Dhofir, Mochammad
Jurusan Teknik Elektro Fakultas Teknik Universitas Brawijaya

Published : 84 Documents Claim Missing Document
Claim Missing Document
Check
Articles

PERENCANAAN PENERANGAN JALAN UMUM DENGAN SISTEM PEMBANGKIT LISTRIK TENAGA SURYA TERPUSAT DI KAMPUS II UNIVERSITAS BRAWIJAYA Aldian Eka Fitranto; Unggul Wibawa; Mochammad Dhofir
Jurnal Mahasiswa TEUB Vol 7, No 5 (2019)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The Solar Power Plant is one of the power plants that uses renewable energy solar insulation as its energy source. In this paper, Solar Plant at Campus II Brawijaya University uses a centralized system that supplies loads in the form of public street lighting, where it is not connected to the electricity network and uses an inverter as a converter of solar panels consisting of direct current (DC) to street light loads consisting of alternating current (AC) . The results show that Centralized Solar Plant with a capacity of 10 kWp is capable of supporting 38 street lights for 10.7802 hours. Keywords— Renewable energy, PLTS, PJU. Abstrak—Pembangkit Listrik Tenaga Surya (PLTS) merupakan salah satu pembangkit listrik yang menggunakan energi terbaharukan insolasi matahari sebagai sumber energinya. Pada paper ini, PLTS di Kampus II Universitas Brawijaya menggunakan sistem Terpusat yang mensuplai beban berupa penerangan jalan umum, dimana tidak terhubung ke jaringan listrik dan menggunakan inverter sebagai konverter dari panel surya berupa arus searah (DC) ke beban PJU berupa arus bolak-balik (AC). Hasil menunjukan bahwa PLTS Terpusat dengan kapasitas 10 kWp mampu menyalakan 38 titik lampu selama 10,7802 jam. Kata Kunci—Energi terbaharukan, PLTS, PJU.
PENGARUH BOMBARDIR PARTIKEL BERMUATAN PADA PERMUKAAN PLAT MENGGUNAKAN HVDC Dandhi Tri Laksono; Mochammad Dhofir; Rini Nur Hasanah
Jurnal Mahasiswa TEUB Vol 6, No 3 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pada buku skripsi ini menguraikan hasil penelitian tentang pengaruh bombardir partikel bermuatan pada permuakaan plat menggunakan HVDC. Data yang diambil dalam pengujian ini berupa, tegangan korona (Uc) dan tegangan tembus (Ud), serta berupa gambar plat dengan perbesaran sampai partikel dengan menggunakan alat scanning electron microscope (SEM). Setiap satu kali pengukuran dilakukan pergantian elektroda plat guna untuk melihat mikrostruktur permukaan plat akibat pengaruh bombardir partikel bermuatan. Setiap hasil pengujian dilakukan analisis untuk mengetahui besar energi kinetik partikel bermuatan. Pada penelitian ini dilakukan metode pengujian meliputi pengujian pengaruh bombardir dengan polaritas positif dan jarak sela 3 cm didapatkan tegangan 25kV, 25,20kV, 25,80kV, 26,20kV, 27kV memiliki energi kinetik 0,2260eV, 0,2277eV, 0,2333eV, 0,2369eV, 0,244eV. pengujian pengaruh bombardir dengan polaritas positif dan jarak sela 5 cm didapatkan tegangan 28,54kV, 29,35kV, 30,70kV, 33,10kV, 41kV memiliki energi kinetik 0,1998eV, 0,2055eV, 0,2149eV, 0,2317eV, 0,2870eV. pengujian pengaruh bombardir dengan polaritas negatif dan jarak sela 3 cm didapatkan tegangan 22,30kV, 22,40kV, 23,20kV, 23,80kV, 25,90kV memiliki energi kinetik 0,2016eV, 0,2026eV, 0,2098eV, 0,2152eV, 0,2342V.pengujian pengaruh bombardir dengan polaritas negatif dan jarak sela 5 cm didapatkan tegangan 29,17kV, 29,75kV, 32,75kV, 33,74kV, 40kV memiliki energi kinetik 0,2042eV, 0,2083eV, 0,2293eV, 0,2362eV, 0,28eV . Hasil dari penelitian yang telah dilakukan didapatkan kesimpulan bahwa kenaikan secara linier terjadi pada energi kinetik partikel bermuatan (Ek) dari tegangan korona mulai muncul sampai tegangan tembus. Hal ini dikarenakan semakin besar tegangan maka kecepatan elektron semakin besar dan semakin besar pula energi kinetik partikel bermuatan. Selain itu, untuk hasil pengujian kawat pada polaritas positif hasil gambar pada mikrostruktur permukaan plat memiliki bentuk gambar banjiran muatan yang sedikit dan memiliki ukuran diameter lebih besar. pada polaritas negatif hasil gambar mikrostruktur permukaan menunjukkan banjiran muatan lebih banyak dan memiliki ukuran diameter lebih kecil. Kata kunci: Energi kinetik partikel bermuatan, efek bombardir, Polaritas tegangan, scanning electron microscope(SEM) ABSTRACT                     In this thesis book describes the results of research on the effect of bombardment of charged particles on plate peluakaan using HVDC. The data taken in this test are the corona (Uc) and translucent (Ud) stresses, as well as the plate drawing with magnification to the particles using a scanning electron microscope (SEM) device. Every single measurement is done the replacement of plate electrode in order to see plate surface microstructure due to the effect of bombarded charged particles. Each test result is analyzed to find out the magnitude of kinetic energy of charged particles. In this research, the test method includes testing the effect of bombardment with positive polarity and spacing of 3 cm obtained 25kV, 25,20kV, 25,80kV, 26,20kV, 27kV have kinetic energy 0,2260eV, 0,2277eV, 0,2333eV, 0.2369eV, 0.244eV. testing the effect of bombardment with positive polarity and spacing of 5 cm obtained voltage 28,54kV, 29,35kV, 30,70kV, 33,10kV, 41kV have kinetic energy 0,1998eV, 0,2055eV, 0,2149eV, 0,2317eV, 0 , 2870eV. testing the effect of bombardment with negative polarity and spacing of 3 cm obtained voltage 22.30kV, 22,40kV, 23,20kV, 23,80kV, 25,90kV having kinetic energy 0,2016eV, 0,2026eV, 0,2098eV, 0,2152eV , 0,2342V. The test of bombarding effect with negative polarity and 5 cm spacing is obtained voltage 29,17kV, 29,75kV, 32,75kV, 33,74kV, 40kV have kinetic energy 0,2042eV 0,2083eV 0,2293eV, 0.2362eV, 0.28eV. The result of the research has been found that the linear rise occurs in the kinetic energy of charged particles (Ek) from the corona voltage begins to appear until the voltage breaks. This is because the greater the voltage the greater the electron velocity and the greater the kinetic energy of charged particles. In addition, for the test results of the wire on the positive polarity of the image on the plate surface microstructure has the shape of the image flooded a little and has a larger diameter size. on the negative polarity of the surface microstructural image shows more flood load and has smaller diameter size.Keywords: Kinetic energy of charged particles, bombardment effects, voltage polarity, scanning electron microscope (SEM).
Perancangan Dan Pembuatan Model Miniatur Electrostatic Precipitator (Pengendap Debu Elektrostatis) Untuk Mengurangi Partikel Debu Gas Buang Pabrik Gula Krebet Baru I Kabupaten Malang Agung Firmansyah Sunardi; Mochammad Dhofir; n/a Soemarwanto
Jurnal Mahasiswa TEUB Vol 1, No 1 (2013)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (484.69 KB)

Abstract

Penyumbang polusi udara salah satunyaadalah hasil emisi proses industri. Banyak regulasi yangdikeluarkan pemerintah untuk mengendalikan hasil emisiini.. Untuk memenuhi aturan tersebut dibutuhkanteknologi yang dapat menangani permasalahan polusi ini.Salah satu teknologi tersebut adalah ElectrostaticPrecipitator. Metode ini menggunakan medan listrikuntuk mengionisasi partikel debu sehingga partikel debutersebut dapat menempel pada elektroda plat pengumpul.Skripsi ini nantinya akan membahas perancangan danpembuatan model miniatur electrostatic precipitator untukmengendapkan partikel debu hasil gas buang PG KrebetBaru Malang. Di dalam perancangan dan pembuatanmodel miniatur EP ada beberapa parameter yangdibutuhkan yaitu, kuat medan listrik, tegangan tembus,tegangan kerja, pemuatan partikel, kecepatan gerakpartikel, serta efisiensi yang diinginkan. Dari hasilperancangan, untuk mendapatkan efisiensi 99%dibutuhkan total luas plat pengumpul 287,214 m2, jumlahplat pengumpul yang digunakan 10 buah, jumlahelektroda kawat 360 buah, dimensi ruang adalah 13 x 2 x6 m, serta tegangan kerja yang dibutuhkan 55 kV.
PENGARUH BOMBARDIR PARTIKEL BERMUATAN PADA PERMUKAAN PLAT TEMBAGA DENGAN DIELEKTRIK UDARA MENGGUNAKAN HVDC POLARITAS POSITIF DAN NEGATIF Ilham Ismail Mochsen; Mochammad Dhofir; Teguh Utomo
Jurnal Mahasiswa TEUB Vol 8, No 5 (2020)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pada setiap pengujian yang menggunakan peralatan tegangan tinggi, peralatan akan menghasilkan medan listrik tinggi. Akibat dari adanya medan listrik ini membuat elektron dan ion bergerak dan akan menghasilkan proses ionisasi dengan cara bertabrakan dengan molekul bebas yang ada disekitar medan. Selama masih adanya medan listrik elektron dan ion akan terus bergerak hingga menumbuk permukaan katoda dan menyebabkan fenomena bombardir partikel bermuatan. Penelitian ini dilakukan untuk mengetahui efek dari bombardir partikel bermuatan pada katoda berbahan tembaga terhadap dielektrik udara. Tekanan dielektrik udara divariasi dari 558 mBar hingga mencapai tekanan normal. Diketahui bahwa pada perubahan tekanan mempengaruhi jarak bebas partikel bermuatan sebelum bertubrukan, sedangkan nilai tegangan dengan jarak sela mempengaruhi seberapa cepat energi kinetik partikel bermuatan ketika bombardir terjadi. Bombardir partikel terjadi ketika nilai tegangan cukup untuk menyebabkan elektron bergerak dengan kecepatan antara 12,08eV - 15,52 eV yang merupakan syarat ionisasi pada udara yang mana partikel gas terbanyak yaitu oksigen dan nitrogen.   Kata kunci : bombardir, partikel bermuatan, plat tembaga, medan listrik dc, polaritas positif, polaritas negatif ABSTRACT At each test using high-voltage equipment, the equipment will produce a high electric field. The result of this electric field makes electrons and ions move and will produce ionisation process by colliding with free molecules that exist around the field. During the absence of electric field electrons and ions will continue to move up to the surface of the cathode and cause the phenomenon of bombarded charged particles. This research was conducted to determine the effect of bombarded charged particles on copper cathode against the air dielectric. The air dielectric pressure was variated from 558 mBar to achieve normal pressure. It is noted that the pressure changes affect the free distance of charged particles prior to the impact, while the value of voltage with the distance of the gap affects how quickly the kinetic energy of the charged particles when the bombard occurs. The bombard of particles occurs when the voltage value is sufficient to cause the electron to move at speed between 12,08eV – 15,52 eV or highher which is the condition on air where the mostcommon gas particles are N2 and O2. Keywords : bombardier, charged particle, copper plate, dc electric field, positive polarity, negative polarity
PENGARUH BENTUK KONTUR PERMUKAAN ISOLATOR POLIETILEN TERHADAP ARUS BOCOR DAN TEGANGAN FLASHOVER Dini Rizkita Sari; Mochammad Dhofir
Jurnal Mahasiswa TEUB Vol 6, No 3 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Isolator merupakan peralatan listrik yang berfungsi untuk mengisolasi penghantar bertegangan. Sebuah isolator dirancang agar dapat berfungsi dengan baik, memiliki tingkat arus bocor yang rendah dan tegangan flashover yang tinggi. Bahan isolasi yang sering digunakan yaitu keramik dan kaca. Namun saat ini telah dikembangkan bahan isolasi berjenis polimer yang memiliki kekuatan mekanik cukup tinggi dan tidak menyerap air. Penelitian dilakukan untuk mengetahui pengaruh bentuk kontur permukaan isolator polietilen terhadap distribusi medan listrik, tingkat arus bocor dan tegangan flashover. Simulasi distribusi medan listrik dilakukan menggunakan fasilitas FEMM 4.2. Bentuk kontur isolator terdiri dari variasi panjang sirip dan variasi posisi sirip, dengan jarak rambat yang sama. Isolator variasi panjang sirip memiliki posisi sirip di bagian tengah, terdiri dari isolator Tipe A, Tipe B dan Tipe C. Dari ketiga tipe tersebut, diperoleh hasil bahwa Tipe C memiliki kuat medan maksimum terendah sebesar 4,191 kV/cm, tingkat arus bocor terendah dan tegangan flashover tertinggi sebesar 73,29 kV. Kemudian isolator Tipe C divariasikan posisi siripnya yaitu, Tipe C1 dengan posisi sirip di atas, Tipe C2 dengan posisi sirip di tengah dan Tipe C3 dengan posisi sirip di bawah. Dari pengujian dan simulasi, diperoleh hasil bahwa Tipe C1 memiliki kuat medan maksimum terendah sebesar 2,827 kV/cm, tingkat arus bocor terendah dan tegangan flashover tertinggi sebesar 97,05 kV. ABSTRACT Isolator is an electrical equipment that works to isolate the conductors voltage. An insulator is designed to work properly, has a low leakage current and high flashover voltage. Insulation materials that are often used are ceramics and glass. But now has been developed polymer insulation material that has high mechanical strength and does not absorb water. The objective of this research is to know the influence of the surface contour form of the polyethylene insulator on the electric field distribution, the leakage current level and the flashover voltage. Simulation of electric field distribution is done using FEMM 4.2 facility. The contour form of the insulator consists of variations of the length of the fin and the variation of the fin position, with the same creepage distance. Isolator variation of the fin length has a fin position in the middle, consisting of Type A, Type B and Type C isolators. From the three types, it is obtained that Type C has the lowest maximum field strength of 4,191 kV/cm, the lowest leakage current and highest flashover voltage of 73.29 kV. Then Type C isolator varied the position of the fin is, Type C1 with the fin position on top, Type C2 with the fin position in the middle and Type C3 with the fin position below. From the test and the simulation, it was found that Type C1 has the lowest maximum field strength of 2,827 kV/cm, the lowest leakage current and the highest flashover voltage of 97,05 kV.
PERILAKU GELEMBUNG UDARA DALAM MINYAK TRANSFORMATOR DENGAN PENGARUH MEDAN LISTRIK DC NON HOMOGEN Lita Farahdiba; Mochammad Dhofir
Jurnal Mahasiswa TEUB Vol 8, No 3 (2020)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Transformator adalah bagian yang penting dalam sistem tenaga listrik. Hasil penelitian ini akan melihat pengaruh yang terjadi pada gelembung udara dalam minyak transformator jika diberi medan listrik DC Non Homogen serta akan menguji sifat listrik dari transformator minyak Shell Diala B berupa kekuatan dielektrik dari pengujian tegangan tembus, permitivitas dan resistivitas serta menguji perilaku gelembung udara dalam minyak transformator dengan pengaruh medan listrik DC Non Homogen. Untuk mendapatkan medan listrik non homogen maka digunakan dua elektroda yang berbeda bentuk yaitu berupa kawat-plat. Pada pengujian pengaruh medan listrik DC Non Homogen pada gelembung udara dalam minyak transformator akan di dapatkan hasil berupa waktu tempuh, kecepatan tempuh, percepatan gelembung udara, dan gaya-gaya yang mempengaruhi gelembung udara dalam minyak transformator. Objek uji yang digunakan berupa minyak transformator Shell Diala B dan gelembung udara. Pengujian dilakukan di Laboratorium Tegangan Tinggi Teknik Elektro Universitas Brawijaya. Pengujian menggunakan rangkaian pembangkitan tegangan tinggo AC dan DC  untuk mendapatkan nilai tegangan tembus, arus konduksi, dan arus bocor dari minyak transformator serta perhitungan gaya-gaya yang mempengaruhi gelembung udara dalam minyak transformator dengan pengaruh medan listrik DC Non Homogen dengan besar tegangan masukan yaitu 60 kV hingga 80 kV. Perhitungan gaya-gaya yang mempengaruhi gelembung udara dalam minyak transformator dengan pengaruh medan listrik DC Non Homogen menggunakan aplikasi FEMM 4.2 untuk mendapatkan data yang diperlukan. Kata kunci: Minyak transformator Shell Diala B, kekuatan dielektrik, perubahan bentuk, medan listrik DC Non Homogen   ABSTRACT Transformer is an important part in the electric power system. The results of this study will look at the effect that occurs in air bubbles in transformer oil if given a non-homogeneous DC electric field and will test the electrical properties of the Shell Diala B oil transformer in the form of dielectric strength from testing the breakdown voltage, permittivity and resistivity as well as testing the behavior of air bubbles in oil transformer with the influence of Non Homogeneous DC electric fields. To get a non-homogeneous electric field two electrodes of different shapes are used, which are wire plates. In testing the influence of non-homogeneous DC electric fields on air bubbles in transformer oil, the results will be in the form of travel time, travel speed, acceleration of air bubbles, and the forces that affect air bubbles in transformer oil. The test object used in the form of transformer oil Shell Diala B and air bubbles. The test was conducted at the Laboratory of Electrical Engineering's High Voltage UB. The test uses an AC and DC high voltage generation circuit to obtain the breakdown voltage, conduction current, and leakage current from the transformer oil and the calculation of the forces that affect air bubbles in the transformer oil with the influence of Non Homogeneous DC electric fields with large input voltage of 60 kV up to 80 kV. Calculation of forces that affect air bubbles in transformer oil with the influence of a Non Homogeneous DC electric field using the FEMM 4.2 application to obtain the required data. Keywords: Shell Diala B transformer oil, deformation, non-homogeneous DC electric field
PENGARUH BOMBARDIR PARTIKEL BERMUATAN PADA PERMUKAAN PLAT ALUMINIUM DENGAN DIELEKTRIK GAS NITROGEN MENGGUNAKAN HVDC POLARITAS POSITIF Bryan Malvin; Mochammad Dhofir; Unggul Wibawa
Jurnal Mahasiswa TEUB Vol 7, No 6 (2019)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Dalam setiap pengujian instrument tegangan tinggi, instrumen akan menghasilkan medan listrik tinggi. Medan tinggi mengakibatkan bergeraknya elektron dan ion yang menyebabkan ionisasi pada ruang medan. Pergerakan ion dipengaruhi oleh medan listrik tinggi akan menyebabkan tumbukan antara ion dengan permukaan katoda  dan menyebabkan fenomena bombardir partikel. Penelitian dilakukan untuk mengetahui pengaruh bombardir partikel ion positif pada katoda berbentuk aluminium terhadap tekanan dielektrik gas nitrogen. Tekanan dielektrik divariasi mulai dari 558 mBar hingga tekanan normal. Ditemukan bahwa nilai tegangan pada suatu tekanan mempengaruhi terjadinya ionisasi. Sedangkan perubahan tekanan mempengaruhi jarak bebas partikel yang mempengaruhi energi kinetik ion ketika bombardir terjadi. Bombardir partikel hanya terjadi ketika nilai tegangan cukup untuk menyebabkan elektron bergerak dengan energi kinetik diatas 15,53 eV yang merupakan syarat ionisasi gas N2. Pada tekanan 558 mBar pada tegangan 20 kV dengan arus konduksi 4,9 µA, bombardir partikel ion terjadi dengan kecepatan ion tertinggi yaitu 6.205 m/s dengan energi kinetik ion 5,96 eV. Hal ini menyebabkan kerusakan struktur mikro plat dengan pola kerusakan terpusat dan lubang akibat bombardir terbesar ditemukan sebesar 2,21 µm.   Kata kunci: Medan Listrik, Bombardir Partikel, Energi Kinetik Partikel ABSTRACT In every High Voltage Instrument testing, the instrument will generate a high electric field. The field caused electron and ion movement inside the space of the field that could lead to ionization. The ion movement affected by the high electrical field will result in the collision between ions and cathode’s surface that leads to the particle bombardment phenomenon. The studies conducted for knowing the effect of particle bombardment on aluminum plate’s surface with nitrogen dielectric pressure. The dielectric pressure was varied from 558 mBar relative to the room pressure  up to normal pressure. It was found that voltage at a pressure affects the ionization occurences. While the pressure changes affecting the mean free path of a particle which will affect the kinetic energy of ion when bombardment occured. Particle bombardment  only occurred when the voltage is enough to make electron move with kinetic energy above 15,53 eV, which the requirements for N2 ionization to occur. At pressure of 558 mBar with voltage of 20 kV and conduction current is 4,9 µA, the ion particle bombardment occurred at the highest speed of 6.205 m/s with 5,96 eV kinetic energy. This leads to the damaging of the plate’s microstructure with a centered pattern and the biggest hole caused by the bombardment found at 2,21 µm. Keyword: Electric Field, Particle Bombardment, Particle Kinetic Energy
ANALISIS DISTRIBUSI THERMAL PADA STRIP BIMETAL DENGAN FERROFLUID PADA RELAY BEBAN LEBIH MENGGUNAKAN FEMM 4.2 Bimo Ardiansyah; Mochammad Dhofir; Rini Nur Hasanah
Jurnal Mahasiswa TEUB Vol 7, No 1 (2019)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Jurnal ini membahas tentang sebuah model thermal overload relay yang menggunakan bahan tambahan pada konstruksi strip bimetalnya, yaitu menggunakan cairan magnet atau yang biasa disebut ferrofluid. Penggunaan ferrofluid ini bertujuan untuk meningkatkan respon thermal strip bimetal agar lebih akurat dan lebih cepat saat terjadi distribusi thermal. Percobaan distribusi thermal pada strip bimetal dilakukan pada waktu pemanasan tertentu, yaitu dalam waktu 300 detik, 360 detik, 420 detik, 480 detik, 540 detik, dan 600 detik melalui FEMM 4.2 dengan perpindahan thermal secara konveksi. Metode yang digunakan yaitu membuat perbandingan antara strip bimetal yang menggunakan ferrofluid sebagai penghantar thermal dan strip bimetal tanpa ferrofluid atau udara sebagai penghantar thermal dari sumber panas ke strip bimetal. Diketahui bahwa ferrofluid memiliki konduktivitas thermal sebesar 0,6501 W/(M°K) sedangkan konduktivitas thermal udara sebesar 0.026 W/(M°K). Dengan demikian, pada percobaan ini diperoleh hasil bahwa strip bimetal yang menggunakan ferrofluid sebagai penghantar thermal memiliki respon thermal yang lebih baik daripada strip bimetal yang menggunakan udara sebagai pemghantar thermalnya. Kata kunci: Thermal Overload Relay, Strip Bimetal, Ferrofluid, FEMM 4.2.   ABSTRACT This journal discusses a thermal overload relay model that uses additives in the construction of bimetallic strips, namely using magnetic fluids or commonly called ferrofluid. The use of ferrofluid aims to improve thermal response of bimetallic strip to be more accurate and faster when thermal distribution occurs. Thermal distribution experiments on bimetallic strip were carried out at certain heating times, namely within 300 seconds, 360 seconds, 420 seconds, 480 seconds, 540 seconds, and 600 seconds through FEMM 4.2 with convection thermal transfer. The method used is to make a comparison between the bimetallic strip using ferrofluid as a thermal conductor and the bimetallic strip without ferrofluid or air as a thermal conductor from the heat source to the bimetal strip. It is known that ferrofluid has a thermal conductivity of 0.6501 W / (M ° K) while thermal conductivity of air is 0.026 W / (M ° K). Thus, in this experiment the results showed that the bimetallic strip using ferrofluid as thermal conductor had a better thermal response than the bimetallic strip which used air as its thermal conductor. Keywords: Thermal Overload Relay, Strip Bimetal, Ferrofluid, FEMM 4.2.
KOORDINASI PROTEKSI ARESTER PCB DAN DIODA ZENER DENGAN ELEMEN DEKOPLING PADA PERALATAN LISTRIK Resi Ratnasari; Mochammad Dhofir; n/a Soemarwanto
Jurnal Mahasiswa TEUB Vol 2, No 6 (2014)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (850.066 KB)

Abstract

Pada arester PCB terdapat kesulitan dalam merekayasa jarak elektroda sela udara di bawah 1 mm dengan tingkat proteksi 1,5 kV. Apabila digunakan untuk mendapatkan tingkat proteksi 0,8 kV dibutuhkan suatu kombinasi proteksi antara arester PCB dan dioda zener secara kaskade. Kaskade arester ini memerlukan suatu elemen dekopling agar koordinasi proteksinya dapat berjalan dengan baik. Penelitian ini menggunakan beberapa metode yaitu perancangan, pengujian dan analisis kaskade arester. Perancangan kaskade arester meliputi perancangan arester PCB, pemilihan dioda zener dan perancangan elemen dekopling. Pengujian dilakukan dengan menaikkan tegangan dari 2 kV hinga 10 kV impuls puncak. Berdasarkan hasil pengujian didapatkan bahwa elemen dekopling yang digunakan adalah induktor 0,36 mH dengan inti ferit. Pada kaskade arester dengan elemen dekopling tersebut, tegangan impuls 10 kV mampu dipotong hingga 317 V dengan waktu pemotongan 80 ns.Kunci kunci – kaskade arester, arester PCB, dioda zener, elemen dekopling, induktor
PENGARUH JUMLAH SIRIP PERMUKAAN ISOLATOR POLIETILEN TERHADAP TINGKAT ARUS BOCOR DAN TEGANGAN FLASHOVER PADA KONDISI KERING DAN BASAH Muhammad Ghufron Auliya Rahman; Mochammad Dhofir; Hadi Suyono
Jurnal Mahasiswa TEUB Vol 8, No 5 (2020)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Isolator merupakan alat listrik yang digunakan untuk mengisolasi, yaitu memisahkan secara elektris dua buah penghantar atau lebih yang berdekatan, sehingga tidak terjadi kebocoran arus atau dalam hal gradien tinggi berupa lompatan api (flashover). Pada penelitian ini akan diuraikan pengaruh dari jumlah sirip permukaan isolator terhadap distribusi medan listrik, tingkat arus bocor, dan tegangan flashover dalam kondisi kering dan basah. Material penyusun isolator yang digunakan adalah polietilen, dengan tiga variasi jumlah sirip yaitu 1 sirip, 2 sirip, dan 3 sirip. Jarak antar elektroda dan jarak rambat dari isolator dibuat sama, dengan pembuatan dimensi yang memperhatikan standar IEC. Metode penelitian yang digunakan adalah dengan mengambil data arus bocor dan tegangan flashover secara langsung di Laboratorium Teknik Tegangan Tinggi Universitas Brawijaya, serta dilakukan simulasi distribusi medan listrik pada masing-masing variasi isolator menggunakan software FEMM 4.2. Pengujian dilakukan dengan menggunakan tegangan tinggi AC, dengan variasi tegangan uji 2, 4, 5, 6, 8, 10, 12, 14, 15, 20, dan 25 kV. Pada pengujian kondisi basah, digunakan tiga variasi debit pembasahan, yaitu 10, 30, dan 60 mL/s yang mengacu pada tren curah hujan di Indonesia. Pada penelitian ini didapatkan bahwa semakin banyak jumlah sirip isolator dengan jarak rambat dan jarak vertikal yang sama akan membuat distribusi medan maksimum dan arus bocornya semakin kecil, sedangkan tingkat homogenitas dan tegangan flashover akan semakin besar. Debit pembasahan juga berpengaruh terhadap arus bocor, dimana peningkatan debit pembasahan berbanding lurus dengan tingkat arus bocor dan berbanding terbalik dengan ketahanan suatu isolator menahan tegangan flashover, hasil ini mampu didapatkan dengan baik karena objek uji pada penelitian ini memiliki sifat pencucian alami yang baik dan tidak mengalami hubung singkat lokal. Kata kunci: Isolator polietilen, jumlah sirip isolator, arus bocor, tegangan flashover ABSTRACT An insulator is an electrical device used to isolate, which is to electrically separate two or more adjacent conductors, so that there is no leakage current or in the case of high gradients in the form of a flashover. This research will describe the effect of the number of surface fins of the insulator on the distribution of the electric field, the level of leakage current, and the flashover voltage in dry and wet conditions. The materials used  for the insulator is polyethylene, with three variations in the number of fins, namely 1 fin, 2 fins, and 3 fins. The distance between the electrodes and the propagation distance of the insulator is made the same, with IEC Standards as dimension manufacturing reference. The research method used is to take the leakage current and flashover voltage data directly at the High Voltage Engineering Laboratory of Brawijaya University, and simulate the distribution of the electric field on each variation of the insulator using the FEMM 4.2 software. The test was carried out using a high AC voltage, with variations in the test voltage of 2, 4, 5, 6, 8, 10, 12, 14, 15, 20, and 25 kV. In wet condition test, three variations of wetting discharge is used, namely 10, 30, and 60 mL/s which refers to the trend of rainfall in Indonesia. In this study, it was found that greater number of insulator fins with the same propagation and vertical distance, resulted in smaller maximum field distribution and the leakage current, while greater value was found in the homogeneity level and the flashover voltage. Wet discharge also affects the leakage current, where the increase in wetting discharge is directly proportional to the level of leakage current and inversely proportional to the resistance of an insulator that withstand flashover voltage, this result can be obtained properly because the test object in this study has good natural washing properties and does not experience local short circuit. Keywords : Polyethylen insulator, number of insulator fins, leakage current, flashover voltage
Co-Authors Affan Rafli Andriansyah Agung Firmansyah Sunardi Ahmad Fadly Irawan Ahmad Nahla Rialdi Ahmad Reza Yahya Akhmad Hasim Albin Adyaksa Sabil Aldian Eka Fitranto Aldo Julian Hastono Alif Rahmatullah Umar Amadea, Cinta Hanifa Andreas Parningotan S. Andrian Dwiputro Arbi Ramadhan Arifin Surya Winarto Ashydiq Chenny Saputra Atika Rahma Hadiana Avif Septian Imandyan Ayu Puspitasari Bagus Ibnu Pratama Bimo Ardiansyah Bobby Hertanto Boby Satriya Nugraha Bryan Malvin Candra Mebby Oka Charis Majid Teguh P. Danang Aji Nugroho Dandhi Tri Laksono Daniel Kristo Mula Lambok Pangaribuan Desinta Ayu Woro H. Devanda Antonius Y. R. Dimas Hariyo Kuncoro Dini Rizkita Sari Epprylia Prima Maimunawati Erya Septy Dwi Wardhani Firmansyah Putra Satria Galuh Indra Permadi Habriansyah Basta Nugraha Hakim, Luqman Harry Soekotjo Dachlan Hery Purnomo I Wayan Ari Mahendra Ibnu Sabilli Idham Budi Satria Ignatius Agung Pratama Ihza Aulia Rahman Iksan , Santoso Ilham Ismail Mochsen Imam Sabilil Haque Jovie Trias Agung Nugroho Kresna Sukma Dewangga Lita Farahdiba M. Iqbal Bayhaqi Fauzi Mahfudz Shidiq Maulana Akhtar Khaqqi Maulana Rahmat Ramadhani Maulani Candra Mochammad Muchlis Triwahyudi Mohamad Adif Muhammad Ghufron Auliya Rahman Mukti Ayu Nur Vitasari n/a Dammegi n/a Firohman n/a Soemarwanto n/a Wijono Nadhea Primasetya Nudira, Rizar Nur Subhan Nurizza Salsa Alafia Pegy Lestari Priya Surya Harijanto Putra Adi Dharma Utama Rahmadwati, n/a Refli Maulana Resi Ratnasari Rezki Awalia Novianti Harun Ridho Darmawan Rini Nur Hasanah Rize Taufiq Ramadhan Rizki Chandra Maulana Singgih Andi Rubiyanto Sipa Peberina Ginting Suyono, Hadi Taufik Adi Nugroho Teguh Utomo Thoriq Kamal Septianhasri Timbul Mulia Tri Nurwati Unggul Wibawa Wicaksono, Angga Dwiki Wiken Cahyo Pambudi Yoga Prasetya Yukovany Zhulkarnaen Yusri Bakhtiar Zamrud Kurnia Prasetyo