Analysis Of The Effect Of Hemodialysis Frequency On Hemoglobin, Ureum, Creatinine And Albumin Levels In Chronic Kidney Failure Patients At Praya Hospital Yunan Jiwintarum; Kurnia Anindita; Erlin Yustin Tatontos; Yudha Anggit Jiwantoro
Jurnal Analis Medika Biosains (JAMBS) Vol. 13 No. 01 (2026): JURNAL ANALIS MEDIKA BIOSAINS (JAMBS)
Publisher : Poltekkes Kemenkes Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Chronic Kidney Disiase (CKD) is a progressive loss of kidney function characterized by the inability of the kidneys to excrete waste and maintain metabolic balance. When kidney function declines, erythropoietin production decreases, resulting in anemia. other complication, such a hypoalbuminemia, are also common. Urea and creatinine levels are vital parameters of assessing kidney function. Hemodialysis is a common therapy for CKD patients; therefore, evaluating laboratory parameters such as haemoglobin, urea, creatinine, and albumin levels according to the frequency of hemodialysis is essential to determine treatment effectiveness. This analytical observational study with a cross-sectional design evaluated the effectiveness of bi-weekly hemodialysis among 32 chronic kidney disease patients at Praya General Hospital in May 2025. The results indicated that while routine hemodialysis significantly reduced urea levels from 137.9 mg/dL to 17.6 mg/dL and creatinine from 10.7 mg/dL to 2.5 mg/dL, these metabolic waste parameters tended to increase slightly after six months. In contrast, hemoglobin levels remained relatively stagnant at approximately 8.2–8.3 g/dL, signifying persistent moderate anemia despite regular treatment. Notably, albumin levels showed a steady and gradual improvement over the six-month period, rising from 3.4 g/dL to 4.0 g/dL, which suggests an enhanced protein status in patients adhering to the prescribed hemodialysis frequency.
Analisis Pengaruh Variasi Waktu Inkubasi Sampel Terhadap Tingkat Presisi Dan Akurasi Pada Quality Control (QC) Pemeriksaan Cholesterol : Analysis of the Effect of Variations in Sample Incubation Time on Precision and Accuracy Levels in Quality Control (QC) of Cholesterol Testing Yunita Wardani; Urip Urip; Yunan Jiwintarum; Iswari Pauzi
Jurnal Teknologi Laboratorium Medik Borneo Vol. 5 No. 2 (2025): Jurnal Teknologi Laboratorium Medik Borneo
Publisher : Institut Teknologi Kesehatan dan Sains Wiyata Husada Samarinda

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35728/jutelmo.v5i2.2041

Abstract

Pemeriksaan cholesterol metode fotometri memerlukan waktu inkubasi yang konsisten untuk menjamin presisi dan akurasi hasil.Tujuan penelitian ini Mengetahui pengaruh variasi waktu inkubasi sampel terhadap Tingkat presisi dan akurasi pada quality control (QC) hasil pemeriksaan cholesterol menggunakan metode fotometri.Penelitian ini merupakan penelitian kuantitatif dengan pendekatan eksperimental dimana populasi dan sampel penelitian ini adalah serum darah responden untuk pemeriksaan cholesterol. Penelitian ini dilakukan dengan mengukur kadar cholesterol variasi waktu inkubasi yang di modifikasi menjadi empat perlakuan yaitu, satu variasi waktu inkubasi (5 menit),variasi waktu inkubasi (10 menit), variasi waktu inkubasi (15 menit) dan variasi waktu inkubasi (20 menit). Data dianalisis untuk presisi dan akurasi, serta diuji statistik menggunakan One-Way ANOVA.Hasil pemeriksaan didapatkan Variasi waktu inkubasi pada kelompok perlakuan (5 menit) menunjukkan KV 3,30% dan recovery 98,78% hasil presisi dan akurasi, kelompok perlakuan (10 menit) menunjukkan KV 2,87% dan recovery 99,86% hasil presisi dan akurasi, kelompok perlakuan (15 menit) menunjukkan KV 2,56% dan recovery 100,20% hasil presisi dan akurasi, dan kelompok perlakuan (20 menit) menunjukkan 2,92% dan recovery 101,36% hasil presisi dan akurasi. Analisis statistik dengan uji One-way ANOVA didapatkan hasil (p) .538 (P> 0,05) yang menunjukkan tidak ada pengaruh pada quality control pemeriksaan cholesterol metode fotometri.Kesimpulan yang didapat Presisi dan Akurasi dari pengaruh waktu inkubasi (5 menit),(10 menit),(15 menit),(20 menit),adalah bagus.