Claim Missing Document
Check
Articles

Found 10 Documents
Search

MENGGALI POTENSI ALIRAN AIR SUNGAI SEBAGAI SUMBER TENAGA PEMBANGKIT LISTRIK MIKROHIDRO; STUDI KASUS : SUNGAI KALI MANGGIS DI WILAYAH MAGELANG Nisworo, Sapto; Setyowati, Endang
JURNAL TEKNOLOGI TECHNOSCIENTIA Academia Ista Vol 12 No 02 Februari 2008
Publisher : Lembaga Penelitian & Pengabdian Kepada Masyarakat (LPPM), IST AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (70.039 KB) | DOI: 10.34151/technoscientia.v0i0.2015

Abstract

People are becoming more dependent on electric energy in their daily life. Waterfall is one potential primary source of energy. Kali Manggis river has to potential for a PLTM (Pembangkit Listrik Tenaga Mikrohidro) system used waterfall method. The research was to explore this potential quantitatively.This research used positivistic method with a hypothesis that Kali Manggis river is good potential of energy. Discharge of water and the height of waterfall were measured and the analysis of data will give quantity energy.The findings show that Kali Manggis river was a lot of power for electric energy. The electrical energy force in the Kali Manggis river was 1.503,8222179 kwh.
MENGGALI POTENSI ALIRAN AIR SUNGAI SEBAGAI SUMBER TENAGA PEMBANGKIT LISTRIK MIKROHIDRO; STUDI KASUS : SUNGAI KALI MANGGIS DI WILAYAH MAGELANG Nisworo, Sapto; Setyowati, Endang
JURNAL TEKNOLOGI TECHNOSCIENTIA Academia Ista Vol 12 No 02 Februari 2008
Publisher : Lembaga Penelitian & Pengabdian Kepada Masyarakat (LPPM), IST AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.34151/technoscientia.v0i0.2015

Abstract

People are becoming more dependent on electric energy in their daily life. Waterfall is one potential primary source of energy. Kali Manggis river has to potential for a PLTM (Pembangkit Listrik Tenaga Mikrohidro) system used waterfall method. The research was to explore this potential quantitatively.This research used positivistic method with a hypothesis that Kali Manggis river is good potential of energy. Discharge of water and the height of waterfall were measured and the analysis of data will give quantity energy.The findings show that Kali Manggis river was a lot of power for electric energy. The electrical energy force in the Kali Manggis river was 1.503,8222179 kwh.
Analisis Implementasi Rumah Mandiri Energi PLTS Atap On Grid Mardandi, Brian Taufik; Nisworo, Sapto; Windarta, Jaka
Jurnal Profesi Insinyur Indonesia Vol 1, No 8 (2023): JPII: Nopember -Desember 2023
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jpii.2023.23860

Abstract

Artikel ini menyajikan analisis implementasi rumah energi mandiri dengan sistem fotovoltaik surya (PV) atap on-grid. Meningkatnya permintaan untuk solusi energi terbarukan dan keinginan untuk kemandirian energi telah menyebabkan peningkatan adopsi sistem PV surya atap. Studi ini meneliti kepraktisan dan efektivitas mengintegrasikan sistem PV surya atap ke dalam bangunan tempat tinggal, secara khusus berfokus pada konfigurasi on-grid. Studi ini menunjukkan potensi rumah tangga untuk menghasilkan energi bersih, mengurangi ketergantungan pada jaringan listrik, dan mencapai penghematan biaya. Studi ini menyoroti pentingnya desain sistem yang tepat, pemasangan yang benar, dan pemantauan berkelanjutan untuk memastikan kinerja yang optimal dan memaksimalkan manfaat sistem. Secara keseluruhan, artikel ini berkontribusi pada pemahaman tentang implementasi sistem PV surya atap on-grid di bangunan tempat tinggal. Artikel ini berfungsi sebagai sumber daya yang berharga bagi pemilik rumah, pembuat kebijakan, dan profesional energi yang ingin memanfaatkan potensi sumber energi terbarukan dan mempromosikan kehidupan yang berkelanjutan. Kata kunci: rumah energi mandiri; Pembangkit Listrik Tenaga Surya; penghematan biaya listrik 
Sekutu Emitor Dua Tahap dan Resistor Daya sebagai Detektor Arus pada Sistem Proteksi Arus Analog Novianto, Dwi; Isnanto, R Rizal; Nisworo, Sapto
Jurnal Profesi Insinyur Indonesia Vol 2, No 2 (2024): JPII
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jpii.2024.24264

Abstract

Fokus penelitian ini adalah sistem proteksi Catu Daya Meja tegangan ganda yang digunakan untuk melakukan sebuah percobaan pada suatu proyek penelitian ataupun praktikum pada proses pembelajaran. Catu Daya Meja yang dijual di pasaran rata-rata mampu menyalurkan arus 3A hingga 10A karena penggunaannya yang luas. Kemampuan menyalurkan arus yang cukup tinggi harus disertai dengan sistem proteksi arus. Sistem proteksi arus dapat dirancang secara digital ataupun analog. Keduanya mempunai kelemahan dan kelebihannya masing-masing. Namun sistem proteksi arus analog lebih populer karena apabila terjadi kerusakan, pengguna dapat memperbaikinya dengan mudah karena tidak melibatkan proses pengkodingan. Salah satu sensor yang populer dan mudah ditemukan di pasaran serta handal adalah resistor daya 0,1Ω/100W yang dirangkai secara seri paralel. Tegangan yang dihasilkan dari resistor tersebut digunakan untuk membias rangkaian sekutu emitor dua tahap dengan transistor 2N3904. Rangkaian sekutu emitor tahap ke-dua digunakan sebagai saklar untuk mengaktikan relay LY2l4. Karena resistor daya yang digunakan mempunyai nilai hambatan kecil namun dipergunakan untuk memproteksi arus yang besar, maka perhitungan pada proses pemilihan nilai komponen harus diperhatikan. Perhitungan tersebut akan dibahas pada artikel ini secara terperinci. Selain perhitungan, penentuan lebar jalur PCB juga harus sesuai standar. Standar yang akan digunakan adalah Standar IPC. Dari perhitungan diperoleh sistem proteksi handal yang dapat menyalurkan arus maksimal 10A dengan catu daya sistem antara 26V hingga 60V. Selain itu, komponen yang dipilih adalah komponen yang mudah ditemukan di pasaran sehingga mempermudah perawatan jika terjadi kerusakan. Kata kunci: proteksi, arus, standar, IPC
A Review on Digital Microscopic Images for Plasmodium Parasite Detection Nisworo, Sapto; Prananda, Alifia Revan
TEKNIK Vol. 44, No. 3 (2023): December 2023
Publisher : Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/teknik.v44i3.53990

Abstract

Indonesia is one of the regions that contribute to the increasing number of malaria cases. In 2019, more than 250 million malaria cases were found in Indonesia. This phenomenon is caused by several factors, including the examination procedure. In Indonesia, the digital microscopic examination has become the gold standard procedure in detecting and diagnosing malaria, whereas this procedure requires considerable expertise. Hence, the rapid examination is difficult to ensure. In order to overcome this problem, several methods of malaria detection have been proposed with a different approach. Image processing and computer vision techniques have become a powerful approach in the development of early detection systems called computer-aided detection (CADe) and computer-aided diagnosis (CADx). Several previous findings reported their contributions in detecting Plasmodium parasites using image processing and computer vision. Recently, artificial intelligence, including machine learning and deep learning, also offered outstanding results in detecting the Plasmodium parasite. This paper aims to present a scientific review of recent image processing and computer vision applications for the development of CADe or CADx in order to assist the doctor in doing rapid detection and diagnosis.
Assessing transformer health through analysis of dissolved gases in cooling oil Nisworo, Sapto; Hasibuan, Arnawan; Isa, Muzamir; Nrartha, I Made Ari; Jannah, Misbahul; Muhammad, Muhammad
International Journal of Applied Power Engineering (IJAPE) Vol 13, No 4: December 2024
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v13.i4.pp1014-1020

Abstract

Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.
Performance of single axis tracker technology and automatic battery monitoring in solar hybrid systems Satria, Habib; Nisworo, Sapto; Windarta, Jaka; B. Y. Syah, Rahmad
Bulletin of Electrical Engineering and Informatics Vol 12, No 6: December 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v12i6.5506

Abstract

Utilization of elevation angles and azimuth angles is a very important part in maximizing solar energy into electrical energy in photovoltaic (PV). One way to maximize PV power output is to design a single axis tracker system and take into account the azimuth and elevation angles of the sun using the sun position calculator application. The single axis tracker system is set based on the position of the angle of inclination of the surface of the PV 45°, then the angle of 90° and the angle of inclination of 135°. The test results show that the single axis tracker PV system design can work based on the angle settings that have been programmed. Then the use of a battery control system to support the PV reliability system automatically cuts off electricity when the battery voltage drops below 12 V during cloudy weather conditions and excessive battery usage. The integration of the PZEM-017 module with the battery will support monitoring of battery power usage in real time. PV energy data conversion performance uses single axis tracker technology for maximum power reaching 631.72 Watt DC at 12.00 pm and the lowest power reaching 56.02 Watt DC at 6.00 pm.
Analisis Fluktuasi Radiasi Matahari dan Implikasinya Terhadap Penempatan PLTS Salile, Ahmad Yusuf; Nisworo, Sapto; Sumardi, Sumardi
Jurnal Profesi Insinyur Indonesia Vol 2, No 6 (2024): JPII:
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jpii.2024.24596

Abstract

Radiasi matahari di Indonesia sangat berfluktuasi. Hal ini berdampak langsung pada keluaran daya dari PLTS yang pada gilirannya dapat menyebabkan masalah operasional seperti fluktuasi frekuensi pada jaringan listrik. Untuk mengatasi hal ini, diusulkan pengukuran dan analisis fluktuasi radiasi matahari secara independen di berbagai lokasi, serta membandingkannya dengan pengukuran secara koinsiden (gabungan beberapa lokasi). Hipotesis menyatakan bahwa semakin banyak titik pengukuran secara koinsiden akan menghasilkan persentase fluktuasi yang lebih kecil. Dengan memahami data statistik mengenai fluktuasi radiasi matahari, para insinyur dapat merencanakan kapasitas sistem PLTS secara strategis dan mengoptimalkan penempatannya. Informasi ini memungkinkan pemanfaatan energi surya yang efisien sambil tetap menjaga stabilitas sistem. Selain itu, temuan penelitian ini dapat membuka peluang untuk investigasi lebih lanjut mengenai sifat intermiten sistem PLTS. Pada akhirnya, penelitian ini secara tidak langsung berkontribusi pada transisi menuju sumber energi yang lebih bersih dan berkelanjutan. Kata kunci: radiasi matahari, fluktuasi, statistik, PLTS, Pulau Jawa
Analisis Saluran Kabel Tanah pada Proyek Pembangunan Saluran Kabel Tegangan Tinggi 150kV Kawasan Industri Kapasitas 170MVA Sepanjang 6,5 kmr Kartojo, Ismail Hartanto; Triwiyatno, Aris; Nisworo, Sapto
Jurnal Profesi Insinyur Indonesia Vol 2, No 4 (2024): JPII
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jpii.2024.24584

Abstract

Karya ilmiah ini disusun untuk melakukan analisis pembangunan transmisi berkapasitas 170 MVA dan panjang 6,5 kmr guna memenuhi kebutuhan pelanggan tegangan tinggi di kawasan industri. Pelanggan akan disuplai dari dua sub sistem yang berbeda dan pasokan listrik mulai digunakan dalam jangka waktu satu tahun. Sehubungan jangka waktu konstruksi yang singkat, maka pasokan listrik tahap satu akan disuplai melalui SKTT. Agar pembangunan SKTT dilaksanakan secara tepat mutu, biaya dan waktu maka dilakukan analisis untuk menentukan saluran kabel tanah yang akan digunakan meliputi jenis dan ukuran penampang kabel, metode penggelaran kabel, proteksi mekanis kabel serta memenuhi aturan yang berlaku dengan mempertimbangkan perkembangan teknologi kabel tanah. Berdasarkan hasil analisis yang dilakukan maka pembangunan SKTT menggunakan kabel konduktor aluminium 2000 mm2 dengan metallic sheath corrugated aluminium sheath. Sesuai hasil perhitungan KHA, pada kedalaman 7 meter dengan konfigurasi trefoil dan metode HDD, saluran kabel dapat mengaliri arus senilai 760 A atau setara 197 MVA. Kata kunci: Analisis SKTT, kawasan industri, KHA, trefoil, HDD, corrugated aluminium sheath
Simulasi Perbaikan Harmonik pada Bangunan Pabrik menggunakan Pasif Filter Wahyu Endah Palupi; Sapto Nisworo; Deria Pravitasari
ULIL ALBAB : Jurnal Ilmiah Multidisiplin Vol. 2 No. 3: Februari 2023
Publisher : CV. Ulil Albab Corp

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56799/jim.v2i3.1368

Abstract

Kualitas daya listrik merujuk pada tingkat keandalan suatu sistem kelistrikan terhadap standar yang ditetapkan. Tingkat harmonik arus dan tegangan dalam suatu sistem kelistrikan harus memenuhi standar yang disyaratkan dalam IEEE Std 519-2014. Hal ini dikarenakan efek harmonik akan menyebabkan rugi-rugi daya yang tinggi, pemanasan berlebih pada sistem, dan rendahnya faktor daya pada sistem. Pada penelitian ini dilakukan analisis kualitas daya listrik dengan memitigasi harmonik di LPK Abhinaya Paramarthika Dharma sebagai upaya yang dilakukan untuk memperbaiki sistem tenaga listrik. Hasil pengukuran kualitas daya listrik di LPK Abhinaya Paramarthika Dharma diperoleh beberapa harmonik arus yang tidak sesuai standar. Perancangan filter dilakukan untuk mitigasi harmonik agar nilai Total Distorsi Harmonik (THDi) dapat turun sesuai standar dengan membuat simulasi pada software PSIM. Berdasarkan simulasi nilai THDi dengan filter harmonik dapat menurunkan THDi dari 33,91% menjadi 5,77% pada frekuensi 150Hz.