Peningkatan Kegiatan Dinas Jaga Mesin pada Pengoperasian Mesin Penggerak Utama pada KM. Hasil Melimpah 18 I Made Aditya Nugraha; Rasdam Rasdam; Resky Amalia Rajab
Jurnal Sumberdaya Akuatik Indopasifik Vol 5 No 4 (2021): November
Publisher : Fakultas Perikanan dan Ilmu Kelautan, Universitas Papua

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.46252/jsai-fpik-unipa.2021.Vol.5.No.4.179

Abstract

Watchkeeping is guard work carried out on ships or in ports to create situations and conditions to be safe and under control for 24 hours carried out with the aim of work affairs in order to create safety and security while on duty. Hasil Melimpah 18 Vessel is classified as a fishing vessel of a special type only to accommodate fish cargo and does not carry out fishing operations. In an effort to achieve the goal of watchkeeping, a study is carried out related to the evaluation of the activities of the watchkeeping in the operation of the machine. From the results of observations, it is necessary to increase the activities of the watchkeeping in the operation of the main engine. This needs to be done to improve the performance before and after the machine is operated, and the watchkeeping when the machine is operating. The increase in the activities of the watchkeeping in the operation of the main engine can be done by several improvements, such as in the preparation, operation, and watchkeeping duty activities. In preparation activities, it is necessary to increase the availability of OHS equipment, logbooks, and spare parts as needed. In operating activities, it is necessary to increase the availability of OHS equipment, communication tools, and electrical panels. In watchkeeping duty activities, it is necessary to increase the availability of the watchkeeping schedule, machine daily journals, and measuring tools. Periodic control while the machine is operating is very important. The watchkeeper must have a big responsibility because machine damage can occur if the duty officer on duty commits negligence.
Analisis Pemanfaatan PLTS 80 Wp sebagai Sumber Energi Listrik pada Kapal 3 GT di Desa Tablolong Nusa Tenggara Timur I Made Aditya Nugraha; Febi Luthfiani; Jhon Septin Mourisdo Siregar; Rasdam Rasdam; Resky Amalia Rajab
Jurnal Sumberdaya Akuatik Indopasifik Vol 7 No 1 (2023): Februari
Publisher : Fakultas Perikanan dan Ilmu Kelautan, Universitas Papua

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.46252/jsai-fpik-unipa.2023.Vol.7.No.1.203

Abstract

The use of fossil energy as a source of fuel to turn on generators on fishing boats has long been used to assist fishing activities in Tablolong Village. The availability and lack of good use of this energy continuously will certainly be very bad for the sustainability of the fishermen's economy and the environment. The utilization of solar energy which has such great potential in East Nusa Tenggara can be one solution. The use of this technology is in line with the Blue Economy policy by the Ministry of Marine Affairs and Fisheries Republic of Indonesia. This 80 Wp PV system is installed on a 3 GT ship, then the energy that can be generated is analyzed and the Wilcoxon test is carried out to determine the fishermen's response to the use of the PV System. The utilization of the PV System as a source of electrical energy on 3GT vessels in Tablolong Village can meet the electrical energy needs of fishing boats. The electrical energy generated can meet 189% of the ship's electricity needs of 320 Wh/day with energy that can be produced by PV of 604.04 Wh/day. This result is also supported by the Wilcoxon test of the energy produced by PV for the ship's electrical energy needs. Based on the assessment indicators that have been carried out from before and after PV installation activities on fishing boats, it was found that there was a significant difference in the electrical energy needs before and after using PV System with a significant value of 0.001 (p < 0.05).