Modified Doppler Healthy Pregnancy Monitoring (MODEM-KES) to speed up examinations of pregnant women Cory’ah, Fitra Arsy Nur; Suseno, Mutiara Rachmawati; Faiqah, Syajaratuddur; Megantari, Ayu Dini; Amrinsani, Farid
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 7 No. 2 (2025): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v7i2.39

Abstract

Monitoring fetal health is a major factor in ensuring a healthy pregnancy and safe delivery. However, in Indonesia, especially in remote areas, limited access to quality health services, lack of sophisticated medical equipment, and difficulty reaching health facilities are serious challenges that contribute to high maternal and infant mortality rates. This study developed MODEM-KES (Modified Doppler Healthy Pregnancy Monitoring) which aims to evaluate the effectiveness of MODEM-KES in supporting health workers, especially midwives in remote areas, in conducting pregnancy monitoring more practically, accurately, and quickly. This tool integrates three important indicators: gestational age estimation, fetal weight estimation, and fetal heart rate, using Doppler sensors and fundus uteri height (FUH) measurements combined with digital methods. The research method involved testing the MODEM-KES prototype against standard tools, such as metline for FUH measurement and Doppler for FHR, with five measurements on each respondent with a gestational age of 26-40 weeks. Results showed that the difference in results between MODEM-KES and standardized tools was relatively small: FUH had a difference of 0-3 cm with an error rate of 0%-10.75%, FHR had a difference of -4/min to 4/min with an error rate of -3.0%-3.1%, and estimated fetal weight had a difference of 0-465 grams with an error rate of 0%-18.8%. Although the accuracy rate varies, MODEM-KES still shows potential as an alternative pregnancy monitoring tool that is practical and easy to use.
Comparison of Pressure Sensor in Flow Analyzer Design for Peep Measurement on Ventilators Wakidi, Levana Forra; Amrinsani, Farid; Zeha, Alfi Nur; Dewiningrum, Riqqah; Nyatte, Steyve
Jurnal Teknokes Vol. 16 No. 4 (2023): December
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Flow Analyzer allows measurement of flow, pressure, volume, and oxygen concentration delivered to the patient, with PEEP (Positive End Expiratory Pressure) being a crucial parameter in mechanical ventilation. Incorrect PEEP values can elevate the risk of patient mortality. The recommended PEEP range is 5-24 cmH2O, and administration is determined by the patient's clinical condition. This research aims to identify stable and highly accurate pressure sensors by comparing the MPX2010DP and MPX5010DP sensors with pressure readings from a Digital Pressure Meter (DPM). The study involves 5 repetitions of a lung test, each with 11 pressure reading points, within a pressure measurement range of 0-30 cmH2O. The DPM has a resolution of 1 cmH2O, while both pressure sensors have a resolution of 0.01 cmH2O. Results indicated that the MPX2010DP sensor has the smallest error percentage, specifically 0.00%, at a pressure increase of 5 cmH2O and 20 cmH2O. Conversely, the MPX2010DP sensor shows the largest error percentage, 5.16%, when the pressure decreases by 5 cmH2O. The highest standard deviation of 0.52 is observed in the MPX5010DP sensor at a 20 cmH2O pressure increase, while the maximum correction value of 0.54 is found in the MPX5010DP sensor at a 25 cmH2O pressure increase. According to the ANOVA test, there is no significant difference in pressure produced between the MPX2010DP sensor, MPX5010DP sensor, and DPM. The sensors are well-calibrated and provide accurate readings according to calibration tool standards. Therefore, the MPX2010DP and MPX5010DP sensors are deemed accurate for measuring PEEP parameters in ventilators. Based on the obtained data, it can be concluded that the MPX2010DP sensor is more accurate and stable.
Analysis of Changes in Flow Setting Against Rise Time Using Gas Board 7500E Sensor on Bubble CPAP Pudji, Andjar; Amrinsani, Farid; Luthfiyah, Sari; Lusiana, Lusiana; Misra, Shubhrojit; Ahniar, Nur Hasanah; Barus, Yenda Mita; Lamidi , Lamidi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 2 (2022): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.143

Abstract

Respiratory distress syndrome (RDS) is a breathing disorder that occurs in newborns, often in premature babies born before 28 weeks of gestation. The bubble CPAP (Continuous Positive Airways Pressure) is a device used to provide positive pressure to newborns who can breathe spontaneously but are still prone to apnoea. The rise time is the time it takes for the airway pressure to reach the maximum standard value. The aim of this study is to analyze the changes in flow regulation during the rise time using a 7500E gas sensor card on a bubble CPAP probe. The method used in this study is to use the mean hijacking of the sensor to reduce the noise generated by the sensor. When analyzing the data, the researcher recorded data up to five times and calculated the mean measurement error. The research design is calibrated to confirm the correctness of the displayed values. The results of the data analysis are a mean error value of 0.88% at a setting of 30% oxygen content, 0.78% at a setting of 50%, and 0.95% at a setting of 90%. For liters per minute (LPM) at the 1 LPM and 5 LPM settings, the mean error values are 0.18 % and 0.03 % for the 10 LPM setting. From the test results with 3 bubble CPAP devices, it appears that when a high LPM setting is used, the oxygen concentration is reached faster with a mean value of ±10 seconds. The conclusion from this study shows that increasing the oxygen flow rate affects the duration of the rise in bubble CPAP oxygen concentration. The implication of this study is that this data will help add artificial intelligence to bubble CPAP to automatically determine settings by combining breathing data from patients.
Detection of Electromyography Signal using Dry and Disposable Electrodes on the Bicep Muscle While Lifting Weights Amrinsani, Farid; Wakidi, Levana Forra; Suryanta, Made Dwi Pandya; Wulandari, Dessy Tri; Sadiq, Muhammad Tariq
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 4 (2022): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.153

Abstract

One of the biosignals used to identify human muscle impulses is electromyography. Electromyographic signals are often used as input and are designed to help people with disabilities or help the healing process after stroke therapy. According to research, this incident has led to the development of various electromyography module sensor designs to meet different purposes. This research was conducted to make two different electromyography module designs and test these modules simultaneously when the biceps lifted a weight of 3Kg. The aim of this study was to compare the use of disposable and dry electrodes from the two electromyographic sensor module designs that were made. using root mean square (RMS) to find out the difference in tension generated when lifting the barbell. each module detects the biceps signal simultaneously. The biceps are part of the upper limb muscles. Based on the findings of this study, both E1 and E2 electromyography modules with disposable electrodes produced data with a p-value of 0.001766368 less than 0.05. while for the t-test of the two Electromyography modules E1 and E2 with dry electrodes it is 0.001766368 which is less than 0.05. Therefore, it can be concluded that there is a significant difference between the E1 and E2 modules. there is an average amplitude difference of 10mV between E1 and E2 modules when using both types of electrodes. and there is a difference in the average amplitude using dry and disposable electrodes of 30mV. The results of this study can be used to provide insight into the detection of electromyography signals, while the two module designs developed can be applied in future studies to detect electromyography.
Comparison of Two Designs of Wireless Electromyography Sensor Module Using Disposable Electrodes and Dry Electrodes in a Sit to Stand Motion Amrinsani, Farid; Wakidi, Levana Forra; Suryanta, Made Dwi Pandya; Wulandari, Dessy Tri; Caesarendra, Wahyu
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 4 (2022): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.155

Abstract

Electromyography is one of the biosignals used to detect muscle signals in humans. Electromyography signals are widely used as input and are engineered to help people with disabilities or assist them in post-stroke therapy recovery. Based on this phenomenon, a lot of electromyography module sensor designs were made to support various purposes in accordance with research. The purpose of this study was to compare the electromyography sensor module using a disposable electrode and a dry electrode using a wireless serial communication system. The results of this study was based on the experiment carried out in the movement from sitting to standing. Therefore, the difference would be more visible by looking at the Mean Power (MNP) value than the mean frequency (MNF). In this case, the tests were conducted using a disposable electrode, all Bluetooth test distances, relaxed conditions with a mean power value of 0.000453, and contraction with a mean power value of 0.000494. In addition, the researchers also compared serial communication transmissions using cables in relaxed conditions with a mean power value of 0.000460 and contraction with a mean power value of 0.000496. Furthermore, trials were further conducted using dry electrodes, all Bluetooth test distances, relaxed conditions with a mean power value of 0.000455, and contraction with a mean power value of 0.000503. In this case, the researchers compared serial communication transmissions using cables in relaxed conditions with a mean power value of 0.000454 and contraction with a mean power value of 0.000499. It was concluded that the design built and analyzed using mean power (MNP), obtained results that were not much different between electromyography modules using wired and wireless serial communications. It was also obtained that the electromyography module design in this study had no problem with the information.
Low Cost Health Monitoring Sytem Based on Internet Of Things Using Email Notification Wisana, I Dewa Gede Hari; Utomo, Bedjo; Amrinsani, Farid; Purwanto, Era
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 2 (2021): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.202

Abstract

Monitoring activities are needed if there are symptoms of a disease that require quick action so that the patient's condition does not get worse, for that we need a system that can notify doctors so they can take action. The patient monitoring system in hospitals is generally still carried out conventionally, among others, nurses or doctors come to the patient's room to check on the progress of the patient's condition, this will be a problem, if the number of medical personnel and facilities is insufficient to monitor. Patients who need special attention for patient care, such as monitoring the patient's breathing rate. The use of the internet of things (IOT), as a device that can work without the help of people, can perform tasks and provide easier and real time data, so that they can access output directly. The purpose of this research is to design an inexpensive health monitoring tool based on the Internet of Things (Respiration Parameters) using a piezoelectric sensor and an ESP32 Wi-Fi module. From the results of the module design taken from 10 respondents, obtained that the average measurement high accuracy (17.76 + 0.61) and the average level of stability of the design has a magnitude of 0.4 so that it can be concluded that using a piezoelectric sensor in this series can obtain good accuracy. This the design can be used to monitor a person's respiration in real-time
Penerapan Sistem Pemantauan Kelistrikan dan SOP Pemeliharaan Autoklaf di Puskesmas Tarik 2, Kabupaten Sidoarjo, Jawa Timur Levana Forra Wakidi; Lusiana; Farid Amrinsani; Oskar Natan; Roichatun Nashichah
Jurnal Pengabdian Masyarakat Indonesia Vol 5 No 5 (2025): JPMI - Oktober 2025
Publisher : CV Infinite Corporation

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52436/1.jpmi.4107

Abstract

Autoclave merupakan peralatan utama dalam proses sterilisasi di fasilitas pelayanan kesehatan. Di Puskesmas Tarik II Kabupaten Sidoarjo, diperlukan pemantauan sistem kelistrikan secara berkala untuk memastikan keandalan dan keamanan fungsi autoclave dalam proses sterilisasi. Kegiatan ini bertujuan meningkatkan kompetensi petugas puskesmas dalam melakukan pemantauan kelistrikan melalui kegiatan pengujian dan kalibrasi autoclave guna menjaga efisiensi dan kinerja alat. Program dilaksanakan melalui skema Kemitraan Masyarakat antara Poltekkes Kemenkes Surabaya Jurusan Teknologi Elektro-Medis dan Puskesmas Tarik II. Metode kegiatan meliputi survei sistem kelistrikan, pengujian dan kalibrasi autoclave bersama PT Gama Medika Teknik menggunakan Metode Kerja GMT/MK/TEKNIK.009-18 yang mengacu pada Keputusan Dirjen Pelayanan Kesehatan No. HK.02.02/V/0412/2020 Edisi II, pelatihan teknis, serta penyusunan dan penerapan Standar Operasional Prosedur (SOP). Pengujian mencakup aspek kelistrikan (resistansi pembumian, arus bocor, dan resistansi isolasi), serta suhu dan waktu sterilisasi pada setpoint 115 °C. Hasil menunjukkan autoclave memenuhi standar keselamatan dan dinyatakan laik pakai (label hijau). Kegiatan ini berdampak pada pencegahan kerusakan alat, peningkatan pengetahuan teknis petugas, dan dukungan terhadap akreditasi Puskesmas, sehingga meningkatkan keandalan peralatan dan mutu layanan sterilisasi di fasilitas kesehatan.
Temperature response analysis between PD and PI controls applied to infant incubators Abd. Kholiq; Lamidi Lamidi; Farid Amrinsani; Anisia Yunita Maulani Argumery; Hafizh Aushaf Mahdy
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 2: April 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i2.25879

Abstract

Premature infants, born with low birth weight, require specialized care and isolation due to their vulnerability to infections in public settings. Baby incubators, classified as life support equipment, play a crucial role in safeguarding these infants by maintaining a consistent temperature and humidity similar to the mother’s womb. This study compares the temperature control systems in baby incubators, specifically proportional and derivative (PD) control versus proportional and integral (PI) control. LM35 and DS18B20 sensors were employed in the study. Results from PD control using the LM35 sensor show a rise time of 5 min and 40 sec, a settling time of 25 min, and an overshoot of 2.2 °C. The DS18B20 digital sensor, under PD control, achieves a rise time in 6 min and 30 sec, a settling time of 23 min, with an overshoot of 1.2 °C. For PI control with the LM35 sensor, there’s a 3 °C overshoot, a 5-minute rise time, and a 30-minute settling time. The DS18B20 sensor under PI control exhibits a 2.7 °C overshoot, a 5-minute rise time, and a 29-minute settling time. PD control demonstrates lower overshoot and faster response but longer rise times than PI control. Future research explores fuzzy control systems and proportional integral derivative (PID)-fuzzy hybrid control.
Effectiveness of Bluetooth communication of digital stethoscope using quality of service method Endang Dian Setyoningsih; Sumber Sumber; Triwiyanto Triwiyanto; Farid Amrinsani
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 4: August 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i4.25882

Abstract

This study aims to design and evaluate a wireless electronic stethoscope that can transmit heart sound using Bluetooth HC-05 and Bluetooth 5.0 transmitter. This novel design contributes to the remote diagnosis and monitoring of heart conditions, especially for patients with infectious diseases. The heart sound signals are captured using a mic condenser mic, amplified, filtered, and converted to digital data by a microcontroller. The data are then transmitted by Bluetooth HC-05 to a module and by Bluetooth 5.0 transmitter to a headset. The quality-of-service parameters such as throughput, delay, and packet loss ratio (PLR) of the data transmission at different distances are measured. The results show that the wireless electronic stethoscope can transmit heart sound data with a small PLR of 0.10% and a throughput of 1002.5 bps. The study concludes that the wireless electronic stethoscope is an effective and useful device for examining heart conditions remotely, without compromising the functionality of the device
Evaluating the effectiveness of digital filtering techniques in electronic stethoscopes: a study of Kalman and Butterworth filters Endang Dian Setioningsih; Sumber Sumber; Triwiyanto Triwiyanto; Vugar Abdullayev; Farid Amrinsani; Bima Maulana Raharjo; Tetrik Fa’altin
Bulletin of Electrical Engineering and Informatics Vol 15, No 2: April 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i2.8674

Abstract

Heart sound, or phonocardiogram (PCG), signals are often distorted by noise from respiration, movement, and the surrounding environment, which complicates accurate cardiac feature extraction in portable monitoring systems. This study aims to design and evaluate an effective digital filtering method to enhance PCG signal quality obtained from a low-cost acquisition system based on a condenser microphone sensor and an ESP32 microcontroller. The main contribution of this work is the implementation and comparison of two noise-reduction approaches: Butterworth band-pass filters of various orders and the Kalman filter applied to PCG signals acquired from mannequin-based simulations. Data were recorded for 10 seconds at a 1000 Hz sampling rate, processed in MATLAB, and analyzed using the fast Fourier transform (FFT) to determine the optimal frequency ranges. Experimental results demonstrate that the 8th-order Butterworth band-pass filter achieved the highest signal-to-noise ratio (SNR) improvement, averaging 25.659 dB, outperforming other configurations. These findings indicate that an appropriately tuned Butterworth filter provides a simpler yet robust solution for real-time PCG denoising in embedded systems. Future work will integrate the filtering process directly into the ESP32 firmware and evaluate its performance on human subjects to enhance clinical applicability.