Waterbath Temperature Control System with Fuzzy Logic Annastadia Afifah; Levana Forra Wakidi; Her Gumiwang Ariswati; Dyah Titisari; Shubhrojit Misra
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 2 (2023): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.277

Abstract

Unstable temperature or being outside the control temperature of a sample will cause a change in the quality of the sample itself. The purpose of this study was to create a temperature control system on waterbath with fuzzy logic using 7 labels. Used the DS18B20 sensor as a temperature sensor, a processor in the form of an UNO arduino, a thermostat as part of safety control, and displayed on a 16x4 LCD. Temperature selection between 30°C-60C. Design research using pre-experimental methods with one type group of post-testing design research, by comparing modules with comparison tools in the form of digital thermometers. The results of the research in the manufacture of waterbath tools were conducted compared to the results of measurements in the room with a digital thermometer. Obtained the highest Error value of 0.91% at 35 °C and the lowest error of 0.049% at 60 °C. While the error value based on the setting temperature obtained the highest error value at the temperature setting of 30°C of 1.38% and the lowest error at the temperature setting of 60 °C of 0.05%. The average time required to reach the shortest setting temperature in the temperature range is 27°C-30°C for 193 seconds, and the longest time in the temperature range is 27°C-60°C for 2257 seconds. the results showed that the fuzzy method is better compared to conventional methods. The results of this study can be implemented for waterbath temperature control system to get more stable results in maintaining setting temperature.
Design and build analysis of the use of bioradar sensors for portable non-contact respiration monitoring Waode Erimelga Nurfitri; Her Gumiwang Ariswati; Sari Luthfiyah
Jurnal Teknokes Vol 16 No 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v16i2.499

Abstract

Respiratory disorders are a critical health problem. Respiration is a vital activity for the proper functioning of the body. Pandemic SARS-CoV-2 virus is a highly contagious disease and causes rapid spread of droplets. This study aims to determine the effectiveness of the bioradar sensor used in non-contact respiration monitoring by exploring the distance to find out the optimal distance for sensor readings in monitoring respiration rate per minute. The results of this study for the 3 treatments given to respondents did not affect the results of measuring respiration rate. At distances of 10 cm and 25 cm they produce 40-43 times/minute, distances of 50 cm and 75 cm produce 33-36 times/minute, distances of 100 cm produce 20-22 times/minute and distances of 125 cm and 150 cm are not detected. The highest error value is -100.00% at a distance of 125cm and 150cm and the lowest error value is 3.39% at a distance of 100 cm. based on the results of the analysis of the effectiveness of sensor readings on distance, which is quite effective at a distance of ±100 cm. It is hoped that this research can reduce the level of disease transmission during the Covid-19 pandemic. The results of the study showed that the three treatments given to respondents did not affect the results of respiratory rate measurements. At a distance of 10 cm and 25 cm, it produced 40-43 times/minute, at a distance of 50 cm and 75 cm it produced 33-36 times/minute, at a distance of 100 cm it produced 20-22 times/minute, and at a distance of 125 cm and 150 cm it was not detected. The highest error value is -100.00% at a distance of 125 cm and 150 cm, and the lowest error value is 3.39% at a distance of 100 cm. Based on the analysis of the effectiveness of the sensor reading at a distance, it was found to be quite effective at a distance of ±100 cm. The implication of this study is that this bioradar sensor is effective in monitoring breathing rate at a distance of about 100 cm. The results of this study are expected to reduce the level of disease transmission during the Cov-19 pandemic, as non-contact monitoring can help in avoiding droplet spread, which is one of the ways the virus is transmitted. This study provides important information on the use of bioradar sensors in non-contact monitoring of breathing that can be used to improve the safety and quality of healthcare, especially in the context of a pandemic
Guidance And Assistance In Repair Of Centrifuge Laboratory Equipment Based On Standards Of Centrifuge Motor Speed Data In Turi Health Centre, Lamongan Regency, East Java I Dewa Gede Hari Wisana; Her Gumiwang Ariswati; Sumber Sumber; Levana Forra Wakidi
Frontiers in Community Service and Empowerment Vol. 1 No. 1 (2022): March
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v1i1.3

Abstract

One of the equipment in the Turi Health Center laboratory is a Centrifuge. The problem at the Turi Health Center with the centrifuge is that this centrifuge has a large usage load of 8-10 hours per day, without having electromedical personnel. In this Centrifuge, it is often found that the cleanliness of the tools is not good, the placement of the tools is inadequate, the electrical installation network is not standard (Grounding) and the maintenance and maintenance is lacking, there is no regular calibration so there is no certainty of the accuracy of the results obtained. As a result of the impact obtained is a tool that is not suitable for use, the tool is quickly damaged which can harm the diagnosis of patients. Community Service Activities with the implementation team from Poltekkes Kemenkes Surabaya working together as partners in this activity aims to carry out repairs according to Centrifuge standards and provide knowledge and skills about simple maintenance and repairs on Centrifuges Correctly. The first stage in providing solutions to problems faced by the Turi Health Center is to conduct a study through Focus Group Discuss (FGD). The second stage is compiling a user manual. The third stage is the implementation of mentoring and counseling on centrifuge repair using a maintenance and repair manual. And the fourth stage is the implementation of centrifuge repair by providing opportunities for laboratory personnel, Medical and non-medical personnel to be able to independently carry out simple repairs and to know important indicators in the event of damage. The output target of the community service carried out is a simple repair guide book for centrifuge equipment so that later laboratory equipment at the Turi Health Center, especially the Centrifuge, can work according to the Centrifuge Motor Speed Standard.
Internal Calibration For Centifuge Using A Digital Tachometer as a Synergistic Collaboration Between the Health Polytechnic of the Ministry of Health Surabaya and the Turi Lamongan Health Center Her Gumiwang Ariswati; I Dewa Hari Wisana; Sumber Sumber; Levana Fora Wakidi
Frontiers in Community Service and Empowerment Vol. 1 No. 1 (2022): March
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v1i1.4

Abstract

Centrifuge is a laboratory tool used for the process of separating particles of a solution between the filtrate and the substrate through a high-speed centripetal process. The increasing use of Centrifuges at the Turi Lamongan Health Center causes the equipment to be vulnerable to damage. In addition, the lack of handling of these tools is due to limited medical analysts and the absence of electromedical personnel as well as insufficient funds, so that the impact on the health service system at the puskesmas is disrupted. Therefore, it is very important to create a community service program that is carried out in the form of a synergistic collaboration between the Health Polytechnic of the Ministry of Health Surabaya and the Turi Lamongan Health Center which is oriented towards community independence through counseling and assistance, especially in the maintenance of the Centrifuge laboratory. The purpose of this activity is maintenance by testing and calibrating/verifying the motor speed and time on the centrifuge in accordance with the working guidelines. The methodological concept in this activity is to carry out counseling and assistance activities in the maintenance and verification of centrifuge laboratory equipment using a digital tachometer. This activity is an application of previous research on centrifuges and tachometers. The tools used are digital tachometer, savety electrical analyzer, avometer, thermohygrometer, stopwatch and tool set. The materials used are several spare parts, compressors, cleaning tools and cleaning fluids as well as antiseptic fluids. The results obtained from these activities are: 1). The technical specifications of the 4 centrifuge devices are recorded; 2). Identification of damaged centrifuges and those requiring maintenance, namely 2 heavily damaged centrifuges and 2 centrifuges that are still suitable for use; 3). Maintenance of 4 centrifuges; 4). Verification/calibration of 2 centrifuges, namely centrifugal 1 with a relative error of 2.73% in the selection of a motor rotation speed of 2500 rpm is still within the allowable limits (≤10%); for testing the time of 300 seconds, the relative error of 20.57% exceeds the allowable limit, while in centrifuge 2 the results of the relative error in 4 selections of motor rotation speed (rpm) are below 10%, namely 5.92%, respectively 3.82. %, 3.65%, 3.47%. As for the time test, the result of 5.56% is still below the maximum allowable error of 10%. From these results, centrifuge 2 is still in good condition; 5) Implementation of mentoring and counseling for 1 (one) medical laboratory technician (analyst) in performing centrifuge equipment maintenance. The results of this activity can facilitate services at the Turi Public Health Center.
Implementation of Apnea Monitor with Telemedicine Smartphone System (TMSS) for diagnosis and management of sleep-disordered breathing in Cases of Respiratory Disorders in Indonesia I Dewa Gede Hari Wisana; Her Gumiwang Ariswati; Lusiana Lusiana; Farid Amrinsani
Frontiers in Community Service and Empowerment Vol. 1 No. 4 (2022): December
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v1i4.26

Abstract

In connection with the increase in patients with respiratory problems in the Kenjeran Health Centre area of Surabaya City and the cases of respiratory problems in Covid 19 patients which caused a lack of treatment for these patients due to limited health workers and insufficient monitoring equipment, resulting in an impact on the health service system for patients being disrupted. The Community Service Programme with the PKM scheme is carried out in the form of synergistic cooperation between the Poltekkes Kemenkes Surabaya and the Surabaya City Health Office which is oriented towards community independence through counseling and mentoring, especially in the application of the use of Apnea Monitor at the respiration rate using the Telemedicine Smartphone System (TMSS). These problems are obtained from supporting data about the general description, health degree situation, health resource situation, health service efforts and disease cases at the Kenjeran Health Centre obtained from the Surabaya City Community Satisfaction Survey 2016-2021 so that they can be analysed for problem solutions. With the concept of methodology, a design / flow of extension activities and assistance in the application of the use of Apnea Monitor with Telemedicine System carried out by a team consisting of 3 lecturers and 3 students in accordance with their fields of expertise as well as participants from Kenjeran Health Centre and the community in the area, so that the Community Service activities to be carried out are expected to help solve the problems faced by Kenjeran Health Centre. The results of activities that have been achieved are: 1).The results of SPO2 and BPM values on 40 workers are recorded.2). Identification of 40 workers who do not experience respiratory problems; 3). Identification of workers with respiratory problems (none); 4) Implementation of the TMSS apnea monitor system by measuring SPO2 and BPM in smoking workers in the Kenjeran Health Centre area. Future development plans for the Apnea Monitor -TMSS tool can be accessed via the web.
Applications of the Camera Aura Detection Diagnostic Tool for Psychologist in Handling Cases of Mental Health Disorder Due to Domestic Violence in Surabaya City Area Her Gumiwang Ariswati; Hari Wisana, I Gede Dewa; Lusiana; Utomo, Bedjo
Frontiers in Community Service and Empowerment Vol. 3 No. 1 (2024): March
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v3i1.50

Abstract

ABSTRACT The Community Service Program is implemented in the form of synergistic collaboration between the Surabaya Ministry of Health Polytechnic and the Surabaya City Health Service and the Kenjeran Community Health Center as partners that are oriented towards community independence, especially the psychologist community in the implementation of the use of the GDV Camera Aura Detection Tool for Psychologists in Treatment. Cases of Mental/Psychological Health Disorders Due to Domestic Violence in the Surabaya City Area. In connection with the increasing number of cases of mental/psychological disorders due to domestic violence in the Surabaya City area, the limited number of personnel and diagnostic tools has resulted in a lack of treatment for these patients, which has an impact on disrupting the health service system for patients. Mental health, which is a mental or psychological disorder, is still a concern for the Indonesian government at this time. In 2018, as many as 282,654 household members or 0.67 percent of the population in Indonesia experienced mental disorders. Meanwhile, mental disorders due to domestic violence in the city of Surabaya in 2015 amounted to 46.42%, in 2016 the percentage was 46.15%, and in 2017 the percentage was 50%. During the Covid 19 pandemic (2020-2021), 355 women experienced psychological violence. This Community Service activity is an application of several studies in accordance with the road map research that has been carried out by the team leader, including regarding analysis of aura detection with an EEG tool in 2016 which proves that the recorded results of the aura detection tool with EEG results in 2 conditions Psychologically there are differences. On Indonesian Journal of Electrical Engineering and Computer Science Vol. 31, No. 1, July 2023, pp. 553~561 ISSN: 2502-4752 (Scopus Q3) by title ”Aura Detection Using Thermal Camera with Convolutional Neural Network Method for Mental Health Diagnosis” The results obtained from this community service activity were the implementation of socialization and assistance regarding psychological condition examinations using aura detection technology for doctors, psychologists and nurses at partner health centers; Psychological conditions were identified in 6 patients, namely 2 were domestic violence cases and 4 were members of the general public.
Improving Asthma Management through Iot-Based Telemedicine Spirometry in The Post-COVID-19 Era in Sidoarjo Tofu Making Community, Indonesia Luthfiyah, Sari; Gumiwang Ariswati, Her; Lusiana; Gede Hari Wisana, I Dewa; Indriatie
Frontiers in Community Service and Empowerment Vol. 3 No. 3 (2024): September
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v3i3.72

Abstract

Asthma is a chronic inflammatory disease of the airways that causes recurrent episodes of wheezing, shortness of breath, chest tightness and coughing. The partners in this study face the problem that tofu factories in their area use plastic waste as fuel, which can aggravate respiratory conditions. In addition, the partners need more knowledge about the clear signs of asthma attacks, asthma symptom control and risk factors for asthma patients. The solution provided through the Community Service Programme with the PKM (Student Creativity Programme) scheme is to measure lung volumes using an IoT-based telemedicine device, specifically a spirometry tool that can be used with an Android mobile phone. In addition, partners will receive support to improve their knowledge, skills and attitudes in the management of asthma exacerbations. The implementation method includes providing health education on asthma, clear signs of asthma attacks, asthma symptom control and risk factors for asthma patients, as well as self-management skills for asthma patients and efforts to monitor asthma signs and symptoms. Lung capacity is measured using a spirometry device connected to an Android mobile phone for direct measurement by health workers. The results of the community service show an increase in respondents' knowledge about asthma after a lecture intervention. This was tested using the Wilcoxon signed rank test, which showed a statistically significant increase in scores from pre-test to post-test. All changes were positive, indicating the effectiveness of the learning methods used. Spirometry measurements showed that the respondents' lungs were functioning well without significant airway obstruction, indicating that the intervention was successful in increasing knowledge about asthma and asthma control
Application of the Spirometer and Oximeter Telemedicine Smartphone System in Lung Health Examination of Fish Smoking Workers in the Kenjeran Community Health Center working area Ariswati, Her Gumiwang; Hari Wisana, I Dewa Gede; Luthfiyah, Sari; utomo, bedjo
Frontiers in Community Service and Empowerment Vol. 4 No. 2 (2025): June
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v4i2.80

Abstract

The Community Service Program, in conjunction with the PKM scheme, is implemented through synergistic collaboration between the Surabaya Ministry of Health Polytechnic and the Surabaya City Health Service, focusing on community independence through counseling and assistance, particularly in the use of tools. Implementation of the Use of Spirometers and Oximeters Telemedicine Smart Phone System in Lung Health Examinations -Lungs of fish smoking workers in the Kenjeran Community Health Center work area. In connection with the increase in patients with cases of respiratory problems in the Kenjeran Community Health Center area, Surabaya City, as well as cases of respiratory problems in post-COVID-19 patients, which has resulted in a lack of treatment for these patients due to limited health personnel and no monitoring equipment. insufficient, so that the health service system for patients is disrupted. The use of a spirometer with a telemedicine smartphone system is expected to help people in Indonesia, especially in the Surabaya city area, to conduct early examinations independently and provide this information to medical personnel if any readings fall outside the specified parameters. This activity is an application of research following the road map (Road map Research), which has been carried out starting in 2019 to design an Apnea monitor to detect respiration rate in babies and adults using Piezoelectric sensors. Until 2024, it has been developed with a spirometer and oximeter with a telemedicine smart phone system and has been published in the journal IJEEMI, 2024, with the title Design and Development of an IoT-based Pulmonary Function and Oxygen Saturation Measurement Device (Pulmonary Function Analysis). In this activity, 21 fish smoking workers in the Kenjeran Community Health Center work area were examined using a spirometer and an oximeter smartphone telemedicine system carried out by the Team. Resulted in lung function measurements with FEV1/FVC ratio values, 86% normal and 14% restrictive
System Motor Gearbox Control For Increase Accuracy Angle On CPM Elbow Tool PID Method Kurniawan, Desi Dwi; Ariswati, Her Gumiwang; Lamidi; Sumber
Jurnal Teknokes Vol. 18 No. 1 (2025): March
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Continuous Passive Motion (CPM) is a rehabilitation tool designed to help joint recovery after surgery by passively moving the joint within a certain range of motion. Previous studies have used the ATmega8535 microcontroller with a PWM system. In this study, a control system was developed using Proportional-Integral-Derivative (PID) to improve the angular accuracy of the CPM tool specifically for the elbow joint. The implementation of PID aims to control the gearbox motor to achieve angles of 45°, 90° and 130° which drive the CPM tool so that it can operate with high accuracy and adjust the angle according to the desired therapy settings. This tool using Encoder sensor to detect corner movement joints in real-time. The Arduino Uno microcontroller controls the motors based on feedback from the sensors and optimizes movement through PID control . Research results show that PID system can increase accuracy corner with a low average error . In addition , the system is also equipped with with measurement current using the ACS712 sensor for ensure stability Power during operation . Result of study This can read 45°, 90° and 130° angles with a good level of accuracy , besides it is also capable operated with speed of 40°/ min , 90°/ min , 150°/ min , 210°/ min and 270°/ min . In the measurement readings on the compared devices with Goniometer there is difference error at 45° angle is 5°, 90° angle is 1° and 130° angle is 5°. for measurement current on the device the obtained stable value​ 2.5mA.Research This succeed reach optimization control angle on the CPM tool with level good accuracy , so that can support the rehabilitation process patient with more effective and efficient .
Analysis Infinite Impulse Response Filter for Reducing Motion Artifacts in Heart Rate Signals Based on Photoplethysmography Fadillah, Wa Ode Nurul; Ariswati, Her Gumiwang; Caesarendra, Wahyu
Jurnal Teknokes Vol. 17 No. 3 (2024): September
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The increasing prevalence of motion artifacts (MA) in photoplethysmography (PPG) signals poses significantchallenges for accurate heart rate monitoring, particularly in dynamic environments. This study addresses the problem of MAinterference in PPG signals, which can lead to erroneous heart rate readings and compromised patient monitoring. To mitigatethis issue, we employed an Infinite Impulse Response (IIR) filter to enhance the quality of PPG signals by effectively reducingthe impact of motion artifacts. The methodology involved collecting PPG signals from a sample of participants during variousphysical activities. The raw signals were subjected to both filtering and non-filtering processes using MATLAB, allowing fora comparative analysis of the signal quality. The filtering process was designed to suppress unwanted frequencies associatedwith motion while preserving the physiological signals of interest. The performance of the IIR filter was evaluated based onthe Signal-to-Noise Ratio (SNR) and the accuracy of heart rate extraction. Results indicated a significant improvement insignal quality post-filtering, with the SNR increasing from an average of 5.2 dB to 15.8 dB, demonstrating a substantialenhancement in the clarity of the PPG signals. Furthermore, the heart rate extraction accuracy improved from 78% to 95%after applying the IIR filter, showcasing the effectiveness of the proposed method in real-time applications. In conclusion, theapplication of the IIR filter in processing PPG signals effectively reduces motion artifacts, leading to more accurate heart ratemonitoring. This research highlights the potential for improved patient outcomes in clinical settings and suggests furtherexploration of advanced filtering techniques to enhance the reliability of wearable health monitoring devices. The findingsunderscore the importance of addressing motion artifacts in the development of robust biomedical sensing technologies.