PERBANDINGAN PERFORMANSI AIR CONDITIONING HIBRIDA PADA STANDBY MODE (TRADITIONAL AC) DENGAN BEBAN PENDINGINAN 1000 WATT DAN TANPA BEBAN PENDINGINAN Azridjal Aziz; Eko Prasetyo; Rahmat Iman Mainil
Jurnal Sains dan Teknologi Vol 19, No 1 (2020): Jurnal Sains dan Teknologi
Publisher : Fakultas Teknik Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (747.392 KB) | DOI: 10.31258/jst.v19.n1.p19-27

Abstract

AbstractThe experimental study of a hybrid AC (Air Conditioning) system (utilizing both cooling and heating sides) in standby mode (traditional AC) operated without cooling load and with 1000 Watt cooling load has been carried out in this study. Hybrid AC performance without load compared to condition with a load of 1000W had the average COP (Coefficient of Performance) of around 2.460 versus 2.452, PF (Performance Factor) of around 3.42 versus 3.41 and TP (Total Performance) of around 5.88 versus 5 .86, respectively. The test results showed that by using cooling load of 1000 Watt, could provide an average cooling room temperature of 28.3 °C, a heating room temperature of 44.9 °C, a compressor power of 0.5825 kW while the result of without cooling load condition, the temperature of the cool room was average 22.5 °C, heating room temperature of 38.8 °C, compressor work of 0.5449 kW. The test results of the AC hybrid machine with HCR-22 refrigerant showed that the condition of without cooling load had a performance that was little bit different compared to the cooling load of 1000W. This results showed that the temperature of the cold room with a cooling load of 1000 Watt made the temperature of the cold room was uncomfortable for human, so that the cooling load must be reduced or the cooling capacity must be increased.
KARAKTERISTIK KINERJA PIPA KALOR MENGGUNAKAN STRUKTUR WICK SCREEN 100 MESH DENGAN FLUIDA KERJA AIR Wandi Wahyudi; Rahmat Iman Mainil; Azridjal Aziz; Afdhal Kurniawan Mainil
Jurnal Sains dan Teknologi Vol 15, No 1 (2016): Jurnal Sains dan Teknologi
Publisher : Fakultas Teknik Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (529.661 KB) | DOI: 10.31258/jst.v15.n1.p12-17

Abstract

 Pipa kalor merupakan alat penukar kalor dengan dimensi yang kecil tetapi dapat memindahkan kalor yang besar. Banyak penelitian mengenai pipa kalor, guna memperoleh peningkatan kinerja termalnya dengan memodifikasi fluida, orientasi, kecepatan putar dan struktur wick. Dalam penelitian ini pipa kalor dibuat dari pipa tembaga berdiameter 9,525 mm, tebal 1 mm dan panjang 400 mm menggunakan screen 100 mesh sebagai struktur wick dengan air sebagai fluida kerja. Variasi pengujian menggunakan 3 variasi sudut kemiringan 0o, 45o, 90o dan 4 variasi heat input 3 watt, 4 watt, 5 watt dan 6 watt untuk melihat pengaruhnya pada kinerja pipa kalor. Hasil penelitian menunjukkan bahwa semakin besar sudut kemiringan terhadap heat input, maka semakin kecil nilai hambatan termalnya. Hambatan termal terendah terjadi pada sudut 90o dengan heat input 6 Watt sebesar 8,60˚C/Watt. Koefisien perpindahan panas terbesar dan temperature difference terkecil terjadi pada sudut kemiringan 90o dengan nilai 97,70W/˚C m² dan 31,8°C.
LAJU PENDINGINAN AIR DENGAN ICE ON COIL PADA MESIN PENDINGIN TYPE CHILLER UNTUK COLD STORAGE Irwandi Hidayat; Azridjal Aziz; Herisiswanto '; Rahmat Iman Mainil
Jurnal Sains dan Teknologi Vol 14, No 1 (2015): Jurnal Sains dan Teknologi
Publisher : Fakultas Teknik Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (402.672 KB) | DOI: 10.31258/jst.v14.n1.p%p

Abstract

Es pada coil adalah teknologi penyimpanan es dimana pipa atau coil yang direndam didalam air. Es terbentuk diluartabung dengan sirkulasi pendingin sekunder atau pendingin didalam tabung terjadinya es. Mesin-mesin pendingin padasaat ini telah banyak berkembang seiring dengan kemajuan teknologi. Umumnya mesin ini digunakan untukpengawetan makanan, sayuran dan buah. Mesin pendingin ini bertujuan mendinginkan air sebagai refrigeran sekunderhingga bertemperatur 0oC untuk mengukur kemampuan mesin pendingin dalam mendinginkan ruangan dan kotakpenyimpanan dingin. Performansi mesin pendingin untuk kotak penyimpanan dingin dan ruangan mempunyaiperbedaan nilai. Nilai COP yang ke ruangan lebih besar dibanding dengan yang ke kotak penyimpanan dingindisebabkan kerja yang diberikan ke ruangan lebih besar dari pada ke kotak penyimpanan dingin, perubahan entalpievaporator juga sangat mempengaruhi nilai COP, semakin besar perubahan entalpi evaporator maka akan semakin besarpula nilai COP yang diberikan mesin tersebut.
KOMPARASI KINERJA REFRIGERATOR DENGAN REFRIGERAN HIDROKARBON HCR134a ALTENATIF PENGGANTI R134a PADA PANJANG PIPA KAPILER 1,25 m Azridjal Aziz; Izzudin Ali Raja Siregar; Rahmat Iman Mainil; Afdhal Kurniawan Mainil
Jurnal Sains dan Teknologi Vol 19, No 2 (2020): Jurnal Sains dan Teknologi
Publisher : Fakultas Teknik Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (802.257 KB) | DOI: 10.31258/jst.v19.n2.p76-81

Abstract

Pada penelitian ini telah dilakukan uji komparasi mesin pendingin siklus kompresi uap dengan fluida kerja HCR134a (refrigeran hidrokarbon pengganti R134a) dan fluida kerja R134a yang beroperasi pada  panjang pipa kapiler 1,25m dengan pendinginan udara. Analisisis  dilakukan terhadap pengaruh tekanan dan temperatur, arus listrik,  kerja kompresi, dan koefisien perfomansi (COP) alat uji. Hasil penelitian menunjukkan,  penggunaan HCR134a meningkatkan COP sebesar 29.92% dengan  penggunaan arus listrik lebih rendah 10.8% dibandingkan dengan R134a. Dari uji komparasi dapat disimpulkan bahwa penggunaan refrigeran hidrokrabon (HCR134a) memberikan kinerja yang lebih baik dan lebih hemat energi dibanding refrigeran halokarbon  (R134a).
EFEK BEBAN PENDINGIN TERHADAP TEMPERATUR MESIN REFRIGERASI SIKLUS KOMPRESI UAP HIBRIDA DENGAN KONDENSOR DUMMY TIPE TROMBONE COIL ( 1/4″, 7,9 m) SEBAGAI WATER HEATER Aulian Samri; Azridjal Aziz; Rahmat Iman Mainil; Afdhal Kurniawan Mainil
Jurnal Sains dan Teknologi Vol 15, No 2 (2016): Jurnal Sains dan Teknologi
Publisher : Fakultas Teknik Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (509.707 KB) | DOI: 10.31258/jst.v15.n2.p51-56

Abstract

Mesin pengkondisian udara hibrida dapat memberikan solusi untuk mengatasi masalah penggunaan energi listrik yang berlebihan, dengan cara memanfaatkan panas buang kondensor yang digunakan untuk pemanas air. Penelitian ini dilakukan untuk mengetahui pengaruh penambahan beban pendinginan terhadap temperatur pada sistem pengkondisian udara hibrida dengan kondensor dummy tipe trombone coil diameter 1/4″ panjang 7,9 meter sebagai water heater. Penelitian ini menggunakan metode eksperimental. Penelitian ini menggunakan beban pendinginan pada ruang simulasi dengan variasi pembebanan 0 Watt, 1000 Watt, 2000 Watt, dan 3000 Watt. Berdasarkan hasil pengujian, nilai tertinggi terjadi pada pembebanan 3000 Watt. Dimana temperatur air yang dihasilkan sebesar 48,34 ˚C, temperatur rata-rata refrigeran hasil kompresi sebesar 62,68 ˚C dan temperatur ruangan rata-rata mencapai 25,94 ˚C saat pengoperasian selama 120 menit.
PENGARUH FLUIDA KERJA CAMPURAN AIR – ASETON TERHADAP KINERJA PERPINDAHAN PANAS PADA PIPA KALOR Utari Prayetno; Rahmat Iman Mainil; Azridjal Aziz
Jurnal Sains dan Teknologi Vol 14, No 2 (2015): Jurnal Sains dan Teknologi
Publisher : Fakultas Teknik Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (587.035 KB) | DOI: 10.31258/jst.v14.n2.p%p

Abstract

Pipa kalor adalah sebuah teknologi penghantaran panas dengan menggunakan pipa berukuran tertentu yang berisi cairan khusus sebagai penghantar panas dari ujung yang panas ke ujung lain sebagai fluida kerja. kinerja perpindahan panas pipa kalor dengan panjang 400 mm dan diameter 9,5 mm menggunakan fluida kerja campuran air – aseton telah selesai di teliti. Fluida kerja yang digunakan adalah fluida campuran air – aseton dengan rasio koensentrasi 50% : 50% dan filling ratio sebanyak 10% dari total volume pipa kalor. Penelitian mengenai pipa kalor telah dilakukan dengan variasi sudut kemiringan 0o, 45o, dan 90o. Pemberian beban panas juga divariasikan dari 3 W, 4 W, 5 W dan 6 W untuk mempelajari pengaruhnya terhadap kinerja perpindahan panas pipa kalor. Hasil penelitian menunjukkan semakin tinggi heat input dan sudut kemiringan, akan memberikan pengaruh semakin rendah hambatan termal dan semakin tinggi koefisien perpindahan panas pada pipa kalor. Pipa kalor dengan menggunakan fluida kerja campuran air – aseton dapat mereduksi temperatur evaporator rata – rata 63,68 oC, dengan hambatan termal rata - rata 6,71 oC/W, dan koefisien perpindahan panas tertinggi rata – rata 126,01 W/m2 oC.
Pengaruh Penggunaan Katup Ekspansi Jenis Kapiler Dan Termostatik Terhadap Tekanan Dan Temperatur Pada Mesin Pendingin Siklus Kompresi Uap Hibrida Eko Saputra; Azridjal Aziz; Rahmat Iman Mainil
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 2, No 2 (2015): Wisuda Oktober Tahun 2015
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Research conducted into 4 variation is varied using capillary expansion valve standard conditions, thermostatic expansion valves standard conditions, capillary expansion valve with additional hotspot water heater, and thermostatic expansion valve with additional hotspot water heater. Data is collected every five minutes during the 120 minutes of testing. The research aimed to find out the performance of the engine coolant when the use of capillary expansion valve, thermostatic water heater and additional Hotspot Water Heater (HWH). Performance cooling machine includes pressure and temperature. The test results demonstrate the use of standard conditions thermostatic expansion valve compressor working pressure lower at 322.37 Psia thermostatic and 323.2 Psia capillary compared to 0.26% while the condition with the use of thermostatic valves HWH lower at 274.03 psia thermostatic compared to the capillary 287.37 psia amounted to 4.64%. To pressure thermostatic expansion valve using standard conditions and with the use of HWH lower than that of thermostatic capillary than the capillary are 92.12 Psia and 105.95 Psia at 13.05% and thermostatic 67.28 Psia and 94.45 Psia compared capillary amounted 28.77%, Compressors temperature for use thermostatic standard conditions and with the use of HWH higher than the capillaries are 90.85oC thermostatic compared capillary 83.74 oC at 7.83% and 91.31 °C thermostatic compared to the capillary 79.77 °C at 12.64%. For the hotspot temperature in the water heater using thermostatic higher than the capillaries are 87.26 oC thermostatic compared capillary 77.34 oC at 11.37% while the hotspot temperature of the water heater out thermostatic more likely the same that thermostatic capillary 46.95oC than 48.44 °C of 3.07%.Keywords : Thermostatic Expansion Valve, Pressure, Temperature, dan HWH
Aplikasi Modul Evaporative Cooling Aktif Pada AC Split 1 PK Ahmad Wisnu Sulaiman; Azridjal Aziz; Rahmat Iman Mainil
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 3, No 2 (2016): Wisuda Oktober Tahun 2016
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The commonly used air conditioning system is the air conditioning system with vapor compression cycle. However, vapour compression cycle has an operation problem, which is the high energy consumption caused by air cooled condenser type. The condensors disadventages is temperature will increase when ambient temperature increases, it reduced the heat rejected by condenser. This studies used evaporative cooler moduleon condenser inlet to reduce the entering air temperature. The module efect on standard vapour compression cycle performance was tested using experimental methods by testing the effect of water discharged (0.88, 1.04, 1.2 L/min) with the power input. The result showed standard cycle power input with 2000 W cooling load is 0.586186 kW, and the lowest power input of a modification cycle is 0.547665 kW with water discharged 1.2 L/min.Keywords : Evaporative Cooler, Power input, Heat rejection, Condenser
Pengaruh Perpindahan Panas Pipa Kalor Pada Posisi Horizontal Ruben Siregar; Rahmat Iman Mainil; Azridjal Aziz
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 3, No 2 (2016): Wisuda Oktober Tahun 2016
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Heat pipes are devices that can transfer heat from one point to another point very quickly at a constant temperature difference, with large heat transfer capacity. Heat pipe used in a wide variety of manufactured products, such as laptops, mobile phones, and others. Solid copper and heat pipes are make to have a diameter of 3/8 "and with a length of 40 cm with a filling ratio of 10%. Solid copper and heat pipe was tested in the horizontal position and temperature data obtained in the evaporator section, adiabatic and condenser. Heat transfer rate of heat pipe using wick is 8.82 W, without using wick is 8.36 W and with solid copper is 1.22 W. The thermal conductivity of the heat pipe without wick 5291.18 W / mK and then use wick 6294.69 W / mK, solid copper 75.42 W / mK. Comparison of thermal conductivity between a heat pipe using wick with a copper solid is 83.46 times higher.Keywords : heat pipe, filling ratio, wick
Kaji Eksperimental Turbin Angin Darrieus-H Dengan Bilah Tipe Naca 2415 Giri Saputra; Azridjal Aziz; Rahmat Iman Mainil
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 3, No 1 (2016): Wisuda Februari Tahun 2016
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The wind turbine is divided into two types: vertical axis wind turbine and horizontal axis wind turbine. A vertical axis wind turbine is likely better than horizontal axis due to unaffected by the direction of the wind and capable for rotating at low wind speeds. The Darrieus-type H is one of vertical wind turbines type, with rotor structure of H-shaped, which capable for a low speed of wind flow areas. Sequence, it meets the Riau Province areas to apply one. This research aim is to test the performance of implementation of a vertical axis wind turbine model, Darrieus type-H blades with naca 2415 in Riau Province area. This research used an experimental method to investigate the vertical axis wind turbine models, Darrieus type-H blades with naca 2415. The wind speeds were chosen on 3.87 m/s, 4.53 m/s, 5.06 m/s, which used a fan as the wind source. Then, the wind of fan was flowed through a simple wind tunnel. The pitch angel was set on 10°, 15°, 20°, 25°, 30°, 80° and 90°, with a load of 250 grams. The results were obtained the optimum performance on a pitch angel of 90°, at wind speed of 3.87 m/s for power generated 0.27 Watts, and the efficiency of 3.81%.Keyword: Pitch angel, Darrieus-H, coefficient of performance
Co-Authors Abd. Rasyid Syamsuri Adha, Aidil Adi Hans Purba Adriyandy, Warits Adriyus putra Afdhal Kurniawan Mainil Ahmad Surya Ahmad Wisnu Sulaiman Anggriawan, Akbar Anita Susilawati Atria Martina Aulian Samri Auliaswan, Fayzil Awaludin Martin Aziz, Azdrizal Azridjal Aziz Banjarnahor, Syahdi Fahala Bungsu Herwanto Cahyati, Wulan Dani Ikhsan Putra Darfia, Novreta Deni Kurniawan Dicky Ikhwandi Eigko Malau Eko Saputra Faisal Afif Faisal Tanjung Farida Isroani Ferly Septian Iskandar Fuad, N Gihon Matondang Giri Saputra Gontor Andrapica Gordon HTTM Hasra Rafika Helmizar - Hendra Abdul Aziz Hendrik Syahputra Henni Syawal Herisiswanto ' Herisiswanto, Herisiswanto Irwandi Hidayat Izzuddin Ali Raja Siregar, Izzuddin Ali Raja Izzudin Ali Raja Siregar Jenvrizen, David KHOIRUL ANAM Khotso Sai Listiono, Hendra luthfi afiif yazu Muh Wira Tri Kusuma, Muh Wira Tri Muhammad Faizal Syukrillah Muhammad Faizal Syukrillah, Muhammad Faizal Muhammad Ilham Muhammad Rif’at Syahnan N. Nazaruddin Nasution, Fikri Fahlevi Nofriadi Nofriadi Novreta Ersyi Darfia NST, Berriansyah Cipta Nugrah Suryanto Nurcholish Windiharto Nurman Saputra Nurul Deswita P. Eko Prasetyo Parija, Iqbal Perima, Yoan Purba, Adi Hans Putra, Rio Ahmad Juliansyah Rahman Asfaranda Renaldi Khaesar Kumara Renhard Niptro G, Renhard Niptro Renhard Niptro Gultom Ridwan Abdurrahman Rizqullah, Ibnu Ruben Siregar Saberina Hasibuan Sarwo Fikri Sayfri Syafri Sihombing, Tikkos Solly Aryza Suprayitno Suprayitno Surya, Ahmad Syafri ' Teguh Irawan Thalal, Thalal Tio Vani Nesri Utari Prayetno Wandi Wahyudi Yandra, Vicky Yoan Perima Yovan Witanto