cover
Contact Name
Astri Rinanti
Contact Email
astririnanti@trisakti.ac.id
Phone
+6221-5663232
Journal Mail Official
urbanenvirotech@trisakti.ac.id
Editorial Address
Department of Environmental Engineering Faculty of Landscape Architecture and Environmental Technology Universitas Trisakti, Jakarta Gedung K, Kampus A Jl. Kyai Tapa Grogol Jakarta 11440, Indonesia
Location
Kota adm. jakarta barat,
Dki jakarta
INDONESIA
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY
Published by Universitas Trisakti
ISSN : 25799150     EISSN : 25799207     DOI : https://dx.doi.org/10.25105
The scope of the journal emphasis not limited to urban environmental management and environmental technology for case study in Indonesia and for other region in the world as well. Urban Environmental Management: environmental modeling, cleaner production, waste minimization and management, energy management and policies, water resources management, water supply and sanitation, industrial safety and health, water recovery and management, urban environmental pollution-diseases and health status, eco-drainage, flood risk management, risk mitigation, climate change and water resource adaptation. Environmental Technology: energy efficiency, renewable energy technologies (bio-energy), environmental biotechnology, pollution control technologies (wastewater treatment and technology), water treatment and technology, indigenous technology for climate change mitigation and adaptation, solid waste treatment and technology
Articles 313 Documents
THE EFFECT OF ROTOR ROTATION SPEED ON DECREASED LABORATORY LIQUID WASTE POLLUTING PARAMETERS Kholif, Muhammad Al; Sutrisno, Joko; Nurhayati, Indah; Setianingrum, Retno
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10572

Abstract

aboratory wastewater is produced through laboratory activities. Laboratory wastewater can have a large impact on the environment if it is not processed before being discharged into the water body. Laboratory waste treatment can be carried out using suspended growth technology to reduce pollutant loads, especially Biological Oxygen Demand (BOD5) and Chemical Oxygen Demand (COD). Aims: This study aims to treat wastewater produced by the activity of laboratory using suspended growth technology. Methodology and Results: This research was conducted by finding the most efficient rotor rotation in degrading the load of BOD5 and COD pollutants. The reactor used is a Mixed Flow Reactor type reactor made of acrylic material with a thickness of 5.5 mm. The reactor is arranged into three series with the same sampling time and different rotor turns that expressed in rotors per minute (rpm). The reactor series consists of Reactor I with 50 rpm rotor rotation speed, 100 rpm Reactor II and 150 rpm Reactor III. Processing is carried out using 8 hours of detention time and variation of sampling time every 8 hours. Conclusion, significant and impact study: From the results of the study obtained the highest level of effectiveness of reducing pollutant load on processing using 150 rpm rotor rotation and 40 hours sampling time which is 94.6% for BOD5 parameters and 94.4% for COD parameters.
DETERMINATION OF DEOXYGENATION RATE OF URBAN RIVER USING MODIFICATION METHODS FOR CITEPUS RIVER WATER, BANDUNG, INDONESIA Yustiani, Yonik Meilawati; Nurkanti, Mia; Tarigan, Fadhlan Khusyairi; Sudarjanto, Gatut
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10740

Abstract

River water quality modeling needs appropriate and suitable coefficients especially in application for specific river like urban river. Aim: This study aims to determine the value of the coefficient with a short term duration and a variable test time span.  Several ways and methods of determining the rate of deoxygenation are developed according to the characteristics of the river and the environment. Modification method was applied in this research in which the test time span was unequal. The river chosen in this study is the Citepus River, Bandung, Indonesia representing an urban river in a tropical country. Methodology and Results: Sampling was carried out in the dry season. The laboratory analysis method used in determining the rate of deoxygenation uses the Slope Method of data from the short term incubation, which is ten days. The results showed that the Thomas Slope method's deoxygenation rate (K1) was 0.095 per day in the upstream segment, 0.917 per day in the middle segment, and 0.180 per day in the downstream segment. While the Ultimate BOD (La) value is 46.95 mg/l in the upstream segment, 38.70 mg/l in the middle segment, and 37.60 mg/l in the downstream segment. Conclusion, significance, and impact of study: The results of this study show that the value of the deoxygenation rate is similar to the theoretical surface water conditions. However, in the upstream segment, there is still a low deoxygenation rate value due to non-optimal activity of microorganisms. This findings will be very useful both in water quality modeling and river management.
TEMPORAL VARIATION OF GROUNDWATER QUALITY IN SLEMAN, YOGYAKARTA, INDONESIA Wijayanti, Yureana; Fittkow, Markus; Kusumadewi, Riana Ayu; Setyandito, Oki
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10746

Abstract

Groundwater quality evaluation is important to gain an insight of contamination source. It can later be utilized to review the implementation of a water resource management policy in a specific region. Aim: This study evaluate the short-term temporal variation of groundwater quality and its possible contamination source in Sleman, Yogyakarta. Methodology and Results: the statistical approach was utilized using boxplot, principle component analysis (PCA) and correlation matrices, to the data for 50 sampling sites. The data of groundwater quality are available from the local environmental authority of Environmental Agency Sleman.The box plots revealed that groundwater quality might largely influenced by rainfall in the area. The factor loading of PCA presented that the ratio of concentration of both chloride and TDS are the most varied of all samples, and the less variable parameter is fluoride. The pair of groundwater quality parameter which had strong correlation were varied in each year, except for TDS and chloride that showed strong correlation in all three years. Nitrite had strong correlation with iron in 2017 and, nitrite also had strong correlation with both manganese and fluoride in 2019. The existence of fluoride in correlation with other parameter might give an insight of contamination from livestock wastes, where in the study area there are many poultry and cow farms, and small scale chicken slaughter industries. Conclusion, significant and impact study: This study gives preliminary understanding on temporal variation of groundwater quality, for further research on groundwater quality in Sleman, Yogyakarta.
HEAVY METAL POLLUTANT SORPTION IN AQUATIC ENVIRONMENT BY MICROALGAE CONSORTIUM Rinanti, Astri; Fachrul, Melati Ferianita; Hadisoebroto, Rositayanti; Desty, Sinthya; Rahmadhania, Rahmadhania; Widyaningrum, Della Annisa; Saad, Noor Aida
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10747

Abstract

Industrial waste that contains heavy metal can cause environmental problem because of its toxicity, persistency and accumulation level in the environment. Biosorption process is highly influenced by temperature, pH, light, contact time, and ratio of surface area. Microalgae which possess two functional groups that are able to react on metal ion in a solution can be exploited to overcome environmental pollution due to heavy metal compound. Closed cultivation system in a photobioreactor is utilized to overcome contamination and evaporation problems on open pond system. Heavy metal analysis is conducted by utilizing Atomic Absorption Spectroscopy (AAS), Fourier Transform Infra-Red (FTIR), and Scanning Electron Microscope (SEM). This article provides information on biosorption as alternative technology to overcome heavy metal in water areas with no side effects on the environment with advantages of the absence of secondary pollutants, high level of efficiency, and relatively economic compared to physic-chemical method heavy metal removal methods
RAW WATER QUALITY ANALYSIS TO DISCOVER THE CAUSE OF PIPELINE SCALLING PROBLEM IN PT. X (ICE PRODUCTION COMPANY) Harmayani, Kadek Diana; Sudiartha, Gede Adi Wiguna; Suyasa, I Wayan Budiarsa
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10748

Abstract

PT. X is one of the ice companies in which its largest company is located in Bali, more precisely in the Pidada area, North Denpasar. Based on field observations the area is an area that has a calcareous soil structure. The water source of PT. X was extracted from the groundwater. From the field observation, it was found that the pipeline network, that connected the inlet water to water treatment system and ice production units, was severely covered by faint white scale. In order to discover the origin of this scale, water quality testing need to be carried out.  From the results, it was found that the total hardness in the inlet water, taken from the groundwater tap, was 162.85 mg/l with calcium concentration of 2.15 mg/l and iron 3.83 mg/l. Water quality testing was also carried out in the water treatment unit consisting of resin softener where the total hardness surprisingly increased into 279.81 mg/l, calcium concentration was 2.96 mg/l, iron concentration was 0.55 mg/l. Even after being treated in softener resin, the total hardness increased sharply to 483 mg/l, which categorized as extreme hardness. The increase in total hardness indicates that there was a failure in the operation of the water treatment system, even it also contributed to the higher hardness and calcium concentration. This over-year’s treatment failure has been causing accumulation of hardness and calcium concentration in the compartment of both water treatment system and ice production unit that inflicts a higher hardness level in the effluent.
DEGRADATION OF POLYETHYLENE PLASTIC WASTE BY INDIGENOUS MICROBIAL CONSORTIUM AND FUNGI Fachrul, Melati Ferianita; Rinanti, Astri; Tazkiaturrizki, Tazkiaturrizki; Salmiati, Salmiati; Sunaryo, Thalia
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10749

Abstract

Aim: The aims of this research is to determine the ability of an indigenous microbial consortium to degrade Low Density Polyethylene plastics. The plastic was cut mechanically into 1 x 1 cm2 pieces because the smaller the size of the plastic, the larger the surface area. The samples are input in an Erlenmeyer flask containing indigenous microbial consortium and fungi (20% v/v) and Stone Mineral Salt solution media (80% v/v). This research lasted 10 days with a pH of 7 controlled and temperature variations of 25, 30, 35°C. As preliminary research, the sensitivity test seeks to demonstrate that the indigenous microbial consortium and fungi are resistant or insensitive to LDPE. The degradation of LDPE plastic was analyzed using gravimetric methods, Fourier Transform Infrared, and a scanning electron microscope. Methodology and results: According to the results of gravimetric and FTIR analysis, the highest removal value was at a temperature variation of 30°C. The gravimetric analysis revealed that the weight loss in LDPE plastic was 0.0082 gr to 0,0074 gr or 9.76 %, while the FTIR analysis revealed that the intensity removal result was 6,27 %. Conclusion, significance, and impact of study: Scanning Electron Microscope (SEM) analysis revealed morphological changes on the surface of LDPE plastic samples, confirming these findings. Several factors influence the changes that occur in this study's LDPE plastic samples.
ANALYSIS OF RESIDUAL CHLORINE CONCENTRATION IN DISTRIBUTION NETWORK OF DRINKING WATER SUPPLY AT ISTANA DIENG II RESIDENCE OF MALANG, EAST JAVA, INDONESIA Bahrudin, Moh. Zainal; Yulistyorini, Anie; Rahayuningsih, Titi
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 3, OCTOBER 2022
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i3.12463

Abstract

The drinking water distribution network in Istana Dieng residence is categorized as an isolated network because it does not connect with the other water distribution networks provided by the Malang Water Company (Perusahaan Daerah Air Minum, PDAM). For this reason, the residual chlorine of the isolated distribution network needs to be monitored regularly. Aim: This study aims to observe residual chlorine distribution patterns and investigate the effect of distribution distance, pH, and temperature on residual chlorine concentration in the water distribution network. Methodology and Results: Analytical survey method with a cross-sectional approach was used in this study. The field survey results and the water analysis were inputted into the ArcGIS 10.6 software to generate an Isoconcentration map. Correlation and regression analysis were conducted using SPSS 16.0. Conclusion, significance and impact of study: The results showed that 65% of the residual chlorine concentration in the drinking water distribution network Istana Dieng residence did not meet the quality standard (<0.2 mg/l). Twenty-six sample points showed a value of 0.1 mg/l, which was caused by the pipe's physical condition and the use of wells connected to the PDAM network. There was a significant correlation between distance and residual chlorine concentration. The significant correlation between pH and residual chlorine concentration showed a value of -0.690. The correlation between temperature and residual chlorine concentration was -0.633. It was proven that the lower the residual chlorine concentration, the higher the pH and temperature values in the distribution network.
THE POTENTIAL CIBERANG RIVER ANALYSIS FOR DRINKING WATER SUPPLY DEVELOPMENT OF BANTEN PROVINCE Mulyawati, Ira; Salami, Indah Rachmatiah Siti; Sabar, Arwin; Marselina, Mariana; Nasir, Hernita
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 2, APRIL 2022
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i2.12589

Abstract

Aim: This study was aimed to analyze the potential of water sources in the Ciberang River to support drinking water supply system of Banten Province. Methodology and results: The method use to analyze the potential of Ciberang river is a hydrological statistical analysis. The results of the hydrological statistical analysis show that the water resources of the Ciberang River are not sufficient to meet domestic and industrial water needs in Banten Province. Domestic and industrial water demand in Banten Province in 2025 is estimated at 14.64 m3/s and 10.46 m3/s, respectively, while the mainstay discharge with the return period of 10 and 20 year for all durations does not meet these water needs. The mainstay discharge of the Ciberang River with a 10-year return period of 1, 2, 7, 15 and 30 day respectively was 0.08 m3/s, 0.1 m3/s, 0.19 m3/s, 0.36 m3/s, and 0.87 m3/s. The mainstays of the 20-year return period of 1,2,7,15 and 30 day respectively are 0.04 m3/s, 0.06 m3/s, 0.11 m3/s, 0.23 m3/s and 0.59 m3/s. Conclusion, significance, and impact study: Based on this, it is necessary to conserve water resources to increase the main flow of the Ciberang River. One of the strategic policies to increase the river's mainstay discharge is constructing the reservoir.
DOMESTIC WASTEWATER TREATMENT USING VERMIFILTER COMBINED WITH CANNA INDICA Sutrisno, Joko; Nurhayati, Indah; Al Kholif, Muhammad; Rahmaniasari, Dinda
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 3, OCTOBER 2022
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i3.12752

Abstract

Untreated domestic wastewater can pollute the aquatic ecosystem. Vermifilter integrated with the Canna indica plant is one of the technological alternatives that can be used to treat domestic wastewater. One of affecting the performance of vermifilters is the vermibed media. Aim: This study aims to examine the effect of vermibed material on the concentration of COD, TP, DO, and the pH value of domestic wastewater treated with vermifilter combined with Canna indica plants. Methodology and Results: The research was conducted on a laboratory scale with a a continuous system using a plastic reactor dimension of 59 x 38 x 29 cm, which is filled with sand filter media, coconut fiber, gravel, and vermibed. The vermibed reactor consists of 4 reactors including reactor 1 (R1) vegetable vermibed, reactor 2 (R2) sawdust, reactor 3 (R3) banana peel, and reactor 4 (R4) cow dung. The results showed that  at the end of the research, the best performance is showed by reactor R2 that able to decrease COD 94.81%, TP 92.07%, DO increase 320.00%, pH 6.30±0.10.  Vermibed sawdust (R2) can lower COD, TP and raise DO higher to treat domestic wastewater by combining vermifilter with Canna indica plant.  Conclusion, significance, and impact study:  Vermifilter with Canna indica plant is an effective wastewater treatment in reducing COD, TP, increasing DO and pH value.   This treatment is easy processing of operation and maintenance, does not require large land, can be done on an individual scale, and is environmentally friendly.
ORGANIC REMOVAL IN DOMESTIC WASTEWATER USING ANAEROBIC TREATMENT SYSTEM-MBBR WITH FLOW RECIRCULATION RATIO AND INTERMITTENT AERATION Subroto, Michael; Prayogo, Wisnu; Soewondo, Prayatni; Setiyawan, Ahmad Soleh
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 3, OCTOBER 2022
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i3.12776

Abstract

Aim: The modified Small-scale Domestic Sewage Treatment Plant (SDSTP) reactor with anaerobic fixed bed- aerobic Moving Bed Biofilm Reactor (MBBR) is implemented to find the optimum condition for organic degradation related to recirculation and intermittent aeration practices with the purpose to comply with the governmental regulation standard.  Methodology and Results: This research have been done with the artificial wastewater with characteristic similar to the sewage treatment plant (STP) of Telkom company with ratio C:N:P of characterized domestic wastewater is 252.40:85.42:3.01 that consists of glucose, NH4Cl, potassium dihydrogen phosphate, potassium nitrate, and sodium nitrite (NaNO2). Reactor design related with attached biomass in media until 2478.56 mg MLVSS.L-1 with the growth kinetics rate (μ) of 0.4691 day—1. The artificial wastewater is applied the determine the optimum variation of flow recirculation and periodic aeration in specific Hydraulics Retention Time (HRT) and Organic Loading Rate (OLR). In this research, the optimum recirculation ratio for organic degradation is 26.40 L.h-1 and the optimum aeration frequency variation is  12 hours in intermittent frequency with the maximum efficiency of organic degradation of 76.10% with the degradation efficiency real domestic wastewater application from STP Telkom company is 83.09%. Conclusion, significance and impact study:  Stover-Kincannon model is the best model with highest accuracy rate to model the degradation performance of organic compounds by the anaerobic fixed bed- aerobic MBBR SDSTP with determination coefficient 0.8623 and also degradation coefficient 38.121 day-1 compared with other models studied in this research.