cover
Contact Name
Asmawati
Contact Email
lppm@unpal.ac.id
Phone
+6281271716289
Journal Mail Official
daenyyansuri@gmail.com
Editorial Address
Jl.Dharmapala No.1a, Bukit Besar, Palembang
Location
Kota palembang,
Sumatera selatan
INDONESIA
Jurnal Teknik Elektro
Published by Universitas Palembang
ISSN : 20892950     EISSN : 2715565X     DOI : https://doi.org/10.36546/jte.v11i2
Core Subject : Engineering,
Jurnal Teknik Elektro established in 2011 and ISSN Print 2089-2950, ISSN Online 2715-565X. It is a peer reviewed international journal to be of interest and use to all those concerned with research in various fields of, or closely related to Electrical or Electrical Engineering. The scope of the journal includes all theoretical findings and new experimental in the field of Electrical Engineering is Power Systems, Signal, System, and Electronics, Communication Systems, Informations Electronic Technology . Jurnal Teknik Elektro published by the Electrical Engineering Study Program Faculty of Engineering, University of Palembang and distributed twice a year. Jurnal Teknik Elektro is dedicated to researchers and academics who intend publishing research, scientific ideas, and other original scientific ideas. JTE is a published scientific, open access, peer reviewed, evidence-based journal by the Electrical Engineering Study Program, Faculty of Engineering, University of Palembang. Jurnal Teknik Elektro aims to provide a highly readable and valuable addition to the literature which will serve as an indispensable reference tool for years to come. The coverage of the journal includes all new theoretical and experimental findings in the fields of Engineering or any closely related fields. The journal also encourages the submission of critical review articles covering advances in recent research of such fields as well as technical notes.
Articles 113 Documents
ANALISA PERBANDINGAN DAYA GENERATOR TURBIN ANGIN 6 DAN 12 SUDU DARI PENGUKURAN DAN SIMULASI MATLAB SIMULINK DI LABORATORIUM TEKNIK LISTRIK POLITEKNIK NEGERI SRIWIJAYA Mutiar, Mutiar; Sunarhati, Marliyus
Jurnal Teknik Elektro Vol 12 No 1 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i1.649

Abstract

Daya generator yang di hasilkan dari turbin angin dipengaruhi daya turbin angin dan daya turbin angin dipengaruhi oleh kecepatan angin dan jumlah sudu. Dari hasil penelitian didapaat bahwa semakin besar kecepatan angin yang diberikan maka putaran turbin akan semakin tinggi sehingga daya listrik yang dihasilkan oleh generator juga akan semakin besar. Untuk turbin dengan jumlah sudu 6 dan 12 daya yang dihasilkan dari pengukuran 1,10 Watt dan 1,50 Watt, 1,89 Watt dan 2,89 Watt dihasilkan dari simulasi untuk kecepatan angin 7,0 m/ s.
EVALUASI PEMUTUS TENAGA DI GARDU INDUK GUMAWANG (STUDI KASUS PENYULANG CABE) Subianto, Subianto; Yani, Raden Ahmad; Juarsyah, Bayu
Jurnal Teknik Elektro Vol 12 No 1 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i1.650

Abstract

Banyak faktor-faktor yang dapat menyebabkan pemadaman listrik, salah satunya adalah gangguan pada saluran-saluran penyulang yang ada pada Gardu Induk di suatu daerah. Adapun gangguan-gangguan tersebut adalah gangguan eksternal dan gangguan internal. Gangguan eksternal berupa sambaran petir, atau karena adanya angin kencang, dan lain sebagainya. Sedangkan untuk gangguan internal adalah berupa adanya gangguan hubung singkat pada penyulang di gardu induk setempat. Penelitian yang dilakukan mempunyai tujuan yaitu dapat menentukan besar arus hubung singkat tiga phasa serta mengevaluasi sistem kapasitas pemutus tenaga yang terpasang pada Penyulang Cabe (out going) setelah transformator daya (incomming) pada Gardu Induk Gumawang. Ada beberapa metode yang dipakai guna memperoleh hasil yang mendekati akurasi adalah sebagai berikut Metode Studi Pustaka, Metode Deskriptif, dan Metode Wawancara. Dengan melakukan evaluasi terhadap gangguan di Gardu Induk Gumawang, khususnya pada penyulang cabe, maka di harapkan pemadaman listrik yang sering terjadi oleh masyarakat pedesaan di Belitang, akan dapat diatasi penyebabnya. Dari hasil perhitungan arus hubung singkat pada penyulang Cabe yaitu sebesar : 0,4236 kA dan daya hubung singkat pada penyulang Cabe yaitu sebesar : 14,674 MVA. Kapasitas pemutus tenaga yang terpasang pada sisi 20 kV pada Penyulang Cabe masih sesuai dengan ratingnya yaitu 866,025 MVA dan rating arus maksimum pemutus tenaga yaitu 25 kA, ini artinya Pemutus Tenaga yang terpasang masih mampu untuk melindungi sistem dari arus gangguan.
ANALISIS DETEKSI KEADAAN MINYAK TRANSFORMATOR DENGAN METODE GAS TERLARUT MENGGUNAKAN PERALATAN DISSOLVE GAS ANALISYS ( DGA) Darma, Surya; Mutiar, Mutiar
Jurnal Teknik Elektro Vol 12 No 1 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i1.651

Abstract

Kegagalan thermal pada transformator umumnya menghasilkan gas-gas berbahaya yang biasa dikenal sebagai fault gas. Transformator daya biasanya menggunakan minyak isolator yang fungsinya selain sebagai pendingin juga untuk melarutkan gas-gas berbahaya tersebut agar tidak beredar bebas. Mengindentifikasi jenis dan jumlah konsentrasi gas yang terlarut pada minyak dapat memberikan informasi akan adanya indikasi kegagalan yang terjadi pada transformator. Metode untuk mengidentifikasi dan menganalisis gas-gas terlarut pada minyak disebut sebagai DGA (Dissolved Gas Analysis).Penelitian ini akan membahas bagaimana uji DGA dapat mengidentifikasi indikasi kegagalan yang terjadi pada transformator. Sejumlah sampel minyak diambil dari minyak isolator pada sebuah transformator daya lalu sampel tersebut dimasukkan ke dalam peralatan uji DGA Transport X Kelman. Hasilnya adalah sejumlah data yang menunjukkan tingkat konsentrasi fault gas. Setelah memperoleh sejumlah data, selanjutnya dilakukan berbagai metode analisis untuk mengetahui indikasi kegagalan yang ada pada transformator daya yang diujikan.Berdasarkan data yang diperoleh pada pengujian dan analisa gas terlarut disimpulkan transformator masih dalam keadaan baik untuk di operasikan karena tidak ada kandungan gas yang terlalu signifikan karna parameter nilai konsentrasi gas masih berada dalam nilai normal.
ANALISIS PENGARUH PERUBAHAN RO DAN Ri PADA TURBIN ULIR ARCHIMEDES SARWAN Saleh, Zulkiffli; Oktaviani, Wiwin A; Pratama, Muhammad Yoga
Jurnal Teknik Elektro Vol 12 No 1 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i1.652

Abstract

Fokus penelitian ini diarahkan pada analisis pengaruh perubahan diameter dalam rotor (Ri) dan diameter luar rotor (Ro) terhadap daya yang dihasilkan sistem PLTMH untuk menentukan kondisi optimal kerja sistem. Salah satu parameter signifikan pada PLTMH berbasis turbin ulir Archimedes adalah besaran Ro dan Ri, perubahan nilai tersebut akan berpengaruh pada daya keluaran sistem. Dari hasil pengukuran dan perhitungan data yang dilakukan pada PLTMH Sarwan didapatkan kecepatan aliran air maksimum sebesar 7,7112 m/dt dan kecepatan aliran air minimum sebesar 2,7463 m/dt, dan Ri optimal sebesar 0,56 m dengan daya terbangkitkan sebesar 4,098 kW
PENERAPAN IEEE 519-2014 TERHADAP IDENTIFIKASI DISTORSI HARMONISA PADA TRANSFORMATOR 3 FASA Wardhany, Arum Kusuma; Monika, Dezetty; Gumilar, Langlang
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.835

Abstract

Transformator merupakan peralatan yang paling merasakan adanya harmonik, karena letaknya yang lebih dekat terhadap beban. Pada transformator, harmonik arus (THD% I) akan menyebabkan peningkatan rugi-rugi tembaga (Cu), sedangkan harmonik tegangan (THD% V) menyebabkan peningkatan rugi-rugi arus Eddy (Eddy Current) sehingga terjadi kerugian daya dan peningkatan temperatur. Pada penelitian ini dilakukan untuk mengetahui gangguan harmonik pada transformator 3 phasa dari pemakaian beban non linier dengan cara mengidentifikasi tingkat dominan harmonik, THD % arus maupun tegangan, peningkatan temperatur dan estimasi kerugian daya yang dimonitoring secara real-time menggunakan software IoT Blink. Hasil pengujian menunjukkan bahwa harmonisa arus pada transformator 3 phasa menimbulkan rugi – rugi tembaga (Cu) sebesar 0,0424 pu (setara 57,98 W) dan rugi arus eddy sebesar 0,0370 p.u (setara 50,60W).
ANALISA MOTOR INDUKSI TIGA PHASA PADA PENGGERAK BELT CONVEYOUR 22 BANKO BARAT PT. BUKIT ASAM, TBK Yansuri, Daeny Septi; Subianto, Subianto; Rizal, Choirul; Suherman, Edy; Ramadhon, Efri
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.845

Abstract

Bukit Asam. Tbk bergerak di bidang eksploirasi batubara, dalam penyaluran batubara tersebut, perusahaan ini menggunakan Belt Conveyour di setiap unit penyaluran nya. Belt Conveyour tersebut digerakkan dengan menggunakan motor-motor induksi tiga phasa. dimana motor yang digunakan memakai penggerak mulanya adalah motor induksi. Adapun motor induksi tiga phasa yang dipakai untuk menggerakkan Belt Conveyour 22 di area Banko Barat PT. Bukit Asam, Tbk adalah motor induksi tiga phasa 110 kW. Pada operasi motor induksi, ada kalanya motor tersebut mengalami gangguan yang disebabkan oleh panas lebih, arus lebih, dan beban lebih. Sehingga jika dibiarkan dapat mengakibat kan kerusakan yang fatal pada motor tersebut. Untuk mempelajari sistem proteksi dan menentukan setelan rele yang baik untuk motor induksi tiga fasa 110 kW di PT. Bukit Asam, Tbk yang digunakan sebagai penggerak Belt Conveyour 22 di area penambangan Banko Barat. Metode penelitian yang dilakukan melalui metode literature,dengan cara mengumpulkan sumber-sumber berupa referensi pada buku-buku yang berkaitan dengan masalah yang diangkat dalam penelitian ini, metode wawancara, mengumpulkan data yang dilakukan dengan tanya jawab langsung, dengan cara mengajukan pertanyaan secara lisan mengenai objek yang akan dibahas, terakhir dengan metode observasi, pengumpulan data yang dilakukan dengan melakukan kunjungan pada perusahaan, yaitu Banko Barat PT. Bukit Asam, Tbk sehingga dapat mengetahui situasi dan kondisi yang sebenarnya. Setelah dilakukan analisa dan perhitungan terhadap hasil penelitian tersebut, maka diperoleh hasil nya, yaitu Besarnya arus gangguan pada motor penggerak Belt Conveyour 22 di Banko Barat PT. Bukit Asam, Tbk adalah sebesar 457,895 Ampere. Setting rele yang dilakukan pada motor penggerak Belt Conveyor 22 di Banko Barat PT. Bukit Asam, Tbk adalah untuk sekring sebesar 413,138 Ampere, Saklar Penghubung sebesar 215,959 Ampere, Kontak Magnet sebesar 244,127 Ampere. Sedangkan Rele Arus Lebih nya adalah sebesar 234,738 Ampere.
PERHITUNGAN JATUH TEGANGAN PADA JARINGAN DISTRIBUSI 20 kV PENYULANG SINGKARAK GI BORANG MENGGUNAKAN SOFTWARE ETAP Indrawasih, Indrawasih; Nurhaida, Nurhaida; Susanti, Indah; Maharani, Dhevia
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.848

Abstract

Besarntya nilai jauh tegangan telah diatur pada SPLNT6.001:2013, tegangan pada terminal pasok perbedaannya tidak boleh lebih besar ± 10% dari tegangan nominal sistem. Penyelidikan nilai jatuh tegangan dilakukan dengan cara mengumpulkan data-data terkait yang dibutuhkan lalu melakukan perhitungan secara manual menggunakan persamaan dan hasilnya dibandingkan dengan hasil simulasi menggunakan software ETAP 19.0.1. Nilai jatuh tegangan pada ujung penyulang singkarak menggunakan perhitungan yaitu 990,07 V atau sebesar 4,87% pada saat beban puncak siang dan 1.210,09 V atau sebesar 6,05% pada saat beban puncak malam, sedangkan hasil simulasi ETAP 19.0.1 nilai jatuh tegangan sebesar 1.030 V atau sebesar 5,07 %. Nilai jatuh tegangan pada penyulang singkarak masih dalam batas SPLN T6.001: 2013.
PERUBAHAN SUDUT PENYALAAN TIRISTOR PADA PENYEARAH JEMBATAN TERSULUT PENUH TERHADAP TEGANGAN DAN PUTARAN MOTOR DC Mutiar, Mutiar; Sunarhati, Marliyus; Dharma, Surya; Marsus, Sutan
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.849

Abstract

Dengan berkembangnya teknologi dewasa ini motor DC banyak digunakan di setiap bidang terutama bidang yang membutuhkan tenaga mekanik seperti menggerakan barang. Pergerakan barang dapat berupa maju dan mundur, keatas dan kebawah dan lain-lain. Untuk melakukan ini motor DC perlu kendalikan oleh peralatan tambahan seperti pengendalian putaran. Pengendalian putaran ini dapat dilakukan dengan menggunakan peralatan penyearah seperti penyearah jembatan terkendali penuh. Penyearah ini dikendalikan oleh rangkaian penyalaan tiristor yang mengatur sudut penyalaan, sehingga tegangan keluaran penyearah akan dapat diatur. Perubahan tegangan dari peyearah jembatan akan mempengaruhi tegangan masukan pada motor DC, jika motor tersebut dihubungkan dengan penyearah. Dari perubahan sudut penyalaan tiristor pada penyearah jembatan tersulut penuh yang dapat merubah tegangan dan putaran Motor DC ini , maka didapatkan dari hasil penelitian ini adalah dengan merubah sudut penyalaan tiristor (α) dari 00 sampai dengan 1800, didapatkan untuk motor tanpa beban didapatkan putaran motor 2132 Rpm dan tegangan jangkar 115 Volt dengan sudut penyalaan 00 , 0 Rpmdan 77 Volt untuk sudut penyalaan 1500.. Begitu juga dengan motor berbeban 0,5 Nm didapatkan putaran Motor 1920 Rpm dan tegangan jangkar 115 Volt dengan sudut penyalaan 00 , serta 0 Rpm dan tegangan jangkar 82 Volt untuk sudut penyalaan 1500.
RANCANG BANGUN ALAT PEMBERI PAKAN IKAN LELE SECARA OTOMATIS BERBASIS MODUL TIMER DH48S-S Mansur, Syaiful; Aryanto, Iqbal May; Tiarto, Eko Hari
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.851

Abstract

Ikan lele merupakan salah satu komoditas perikanan air tawar yang banyak diminati di Indonesia. Faktor yang penting dalam pemelihara ikan lele adalah ketepatan waktu dalam pemberian makan ikan. Kebanyakan dari mereka yang memelihara ikan lele khawatir pemberian makan yang harus dilakukan tiap hari. Maka tujuan penelitian ini adalah penerapan ilmu pengetahuan dan teknologi pada budidaya ikan lele, efisiensi waktu pemberikan pakan ikan, dan membuat alat pakan ikan otomatis berbasis modul timer. Berdasarkan hal tersebut pada penelitian ini dirancang dan dibuat alat pemberian pakan ikan lele otomatis berbasis modul timer dh48s-s. Maka dirancanglah alat yang mempermudah memberi makan ikan yaitu secara otomatis sesuai dengan jadwal yang telah ditentukan. Adapun komponen pendukung penjadwalan pakan ikan diantaranya modul timer dh48s-s sebagai otak dari alat ini yang nantinya akan memerintahkan motor synchronous tyd-49r untuk memutar tempat pakan ikan
PENGARUH HARMONISA TERHADAP RUGI DAYA PADA PENGHANTAR PADA PLTMH SARWAN Saleh, Zulkiffli; Apriani, Yosi; Nazori, Surahman
Jurnal Teknik Elektro Vol 12 No 2 (2022): Jurnal Teknik Elektro
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36546/jte.v12i2.852

Abstract

Tenaga listrik memiliki peranan yang penting dalam upaya untuk meningkatkan kualitas hidup dan pertumbuhan ekonomi di Indonesia. Terbatasnya penyediaan tenaga listrik menjadi salah satu hambatan dalam pembangunan serta pengembangan warga khususnya di wilayah pedesaan. Secara umum, daerah pedesaan terpencil di kawasan perbukitan memiliki kualitas yang baik dalam pembangkit listrik tenaga air. Di daerah yang jauh dari perkotaan, masih banyak daerah yang kekurangan pasokan daya listrik. Salah satu upaya yang dapat dilakukan adalah dengan mengembangkan Pembangkit Listrik Tenaga Mikro Hidro (PLTMH) dengan menggunakan kemampuan energi yang bersumber dari lokal. Tujuan dari penelitian ini adalah untuk mengurangi rugi-rugi daya pada penghantar untuk sistem PLTMH Sarwan. Hasil penelitian ini didapatkan nilai rugi-rugi daya yang terdapat pada beban sebesar 0,0529 Watt sedangkan rugi- rugi yang terdapat pada saluran penghantar adalah 1,8825 Watt, untuk Total Harmonic Distortion (THD) yang terdapat pada harmonisa tegangan sebesar 2.55 % dan THD pada arus sebesar 19.80 %.

Page 7 of 12 | Total Record : 113