Simulation-Based Design of LTE Indoor Networks in High-Density Building Scenarios Ryan Prasetya Utama; Regina Leonnie; Faiz Husnayain
Jurnal Elektronika dan Telekomunikasi Vol. 26 No. 1 (2026)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.816

Abstract

The implementation of 5G mobile communication technology in Indonesia faces significant challenges due to limited infrastructure and coverage in some areas, that’s why 4G technology is still the favorite among the public. However, not all areas are covered by a good quality 4G LTE (Long Term Evolution) network, especially inside buildings, because the signal from the eNodeB weakens due to the building construction. This study aims to determine the optimal antenna configuration to improve network quality inside the building, in this case in the XYZ building by implementing an IBS (Indoor Building Solution) on the 4G LTE network using Radiowave Propagation Simulator software. The IBS design uses two approaches, namely coverage dimensioning and capacity dimensioning. The simulation comparing the location of antenna placement in the center or edge building and the results show that placing the antenna in the center of the building is more optimal than placing it at the edge of the building. The average of RSSI (Received Signal Strength Indicator) values obtained from the ground floor to the 2nd floor are -46.67 dBm, -50.09 dBm, and -49.41 dBm, respectively. Meanwhile, the average of SINR (Signal to Interference plus Noise Ratio) values obtained from each ground floor to the 2nd floor are 18.77 dB, 23.20 dB, and 27.77 dB, respectively. Both parameter values are included with an Excellent rating based on the RKX operator's KPI (Key Performance Indicator) standards. It is hoped that the results of this research can be used as a reference, model, and implemented in other indoor locations so that 4G network coverage in Indonesia can be further expanded, especially indoors.
Integrated SCADA Framework for Acid Deposition Monitoring with Occupational Safety Management Tsaqif Muhammad; Faiz Husnayain
Journal of Business, Social and Technology Vol. 7 No. 4 (2026): Journal of Business, Social and Technology
Publisher : Politeknik Siber Cerdika Internasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59261/bustechno.v7i4.758

Abstract

Background: Acid deposition is a transboundary environmental problem that demands a reliable and safe measurement system. Previous studies on the same chamber progressed from manual measurement to real-time IoT monitoring; however, they still lacked centralized supervision, automated safety mechanisms, and early detection of sensor faults. Objective: This study aimed to develop and evaluate an integrated supervisory system that combines Occupational Health and Safety (OHS) management with condition-based maintenance for acid deposition monitoring. Methods: The system was designed using a Software-in-the-Loop (SiL) architecture within the Siemens ecosystem, following the ISA-95 framework, and was subsequently evaluated through fault-injection scenarios. Results: The system monitored pH, temperature, water level, and actuator status at 1-second intervals without communication failures or data loss. The safety module detected all three tested hazardous pH conditions below 5.6, resulting in a Probability of Detection (POD) of 100%. The maintenance module detected out-of-range values and triggered an emergency shutdown after three faults occurred within 60 seconds. Availability varied from 66% to 93%, depending on failure frequency and repair time, indicating that faster recovery and fewer repeated failures improved system reliability. Conclusion: The findings indicate that integrating supervision, OHS management, and condition-based maintenance can strengthen the safety, traceability, and reliability of acid deposition monitoring. The main novelty lies in integrating these functions within a single SCADA architecture validated through Software-in-the-Loop simulation, providing a practical basis for safer environmental monitoring stations and subsequent field implementation.
Comparison of Volt–VAR Control and Power Factor Control of PV Inverters on the Voltage Profile of Low Voltage Distribution Networks Husnayain, Faiz; Azkiya, Laaliya
ELKHA Vol. 18 No.2 October 2026
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v18i2.105464

Abstract

The rapid increase of photovoltaic generation in low-voltage distribution networks can trigger voltage rise and overvoltage, particularly on feeders with a high resistance-to-reactance ratio. This study compares two smart-inverter voltage regulation strategies—volt–var control and power-factor control—to mitigate overvoltage and to increase the voltage-constrained photovoltaic penetration limit. A detailed low-voltage feeder model was developed, and steady-state power-flow simulations were performed in PowerFactory under two operating scenarios representing overvoltage and undervoltage conditions. Performance was evaluated using maximum bus voltage and network power losses while the photovoltaic penetration level was increased gradually. Without inverter control, the voltage limit was exceeded at a higher penetration level, limiting acceptable penetration to 125%. With volt–var control, reactive power is exchanged only when the local voltage deviates from a normal-voltage band, so overvoltage is mitigated effectively with a smaller increase in losses, extending the acceptable penetration to 140%. Power-factor control provides stronger voltage reduction because many inverters respond simultaneously following active power output, enabling the highest acceptable penetration of 150%, but it tends to drive larger reactive power flow and higher losses. Overall, both strategies improve voltage compliance and hosting capacity, but the trade-off between voltage reduction and increased losses indicates that the preferred method should be selected based on feeder operating conditions and the utility objective.