Articles
Deviation Analysis of Temperature Distribution in Copper Bar Heat Conduction Process Experiments Against Numerical Calculations
Ratu Fenny Muldiani;
Kunlestiowati Hadiningrum;
Defrianto Pratama
KONSTAN - JURNAL FISIKA DAN PENDIDIKAN FISIKA Vol 7 No 02 (2022): KONSTAN (Jurnal Fisika dan Pendidikan Fisika)
Publisher : Universitas Islam Negeri (UIN) Mataram
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.20414/konstan.v7i02.190
In the process of heat transfer by conduction, besides the quantities in the form of surface area, length or thickness of the rod, and the temperature difference between the ends of the rod and the value of the thermal conductivity, other factors also affect the rate of heat transfer to the rod, one of which is environmental factors. As long as heat flows from the high to the low temperature, the temperature decrease is not uniform at any time interval. This is a sign of the influence of the ambient temperature for each part of the material. Temperature observations were carried out experimentally in an open environment in the laboratory and then compared with the results of numerical calculations as the ideal condition for the heat conduction process. The Boltzmann transport equation for the induction process on metal rods is solved using finite differences with an explicit method to obtain the temperature distribution. The results showed differences in the temperature distribution pattern of copper rods with numerical calculations and experiments. This difference is caused by the amount of heat released into the environment. The higher the temperature at the observation point, the greater the heat released into the atmosphere.
Improving Understanding of the Concept of the Effect of Temperature on Fluid Flow Characteristics Through Experimental Methods for Engineering Students
Kunlestiowati Hadiningrum;
Ratu Fenny Muldiani;
Defrianto Pratama
Jurnal Geliga Sains: Jurnal Pendidikan Fisika Vol 10, No 2 (2022)
Publisher : Program Studi Pendidikan Fisika FKIP Universitas Riau
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31258/jgs.10.2.144-153
This research is motivated by the high need for dynamic fluid concepts in the industrial world. to research the increased understanding of the concept of the influence of temperature on the characteristics of fluid flow which is part of the subject matter of fluid dynamics, an experimental module was prepared based on the optimization results of the appropriate physical quantities through testing of experimental instruments. The research aims to know the understanding the concept of the influence of temperature on the characteristics of fluid flow through experimental activities, to support the learning of dynamic fluid concepts for engineering students at the Bandung State Polytechnic. The research method uses quasi-experimental research, with experimental class learning treatment through theory and experimentation, while in the control class only through theory. To examine the effect of the experimental method on learning outcomes of conceptual understanding with 7 indicators using simple statistical analysis techniques. The results of the data analysis obtained an increase in understanding of the concept of the group of students who carried out experimental activities higher than the group of students who only received learning in theory class. The results of the normality test for the experimental class and control classes stated that the pre-test and post-test data were normally distributed. The results of the accumulated percentage of respondents' questionnaires, as many as 92.1% of respondents gave positive responses (strongly agreed and agreed) on quality and only 7.9% of respondents gave ordinary responses. Based on the average N-Gain, it was obtained that the experimental class had a greater N-Gain value than the control class, then based on the t-test, students' understanding of the concepts of the experimental class and the control class had a significant difference after being given treatment, it can be interpreted that the class that received experimental learning was more have a higher conceptual understanding.
Studi Awal Pengaruh Temperatur terhadap Karakteristik Aliran Fluida Pada Belokan Pipa 90° melalui Simulasi
Defrianto Pratama;
Kunlestiowati Hadiningrum;
Ratu Fenny Muldiani
Jurnal MIPA Vol. 11 No. 2 (2022)
Publisher : Universitas Sam Ratulangi
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35799/jm.v11i2.41826
Penelitian ini sebagai studi awal untuk mengetahui pengaruh temperatur fluida terhadap karakteristik aliran (laminar, transisi atau turbulen) dengan melihat perubahan tekanan, laju aliran dan bilangan Reynold pada belokan pipa. Aliran fluida (air) disimulasikan dengan software Ansys Fluent, kemudian didapatkan data perubahan tekanan, laju dan bilangan Reynold sepanjang pipa dengan belokan pipa 900. Hasil analisis data simulasi menunjukan bahwa setelah melewati belokan pipa 900, fluida dengan temperatur berbeda akan memiliki karakteristik aliran yang berbeda.Â
Analisis Model Persamaan Gas Nyata Pada Eksperimen Hukum Gay-Lussac Dan Boyle
Kunlestiawati Kunlestiawati;
Ratu Fenny Muldiani;
Defrianto Pratama
Science and Physics Education Journal (SPEJ Vol 7 No 1 (2023): SPEJ (Science and Physics Education Journal)
Publisher : Institut Penelitian Matematika, Komputer, Keperawatan, Pendidikan dan Ekonomi (IPM2KPE)
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31539/spej.v7i1.6869
Abstrak: Penelitian ini bertujuan untuk menganalisis model persamaan gas nyata pada eksperimen Hukum Gay-Lussac dan Boyle menggunakan metode pencocokan kurva. Metode yang digunakan melibatkan pengumpulan dan persiapan data eksperimental untuk analisis. Selanjutnya, persamaan gas ideal dan persamaan Van der Waals dihitung berdasarkan nilai tekanan, volume, dan suhu yang diberikan. Perbedaan antara data eksperimental dan hasil permodelan dianalisis menggunakan metode Regresi Linear, kemudian dihitung nilai Root Mean Square Error (RMSE) dan Koefisien Determinasi (R square). Dari analisis ini, ditemukan bahwa model gas Van der Waals memiliki kesesuaian yang lebih baik dengan data eksperimental Hukum Gay-Lussac dan Boyle. Hasil ini memberikan kontribusi penting dalam pemahaman tentang perilaku gas pada volume tetap dan suhu tetap. Efek interaksi antar molekul dan volume partikel gas tidak dapat diabaikan dalam model persamaan gas karena lebih sesuai dalam menggambarkan perilaku gas nyata. Kesimpulan ini menggarisbawahi pentingnya mempertimbangkan faktor-faktor ini dalam model persamaan gas untuk mendapatkan pemahaman yang lebih akurat tentang sifat gas. Kata Kunci: Persamaan Gas Nyata, Hukum Gay-Lussac, Hukum Boyle, Model Van der Waals
Perancangan Fin-tube Surface Cleaning System Untuk Pembersihan Air-Cooled Heat Exchanger
Ijlal Syaifullah;
Ratu Fenny Muldiani;
Teguh Sasono
Jurnal Mekanik Terapan Vol 4 No 2 (2023): Agustus 2023
Publisher : Politeknik Negeri Jakarta
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.32722/jmt.v4i2.5811
Maintenance cleaning of the outer surface of the fin-tube on air-cooled heat exchangers is essential to maintain optimal performance. Performance degradation occurs due to the accumulation of dust and impurities on the fin-tube surface, forming crusty deposits when exposed to water. Currently, manual cleaning using water spray takes 80 hours to cover the entire surface. To improve cleaning efficiency, an innovative design of a water flow system using pipes and nozzles was developed. The design was based on calculations using Bernoulli's law and simulations with Ansys Fluent. The design achieved sufficient working pressure and nozzle inlet velocity of 0,37 m/s for 648 nozzles to cover 18 fans. With this design, cleaning can be completed in 59 minutes, removing 2,40×10-8 kg of dust per nozzle, covering a cleaning area of 0,75 m2. The cleaning system is manually operated in monthly stages, requiring a total cleaning time of 17,70 hours. Effective cleaning is achieved by ensuring the fans are not in operation during the cleaning process.
Perancangan Ruang Bakar Circulating Fluidized Bed Sebagai Upaya Perbaikan Kinerja Pembangkitan Uap Di Pabrik Tekstil
Fadhila, Nisya Fitri;
Suprianti, Yanti;
Muldiani, Ratu Fenny
Prosiding Industrial Research Workshop and National Seminar Vol. 14 No. 1 (2023): Vol 14 (2023): Prosiding 14th Industrial Research Workshop and National Semina
Publisher : Politeknik Negeri Bandung
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35313/irwns.v14i1.5414
Chain grate stoker boiler di pabrik tekstil digunakan sebagai komponen untuk memenuhi kebutuhan uap di bagian produksi. Berdasarkan standar ASME ukuran batubara untuk boiler jenis ini yaitu kisaran 32 mm. Hal tersebut juga sudah diterapkan pada SOP pabrik, namun pada pelaksanaannya ukuran batubara tidak sesuai dengan SOP tersebut melainkan kurang dari ukuran yang sudah ditentukan, sehingga mengakibatkan penurunan efisiensi. Akibatnya pabrik menggunakan tambahan bahan bakar hidrogen hasil elektrolisa air sebagai upaya meningkatkan efisiensi. Namun efisiensi hanya dapat mencapai 68%, sedangkan efisiensi standar desain 75%. Ruang bakar dengan jenis circulating fluidized bed (CFB) memiliki karakteristik yaitu efisiensi pembakaran yang tinggi, lebih ramah lingkungan, fleksibilitas bahan bakar yang digunakan dan ukuran bahan bakar ≤ 6 mm. Ruang bakar CFB memanfaatkan kondisi partikel padatan tersuspensi udara pada suatu kecepatan tertentu hingga tidak terlihat perbedaan antara padatan dan aliran udara (fluidisasi). Perancangan ruang bakar dilakukan untuk kapasitas uap 3320.156 kW pada tekanan 7 bar. Dihasilkan ruang bakar yang lebih ringkas dengan dimensi yaitu lebar 0,657 m; panjang 1,314 m; tinggi 3,035 m dengan kecepatan fluidisasi 1,409 m/s dan efisiensi 82,713%. Menggunakan ruang bakar CFB dapat mereduksi penggunaan batubara menjadi 14,876 ton yang semula 18 ton per hari dan tidak dibutuhkan biaya untuk mesin elektrolisa.
Perancangan Fill Pack Cooling Tower Induced Draft Counterflow Pada Sistem Pendingin
Alisa Gandini Suganda;
Ratu Fenny Muldiani;
Budi Suharto
Prosiding Industrial Research Workshop and National Seminar Vol. 15 No. 1 (2024): Prosiding 15th Industrial Research Workshop and National Seminar (IRWNS)
Publisher : Politeknik Negeri Bandung
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35313/irwns.v15i1.6235
Cooling tower merupakan mesin penukar kalor antar dua fluida berupa air dan udara yang terjadi melalui penguapan dan perpindahan kalor secara konveksi. Proses pendinginan air pada cooling tower sangat bergantung pada fill pack sebagai tempat terjadinya perluasan area kontak air dengan udara dalam pertukaran panas. Cooling tower tersebut mengalami penurunan kinerja yang ditandai dengan menurunnya nilai cooling range. Hal ini dikarenakan karena adanya gangguan kerusakan dari fill pack sehingga aliran air yang keluar dari fill pack tidak merata dan temperatur air keluar yang dihasilkan masih tinggi. Salah satu upaya untuk mengatasi masalah tersebut, dilakukan rancangan bentuk fill pack menggunakan metode perhitungan NTU dan simulasi menggunakan software Aspen Plus dengan pendekatan absorber untuk menghasilkan temperatur air keluar. Hasil perancangan manual menghasilkan nilai cooling range sebesar 13,11 °C dan efektivitas sebesar 73,70%. Analisis kelayakan ekonomi diperoleh NPV sebesar Rp 1.585.436.176,44, Payback Period selama 11 bulan, dan IRR sebesar 75%.
Perancangan Plate Heat Excharger Untuk Pendingin Oli Penggerak MSV dan Control Valve Turbin PLTU
Adistia Prajani; Sri Wuryanti;
Ratu Fenny Muldiani
Prosiding Industrial Research Workshop and National Seminar Vol. 15 No. 1 (2024): Prosiding 15th Industrial Research Workshop and National Seminar (IRWNS)
Publisher : Politeknik Negeri Bandung
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35313/irwns.v15i1.6278
Pengoperasian katup pada turbin uap terutama main stop valve dan control valve, dibutuhkan oli sebagai fluida kerja yang mengalir untuk menggerakkan katup yang kemudian dialirkan ke control oil radiator untuk didinginkan. Penelitian ini membahas pada kondisi control oil radiator dalam mendinginkan oli yang kurang maksimal sehingga dibantu blower. Temperatur oli keluaran radiator sekarang sebesar sedangkan temperatur yang dianjurkan berdasarkan standar desain adalah . Salah satu cara untuk mengatasi masalah tersebut, dilakukan pemasangan Heat Exchanger tipe Plate untuk menggantikan control oil radiator, namun sebelumnya perlu merancang plate heat exchanger dengan menggunakan beberapa persamaan yang di validasi menggunakan software HTRI, kemudian dilakukan analisis hasil perbedaan antara perancangan manual dengan software HTRI. Hasil perancangan manual plate heat exchanger menghasilkan efektivitas sebesar 0,86. Syarat faktor kekotoran ≥ 0.00029 m².°C/W dan hasil perancangan adalah 0,00029167, serta syarat total pressure drop 68950 Pa dan hasil perancangan sebesar 66224,47 Pa.
PENERAPAN TEKNOLOGI FILTER ASAP UNTUK PENANGANAN GAS BUANG INSINERATOR PADA PENGOLAHAN SAMPAH
Muldiani, Ratu Feni;
Supriyanti, Yanti;
Gantina, Tina Mulya;
Koesoemah, Nita Hernita;
Pratama, Defrianto
Qardhul Hasan: Media Pengabdian kepada Masyarakat Vol. 10 No. 2 (2024): AGUSTUS
Publisher : Universitas Djuanda
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30997/qh.v10i2.10805
Pembakaran sampah dengan insinerator adalah metode umum dalam pengolahan sampah, tetapi menghasilkan emisi gas beracun yang berdampak buruk pada kesehatan dan lingkungan. Artikel ini membahas penggunaan teknologi filter asap untuk mengatasi masalah ini, dengan fokus pada Bank Sampah Cempaka 2 di Kabupaten Bandung Barat, Jawa Barat. Pelaksanaan pengabdian masyarakat selama 6 bulan dilakukan untuk mengimplementasikan sistem filter asap pada insinerator sampah. Sistem ini terdiri dari kotak quencher, filter karbon aktif, filter kapur tohor, dan bag filter. Hasilnya menunjukkan pengurangan emisi zat berbahaya dan partikel polutan udara. Pemberdayaan masyarakat dalam penggunaan dan pemeliharaan teknologi ini menjadi kunci keberhasilan, sambil mengidentifikasi potensi pengembangan lebih lanjut dalam pengelolaan sampah berkelanjutan. Saran untuk pengembangan selanjutnya adalah memantau kualitas udara di sekitar insinerator dan penelitian lanjutan untuk meningkatkan efisiensi teknologi filter asap.
The Effect of Capacitance on the Power Factor Value of Parallel RLC Circuits
Hadiningrum, Kunlestiowati;
Muldiani, Ratu Fenny;
Pratama, Defrianto
Jurnal Internasional Penelitian Teknologi Terapan Vol 1 No 2 (2020): October 2020
Publisher : Bandung State Polytechnic (Politeknik Negeri Bandung)
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35313/ijatr.v1i2.27
The power factor of the circuit is determined by the amount of pure resistance (R), self-inductance of the coil (L) and the capacitance of the capacitor (C). In this study, the measurement of the power factor value in a parallel RLC circuit was carried out through experimental testing and simulation with the value of C as the independent variable, while the values of R and L were fixed conditioned quantities. The purpose of this study was to determine the effect of capacitance on a parallel RLC circuit. One of the ways to improve the power factor value in a circuit is to install capacitive compensation using a capacitor. The relation between the power factor value and the capacitance and inductive reactance based on the experimental results and the simulation calculation results in the parallel RLC circuit both shows the same pattern with a relative uncertainty below 8%. The experimental results and simulation results both show that the power factor can be improved by using a right capacitance which is around the capacitance value when there is resonance in the circuit.