Claim Missing Document
Check
Articles

Found 34 Documents
Search

PEMISAHAN DAN ANALISIS CESIUM DALAM PEB U3Si2/Al TMU 2,96 gU/cm3 PASCA IRADIASI DENGAN METODE PENGENDAPAN CHLOROPLATINATE Arif Nugroho; Boybul Boybul; Sutri Indaryati; Iis Haryati; Rosika Kriswarini; Aslina Br. Ginting
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 25 No. 2 (2019): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2019.25.2.5466

Abstract

Fuel burnup is an important parameter for determining the quality and integrity of irradiated nuclear fuel. The most important parameters in the calculation of burnup is the separation process and 137Cs content analysis sampled from the irradiated plate fuel. This research has conducted separation and analysis of the 137Cs contained in irradiated U3Si2/Al plate by chloroplatinate precipitation method. This method requires that the sample has to be made free from elements that may interfere with the precipitation process. The separation is done by precipitation of 137Cs isotope in the form of Cs2PtCl6. The precipitation process uses CsNO3 as non-active carrier with varied weight of 0.0263; 0.0501; 0.0754; 0.1036 ; 0.2064; 0.3020, and 0.4017 g. The CsNO3 carrier is added in order to obtain more ammount of precipitate of Cs in the form of Cs2PtCl6 because CsNO3 has similar chemical properties with 137Cs in uranyl nitrate solution. The 137Cs isotope is coprecipitated in Cs2PtCl6, and γ-spectrometry is used in the determination of the content of 137Cs in Cs2PtCl6 precipitate. The separation results show that addition of 0,1036 g CsNO3 has recovered 0.000328 g/g-sample of 137Cs from 0.000465 g/g-sample in irradiated U3Si2/Al solution, or a recovery of 70.4753%. Recovery value by this method is still lower when compared to other 137Cs separation methods due to longer steps of separation process, which may cause many errors in the sample preparation process.
PEMBUATAN STANDAR CESIUM DARI LARUTAN PEB U3Si2/Al PASCA IRADIASI DENSITAS 2,96 gU/cm3 DENGAN METODE PENGENDAPAN CsClO4 Aslina Br. Ginting; Boybul Boybul; Arif Nugroho; Yanlinastuti Yanlinastuti; Noviarty Noviarty; Gatot Wurdiyanto; Hermawan Chandra
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 25 No. 2 (2019): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2019.25.2.5457

Abstract

A considerable amount of irradiated nuclear fuel solutions exists in the hot cell area of Radiometallurgy Instalation (IRM). These solutions were generated from sampling activities for burnup test. The solutions cannot be disposed due to the present of 137Cs isotope and other heavy elements that have a long half time, but the solutions can be used as a secondary source of 137Cs standard for analysis purposes. Post-irradiation fuel analysis is always conducted by a valid method and with a calibrated spectrometer-γ. The standard used in the calibration of spectrometer-γ energy or activity is 137Cs isotope. There has been some restriction in the use of spectrometer-γ because spectrometer-γ calibration cannot be performed routinely due to the unavailability of standard sources. The availability of 137Cs isotope for R&D is still dependent on abroad suppliers. Therefore, in this research, PTBBN and PTKMR aim to develop a secondary standard source of 137Cs isotope with 10330 ± 411 Bq activity. The standard source was obtained from a solution of 137Cs separated from U3Si2/Al irradiated fuel. The separation was done by precipitation method with CsNO3 and HClO4 as the carrier. The result of the separation is 137CsClO4 precipitate, dried and weighed for obtaining greater activity and measured with a spectrometer-γ. The dried precipitate 137CsClO4 was subsequently packed as closed standard source (shield source). This standard sourced was certified by PTKMR as secondary standard isotope of 137Cs and is ready to be used for energy calibration of spectrometer-γ.
PEMISAHAN CESIUM DALAM PEB U3Si2/Al PASCA IRADIASI DENGAN METODE KOLOM PENUKAR KATION MENGGUNAKAN RESIN DOWEX Arif Nugroho; Dian Anggraini; Boybul Boybul; Sutri Indaryati; Rosika Kriswarini; Aslina Br. Ginting
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 24 No. 2 (2018): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2018.24.2.4306

Abstract

The burn up calculations of nuclear fuel by destruction method can be determined from the analysis of 137Cs isotope, as fission product. For this reason, the separation of 137Cs isotopes from uranium in irradiated fuel element plates of U3Si2/Al (PEB) needs to be done. The separation of 137Cs was done by using cation exchange column method with Dowex resin with weight variation of 1; 2; 3; 4; 5 and 6 g. This study aims to determine the content of 137Cs in irradiated fuel element plates of U3Si2/Al (PEB) using the cation exchange column method with Dowex resin to be compared with the result of 137Cs separation by cation exchange column method using Lampung zeolite and CsClO4 precipitation method. The irradiated fuel element plates of U3Si2/Al (PEB) PEB U3Si2/Al with a density of 2.96 gU/cm3 from the middle part of RI-SIE2 code and side plate 20 IDA 0045 was taken with weight 0.1103 g and dissolved with HCl 6N and HNO3 6N to obtain uranil nitrate solution. The U3Si2/Al post irradiated solution was 150 μL was added with 2 mL aquadest and added with Cs carrier 20 μL and 1 mL HCl 12 M. The solution mixture was used as feed into the anion exchange column (first column) containing the R-Cl resin –with the wight variation about 1; 2; 3; 4; 5 and 6 g. The effluent from the anion exchange column was introduced into the cation exchange column (second column) which contained R-NH4+ resin with weight variation of 1; 2; 3; 4; 5 and 6 g. The bounded 137Cs isotope in R-NH4+ resin in the column was being eluted using 1 M HCl of 15 mL and being vaporized until the volume reach ± 2 mL. The quantity of the 137Cs isotope in the effluent was measured by using a gamma spectrometer with a counting time of 500 s. The 137Cs isotope content in irradiated fuel element plates of U3Si2/Al with the density 2.96 gU/cm3is 0.000445 g/gPEB and the parameter of separation 137Cs with cation exchange column method using Dowex resin weighing 2 g with recovery is 98.67%. The result of separation of 137Cs by cation exchange column method is not much different from the result of separation 137Cs by cation exchange method and CsClO4 precipitation method. The 137Cs obtained can then be used for burn up calculations.
PENGARUH PENAMBAHAN ION SULFAT TERHADAP REKOVERI PEMISAHAN URANIUM MENGGUNAKAN METODE KOLOM PENUKAR ANION Boybul Boybul; Yanlinastuti Yanlinastuti; Dian Anggraini; Aslina Br. Ginting; Arif Nugroho; Rosika Kriswarini
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 23 No. 3 (2017): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2017.23.3.3679

Abstract

In the previous research, it was observed that the recovery of uranium separation by anion exchange column method with HCl 12 N solvent was 68.2137 %. The recovery can be increased by optimizing the uranium separation parameters by the use of HCl and Na2SO4 solvent mixture. A 500 μL uranyl nitrate standard solution was used as feed with varied HCl concentration of 6 N, 9 N, 12 N and varied Na2SO4 concentration of 500, 1000, 1500, 2000, 2500 and 3500 ppm as reagent solution. In the anion exchange process, uranium was bound by the resin to form [UO2(SO4)3]4- and [UO2(SO4)2]2 complex compounds, and these complexes were eluted with 15 mL of 0.15 N HCl dilute solution. The eluate was heated to nearly dried condition and 1 mL of HCl concentrated solution was added for electrodeposition process. The uranium deposited on stainless steel planset, as the result of electrodeposition process, was analyzed with alpha spectrometer. It was observed that the largest 235U content was found in 9M of HCl solvent and 1500 ppm of Na2SO4 with 95.7124 % recovery. Therefore, the concentration value of HCl of 9 N and 1500 ppm of Na2SO4 were subsequently applied to the uranium separation of irradiated U3Si2/Al fuel element plate. An amount of 500 μL supernatant of U3Si2/Al specimen taken from the top, middle and bottom position of fuel element plate (FEP) were put into an anion exchange column containing 1 g of Dowex-Cl resin. The results of the separation process were 235U isotope identified according to their position in the irradiated U3Si2/Al fuel element plate i.e. top, middle, and bottom. It was found that the recovery values were 13265.7866 μg/gFEP; 6923.9248 μg/gFEP; and 12332.4175 μg/gFEP representing their position of top, middle and bottom respectively. It is concluded that the use of 9M of HCl solvent and 1500 ppm of Na2SO4 by anion exchange column method can improve uranium separation recovery from 68.2137 % to 95.7124 %.
PENGARUH PELARUT ORGANIK PADA PROSES PERTUKARAN ANION DALAM PEMISAHAN URANIUM DARI LARUTAN PEB U3Si2/Al PASCA IRADIASI Dian Anggraini; Boybul Boybul; Yanlinastuti Yanlinastuti; Arif Nugroho; Rosika Kriswarini; Aslina Br. Ginting
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 23 No. 2 (2017): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2017.23.2.3576

Abstract

Separation method of uranium from nuclear fuel solutions was developed to improve the quality of uranium-based analysis of post-irradiation nuclear fuel. The aim of this study was to determine the effect of organic solvent on the anion exchange process on the recovery of U from U3Si2/Al fuel solution post-irradiated. The organic solvent, in this case methanol, contained in solvent medium in the anion exchange column may be possible to increase the resin sorption of the uranium. The materials used are standard solution of uranil nitrat and supernatant solution of Cs separation process from the fuel solution. The uranium separation method from U3Si2/Al post irradiated fuel solution uses two columns of anion exchanger with two stages. The first column uses Dowex 1x8-Cl Dowex resin. Parameters varied in the first column are HNO3 concentrations ranging from 1M; 2M; 3M and 4M. The parameters variation in the second column is the ratio of HCl/methanol volume of 30:70 %; 20:80 % and 10:90 %. The result obtained a maximum U recovery of 90,68 % with feed solution composition in the first column containing 3 % HNO3 and methanol by 50 %volume, while in the second column with 6M HCl composition with methanol in 10 %:90 % ratio. In these conditions obtained uranium content in a solution of the middle PEB U3Si2/Al TMU 2.96 g/cm3 piece of 0.4725 μg.
ANALISIS KANDUNGAN CESIUM DAN URANIUM DALAM BAHAN BAKAR U3Si2/Al PASCA IRADIASI Boybul Boybul; Yanlinastuti Yanlinastuti; Arif Nugroho; Dian Anggraini; Rosika Kriswarini; Aslina Br. Ginting
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 23 No. 2 (2017): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2017.23.2.3568

Abstract

Separation of fission product isotopes of 137Cs and 235U has been done to determine content of 137Cs and 235U in irradiated U3Si2/Al fuel plate of 2.96 gU/cm3 density. The initial step in the determination of 137Cs and 235U content is sample cutting process. The cutting position was determined at the top middle and bottom part of the plate by an amount of 0.095 g; 0.1103 g and 0.1441g for each respective position. Each sample was dissolved in 25 mL of HNO3 6N dan HCl 6N to obtain irradiated U3Si2/Al solution. Separation was carried out by cation exchange and precipitation methods. The separation of 137Cs was done by pipetting 150 µL of the irradiated U3Si2/Al sample solution and adding it to 1000 mg of Lampung zeolite, while the separation by precipitation method was done by adding 700 mg of CsNO3 powder as carrier and HClO4 to the U3Si2/Al sample solution. In the cation exchange method, 137Cs would be bound by zeolite in the solid phase in the form of 137Cs-zeolite and uranium would stay in the liquid phase or supernatant. The precipitation was done in an ice bath at -4 oC to obtain 137CsClO4 precipitate. The effluent leaving the column was subjected to electrodeposition process for 235U content measurement with α-spectrometer. The 137Cs content obtained by cation exchange was 401.0335 µg/g FP (FP = irradiated fuel plate); 451.1094 µg/g FP and 343.9651 µg/g FP for each respective sample position by 99 % recovery, while the 137Cs content obtained by precipitation method was 393.4581 µg/g FP; 452.0525 µg/g FP and 330.7839 µg/g FP for each respective sample position by 98 % recovery. The 235U content was found to be 45208 µg/g FP; 50896 µg/g FP and 44336 µg/g FP for each respective sample position by 68 % recovery.
PEMISAHAN DAN ANALISIS 137Cs DARI LARUTAN PELAT ELEMEN BAKAR U-7%Mo/Al Dian Anggraini; Noviarty Noviarty; Yanlinastuti Yanlinastuti; Aslina Br. Ginting; Rosika Kriswarini; Arif Nugroho; Boybul Boybul
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 22 No. 3 (2016): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2016.22.3.3183

Abstract

The aim of this research is to get a valid method of separating cesium from U-7Mo/Al fuel plate solution through determination of parameter of method (accuracy, precision, and recovery). Precipitation method and cation exchange method that are used refer to standard ASTM 690-000 and research result of U3Si2/Al. Parameter method determination has been done by using 150 μL sample (U-7%Mo/Al fuel plate solution, 50 μL of standard solution in 2 mL of HCl 0,1 N. The sample solution was undergone precipitation process by using HClO4 concentrated and 225 mg of CsNO3 as carrier in temperature 0oC for an hour, while exchange cation process was done by using 400 mg of resin zeolite Lampung. The analysis of 137Cs in CsClO4 and 137Cs - zeolite was done by gamma spectrometer. Determination of recovery method was done by comparing count value of 137Cs before and after separation process. Recovery of precipitation method was obtained 95.56 % with accuracy and precision measurement of 0.375 % and 1.875 % respectively, while recovery of cation exchange method obtained 26.73 %. To sum up, the results show that precipitation method better than exchange cation method for separation 137Cs from U-7Mo/Al fuel plate solution.
PERILAKU KOROSI BAJA KARBON RENDAH PIPA PENDINGIN SEKUNDER REAKTOR DALAM INHIBITOR ZINK FOSFAT Rosika Kriswarini; Mohammad Khotib; Andon Insani; Komar Sutriah; Noviarty; Arif Nugroho; Enung Nurlia
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 30 No. 1 (2024): Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/Urania.2024.8675

Abstract

Carbon steel, one of the fuction in nuclear industry is used as a material for the cooling pipe structure of nuclear reactor operating systems. In use, the pipe is susceptible to corrosion due to contact with cooling water. Inhibitors of zinc phosphate solution derived from a mixture of zinc chloride and phosphoric acid with concentration variations of 25, 35, 50, 75 and 100 ppm in 0.1% NaCl are used as materials to study the effect of corrosion rates of carbon steel. Electrochemical methods are helpful for observing the corrosion behavior of carbon steel in zinc phosphate media. Methods include Open Circuit Potential (OCP) for 600 seconds, Electrochemical Impedance Spectroscopy (EIS) in the frequency range of 105 Hz to 0.01 Hz and Potentiodynamic Plot (PDP) in the voltage range of -1 Volt to 1 Volt using potentiostat. To support the results of corrosion tests, morphological observations were carried out using SEM, chemical composition of substrat using XRF and C/S Analyzer and zinc phosphate solution content using AAS, UV-Vis and FTIR. The results obtained show that at a concentration of 35 ppm, the corrosion rate gives a lower value than at other concentrations. The corrosion rate is 11.7 mpy
MODEL SIMULATION OF THE EFFECT OF ZINC PHOSPHATE INHIBITOR ON CORROSION RATE OF SECONDARY COOLING PIPE FOR PRESSURIZED WATER REACTOR USING PREDICTOR-CORRECTOR METHOD Fajar Al Afghani; Maman Kartaman Ajiriyanto; Rosika Kriswarini; Arif Nugroho; Juan Carlos Sihotang; Ely Nurlaily; Anditania Sari Dwi Putri
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 30 No. 1 (2024): Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/Urania.2024.8677

Abstract

Corrosion is one of the unavoidable problems in nuclear reactor cooling systems. Secondary Cooling Pipe Multi-Purpose Reactor G.A Siwabessy (MPR-GAS) based on low carbon steel is very easy to oxidize because it is an open circulation cooling system. Zinc-phosphate inhibitor (ZnPO4) is one of the inhibitors used to inhibit the corrosion reaction that occurs between the low carbon steel cooling pipe and the cooling water environment. The research has been carried out on numerical calculations to find a solution for the corrosion rate model of steel with and without an inhibitor by the Predictor-corrector method. The simulation results show that the effect of ZnPO4 inhibitor on the corrosion rate of steel is seen as a relationship between inhibitor concentration and stable time, if the inhibitor concentration increases, the stable time will also increase. The rate of corrosion that occurs (reducing the concentration of corroded product). Therefore, the recommended inhibitor concentration value is 0.9% for models in 0.1 M HCL medium. This concentration is the most appropriate concentration to slow down the corrosion rate most minimal.
PENGUKURAN BERAT RADIONUKLIDA 137Cs DALAM LARUTAN PELAT ELEMEN BAKAR U3Si2/Al DENSITAS 4,8 gU/cm3 PASCA IRADIASI DENGAN METODE KOLOM KROMATOGRAFI Boybul; Yanlinastuti; Erlina Noerpitasari; Juan Carlos Sihotang; Helmi Fauzi Rahmatullah; Arif Nugroho; Mohammad Sukron Fajrin Husein; Rohmad Sigit; Aslina Br Ginting; Susilo WIdodo
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 30 No. 1 (2024): Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/urania.2024.8678

Abstract

The burn up value of the fuel is one of the parameters that must be known in the post-irradiation examination. The determination of burn up aims to determine the performance of U3Si2/Al fuel after being used in the reactor. One of the isotops that can be used as an indicator of burn up is 137Cs because it has a long half-life (T1/2) of 30.17 years with a fission yield of 6.26%. Therefore, in this study, a separation was carried out to determine the amount of 137Cs in the U3Si2/Al fuel solution post irradiation using the cation exchange column method using zeolit from Lampung along with its recovery rate. The solution of irradiated U3Si2/Al fuel from Top (T), Middle (M), and Bottom (B) position, was each pipetted in a duplicate manner (duplo) in an amount of 50 µL and added with 2 mL of 0.1 M HNO3. The solutions were then measured activity using a gamma spectrometer to obtain the initial weight of 137Cs radionuclide. The solution was then inserted into a chromatography column containing 700 mg of zeolit Lampung and allowed to flow under vacuum condition. The separation results showed that 137Cs was bound to the zeolit in the form of 137Cs-zeolit solid phase, while other isotops remained in the liquid phase. The solid 137Cs-zeolit and 137Cs in the supernatant were then measured with a gamma spectrometer to determine the weight of 137Cs bound to the zeolit. The measurement results showed that the average initial weight of 137Cs (before separation) were 7.49 × 10-3 µg/gFEP and dan 6.97 × 10-3 µg/gFEP for T1 and T2 from top section, 10.50 × 10-3 µg/gFEP for M1 from Middle section, and dan 8.43 × 10-3 µg/gFEP and 8.76 × 10-3 µg/gFEP for B1 and B2 from Bottom section, respectively. After separation, the average weight of 137Cs were 7.43 × 10-3 µg/gFEP and 6.82 × 10-3 µg/gFEP for T1 and T2, 10.10 × 10-3 µg/gFEP for M1, and 8.32 × 10-3 µg/gFEP and 8.41 × 10-3 µg/gFEP for B1 and B2, respectively. From the weight of 137Cs before and after separation, the average separation recovery with the cation exchange chromatography column method using zeolit was obtained at 97.748%. This recovery value indicates that zeolit Lampung is highly selective for absorbing 137Cs in the solution of irradiated U3Si2/Al fuel.