Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Jurnal Energi dan Teknologi Manufaktur

Perencanaan Turbin Air Kapasitas 2 x 1 MW di PLTM Cianten 1 Kabupaten Bogor Asrori .; Eko Yudiyanto
Jurnal Energi dan Teknologi Manufaktur Vol 1 No 01 (2018)
Publisher : Polinema Press, Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/jetm.v1i01.4

Abstract

Minihidro Cianten 1 Power Plant (PLTM C-1) capacity 2 x 1 MW, located in Cianten river, Cibunian village, Pamijahan district, Bogor district. Preliminary planning data is with design head (Hd) = 27.7 m, design discharge per unit (Qd) = 4.0 m3 / s, power house elevation = +529,0 m. Turbine planning includes calculation of rated power output, type selection and number of turbines, specific speed velocity and runaway speed, runner diameter, turbine elevation setting, spiral casing and draft tube dimensions and pre-powerhouse design. Turbine performance and stability including pressure rise, speed rise and weighted average efficiency are also planned. Planning is based on calculations from international standard hydro powerplant planning guidance. The results of the calculations are verified by software and catalog of turbine manufacturers. The turbine specification results are as follows: 2 horizontal francis units, rated output power / unit (Pr) = 1000 kW (1 MW), turbine spin (n) = 600 rpm, turbine efficiency (T) = 0.92, (ns) = 298.6 rpm (M-kW), runaway speed = 1219 rpm, runner diameter = 0.769 m, runner weight (WR) = 294.05 kg, total turbine weight (WT) = 3060,37 kg. The stability of turbine operation is declared safe where the value of speed rise and pressure rise are 44.39% and 19.39% respectively. While the performance as a warranty from turbine manufacturers expressed with the value of weighted average efficiency of 88.67%.
Pengujian Rasio Kinerja Instalasi Panel Surya Tipe Silikon–Kristal pada Kondisi Cuaca Kota Malang Asrori Asrori; Imam Mashudi; Suyanta Suyanta
Jurnal Energi dan Teknologi Manufaktur Vol 2 No 02 (2019)
Publisher : Polinema Press, Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/jetm.v2i02.41

Abstract

Indonesia has the potential of global solar radiation reaching 4.5 to 5.5 kWh /m2/day. Due to this fact, the utilization of solar energy using solar panel technology is an alternative to use energy from renewable resources. In the present study, the performance of crystalline silicon solar panels (mono and polycrystalline) under malang city climate (7,944o S ;112,613o E) were experimentally compared. The solar radiation, ambient temperature, current and voltage output, were monitored to determine normalized power output efficiency and the performance ratio of the two different solar panels. The obtained results indicate that the performance of solar panel is influenced by solar radiation, weather condition (cloudy and clear day), wind velocity and type of solar panel installation. Finaly, the normalized power output efficiency of the mono and polycrystalline by 70.79% and 66.33%, respectively. In addition, the performance ratio of mono and polycrystalline by 0.63 and 0.61, respectively. Its showed that, the performance of mon