Asesmen Geoteknik Keretakan Cold Water Pipe (CWP) pada Pembangkit Listrik Tenaga Uap dan Rekomendasi Perbaikan Khoeri, Heri; Badaruddin, B; Isvara, Wisnu
Prosiding Seminar Nasional Teknik Sipil UMS 2024: Prosiding Seminar Nasional Teknik Sipil UMS
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pipa air dingin (Cold Water Pipe, CWP) sebuah PLTU mengalami kebocoran setelah 7 tahun beroperasi karena retaknya CWP yang mengakibatkan PLTU shutdown. Perbaikan sudah dilakukan termasuk dengan aplikasi pile jet grouting tepat di bawah CWP namun kebocoran masih terjadi. CWP tersebut diletakkan di atas tanah lunak setebal 35m (Nspt 2 s/d 4) dengan tambahan timbunan 3m sebelum pemasangan CWP tanpa soil improvement. Asesmen dilakukan untuk mengevaluasi penyebab terjadinya kebocoran pipa, mengevaluasi efektivitas pile jet grouting, dan memberikan rekomendasi perbaikan yang tidak menimbulkan masalah baru di kemudian hari. Hasil analisis menunjukkan penurunan tanah akibat konsolidasi setelah 7 tahun beroperasi telah mencapai 60% yaitu 46cm. Nilai ini mendekati hasil pengukuran lapangan yang nilainya antara 30 cm s/d 50 cm. Masih ada potensi penurunan hingga derajat konsolidasi 90%, yang diestimasi 60cm di tahun ke-15 setelah operasi, artinya dalam 8 tahun berikutnya potensi penurunan masih 20cm. Kebocoran teridentifikasi akibat perbedaan penurunan antara CWP yang menumpu pada pile cap dengan yang langsung di tanah, mencapai 4 cm sesaat setelah pipa ditanam, meningkat menjadi 5.5cm pada tahun ke-7, dan 5,7cm pada tahun ke-15. Pipa sepanjang 12m dengan penurunan 5.5cm akan berotasi 0.53o pada tumpuannya, nilai ini melebihi batas ijinnya yang dibatasi 0.5o. Aplikasi jet grouting setempat justru berpotensi menambah penurunan. Mengingat masih ada potensi penurunan namun tidak sebesar di 7 tahun pertama, maka merekomendasikan pemasangan camp plate sebagai alat monitoring dan adjustable support untuk menaikkan pipa jika camp plate mengindikasikan penurunan mendekati batas ijinnya.
Pemodelan berbasis Uji Non-Destruktif dan Semi-Destruktif yang Divalidasi Uji Vibrasi pada Asesmen Reliabilitas Pondasi Jibcrane Rizqullah, Naufal Rafif; Khoeri, Heri; Buwono, Haryo Koco; Badaruddin, B
Prosiding Seminar Nasional Teknik Sipil UMS 2024: Prosiding Seminar Nasional Teknik Sipil UMS
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Untuk menjamin keamanan dalam pengoperasian Jibcrane dilakukan pemeriksaan berkala termasuk pada sistem pondasinya. Penelitian ini dilakukan untuk mendapat gambaran reliabilitas sistem pondasi setelah jibcrane beroperasi 10 tahun. Sistem pondasi jibcrane yang diteliti adalah tiang pancang pipa baja yang disatukan pile cap dan diperkuat bracing antar pipa. Pemeriksaan dilakukan dengan uji non-destruktif dan semi-destruktif untuk mendapatkan gambaran aktual dimensi dan mutu elemen struktur. Seluruh data uji dikompilasi sehingga menjadi data yang dapat dijadikan input dalam pemodelan struktur. Penentuan jumlah dan jenis uji mempengaruhi validitas model, dimana semakin banyak dan lengkap, maka model akan lebih merepresentasikan kondisi aktualnya. Validitas model dilakukan dengan uji vibrasi. Hasil analisis menghasilkan frekuensi alami 1,48 Hz, sementara hasil uji vibrasi sebesar 1,5 Hz, dengan nilai frekuensi yang berdekatan menunjukkan data input cukup valid yang menghasilkan respon dinamik mendekati aktualnya. Hasil analisis menunjukkan pondasi jibcrane masih reliabel dengan faktor keamanan 3,1. Kendatipun demikian, untuk memperlambat laju korosi pada baja perlu dilakukan perlindungan dengan melakukan pengecatan berkala permukaan pondasi pipa baja dan bracing pengakunya, melakukan injeksi pada beton yang retak, dan memproteksi beton dari pengaruh reaksi alkali-silika dengan pengecatan anti-korosi berbasis bituminous.
FORMULATION OF CONCRETE COMPRESSIVE STRENGTH BASED ON BUILDING AGE, DENSITY, AND NON-DESTRUCTIVE TESTING WITH ULTRASONIC PULSE VELOCITY TESTS Khoeri, Heri; Wisnu Isvara; Roberto Pradana; Dini Sofiana
Clean Energy and Smart Technology Vol. 2 No. 2 (2024): April
Publisher : Nacreva Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58641/cest.v2i2.85

Abstract

In the assessment of existing reinforced concrete buildings, the compressive strength of concrete, , is a key parameter for performance assessment. The most accurate way to identify it is by conducting compressive strength tests on core concrete samples from structural elements obtained through drilling. The more samples taken, the more accurate the determination of for structural modeling will be. However, sampling in buildings certainly disrupts activities within the building, compounded by drilling marks that leave traces even after repairs. Therefore, sample collection must be selective, yet the results must still provide confidence as input for structural analysis. A method for estimating using the ultrasonic pulse velocity test, UPVT, categorized as a Nondestructive Test, NDT, has long been used and continues to be developed. Various building regulations state that NDT for estimating should be paired with the results of compressive strength tests on core concrete samples to obtain correlation between them. The relationship equation between wave propagation velocity, , and varies between studies, indicating that besides , there are other influencing factors. In this study, samples were taken from 5 (five) buildings of different ages. In addition to , the effects of density, , and age, , were examined. The results of the study indicate that has no effect, while influences the relationship between V and according to the equation with .
Quick Assessment of Bridge Performance Based on Dynamic Parameters Acquired with Smartphone Application Khoeri, Heri; Nugroho, Panji; Pradana, Roberto
Clean Energy and Smart Technology Vol. 2 No. 2 (2024): April
Publisher : Nacreva Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58641/cest.v2i2.86

Abstract

The road management regulation aims to achieve reliable and excellent road services that prioritize the interests of the community by ensuring the functional and competitive performance of the roads, as well as community participation in road management in accordance with Republic of Indonesia Law No. 2 of 2022. As part of the community, when crossing the Tegineneng Bridge on the Tegineneng-Sp. Tanjung Karang road section in Lampung Province and feeling discomfort from the bridge vibrations, participating individuals conducted vibration measurements using 2 smartphones. The gyroscopes in the smartphones, packaged within a g-force application, were capable of recording real-time vibrations in a user-friendly manner, and the output data was compatible with existing modal analysis software. Subsequently, vibration data recordings using the SSI algorithm yielded dynamic parameters such as a natural frequency of 2.009Hz and a damping ratio of 7.927%. The frequency of 2.009Hz for a span of 60m is lower compared to bridges of the same span from the dynamic bridge test regression equation in Indonesia, which is 2.347Hz. Under these conditions, it is estimated that the Tegineneng Bridge experienced minor structural damage with a damage level of 14.1% and its capacity is lower by 28.2% than the empirical estimate. The damping ratio exceeding 5% is estimated to be due to excessive energy dissipation through cracks in the concrete or through defects in the connections between steel frame elements. It is recommended that relevant stakeholders conduct a detailed inspection of the bridge to ensure its safety and undertake necessary measures to guarantee the safety of its users.
Uji Beban Statik dan Dinamik untuk Asesmen Reliabilitas Jembatan Baja Komposit Bentang 20m, 25m dan 30m Khoeri, Heri
Pasak: Jurnal Teknik Sipil dan Bangunan Vol 1 No 2 (2024): Maret
Publisher : Fakultas Teknik dan Ilmu Komputer Universitas Sains Al-Quran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32699/pasak.v1i2.6957

Abstract

Jembatan adalah salah satu prasarana transportasi vital yang berdampak pada bidang sosial, ekonomi, pertahanan dan keamanan, sehingga aspek keselamatan dan kenyamanan penggunanya harus benar-benar terpenuhi sebagaimana dinyatakan dalam Permen PUPR 10 tahun 2022 tentang Keamanan Jembatan dan Terowongan. Penilaian reliabilitas jembatan dapat diperoleh dari parameter statik pada kondisi layannya dengan tidak terlampauinya batas lendutan dan batas tegangan saat operasional termasuk saat pembebanan maksimum terjadi, juga terpenuhinya kriteria penilaian parameter dinamik yang salah satunya dari frekuensi alami. Untuk mengetahui reliabilitas 3 (tiga) buah jembatan baja komposit pada akses jalan Mukut, Sumatera Selatan, maka dilakukanlah uji beban statik dan dinamik. Dari uji beban dinamik diketahui tingkat kerusakan jembatan 2, 3, dan 4 secara berurutan sebesar 2.1%, 22.4% dan 25%. Dari hasil uji beban baik statik maupun dinamik teridentifikasi kapasitas jembatan 2, 3 dan 5 secara berurutan 95% (61 ton), 54% (43 ton), dan 49% (46 ton) dari rencananya. Karena ketiga jembatan tersebut dalam satu akses jalan, maka total beban yang diijinkan berada diatas jembatan adalah 43 ton. Diperoleh nilai akurasi yang cukup tinggi dari uji beban dinamik untuk penilaian reliabilitas bangunan atas jembatan dimana perbedaannya dengan uji beban statik hanya 0.04%­ + 0.8%. Dengan perbedaan yang sangat kecil mengingat uji beban dinamik memerlukan waktu yang relatif lebih singkat, maka dapat dinyatakan bahwa uji beban dinamik cukup efektif dan efisien untuk menilai reliabilitas struktur bangunan atas jembatan, selama jembatan masih berperilaku linear elastis.
PEMODELAN BERBASIS UJI NON-DESTRUKTIF DAN SEMI-DESTRUKTIF YANG DIVALIDASI FREKUENSI ALAMI PADA ASESMEN RELIABILITAS PONDASI JIB CRANE Heri Khoeri; Naufal Rafif Rizqullah; Badaruddin Badaruddin; Haryo Koco Buwono
RENOVASI : Rekayasa Dan Inovasi Teknik Sipil Vol 8 No 2 (2023): Oktober
Publisher : Department of Civil Engineering, Faculty of Engineer, Universitas Sarjanawiyata Tamansiswa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30738/renovasi.v8i2.17132

Abstract

To ensure the safety of operating the Jib crane, regular inspections and evaluations need to be conducted, including on the foundation structure system. The allowable load specified by the manufacturer only applies when the crane is positioned relatively flat against its support; thus, if the crane is tilted due to settlement at the support during operation, the allowable load will drastically decrease and may cause an overturning. This study was conducted to assess the reliability of the current foundation system after 10 years operation. The foundation system of the Jib crane under investigation consists of steel pipe piles connected to a pile cap at the top and reinforced with bracing between the pipes. Inspections were carried out using non-destructive and semi-destructive testing to obtain actual dimensions and quality of the structural elements. All test data were compiled to serve as input for structural modeling. To ensure the validity of the model, verification was performed with vibration test results. The determination of the number of points and types of tests affects the validity of the model, where the more numerous and comprehensive the tests, the more accurately the model represents actual conditions. The analysis results of the model produced a natural frequency of 1.48 Hz, while the dynamic load test result was 1.5 Hz, with closely matching frequencies indicating sufficiently valid input data, resulting in dynamic structural responses close to reality. The analysis results of the model indicate that the Jib crane foundation is still reliable with a safety factor of 3.1. However, to slow down the corrosion rate of the steel, protective measures are necessary, including periodic painting of the surface of the steel pipe foundation and its supporting bracing, injection into cracked concrete, and protecting concrete from alkali-silica reaction by applying corrosion-resistant bituminous-based painting.
Evaluasi Kekakuan dan Stabilitas Hauling Road Berdasarkan Modulus Deformasi Tanah Hasil Repetitive Static Plate Load Test: EVALUATION OF HAULING ROAD STIFFNESS AND STABILITY BASED ON SOIL DEFORMATION MODULUS FROM REPETITIVE STATIC PLATE LOAD TEST Khoeri, Heri; Dini Sofiana; Panji Nugroho
Jurnal Teknik Sipil : Rancang Bangun Vol. 12 No. 01 (2026): April 2026
Publisher : Universitas Muhammadiyah Sorong

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33506/rb.v12i01.5359

Abstract

Kinerja struktural hauling road ditentukan oleh kekakuan dan stabilitas tanah dasar akibat beban berat berulang. Evaluasi lapangan umumnya dilakukan menggunakan repetitive static plate load test dengan modulus deformasi siklus pembebanan lanjutan sebagai dasar pemenuhan kriteria desain, meskipun pendekatan satu parameter belum sepenuhnya menggambarkan kondisi awal dan evolusi kekakuan tanah dasar. Penelitian ini mengevaluasi kinerja subgrade hauling road menggunakan repetitive static plate load test pada beberapa titik uji yang mewakili berbagai jalur operasional. Analisis difokuskan pada respons pembebanan siklus awal dan lanjutan serta rasio peningkatan kekakuan sebagai indikator stabilisasi tanah. Hasil menunjukkan bahwa sebagian besar titik uji memenuhi modulus minimum desain, namun didominasi oleh rasio peningkatan kekakuan yang tinggi, yang mengindikasikan sensitivitas subgrade terhadap pembebanan awal. Titik yang tidak memenuhi kriteria desain berkorelasi dengan kekakuan awal yang rendah dan dominasi deformasi plastis. Temuan ini menegaskan bahwa evaluasi kinerja subgrade hauling road akan lebih komprehensif apabila pemenuhan kriteria desain dikombinasikan dengan analisis perilaku tanah akibat pembebanan berulang untuk mendukung pengendalian mutu dan strategi perbaikan yang lebih efektif dan berkelanjutan.
PENGARUH BERLAWANAN KONFINEMEN CFRP DENGAN ADANYA CHAMFER DAN REDUKSI LUAS PENAMPANG PADA KOLOM BETON BERTULANG PERSEGI: COUNTERACTING EFFECTS OF CFRP CONFINEMENT AND CHAMFER-INDUCED AREA REDUCTION IN SQUARE REINFORCED CONCRETE COLUMNS Khoeri, Heri; Panji Nugroho
Jurnal Teknik Sipil : Rancang Bangun Vol. 12 No. 01 (2026): April 2026
Publisher : Universitas Muhammadiyah Sorong

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33506/rb.v12i01.5405

Abstract

Perkuatan kolom beton bertulang persegi menggunakan Carbon Fiber Reinforced Polymer (CFRP) merupakan metode yang efektif untuk meningkatkan kapasitas struktur eksisting. Pada kolom persegi, aplikasi CFRP full jacket memerlukan pembulatan sudut (chamfer) guna meningkatkan efektivitas konfinemen, namun pembesaran chamfer secara simultan menyebabkan pengurangan luas penampang beton efektif. Penelitian ini mengevaluasi keseimbangan pengaruh antara peningkatan kapasitas akibat konfinemen CFRP dan penurunan kapasitas akibat kehilangan luas penampang pada kolom beton bertulang persegi. Studi dilakukan pada kolom berukuran 400×400 mm dengan pembesian 8D16, sengkang D10-150, mutu beton f’c = 25 MPa, dan baja tulangan fy = 400 MPa, yang diperkuat CFRP dua lapis dengan orientasi serat hoop full jacket. Variasi radius chamfer dianalisis mulai dari r = 20 mm hingga batas maksimum yang ditentukan oleh selimut beton eksisting. Kapasitas kolom dievaluasi menggunakan diagram interaksi aksial–momen (Pn–Mn) dengan mempertimbangkan beton terkekang dan pengurangan luas penampang efektif secara eksplisit. Hasil menunjukkan bahwa peningkatan radius chamfer meningkatkan efektivitas konfinemen CFRP dan kapasitas kolom secara keseluruhan, sementara pengaruh negatif akibat reduksi penampang relatif lebih kecil, meskipun kecenderungan diminishing return terlihat pada radius yang lebih besar.
Uji Beban Statis Dan Dinamis Jembatan Baja Komposit Batang Toru-4 Heri Khoeri; Panji Nugroho
Jurnal Konstruksi dan Infrastruktur : Teknik Sipil dan Perencanaan Vol 13 No 3 (2025): Jurnal Konstruksi dan Infrastruktur Vol 13 No.3 Desember 2025 Special Edition: E
Publisher : Civil Engineering Department, Faculty of Engineering, Universitas Swadaya Gunung Jati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jki.v13i3.10749

Abstract

Bridges are vital infrastructure that require feasibility evaluation before being used to ensure user safety. Feasibility assessment can be done through dynamic and static tests. The dynamic parameters used are natural frequency and damping ratio, while static parameters include deflection and strain during loading. This study conducted forced vibration tests and static load tests on the Batang Toru-4 Bridge. The vibration test results showed a natural frequency of 3,248 Hz, lower than the minimum limit of 3,357 Hz according to Bina Marga empirical data, but still above the British Standard, and a damping ratio of 7.636%, indicating an indication of excessive energy dissipation which is generally due to defects in the structure. However, the static test showed a maximum deflection at 100% UDL of 11.9 mm, still far below the permissible limit of 50 mm. The residual deflection ratio was also only 0.044, still below the permissible limit of 0.2. Therefore, with these results, the bridge was declared functionally fit, but it was recommended to conduct further checks to ensure that excessive damping was not caused by structural damage. The calculated relative capacity is approached by a more conservative dynamic load test compared to a static load test, so that the dynamic load test is an alternative test with a relatively faster time, easier and more conservative results compared to the static load test.
Mitigasi Getaran Enclosed High Temperature Flaring System (EHTFS) Berbasis Operational Modal Analysis dan Interaksi Tanah–Struktur Heri Khoeri; Wisnu Isvara
Jurnal Konstruksi dan Infrastruktur : Teknik Sipil dan Perencanaan Vol 14 No 1 (2026): Jurnal Konstruksi dan Infrastruktur Vol 14 No.1 : April 2026
Publisher : Civil Engineering Department, Faculty of Engineering, Universitas Swadaya Gunung Jati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jki.v14i1.11711

Abstract

Enclosed High Temperature Flaring Systems (EHTFS) are employed to control gas emissions through high-temperature enclosed combustion; however, structural modifications such as flare stack heightening may alter dynamic characteristics and induce environmental vibration problems. This study evaluates vibration responses induced by EHTFS operation and investigates the mechanisms of vibration amplification and resonance affecting surrounding structures. Field measurements were carried out using three-axis accelerometers installed on the flare stack, supporting structures, soil, and nearby residential buildings during flaring events. Structural dynamic properties were identified using Operational Modal Analysis (OMA) based on the Stochastic Subspace Identification (SSI) method, combined with an assessment of soil–structure interaction. The results show dominant vibration frequencies of 6.1–6.2 Hz, where the natural frequencies of the flare stack and nearby houses are closely spaced. Peak acceleration at residential buildings reached 0.149 m/s², approximately twice that at the source (0.074–0.077 m/s²), indicating significant amplification. Soil investigation revealed shear-wave velocities of 168–257 m/s with relative dynamic amplification factors up to 1.0. Although soil–structure interaction influences wave propagation, the observed amplification is primarily attributed to low-frequency resonance between operational excitation and structural natural frequencies. Increasing flare stack stiffness effectively shifts the natural frequency and reduces resonance potential. The proposed integrated OMA–SSI framework provides a reliable basis for vibration mitigation in industrial flaring facilities.