Development and viscosity modeling of silicone oil/EG–water (10:90) hybrid fluids for heat transfer applications Abdulah, Amri; Shieddieque, Apang Djafar; Khoirudin; Sukarman
Mechanical Engineering for Society and Industry Vol. 6 No. 2 (2026): Issue in Progress
Publisher : Universitas Muhammadiyah Magelang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31603/mesi.15532

Abstract

Accurate characterization of viscosity behavior is essential for the design of advanced heat-transfer fluids, particularly hybrid emulsions involving immiscible polar and non-polar phases. However, the rheological behavior and molecular interactions of silicone oil/ethylene glycol (EG)–water emulsions stabilized with surfactants remain insufficiently understood. Therefore, this study experimentally investigates the temperature-dependent viscosity and molecular characteristics of low-viscosity Silicone Oil PMX-200 dispersed in an EG–water (10:90 v/v) base fluid stabilized with Tween 80 over a temperature range of 30–70 °C. Fourier Transform Infrared (FTIR) spectroscopy was employed to evaluate molecular interactions and emulsion stability, while viscosity measurements were performed using a calibrated rotational rheometer under controlled thermal conditions. FTIR analysis confirmed characteristic polydimethylsiloxane (PDMS) absorption bands associated with C–H, Si–CH₃, and Si–O–Si vibrations. The attenuation of Si–O–Si intensity and the appearance of broad O–H stretching bands indicated enhanced interfacial interactions between the hydrophobic silicone-oil phase and the polar EG–water medium, confirming successful emulsification by Tween 80. Rheological measurements showed that viscosity decreased significantly with increasing temperature, from 6.2 mPa·s at 30 °C to 4.2 mPa·s at 70 °C. The emulsions exhibited nearly Newtonian behavior with flow behavior indices close to unity (n ≈ 1), indicating minimal shear-rate dependence within the investigated range. The viscosity–temperature relationship followed Arrhenius-type behavior, with activation energies decreasing from 8.93 kJ·mol⁻¹ for SO‒50 to 4.86 kJ·mol⁻¹ for SO‒10, indicating enhanced molecular mobility at lower silicone-oil concentrations. Experimental deviations remained below 2% compared with literature data, confirming measurement reliability. The novelty of this work lies in integrating FTIR molecular characterization, rheological validation, and Arrhenius-based viscosity modeling for silicone oil/EG–water emulsions. The proposed correlation provides reliable viscosity prediction for thermal-fluid design and CFD-based heat-transfer simulations.
COMMUNITY EMPOWERMENT IN CIJOGED VILLAGE THROUGH THE UTILIZATION OF PINEAPPLE LEAF WASTE AS LOCAL RAW MATERIAL FOR INNOVATIVE HANDICRAFT PRODUCTS Irwan Suriaman; Rohman Rohman; Wanwan Jamaludin; Apang Djafar Shieddieque; Muhammad Lukman Abdullah; Muhammad Azka Nurul Adzima; Hadad Marwan; Erik Mulyana
Abdi Dosen : Jurnal Pengabdian Pada Masyarakat Vol. 10 No. 3 (2026): SEPTEMBER
Publisher : LPPM Univ. Ibn Khaldun Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/abdidos.v10i3.3549

Abstract

Cijoged Village, located in Subang Regency, is one of the areas that generates a considerable amount of pineapple leaf waste during each harvest season. However, this agricultural waste has not been optimally utilized by the local community and therefore has not provided significant economic value. The Community Service Program (PkM) through the Program Inovasi Seni Nusantara (PISN) was designed to enhance community knowledge and skills in processing pineapple leaf waste into handicraft products with high economic value while encouraging the development of local potential-based enterprises. The initial stage of the program included field observations, community outreach, educational sessions, packaging training, and the provision of a decorticator machine. The activity was conducted over one day and involved approximately 30 participants. The results indicated that participants gained a better understanding of the potential of pineapple leaf waste as a primary raw material for handicraft production, as well as the importance of product innovation and packaging in increasing market value. Throughout the activity, participants demonstrated strong enthusiasm for participating in subsequent training and implementation stages. This program is expected to serve as an initial step in encouraging communities to utilize pineapple leaf waste more effectively, create value-added products, reduce agricultural waste, and improve the local economy in a sustainable manner.
Heat Transfer Fluid Deposit in Retainer of Mechanical Seal Yadi Heryadi; Amri abdulah; Apang Djafar Shieddieque; Dede Ardi Rajab; Heri Suripto; Dibyo Setiawan; Agus Solehudin
Jurnal Teknologika Vol. 15 No. 1 (2025): Jurnal Teknologika
Publisher : Sekolah Tinggi Teknologi Wastukancana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51132/teknologika.v15i1.450

Abstract

Mechanical seals in industrial pumps play a critical role in preventing heat transfer fluid leakage, especially under high-temperature operating conditions. A key component of this system is the seal head, which functions as a compression mechanism through a spring to maintain contact between sealing surfaces. However, the spring's performance can deteriorate due to the accumulation of deposits resulting from prolonged exposure to elevated temperatures, operating pressure, and fluid degradation—ultimately leading to seal failure and fluid leakage. This study aims to investigate the thermal stability of the reservoir fluid Therminol 66 (TM-66) and its impact on seal performance under long-term thermal exposure. The methodology includes direct observation of failed seals, thermogravimetric analysis (TGA) at temperatures of 75, 150, 250, and 350?°C for durations of 3, 6, and 12 hours, and chemical characterization using Fourier Transform Infrared Spectroscopy (FTIR). Additionally, thermal degradation behavior was assessed through activation energy estimation based on weight loss data obtained from TGA. FTIR results revealed that phenylcyclohexane is the dominant compound in TM-66, with a relative intensity of 0.803119. The thermogravimetric data demonstrated that higher temperatures and longer exposure times significantly accelerated fluid evaporation and mass loss. The activation energy analysis confirmed that thermal degradation is more likely to occur under extended high-temperature conditions. These findings highlight the importance of maintaining reservoir fluid temperature below 75°C to minimize deposit buildup in the seal chamber and ensure the long-term reliability and efficiency of the mechanical seal system.
Pengaruh Modifikasi Pipa Pendingin Terhadap Efektivitas Induced Draft Cooling Tower LBC-50 Muhammad Fairuz Naufal; amri abdulah; Yadi Heryadi; Apang Djafar Shieddieque; Dede Ardi Rajab; Sri Suhartini
Jurnal Teknologika Vol. 15 No. 2 (2025): Jurnal Teknologika
Publisher : Sekolah Tinggi Teknologi Wastukancana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51132/teknologika.v15i2.540

Abstract

This study aims to analyze the performance enhancement of an induced draft cooling tower through modifications to the water distribution piping line, as well as to evaluate the thermal and hydraulic performance before and after modification. The initial system exhibited relatively low cooling effectiveness due to uneven water distribution and limited heat transfer between air and water within the tower. Therefore, the piping layout was redesigned to improve flow uniformity, enlarge the air–water contact area, and minimize heat losses, thereby enhancing overall cooling efficiency. The experimental tests were conducted under identical operating conditions with an inlet water temperature of 38 °C. The results showed that the outlet water temperature decreased from 33.78 °C (before modification) to 28.95 °C (after modification). The range increased from 5.17 °C to 9.12 °C, while the approach decreased from 4.68 °C to 2.61 °C, indicating a more effective cooling process approaching ideal conditions. Furthermore, the cooling capacity showed a substantial increase from 21,717.4 kW to 61,515.1 kW, signifying that the modified cooling tower can dissipate a greater amount of heat and support higher cooling demands in industrial operations. In addition, the system effectiveness improved from 52.45% to 77.58%, demonstrating a significant enhancement in heat transfer efficiency as a result of improved fluid distribution. On the other hand, the total head loss increased from 39.11 m to 63.71 m, indicating higher flow resistance due to the new configuration, but it remained within acceptable limits. Overall, the study concludes that modifying the piping line in the induced draft cooling tower significantly improves thermal performance, cooling effectiveness, and capacity, making the redesigned configuration a viable approach to increase the efficiency of large-scale industrial cooling systems..