Pendampingan Evaluasi Nilai Tingkat Panduan Diagnostik Indonesia (TPDI) pada Pemeriksaan Radiografi Umum di Rumah Sakit Mardi Rahayu Kudus Giner Maslebu; Jodelin Muninggar; Faldy Tita; Juana Mauren Abigail Koleba; Yemima S Yulandewi; Harya Abdi Prakoso
Magistrorum et Scholarium: Jurnal Pengabdian Masyarakat Vol. 6 No. 1 (2025)
Publisher : Universitas Kristen Satya Wacana Salatiga

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24246/jms.v6i12026p42-51

Abstract

Unit Radiologi di Rumah Sakit berfungsi melayani pemeriksaan ahli melalui teknologi pencitraan medis berbasis pengetahuan tentang interaksi radiasi dengan materi termasuk sinar-X pada pesawat radiografi umum. Dalam rangka proteksi radiasi dan ketepatan dosis radiasi, maka pemerintah melalui BAPETEN menetapkan Tingkat Panduan Diagnostik Indonesia (TPDI) pada berbagai posisi anatomis berbasis perhitungan nilai INAK dan ESAK. Pengabdian Masyarakat yang dilakukan pada Rakit Mardi Rahayu Kudus secara spesifik menyasar wilayah ekstremitas bawah dengan temuan bahwa untuk daerah pemeriksaan Femur dan Pedis dari para pasien, nilai TPDI masih dibawah batas maksimum yang diizinkan oleh regulasi pemerintah. Dengan demikian, pasien mendapatkan dosis radiasi yang aman dan para pekerja di instalasi radiologi dapat mengoperasikan peralatan radiografi umum untuk tujuan pemeriksaan diagnostik yang memenuhi prinsip ALARA
Analisis Resolusi Spasial Citra Ultrasonografi (USG) pada Arah Tangensial Radias Citra menggunakan Phantom Berbasis Silicon Rubber: Victory Immanuel Ratar, Surya Suryasatriya Trihandaru, Giner Maslebu Victory Immanuel Ratar Victory Immanuel Ratar; Surya Suryasatriya Trihandaru Surya Suryasatriya Trihandaru; Giner Maslebu Giner Maslebu
Jurnal Fisika dan Aplikasinya Vol 16 No 1 (2020): January 2020 Edition
Publisher : Lembaga Penelitian dan Pengabdian Kepada Masyarakat, LPPM-ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j24604682.v16i1.4287

Abstract

Ultrasound is widely used in diagnostic imaging, therefore quality control(QC) of ultrasound images is important. One of the QC parameter is spatial resolution that can be analyzed by calculating the distance between two nearby object in the tangential direction of radiation. The image that is produced by the Curved Array transducer will produce a circular shaped image and the coordinates of the object isn’t in the cartesian coordinate system because it adapts to the surface of the transducer. The image must be transformed with a circle equation approach to calculate the distance between two nearby object. This study was using a Mindray 3D ultrasound model: DP-10 with Transducer model: 35C50EB, and phantom instruments made from a mixture of 99 ml silicon rubber and 1 ml catalyst. The acquisition data used a fixed frequency of 4.5 MHz with a gain variation of 168 dB, 182 dB, 202 dB and a depth variation of 3.3 cm, 4.9 cm, 5.7 cm. The result found that the measurement of objects in A area had an error of 0.8963%(0.087 mm),B area was 1.2979%(0.0779 mm), and C area was 2.6296%( 0.1183 mm). The values obtained still meet the standards set by American Association of Physicist in Medicine(AAPM).
Studi Difusi Ca2+ Pada Sinapsis Menggunakan Metode Monte Carlo Cell: Ester Ratna Sari, Giner Maslebu, Adita Sutresno Ester Ratna Sari Ester Ratna Sari; Giner Maslebu Giner Maslebu; Adita Sutresno Adita Sutresno
Jurnal Fisika dan Aplikasinya Vol 16 No 1 (2020): January 2020 Edition
Publisher : Lembaga Penelitian dan Pengabdian Kepada Masyarakat, LPPM-ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j24604682.v16i1.5076

Abstract

Diffusion process became one of the important mechanisms in the human body system, such as in the nervous system which is the Ca2+diffusion in the synapses. This research aims to study the Ca2+diffusion process if Gd inhibits Ca2+channel in pre-synapses. This study did not use Gd, but it was modeled with various numbers of Ca2+ channels. The less number of Ca2+opened channels described the more Gd which inhibited Ca2+ channels. The Monte Carlo Cell Method (MCell) was used in this study. The synapses model was made using Blender 2.76b; consisted of two compartments illustrated with two circles. The molecule in the outside pre-synapses compartment interacted with the molecular surface of the pre-synapses compartment and resulted in a molecule in pre-synapses. The result of the simulation process for the molecules reached half of the variations in the number of total area channels. The time needed being 0.65s, 0.34s, 0.24s, and 0.18s, from the smallest to the biggest respectively. The times needed for density variations from big to small were 0.337s, 0.362s, and 0.364s respectively. The number of the diffused molecules in the backward rate variation within the same time was 3928, 3626, 2037, and 529 molecules respectively.
Efektivitas Paparan Medan Magnet Lemah Terhadap Tingkat Kesempurnaan Pembakaran Bahan Bakar Minyak Beroktan Rendah: Shinta Monika Utami, Giner Maslebu, dan Nur Aji Wibowo Shinta Monika Utami Shinta Monika Utami; Giner Maslebu Giner Maslebu; Nur Aji Wibowo Nur Aji Wibowo
Jurnal Fisika dan Aplikasinya Vol 15 No 2 (2019): June 2019 Edition
Publisher : Lembaga Penelitian dan Pengabdian Kepada Masyarakat, LPPM-ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j24604682.v15i2.3578

Abstract

Increasing levels of octane fuel in order to efficient its increasingly scarce use has been done. However, consumers still maintain the use of low-octane fuel because of its affordable price. The treatment in the form of magnetic field exposure on fuel is a means that is believed able to improve the completeness of combustion. In this study, tests were conducted on low-octane fuel with exposure to weak magnetic fields aimed at streamlining the scarcity of low-octane fuel usage. Exposure to weak magnetic fields in the storage tank before going into the combustion process will stretch the hydrocarbon bonds so that the hydrocarbon molecules are easier to oxidise. Fuel exposed to a weak magnetic field is applied to a two-stroke engine with varying engine workloads. The level of combustion completeness is measured from reduction of fuel consumption and the percentage of O2 emissions. The results of this study indicate that exposure to weak magnetic fields on low-octane fuel significantly improves the completeness of combustion processes.
DOSIMETRIC EVALUATION AND MATHEMATICAL MODELING OF AIR KERMA IN LOWER EXTREMITY RADIOGRAPHY Maslebu, Giner; Muninggar, Jodelin; Tita, Faldy; Yulandewi, Yemima Sandra; Prakoso, Harya Abdi; Koleba, Mauren Abigail
Jurnal Ilmiah Ilmu Terapan Universitas Jambi Vol. 10 No. 3 (2026): Volume 10, Nomor 3, June 2026
Publisher : LPPM Universitas Jambi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22437/jiituj.v10i3.56453

Abstract

Achieving an optimal balance between diagnostic image quality and radiation dosimetry is foundational to effective diagnostic imaging and the ALARA principle. The aim of this study is to analyze Incident Air Kerma (INAK) and Entrance Surface Air Kerma (ESAK) values from general radiograph examination to evaluate diagnostic efficacy and radiation safety. Baseline data were collected from quality control compliance testing of a Radnext32 Hitachi Computed Radiography system. Subsequently, data analysis was conducted on a lower extremity radiographic survey, encompassing over 30 patients per region using a constant focus-to-film distance of 100 cm.  By using graph plotting tool in Microsoft excel, it revealed a robust correlation between tube voltage (kV) and INAK (R2>0.99), modeled by the power function trendline y=5.10-6x2,1593. Femur examinations result in the highest ESAK values (0.20–0.60 mGy, outliers to 0.92 mGy), while genu, cruris, and ankle doses clustered tightly between 0.04–0.37 mGy. All values complied with the Indonesia Dose Reference Level (I-DRL) and IAEA guidelines. Radiation dose correlated linearly with body weight, though data dispersion suggests confounding anthropometric variables (sex, age, height) influence optimization. Discussion: This study establishes critical baseline dosimetry for lower extremity radiography. Its novelty lies in establishing a precise mathematical power function to predict INAK and ESAK changes specifically for lower extremities based on real-world clinical data. These findings advance radiation research by highlighting that standard weight-based dosing is insufficient; future optimization protocols must multi-variably integrate diverse patient anthropometrics and mandatory source-to-surface distance measurement to refine clinical standard operating procedures.