VERIFIKASI PENGUKURAN RADIOAKTIVITAS 153Sm MENGGUNAKAN DOSE CALIBRATOR MULTITIPE Ligwina Dita Pertiwi; Maskur Maskur; Yanto Yanto; Nuha Fairusya; Nuri Jannati Wahyu Ekaningsih
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 29 No. 2 (2023): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2023.29.2.6838

Abstract

Measurement verification is crucial to ensure measurement results validity. In this study, we have done verification on 153 Sm radioactivity using five different types of dose calibrators dose calibrator Atomlab 100, Atomlab 300, Atomlab 400, Atomlab 500, and Capintec CRC-tR5. The parameters of verification process including accuracy, precision, linerity, Limit of Detection (LOD), and Limit of Quantification (LOQ). The dose calibrator Atomlab 300 was established as the standard instrument to examine the others type of dose calibrator accuracy. Verification results showed all the instruments have an error of less than 3%. However, the t-test results exhibited only the dose calibrator Atomlab 400 that had tvalue less than the corresponding ttable value. In contrast, Atomlab 100, Atomlab 500, and Capintec CRC tR5 produced a tvalue greater than a ttable value. In the precision test, all types of dose calibrator gave a satisfactory precision results. All five-dose calibrators demonstrated good linearity for measuring radioactivity within the range of 20-140 mCi. The LOQ values for each dose calibrator were as follows dose calibrator Atomlab 100 = 7,88 µCi, Atomlab 300 = 12,65 µCi, Atomlab 400 = 17,32 µCi, Atomlab 500 = 15,06 µCi, and Capintec CRC tR5 = 18,6 µCi. As well as the LOQ values of the dose calibrator were determined as calibrator Atomlab 100 = 2,74 µCi, Atomlab 300 = 1,14 µCi, Atomlab 400 = 8,2 µCi, Atomlab 500 = 6,79 µCi, and Capintec CRC tR5 = 7,38 µCi. These showed that five dose calibrator types offer reliable measurement validity with a 95% confidence level. Nevertheless, it is necessary to employ a correction factor for Atomlab 100, Atomlab 500, and Capintec CRC tR5.
PENENTUAN KEMURNIAN RADIOKIMIA 99mTc-MIBI SECARA CEPAT DAN PRAKTIS MENGGUNAKAN DOSE CALIBRATOR Maskur Maskur; Enny Lestari; Endang Sarmini; Yayan Tahyan; Amal Rezka Putra; Dede Kurniasih; Adang Hardi Gunawan
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 23 No. 1 (2017): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2017.23.1.3195

Abstract

Generally, the determination of radiochemical purity begins with Radiochemical separation using thin layer chromatography (TLC), and then measurement using a gamma counter, but this method cannot be applied in hospitals since there is only a dose calibrator available in the hospitals. Therefore, we conducted such an investigation using an alternative method which is more practical and faster, ie begins with radiochemical separation using extraction method, and then measurement using a dose calibrator. The determination was carried out in which 99mTc-MIBI was extracted using a mixture of saline and chloroform with volume ratio of 1:1, the mixture was then extracted. The 99mTc - MIBI was in organic phase (chloroform), whereas 99mTcO2 and 99mTcO4- were both in water phase (saline). Then, each phase of the sample was taken with the same volume, and then the radioactivity was measured using a gamma ionization chamber and the radiochemical purity was calculated. Radiochemical purity with extraction process method Compared measuring using standard methods of TLC Furthermore, the results of the extraction were compared with the standard method of TDC. The results showed that the radiochemical purity of 99mTc-MIBI using the two methods were almost the same, ie =98.34 % ± 0, 65 % for TLC standard method and = 97.15 % ± 0,56 % for extraction method with good measurement precision. The time of determination for extraction method was 20 minutes and 180 minutes for TLC standard method respectively. These results indicated that the extraction method can be used as an alternative method for determination of radiochemical purity of 99mTc-MIBI radiopharmaceutical. The advantage of extraction method that it is faster compared to the TLC Method.
PEMBUATAN SENYAWA BERTANDA 131I-MIBG DENGAN PENINGKATAN DOSIS TERAPI Maskur Maskur; Chairuman; Yono Sugiharto; Khoirunnisa Fauziah Asyikin; Triningsih; Sulaiman
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 27 No. 1 (2021): Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2021.27.1.6358

Abstract

Nowadays, the labeled compound of 131I-MIBG has been successfully produced in Indonesia. However, the concentration of radioactivity and dose of radioactivity per vial is still small when compared to commercial products from abroad available in the market. Currently, the dose of radioactivity achieved is 25 mCi/vial with a concentration of 5 mCi/mL. Problems arise if the radioactivity and dose of radioactivity per bottle are enlarged, where the product becomes unstable and breaks down because of the effects of radiolysis. The generally global commercial products contain a dose of radioactivity = 100 mCi/vial with a concentration of 10 mCi/mL. By this research efforts have been made to increase the concentration and dose of radioactivity per bottle. The method used was by increasing the amount of benzyl alcohol from 9 μL/mL to 10 μL/mL of 131I-MIBG solution. Other than that, the addition of phosphate buffer which was originally added before the purification process was switched to after the purification process. The result of labeling was 131I-MIBG 153 - 254 mCi with process yield between 33.60 and 51.94%. The radioactivity concentration was quite large, i.e., between 9.80 to 25.40 mCi/mL with radioactivity doses ranging from 100 to 222 mCi/vial. However, to adjust to market needs, the I-MIBG of Batan product was then packaged in 100 mCi/vial with a concentration of 5-13 mCi/mL.This workaround shows that the synthesis of labeled compound of 131I-MIBG for scale up therapeutic dose has been successfully carried out.