Analysis of the Increase of Transformer Power Losses due to the Operation of Unbalanced Nonlinier Loads I Wayan Rinas; I Made Suartika; Anak Agung Maharta Pemayun
Journal of Electrical, Electronics and Informatics Vol 2 No 2 (2018): JEEI (August 2018)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2018.v02.i02.p04

Abstract

Non-linear loads are the source of harmonic current for electric utilities. The high level of harmonics greatly affects the increase of losses of electrical power (losses). The quality of electric power is determined by the parameters of power losses that occur in the transformer due to harmonic distortion. In this research will be analyzed THD from result of measurement and simulation in accordance with IEEE 519-2014 standard, power loss analysis on transformer before and after. Harmonics, the impact is increased due to unbalanced linear currents.
Operation of LED Light as Emergency Lighting Resource DC with Charger Control Based Arduino Uno ATmega I Wayan Rinas; I Made Suartika; Anak Agung Maharta Pemayun; I G. A. P. Raka Agung
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p04

Abstract

Lighting is very important to support the activities of human life. To maintain the continuity of lighting can use power source from genset or battery. Now many manufactured LED (light emitting diode) bulb type which is energy saving with life time up to 50.000 hours. LEDs of this type can be operated with AC and DC current. The design control charger based Arduino Uno ATmega micro controller is used as a control system for charging and turning on LED lights. In this research the measurement of light intensity is done at 220 volt AC as reference, then measured the intensity of light for operation on some variation of DC voltage. The measurement results at DC voltage, LED Osram can be operated at 115 volt DC has reached the same light intensity with 220 volt AC. This selection aims to reduce the amount of battery usage as a DC power source.
Damping Harmonic Distortion Using Active Filter with PID Control at Udayana University Faculty of Engineering Bukit Jimbaran I Made Suartika; Rukmi Sari Hartati; I.B.G. Manuaba
Journal of Electrical, Electronics and Informatics Vol 2 No 2 (2018): JEEI (August 2018)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2018.v02.i02.p02

Abstract

Increased THD (Total Harmonics Distortion) in the utility, caused by the increasing operation of non-linear loads. High THD current (THDi) will affect the increase of power losses in the power system. In this study, THD analysis of the simulation results was performed according to IEEE 519-2014 standard on existing condition, shunt active filter operating condition and shunt active filter operating conditions with PID (proportional integral derivative) control, also analyzed losses before and after harmonic impact. The result of losses analysis on existing condition: losses phases R 3.38%, phase S 2.29%, phase T 3.33%. Total losses on existing condition 9.01%. Operation with active shunt filter is obtained losses for phase R 1.60%, phase S 2.46%, phase T 1.67%, so the total losses become 5.73%. While using the active filter with PID control for losses phase R 1.02%, phases S 0.89%, phases T 0.99%, so the total losses fell to 2.18%