Claim Missing Document
Check
Articles

Unsupervised operating-regime and anomaly-candidate discovery in field photovoltaic measurements under incremental conductance MPPT Giovanni Dimas Prenata; Ahmad Ridho’i
Journal Geuthee of Engineering and Energy Vol 5, No 2 (2026): Journal Geuthee of Engineering and Energy
Publisher : Geuthèë Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52626/joge.v5i2.103

Abstract

Field photovoltaic measurements exhibit nonlinear environmental variation, heterogeneous module responses, and scarce verified fault labels, making fixed-threshold anomaly screening difficult. This study develops an unsupervised framework for operating-regime and anomaly-candidate discovery from a limited field dataset consisting of only 81 observations collected from three photovoltaic modules over five measurement days under Incremental Conductance MPPT. Ten environmental, temporal, electrical, and physics-related features were robustly normalized using the median and interquartile range and evaluated with K-Means, Fuzzy C-Means, Gaussian Mixture Model, DBSCAN, and K-Medoids. Model selection combined internal validity, minimum cluster-size constraints, repeated-run stability, ordinal-rank consensus, and composite anomaly scoring. Among the tested configurations, DBSCAN achieved the highest internal validity, with a Silhouette coefficient of 0.3751 and a Davies–Bouldin index of 0.8749, while K-Medoids showed high repeated-run stability (mean ARI=0.9655) and strong agreement with DBSCAN on non-noise observations (ARI=0.9301). The consensus identified Low, Moderate, and High operating regimes containing 16, 26, and 39 observations, respectively. The mutually exclusive anomaly categorization identified five high-score anomaly candidates, seven density-supported candidates, and 69 non-anomalous observations. Because verified fault labels and independent full I–V sweep references were unavailable, the selected observations are interpreted as candidates for targeted physical inspection rather than confirmed photovoltaic faults. The framework therefore provides a structured basis for exploratory screening of field photovoltaic measurements.
Identifikasi Parameter Ekuivalen Modul Fotovoltaik Berbasis Metaheuristik dari Pengukuran Lapangan Terbatas pada MPPT Incremental Conductance Giovanni Dimas Prenata; Ahmad Ridho’i
JUTEKS Vol 13 No 2 (2026): JuTEkS (Jurnal Teknik Elektro dan Sains)
Publisher : Program Studi Teknik Elektro Universitas Ibn Khaldun Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/juteks.v13i2.24833

Abstract

Ketersediaan parameter modul fotovoltaik yang akurat diperlukan untuk pemodelan, pemantauan kondisi, dan evaluasi kinerja sistem, tetapi informasi tersebut tidak selalu tersedia pada instalasi lapangan. Penelitian ini mengembangkan metode identifikasi parameter ekuivalen modul fotovoltaik menggunakan Algoritma Genetika, Particle Swarm Optimization, dan Grey Wolf Optimizer dari pengukuran lapangan terbatas pada sistem MPPT Incremental Conductance. Parameter yang diidentifikasi meliputi tegangan rangkaian terbuka, arus hubung singkat, tegangan dan arus titik daya maksimum pada kondisi standar, koefisien temperatur arus, koefisien temperatur tegangan, dan koefisien pengaruh iradiasi terhadap tegangan. Evaluasi menggunakan 81 observasi dari tiga modul fotovoltaik selama lima hari, validasi leave-one-day-out secara terpisah pada setiap modul, dan sepuluh running independen. Hasil identifikasi dinilai berdasarkan rekonstruksi  dan . Secara keseluruhan, PSO menghasilkan skor komposit terendah sebesar 11,2254, lebih baik 15,28% dibandingkan baseline median sebesar 13,2498. Pada modul P3 yang spesifikasinya tidak diketahui, GA memberikan skor komposit terbaik sebesar 17,1909, sedangkan PSO menghasilkan rekonstruksi daya terbaik dengan RMSE 11,3957 W, MAE 8,9664 W, dan R2 sebesar 0,7808. Parameter utama P3 yang diperoleh GA meliputi =20,2034±0,1702 V, =4,5315±0,2281 A, =16,2734±0,1371 V, =4,1168±0,2033 A, dan =66,9872±3,2084 W. Uji Wilcoxon menunjukkan bahwa perbedaan GA dan PSO pada P3 tidak signifikan, sedangkan keduanya secara signifikan lebih baik daripada GWO. Hasil penelitian menunjukkan bahwa parameter listrik utama dapat diidentifikasi secara konsisten, tetapi koefisien temperatur memiliki ketidakpastian lebih tinggi. Parameter yang diperoleh harus dipahami sebagai parameter ekuivalen hasil estimasi lapangan, bukan spesifikasi pasti dari pabrikan.