A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase Five-Level Inverter Leonardus Heru Pratomo; F. Danang Wijaya; Eka Firmansyah
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 6, No 1: March 2015
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (233.541 KB) | DOI: 10.11591/ijpeds.v6.i1.pp160-167

Abstract

The five-level inverter has been used for many applications in renewable energy systems. Even though its harmonic distortion was lower than the conventional two-level inverter. The five-level converter has some disadvantages such as increasing power semiconductor, complex pulse width modulation control methods, and problem with the voltage balancing of the capacitor. This paper aims to propose a modified five-level inverter based on sinusoidal pulse width modulation using phase shifted carrier to enhancing the capacitor voltage balancing. This modified five-level inverter reduces the overall cost and the complexity of the pulse width modulator. Thus making the proposed control system highly simple. The performance and its controller were validated by means of standard laboratory equipments. The analysis, simulation and implementation result showed better performance of five-level inverter.
Perancangan Transformator Frekuensi Tinggi untuk Konverter DC-DC Full-Bridge Phase-Shifted 200 W Johan Agung Irawan; Eka Firmansyah; F. Danang Wijaya
Seminar Nasional Aplikasi Teknologi Informasi (SNATI) 2013
Publisher : Jurusan Teknik Informatika, Fakultas Teknologi Industri, Universitas Islam Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Konverter dc-dc digunakan untuk menghindari penggunaan transformator frekuensi rendah yang memiliki ukuran besar dan berat pada proses konversi energi listrik dari energi terbarukan. Konverter dc-dc full-bridge menggunakan transformator frekuensi tinggi. Dengan bekerja pada frekuensi tinggi, transformator ini memiliki ukuran yang ringkas dan ringan. Penelitian ini bertujuan untuk merancang dan membuat transformator frekuensi tinggi untuk konverter dc-dc full-bridge phase-shifted 200 W dengan frekuensi penyaklaran 50 kHz dan memiliki efisiensi di atas 80%. Simulasi dengan software PSIM dan eksperimen terhadap transformator hasil rancangan telah dilakukan. Hasil simulasi PSIM menunjukkan bentuk gelombang yang hampir sama dengan hasil eksperimen. Transformator hasil eksperimen memiliki efisiensi 91,63-99,36%.Kata kunci—transformator frekuensi tinggi, konverter dc-dc fullbridge, pulse-width-modulation (PWM) phase-shifted, PSIM
Quasi-flat linear PM generator optimization using simulated annealing algorithm for WEC in Indonesia Budi Azhari; Fransisco Danang Wijaya
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 10, No 1 (2019)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/j.mev.2019.v10.29-35

Abstract

Linear permanent magnet generator (LPMG) is an essential component in recent wave energy converter (WEC) which exploits wave’s heave motion. It could be classified into tubular-type, flat-tricore type, and quasi-flat type. In previous researches, these three models have been studied and designed for pico-scale WEC. Design optimization has further been conducted for flat-tricore LPMG, by using simulated annealing (SA) algorithm. It modified some parameters to minimize the resulted copper loss. This paper aims to optimize a quasi-flat LPMG design by applying SA algorithm. The algorithm would readjust the initial LPMG parts dimension. Then, the output of the optimized design would be analyzed and compared. The results showed that the optimization could reduce the copper loss by up to 73.64 % and increase the efficiency from 83.2 % to 95.57 %. For various load resistances, the optimized design also produces larger efficiency. However, the optimized design has a larger size and produces larger cogging force than the initial design.
Effect of different core materials in very low voltage induction motors for electric vehicle Fransisco Danang Wijaya; Iftitah Imawati; Muhammad Yasirroni; Adha Imam Cahyadi
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 12, No 2 (2021)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/j.mev.2021.v12.95-103

Abstract

The use of squirrel cage induction motor for electric vehicle (EV) has been increasingly popular than permanent magnet and brushless motors due to their independence on rare materials. However, its performance is significantly affected by the core materials. In this research, induction motors performance with various core materials (M19_24G, Arnon7, and nickel steel carpenter) are studied in very low voltage. Three phases, 50 Hz, 5 HP, 48 V induction motor were used as the propulsion force testbed applied for a golf cart EV. The aims are to identify loss distribution according to core materials and compare power density and cost. The design process firstly determines the motor specifications, then calculates the dimensions, windings, stator, and rotor slots using MATLAB. The parameters obtained are used as inputs to ANSYS Maxwell to calculate induction motor performance. Finally, the design simulations are carried out on RMxprt and 2D transient software to determine the loss characteristics of core materials. It is found that the stator winding dominates the loss distribution. Winding losses have accounted for 52-55 % of the total loss, followed by rotor winding losses around 25-27 % and losses in the core around 1-7 %. Based on the three materials tested, nickel steel carpenter and M19_24G attain the highest efficiency with 83.27 % and 83.10 %, respectively, while M19_24G and Arnon7 possess the highest power density with 0.37 kW/kg and 0.38 kW/kg whereas, in term of production cost, the Arnon7 is the lowest.
Klem Aktif Tunggal Interleaved flyback dengan Kombinasi N-MOSFET dan P-MOSFET Andriyatna Agung Kurniawan; Eka Firmansyah; F. Danang Wijaya
Telematika Vol 11, No 1: Februari (2018)
Publisher : Universitas Amikom Purwokerto

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (824.747 KB) | DOI: 10.35671/telematika.v11i1.599

Abstract

Penggunaan topologi interleaved flyback dengan menyusun dua atau lebih rangkaian flyback dapat mengakibatkan peningkatan dampak tegangan kejut. Dengan meningkatnya dampak tegangan kejut akan berakibat meningkatnya pula resiko kerusakan sistem akibat tegangan  kejut  tersebut.  Dalam  penelitian  ini,  diusulkan  sebuah  rangkaian  klem  aktif tunggal untuk mengatasi masalah tegangan kejut yang timbul dari dua buah flyback yang tersusun  dalam  konfigurasi interleaved.  Selain  untuk  mengatasi  tegangan  kejut  yang timbul,  pemasangan  klem  aktif  tunggal  pada  interleaved  flyback  juga  mengurangi penggunaan komponen aktif dan pasif pada sistem sehingga dapat meningkatkan efisiensi dan mengurangi biaya produksi. Penelitian ini disimulasikan pada sistem area kerja 350 W dan dari simulasi diperoleh nilai efisiensi 91.8%. Kata Kunci: flyback, interleaved, klem, kejut.
DESAIN SISTEM PEMBANGKIT LISTRIK HIBRIDA BIOMASSA - PV UNTUK ELEKTRIFIKASI PEDESAAN DI DESA PALUH KURAU SUMATERA UTARA Denny Haryanto Sinaga; F. Danang Wijaya; T. Haryono
Prosiding SNST Fakultas Teknik Vol 1, No 1 (2016): PROSIDING SEMINAR NASIONAL SAINS DAN TEKNOLOGI 7 2016
Publisher : Prosiding SNST Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (513.834 KB)

Abstract

Elektrifikasi  pedesaan merupakan hal yang masih menjadi masalah di berbagai belahan dunia tak terkecuali Indonesia khususnya di Sumatera Utara. Peningkatan jumlah permintaan energi listrik yang belum diimbangi dengan penambahan kapasitas menyebabkan beberapa daerah pedesaan belum menikmati energi listrik, salah satunya adalah di desa Paluh Kurau. Fokus utama paper ini untuk mengkaji pemanfaatan limbah biomassa dari kelapa sawit sebagai bahan bakar pembangkit energi listrik dan dipadukan dengan sumber energi surya sebagai sumber energi terbarukan hibrida untuk elektrifikasi pedesaan. Sebuah desain pembangkit hibrida biomassa-PV diusulkan untuk memenuhi kebutuhan listrik di desa Paluh Kurau. Aspek jumlah potensi sumber daya biomassa dari kelapa sawit dan radiasi matahari yang diperoleh menjadi pertimbangan untuk mendapatkan ukuran pembangkit hibrida biomassa-PV yang optimal secara ekonomis. Pembangkit hibrida yang optimum berdasarkan simulasi terdiri dari PV 20 kW, biomassa 30 kW, 100 unit baterai dan inverter 20 kW dengan sistem pengisian baterai cycle charging. Konfigurasi ini dipilih dengan total net present cost sebesar US$ 274.643, biaya pembangkitan listrik (cost ofenergy)sebesar US$ 0,228 /kWh Kata kunci: Biomassa Desain, Elektrifikasi Pedesaan, Hibrida, PV
ANALISIS INVERTER SATU FASA PADA KONFIGURASI MASTER-SLAVE Noviarianto Noviarianto; F. Danang Wijaya; Eka Firmansyah
Prosiding SNST Fakultas Teknik Vol 1, No 1 (2016): PROSIDING SEMINAR NASIONAL SAINS DAN TEKNOLOGI 7 2016
Publisher : Prosiding SNST Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (454.544 KB)

Abstract

Inverter merupakan peralatan untuk mengkonversi sumber energi listrik DC menjadi AC. Sumber energi listrik dc diperoleh dari energi matahari dengan menggunakan panel surya. Pemilihan kapasitas daya inverter harus disesuaikan dengan sumber energi yang dihasilkan sehingga didapatkan daya dengan kapasitas yang optimal. Modul inverter dengan kemampuan kapasitas daya listrik yang relatif kecil merupakan salah satu alternatif. Walaupun kapasitasnya kecil modul inverter mempunyai sifat modular sehingga memungkinkan untuk dikembangkan. Beban listrik dengan kapasitas yang melebihi daya dari modul inverter dapat dilayani dengan cara memasang beberapa modul inverter secara paralel. Teknik master slave merupakan salah satu cara yang  dapat diterapkan pada proses paralel. Dengan menjadikan salah satu modul inverter sebagai master dan modul inverter yang lain terhubung sebagai slave. Simulasi dengan sofware menunjukkan bahwa teknik ini dapat membagi arus 60 – 50%, kemampuan mengikuti perubahan beban yang cukup seragam dan steady state yang cepat tercapai dalam waktu 10 ms. Kata kunci: inverter,  master-slave, paralel inverter, THD
STUDI PENGARUH JARI-JARI DALAM MAGNET TERHADAP TEGANGAN GENERATOR AKSIAL PADA BAHAN CAKRAM AKRILIK Pebri Prihatmoko; F. Danang Wijaya; Suharyanto Suharyanto
Jurnal Teknosains Vol 8, No 2 (2019): June
Publisher : Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/teknosains.30958

Abstract

The high cost of making rotor discs is one aspect that becomes an obstacle in the implementation of axial generator research. This study aims to compare acrylic discs with wooden discs in terms of axial generator output voltage and production costs, so that further research can use alternative discs with lower cost. This study uses an experimental method, where this method is used to find existing variables. On a generator with an acrylic disc, the average voltage is 16.6 volts with a manufacturing cost of 151,500 rupiah. Whereas on generator with wood disc, the average voltage is 17.2 volts with a manufacturing cost of 48,750 rupiah. Thus wood disc can be an alternative material in making cheap axial generator rotor discs.
Dimensi Context Aware untuk Manajemen Penerangan dalam Gedung Gusti Agung Ayu Putri; Ferdiana Ridi; FDanang Wijaya; Sayuri Egaravanda
IPTEK-KOM : Jurnal Ilmu Pengetahuan dan Teknologi Komunikasi Vol 15, No 2 (2013): JURNAL IPTEKKOM : Jurnal Ilmu Pengetahuan & Teknologi Informasi
Publisher : BPSDMP KOMNFO Yogyakarta, Kementerian Komunikasi dan Informatika

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33164/iptekkom.15.2.2013.91-102

Abstract

Inefisiensi energi pada sistem penerangan dalam gedung diantaranya karena tidak terkendalinya pemakaian penerangan secara konsisten. Salah satu alternatif penyelesaian permasalahan tersebut adalah perlu adanya manajemen sistem penerangan. Paper ini mencoba mengusulkan diagram dimensi context aware sistem manajemen penerangan yang merupakan pondasi untuk pengembangan sistem yang cerdas. Sebuah contoh arsitektur dan pengembangan kelas utama yang mengacu pada diagram tersebut dicoba untuk dikembangkan. Teknologi pervasive computing digunakan sebagai pendekatan awal desain sehingga pengelolaan dan pemantauan penerangan dapat dioptimalkan guna efisiensi energi listrik.
Perancangan dan Evaluasi User Interface Aplikasi Smart Grid Berbasis Mobile Application Edi Susilo; F. Danang Wijaya; Rudy Hartanto
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 7 No 2: Mei 2018
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1049.21 KB)

Abstract

Smart grid mobile application is a modernization in the consumption of electric power. Based on current research on smart grid mobile applications, it has investigated to the monitoring function, regulating, and scheduling energy consumption only. In the other case, the process of selling and buying electrical power is not inspected yet. This paper designedthe user interface (UI) of smart grid mobile application in the process of selling and purchasing the electrical power. This combined Materials Design for Android (MDfA) with a design that adopts Common Element Sets (CES). The results of UI design were tested using usability and User Experience (UX). Usability test used System Usability Scale (SUS) and UX test used User Experience Questionnaire (UEQ). The results of usability testing obtained a score of 72 that was considered above average and included in the category "good". UX test in each aspect obtained a score as follows: attractiveness 1.925, perspicuity 1.975, efficiency 1.913, dependability 1.730, stimulation 1.938, and novelty 1.988. Overall UX testing results were included into the category "very good".