambilan benda uji sejajar dan tegak lurus arah pengecoran memenuhi syarat uji normalitas, sehingga dapat direkomendasikan dengan jumlah sampel 25 buah, sedangkan untuk sampel berdiameter 1 inchi jumlah sampelnya perlu ditambah
Analisa Pola Kegagalan Balok Beton Menggunakan GFRP Bar Tanpa Selimut Beton Husein, Saddam -; Djamaluddin, Rudy; Irmawaty, Rita; Kusnadi, Kusnadi
Jurnal Penelitian Enjiniring Vol 24 No 1 (2020)
Publisher : Center of Techonolgy (COT), Fakultas Teknik, Universitas Hasanuddin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/jpe.052020.02

Abstract

SADDAM HUSEIN. Analisa Pola Kegagalan Balok Beton Menggunakan GFRP Bar Tanpa Selimut Beton (dibimbing oleh Rudi Djamaluddin dan Rita Irmawaty) Struktur beton bertulang yang menggunakan tulangan baja pada daerah korosif, menjadi rawan terhadap kerusakan atau penurunan kekuatannya akibat korosi.Korosi pada tulangan baja merupakan salah satu faktor penyebab menurunnya kekuatan struktur beton bertulang. Salah satu material yang dikembangkan mengatasi korosi adalah penggunaan material tulangan GFRP (Glass Fiber Reinforced Polymer). Penelitian ini bertujuan untuk menganalisa kapasitas lentur dan pola kegagalan balok beton tanpa selimut dengan menggunakan material tulangan GFRP bar. Desain penelitian merupakan eksperimental laboratorium dengan rekapitulasi sebanyak 6 sampel yang terdiri dari 2 Balok beton menggunakan tulangan baja dengan selimut beton, 2 balok beton menggunakan tulangan GFRP bar dengan selimut beton, 2 balok beton menggunakan GFRP bar tanpa selimut beton. Metode pengujian dilakukan dengan dengan pengujian lentur statik monotonik dan Analisis data menggunakan uji kondisi retak awal dan kondisi ultimit. Hasil penelitian ini menunjukkan bahwa kapasitas lentur pada balok dengan tulangan GFRP bar lebih besar dibandingkan dengan balok tulangan baja dan mampu meningkatkan kapasitas lentur balok dalam menahan beban sebesar 39.76 %, pola kegagalan beton yang terjadi pada balok tulangan baja mengalami kegagalan lentur tekan ditandai dengan retakan yang terjadi pada sisi tertekan dan membentuk retakan tegak dengan sumbu netral beton yang tertekan, sedangkan pada balok beton tulangan GFRP tanpa selimut mengalami kegagalan keruntuhan tekan geser dengan kondisi tulangan berdeformasi (bi-linear) dengan retak miring dan secara tiba-tiba menjalar menuju sumbu netral beton yang tertekan sehingga terjadilah keruntuhan secara tiba-tiba. SADDAM HUSEIN.Failure mode analysis of concrete Beams Using GFRP rebar Without concrete cover (supervised by Rudi Djamaluddin and Rita Irmawaty) Reinforced concrete that uses rebar steel in corrosive areas, are prone to damage or decreased strength due to corrosion. Corrosion in the steel reinforcement is one of the factors that decreasing strength of reinforced concrete. One of the materials developed to overcome corrosion is the use of GFRP (Glass Fiber Reinforced Polymer) reinforcement material. This study aims to analyze the flexural capacity and failure mode of concrete beams without concrete cover using material GFRP bar as reinforcement. The research design was an experimental laboratory with a recapitulation of 6 samples consisting of 2 beams using steel reinforcement with concrete cover.2 concrete beams using reinforcement GFRP bar with concrete cover, 2 beams using GFRP bars without concrete cover. The research method uses the monotonic static flexure and analyzing the data using the initial crack condition and ultimate conditions test. The results of the research indicate the flexural capacity of the beams with GFRP bar reinforcement is higher than steel reinforcement beams and can increase 39.76% of the flexural capacity of the beams in holding loads , the failure mode analysis occurs in steel reinforcing beam experiences compressive failure. Failure was characterized by cracks that occur on the depressing side and form an upright crack with the neutral axis of the compressed concrete, whereas in GFRP reinforced concrete beams without concrete cover, failure of shear compression with conditions of deformed reinforcement (bi-linear) with sloping cracks and suddenly spread towards the neutral axis of the compressed concrete so that there was a sudden collapse.
Analisis Pola Kegagalan Balok Sistem Rangka dengan Perkuatan di Daerah Tumpuan Darwis, Mardis; Djamaluddin, Rudy; Irmawaty, Rita; Amir, Astiah
Jurnal Penelitian Enjiniring Vol 24 No 1 (2020)
Publisher : Center of Techonolgy (COT), Fakultas Teknik, Universitas Hasanuddin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/jpe.052020.03

Abstract

The previous research of using truss system reinforcement in the beam without concrete (BTR) in the tension zone causes a decrease in flexural capacity due to the failure in the area near the support. Therefore, it is necessary to add tensile reinforcement in the support zone. This study aims to analyze the ultimate capacity of the truss system concrete beam strengthened with tensile reinforcement and to analyze the effect of tensile reinforcement in support zone due to crack pattern. This study was conducted experimentally in the laboratory. The dimension of truss reinforced concrete specimens are 15 cm x 20 cm x 330 cm that added tensile reinforcement with three types of length, they are BTRP 40D, BTRP 50D, and BTRP 60D, where D (13 mm) is diameter of tensile reinforcement. The flexural test is carried out by monotonic static loading. The results showed that tensile reinforcement in BTRP 40D was not able to carry the ultimate capacity due to premature failure in the support zone. while BTRP 50D and BTRP 60D specimens can enhance the ultimate capacity without facing premature failure in the support zone. The tensile reinforcement of 60D has the highest ultimate capacity because it can carry the biggest loads and minimum crack pattern.