Cooling System Performance Comparison of Refrigerant R-134a and MC-134 on Ice Slush Machine Rizki Muliawan; Azel Adnal A; Tandi Sutandi; Nurrohman Nurrohman
FLYWHEEL : Jurnal Teknik Mesin Untirta Volume 7, Issue 1, April 2021
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/fwl.v0i0.9237

Abstract

Ice Slush Machine uses a direct cooling vapor compression system. The primary refrigerant used in such a system mostly is hydrofluorocarbons (HFCs), such as R134a. R134a is a retrofit for refrigerant R-12 which is included in the chlorofluorocarbon (CFC) type of refrigerant. CFC-type refrigerants have a dangerous impact on the environment. Hydrocarbon refrigerant MC-134 is an alternative for R-134a because it has a low potential value for environmental damage. The secondary refrigerant used was propylene glycol and the product used was 3.5 liters of Coca-Cola. From the test results when the system using R134a had an average COPactual and an average COPcarnot of 2.6 and 4.55, respectively, and the energy consumption was 1.571 kWh with an average efficiency of 57%, while in a system with MC-hydrocarbon refrigerant 134 obtained an average COPactual and an average COPcarnot of 2.8 and 4.5, respectively and the energy consumption of 1.325 kWh with an average efficiency of 62%. Therefore, MC-134a had COP actual greater than R-134 and electrical energy consumption of MC-134 was less than R-134a.
Improvement of Laboratory Capacity in SMK Manangga Pratama Tasikmalaya Rizki Muliawan; Markus Markus; A S Margana; Cecep Sunardi; Nur Khakim; E Erham
ABDIMAS: Jurnal Pengabdian Masyarakat Vol. 5 No. 1 (2022): ABDIMAS UMTAS: Jurnal Pengabdian Kepada Masyarakat
Publisher : LPPM Universitas Muhammadiyah Tasikmalaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (529.711 KB) | DOI: 10.35568/abdimas.v5i1.1664

Abstract

SMK Manangga Pratama consists of several majors including Motorcycle Business Engineering (TBSM), Automotive Light Vehicle Engineering (TKRO), and Sofware Engineering (RPL). In major Automotive Light Vehicle Engineering (TKRO), some subjects discuss the Air Conditioning system (automotive AC and split room AC). The problem is the lack of equipment for vacuuming, and charging refrigerants for automotive AC units to be used and empowered as a learning resource. The main cause is the lack of affordable equipment for service, unit maintenance. This of course will be a problem when the students have graduated and need direct application to the Automotive AC system and the room. There are about 110 students from the Automotive Light Vehicle Engineering (TKRO) Department in each batch, with such a large number, it would be better if they were given an additional briefing on these skills. This PkM program has been equipped and provided with equipment and service equipment to be used by students as a training unit in improving their skills. The manufacture of tables and assembly of training units for automotive AC service completeness (charging, pumping, and other tools) will be carried out on the Polban Bandung campus. Instructor trainers in this PkM training program are several teaching staff in the Refrigeration and Air Conditioning Engineering Department, while the unit is a complete unit for automotive air conditioning units and rooms, namely (charging, pumping, and other tools). The implementation of community service activities majoring in refrigeration and air conditioning engineering POLBAN as a form of higher education tri dharma has been completed on October 28-29 at SMK Manangga Pratama. The activity consisted of making practicum tools for strengthening school laboratories, accompanied by providing training for the service and maintenance of air conditioning machines (AC).
PEMANFAATAN TEKNOLOGI THERMAL ENERGY STORAGE NON-MEKANIK SEBAGAI PENGERING BAHAN PANGAN SINGKONG Rizki Muliawan
Jurnal Teknologi Terapan Vol 7, No 2 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i2.334

Abstract

A drying machine is a machine that is used to dry some food or product. The process of heating can be used to preserve some products because drying reduces moisture content in the product and bacterial can’t live without water. Solar pond system will use for the machine which caught and trap the heat from the sun. The fluid in a pond of solar pond system is saltwater and the salinity will be varied. The variation of saltwater will be 3.5%, 5%, and 7%. In the solar pond system, some coils will circulate the water towards the cabin. The coil is made of copper pipe which has a length of 20.5 meters. This coil serves as a heat exchanger charged with the heat exchange process in the solar pond system. The water in this coil is circulated by a water pump. Water is circulated to the heat exchanger which is just below the cabin. The product used is 500 grams of cassava. Cassava is dried with the skin peeled and sliced about 2 mm thick. From the experiments that have been done obtained the best saltwater concentration is 7% with a tub temperature lower by 40 °C, the cabin temperature reaches 34.1 °C, and the water reduced of product weight by 210 grams. The COPactual heating average obtained by this machine is 1,15 and the COPcarnot heating average obtained by this machine is 29,80. The efficiency average that obtained by this machine is 3,77%.
PEMBEKALAN KOMPETENSI SISWA PADA BIDANG TEKNIK REFRIGERASI DISERTAI DENGAN PEMBERIAN UNIT TRAINER DI SMK MANANGGA PRATAMA KOTA TASIKMALAYA TAHUN 2020 Rizki Muliawan
Jurnal Difusi Vol 4 No 2 (2021): Jurnal Difusi
Publisher : Pusat Penelitian dan Pengabdian Masyarakat (P3M) Politeknik Negeri Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (782.133 KB) | DOI: 10.35313/difusi.v4i2.2216

Abstract

Abstrak SMK Manangga Pratama terdiri dari beberapa jurusan diantaranya JBSM, TKRO dan Rekayasa Perangkat Lunak. Menurut kurikulum dan informasi dari beberapa staf pengajar di sana jurusan Teknik Kendaraan Ringan Otomotif (TKRO) terdapat mata pelajaran yang membahas sistem Air Conditioning (A/C otomotif dan A/C split). Permasalahannya adalah tidak memiliki unit A/C split untuk digunakan dan diberdayakan sebagai sumber pembelajaran. Penyebab utamanya adalah mahalnya training unit (trainer) yang dapat mencapai kisaran ± Rp 25 Juta / unit. Hal ini tentunya akan menjadi (gap) masalah ketika para siswa sudah lulus dan perlu penerapan langsung terhadap sistem A/C split. Lulusan Jurusan Teknik otomotif ringan setiap angkatannya sekitar 110 orang siswa, dengan jumlah yang demikian banyak akan lebih baik apabila diberikan pembekalan tambahan mengenai keahlian tersebut. Program pengabdian kepada masyarakat dengan memberikan pengetahuan (knowledge) dan keahlian (skill) kepada para siswa, sehingga luarannya para siswa akan memiliki pengetahuan dan pemahaman serta praktik tentang A/C split. Program PkM ini juga diberikan satu buah training unit A/C split berikut peralatan servisnya untuk dapat digunakan oleh para siswa sebagai trainer untuk training dalam meningkatkan keterampilannya. Pembuatan alat berupa trainer unit A/C Split dilakukan di dalam Kampus Polban sendiri. Yang menjadi instruktur dalam program pelatihan PkM ini adalah beberapa staf pengajar di Jurusan Teknik Refrigerasi dan Tata Udara sedangkan trainer unitnya adalah satu buah A/C split dan kelengkapan servisnya. Langkah selanjutnya adalah dengan pemberian modul (jobsheet) praktikum, untuk memudahkan pada saat proses praktek siswa dan guru pada nantinya. Pengetahuan siswa diuji terlebih dahulu dengan melakukan pre-test diakhiri dengan post-test, hal ini dilakukan untuk mengetahui kemampuan siswa. Peningkatan (gain) hasil praktikum diharapkan setelah diadakan kegiatan PkM ini. Kata Kunci : SMK Manangga Pratama, PkM, Pembekalan, kompetensi, A/C Split
Kaji Numerik Penggunaan Subcooler LSHX pada Refrigeran R22 dan R290 dengan Variasi Temperatur Evaporasi Hassan Muhammad Sumeru; Triaji Pangripto Pramudantoro; Rizki Muliawan
Prosiding Industrial Research Workshop and National Seminar Vol 13 No 01 (2022): Vol 13 (2022): Prosiding 13th Industrial Research Workshop and National Seminar
Publisher : Politeknik Negeri Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (243.169 KB) | DOI: 10.35313/irwns.v13i01.4312

Abstract

Refrigeran R22 sudah lama digunakan sebagai fluida kerja pada pengkondisi udara (AC) maupun mesin pendingin (freezer). Namun, kekurangan R22 adalah pada segi lingkungan, karena masih memiliki nilai ODP dan GWP yang masih relatif tinggi. Sehingga, penggunaan R22 sebagai fluida kerja harus dihentikan dan diganti dengan refrigeran yang lebih ramah lingkungan. Salah satu refrigeran pengganti R22 adalah R290. Refrigeran R290 memiliki nilai ODP nol dan nilai GWP yang kecil. Dari sisi tekanan kerja, R290 tidak berbeda jauh dengan R22. Salah satu metode peningkatan sistem refrigerasi dengan menggunakan metode Liquid Suction Heat Exchanger. Di lapangan efektivitas penggunaan LSHX mempengaruhi derajat subcooling. Pada penelitian ini dapat terlihat perbandingan efektivitas penggunaan LSHX pada kinerja sistem refrigerasi dengan memvariasikan derajat subcooling dan superheating yaitu 2, 4, 6, 8, dan 10 K. Selain itu, penelitianini memvariasikan temperatur evaporasi 5oC yang mewakili temperatur pengkondisi udara dan temperatur evaporasi -10oC, -20oC, -30oC dan -40oC yang mewakili temperatur freezer. Hasil simulasi menunjukkan setiap kenaikan temperatur superheating dan subcooling sebesar 2 K pada R22 dan R290 membuat nilai temperatur discharge meningkat sebesar 2,44% dan 3,01%, nilai kerja kompresi meningkat sebesar 0,98% dan 1,05%, nilai efek refrigerasi meningkat sebesar 2,53% dan 3,35% dan nilai COPaktual meningkat sebesar 1,51% dan 2,27%.
Facilities Development with Training of Instructors in Maintenance and Display Case Repair in the Work Training Center (BLK) of Kuningan District Triaji PP; Rizki Muliawan; Apip Badarudin; AR Lukitobudi; AP Edi S
Jurma : Jurnal Program Mahasiswa Kreatif Vol 6 No 2 (2022): Desember 2022
Publisher : LPPM UIKA Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/jurma.v6i2.1562

Abstract

The Kuningan West Java Vocational Training Center (BLK) is ready to create manpower to fill the world of work or independent businesses, to reduce unemployment rates. The condition of work training centers that have new buildings but are not yet supported with adequate equipment and human resources and according to needs still require support from stakeholders to improve their quality. Bandung State Polytechnic, especially the Department of Refrigeration and Air Conditioning Engineering, is experienced enough and feels the need to contribute to the development program of the BLK Kuningan, especially in the field of Facilities Development and Instructor Training in the Field of Maintenance and Repair of Display Cases at BLK Kuningan Regency. This program aims to increase the role of the BLK in increasing the competence of Human Resources according to the needs of the labor market. The method implemented is through the Facility Development and Instructor Training Program in the Field of Maintenance and Repair of Display Cases. This activity has been carried out in theory and practice with a ratio of 20% theory and 80% practice in the field which was held at BLK Kuningan. The outputs that have been achieved include training participants having sufficient competence as instructors in the field of refrigeration and air conditioning engineering, especially regarding maintenance and repair of display case machines, availability of job sheets and theory and practice modules on basic refrigeration, especially for display case machines, a set training unit display case and its service equipment.
INVESTIGASI EKSPERIMENTAL PERFORMA SISTEM PENDINGIN MULTI-TERMOELEKTRIK DENGAN KONFIGURASI TERMAL SERI DAN PARALEL Bowo Yuli Prasetyo; Apip Badarudin; A.P. Edi Sukamto; Rizki Muliawan
Jurnal Teknologi Terapan Vol 8, No 2 (2022): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v8i2.427

Abstract

Thermoelectrics can convert electrical energy to thermal energy. The generated thermal energy can be used in various cooling systems (TEC) applications. Improvement of TEC performance influenced by hot-side heat dissipation method, working fluid, and multi-thermoelectric. This study aims to investigate the relation between multi-thermoelectric configuration and the cooling behaviors. The experiment was conducted on the devices equipped with two modules of TEC arranged in series and parallel with variations of input voltage, working fluid mass flow, and temperature. The result reveals variations in cooling behaviors between the two configurations. Parallel configuration TEC gives the highest cooling capacity with a value of 66.62 W, 100% bigger than the series configuration. Meanwhile, the series configuration provides a delta temperature of 11.03 K, 2% higher than the parallel one. The parallel modules cooling performance is the biggest among the two arrangement, with a value of 2.57, which is 147% higher than series one.
Metode Praktis Perancangan Panjang Pipa Evaporator pada Mini Freezer Bertemperatur Rendah Menggunakan Refrigeran R404A Kasni Sumeru; Markus Markus; Nanda Fauzan Pratama; Rizki Muliawan; Yudi Prana Hikmat
Jurnal Rekayasa Mesin Vol 18, No 1 (2023): Volume 18, Nomor 1, April 2023
Publisher : Mechanical Engineering Department - Semarang State Polytechnic

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32497/jrm.v18i1.3878

Abstract

Mini freezer yang terdapat di pasaran umumnya memiliki temperatur kabin hanya sampai -20oC. Penelitian ini bertujuan menampilkan metode perhitungan panjang pipa evaporator sehingga dapat mencapai temperatur kabin hingga -40oC dengan menggunakan refrigeran R404A. Refrigeran R404A selain relatif lebih ramah lingkungan dibandingkan dengan R22, juga memiliki temperatur Normal Boiling Point (NBP) lebih rendah dari R22. Kapasitas kompresor yang digunakan adalah 250 W yang khusus dirancang untuk refrigeran R404A. Berdasarkan pengujian didapatkan bahwa temperatur kabin dapat mencapai -40oC setelah 120 menit mesin pendingin dioperasikan. Selama beroperasi, tekanan kerja, yaitu tekanan suction dan discharge kompresor, mini freezer hampir sama dengan hasil perhitungan. Ini artinya metode yang digunakan pada penelitian ini dengan desain dan pengembangan (R&D). Namun untuk mendapatkan freezing time yang lebih singkat masih diperlukan optimasi panjang pipa evaporator masih diperlukan, supaya temperatur kabin -40oC dapat dicapai lebih singkat. Perbedaan hasil perancangan, yaitu: tekanan suction, tekanan discharge dan temperatur discharge, dengan hasil pengujian tidak lebih dari 10%.
Rancang Bangun Sistem Refrigerasi Mini Freezer dengan Menambahkan Pre-cooler Air Kondensat pada Pipa Discharge Hidayat, Muhamad Ardi; Muliawan, Rizki; Pramudantoro, Triaji Pangripto
Prosiding Industrial Research Workshop and National Seminar Vol. 14 No. 1 (2023): Vol 14 (2023): Prosiding 14th Industrial Research Workshop and National Semina
Publisher : Politeknik Negeri Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35313/irwns.v14i1.5359

Abstract

Sub-cooling merupakan proses penurunan temperatur refrigeran setelah melalui titik saturasi liquid pada keluaran kondenser dan wujud refrigerannya disebut subcooled liquid. Biasanya, air kondesat pada lemari es maupun mini freezer akan dibuang. Namun pada penelitian ini air kondensat akan dimanfaatkan untuk mendinginkan pipa discharge sehingga diharapkan refrigeran akan mengalami Sub-cooling. Sub-cooling dapat meningkatkan efek refrigerasi dan meminimalkan penggunaan daya listrik. Pada penelitian ini metode yang digunakan ialah penggunaan air kondensat. Sistem yang digunakan merupakan mini freezer dengan kompresor hermetik jenis reciprocating berkapasitas 1/8 PK dan refrigeran R134a. Setelah dilakukan pengukuran data selama 180 menit atau 3 jam diperoleh peningkatan performansi sistem refrigerasi dimana sistem tanpa pre-cooler memiliki COP aktual sebesar 1,839, COP Carnot sebesar 3,771, efisiensi sebesar 48,76% dan konsumsi daya listrik sebesar 1,937 kWh. Sedangkan sistem dengan pre-cooler memiliki COP aktual sebesar 1,908, COP Carnot sebesar 3,759, efisiensi sebesar 50,75%, dan konsumsi daya listrik sebesar 1,859 kWh. Sistem dengan pre-cooler memiliki peningkatan efisiensi sebesar 1,99% dan penurunan konsumsi daya listrik sebesar 4,026%.
Analisis Pengaruh Variasi Kecepatan Fan Kondenser Terhadap Performansi Sistem Brine Cooling Untuk Pembuatan Es Balok Ramdhani, Muhammad Rizal; Muliawan, Rizki; Khakim, Nur
Prosiding Industrial Research Workshop and National Seminar Vol. 14 No. 1 (2023): Vol 14 (2023): Prosiding 14th Industrial Research Workshop and National Semina
Publisher : Politeknik Negeri Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35313/irwns.v14i1.5376

Abstract

Brine Cooling merupakan sistem refrigerasi yang metode pendinginnanya secara tidak langsung (Inderect Expansion System) dimana prosesnya menggunakan bantuan refrigeran sekunder yang dikenal dengan larutan brine. Pada sistem ini kondenser dilengkapi oleh sebuah fan yang memiliki kecepatan fan sebesar 4,5 m/s. Dilakukan analisis pada penelitian ini dengan menambahkan dimer yang bertujuan untuk mengetahui perbandingan kinerja sistem dengan mengatur kecepatan fan pada putaran tinggi, sedang dan rendah. Pada penelitian ini melakukan analisis pada sistem brine cooling untuk mengetahui kinerja sistem dan berapa lama temperatur produk akan tercapai, pada penelitian ini Nilai COPActual dan COPCarnot yang didapat saat menggunakan variasi kecepatan putaran kipas tinggi dengan kecepatan 4,5 m/s sebesar 3,32 dan 4,51 dan untuk efisiensi sistem sebesar 73% dan konsumsi energi listrik yang digunakan yaitu sebesar 1,1997 kWh, untuk variasi kecepatan putaran kipas sedang dengan kecepatan 4m/s nilai COPActual dan COPCarnot yang didapat sebesar 3,13 dan 4,32 dan untuk efisiensi sistem sebesar 72% dan konsumsi energi listrik yang digunakan sebesar 1,229 kWh, untuk variasi kecepatan putaran kipas rendah dengan kecepatan 3,5 m/s nilai COPActual dan COPCarnot yang didapat sebesar 2,75 dan 3,95 dan untuk efisiensi sistem sebesar 69% dan konsumsi energi listrik yang digunakan sebesar 1,2584 kWh. Hal ini membuktikan bahwa kinerja sistem brine cooling yang terbaik pada saat menggunakan variasi kecepatan putaran fan kondenser tinggi dikarenakan proses penyerapan kalornya bekerja secara optimal.