Pulmonary Sound Design Using Max 9814 Sensor with Nextion View Febrianti, Fani; Setioningsih, Endang Dian; Utomo, Bedjo; sumber, sumber
Jurnal Teknokes Vol. 16 No. 3 (2023): September
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study aims to develop a tool that can assist nurses in examining patients by displaying sounds and signals on a TFT LCD screen. This tool uses the MAX 9814 sound sensor, which converts sound into an electrical signal. This sensor will generate a voltage when the diaphragm inside it moves back and forth. To design this tool, researchers used a series of high pass filters and low pass filters with a cut-off frequency of 333 Hz - 714 kHz. During testing of this tool using the MAX 9814 sensor mounted on a stethoscope, the signal appears stable on the TFT LCD screen and sound can be played properly. However, if the placement of the stethoscope is not correct during the examination, this can also affect the signal and sound produced. This tool should not produce a clear and loud sound when checking, because if this happens, the inspection cannot be carried out optimally. This research also produces a signal shape that is almost similar to the signal on the phantom. It is important to note that the MAX 9814 can work optimally if it is not exposed to environmental noise. Therefore, if this equipment is used in a noisy environment, the signal and sound produced may be disturbed by environmental noise. This research was conducted with the aim of making it easier for doctors and nurses to carry out portable examinations, as well as to monitor signals and sounds easily.
IoT-Based Human Vital Sign Monitoring Tool Using Telegram Notifications Dwi K, Rizky; Assalim Tetra Putra, Moch. Prastawa; Kholiq, Abdul; Utomo, Bedjo; sumber, sumber; Triwiyanto, Triwiyanto; Rathod, Yagnik
Jurnal Teknokes Vol. 16 No. 3 (2023): September
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Vital signs play a crucial role in monitoring the progress of adult or pediatric patients during hospitalization, as they enable prompt detection of delayed recovery or adverse events. Vital signs are measured to obtain fundamental indicators of the patient's health status. The measurement of vital signs, including blood pressure, temperature, pulse, and respiratory rate, is the most common intervention in hospital medicine. Advanced monitoring systems combine clinical and technological aspects to deliver innovative healthcare outcomes. Remote patient monitoring systems are increasingly becoming the cornerstone of healthcare delivery, replacing traditional manual recording with computer and smartphonebased electronic recording as a versatile and innovative health monitoring system. This study aims to design a Vital Sign Monitoring Parameter BPM and RR tool with Notifications via the IoT-Based Telegram application. The tool enables the monitoring of vital signs, particularly BPM and RR, regardless of the patient's location and at any given time. This allows doctors, health workers, and patients to stay informed about their health condition. Real-time display of vital sign data is available through the TFT LCD screen, and the data from the screen can be accessed via Telegram. The Telegram application will send notifications in the event of abnormal patient conditions. MAX30100, a digital sensor for detecting breathing rate and heart rate, is utilized in this research. Furthermore, the data obtained shows errors that are within the allowable limits for each parameter. The difference between the heart rate readings and the respiratory rate values on the device and the patient monitor is 1.14% for heart rate and 0.84% for respiratory rate. This study indicates that it is time to monitor vital signs that can be seen remotely and have a system that is an inexpensive and easy-to-operate device for health workers without interfering with activities of daily living.
Electronic Stethoscope Equipped with IoT-based Remote Monitoring to Detect Disease Symptoms Hamzah, Torib; Setioningsih, Endang Dian; Sumber, Sumber; Ragimova, Nazila
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 4 (2022): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.157

Abstract

Auscultation is a technique or method most often used by medical personnel in the initial examination of patients. One way to carry out this method is by using a stethoscope. However, this method has its drawbacks because the diagnosis is carried out subjectively and cannot be relied on with the accuracy to diagnose the symptoms of heart defects. Thus, the purpose of this study was to create an IoT system for electronic stethoscopes with BPM value output and make analog filters to eliminate noise interference which was a major obstacle in previous studies. The contribution of this research is to make it easier for medical users to analyze heart rate using an electronic stethoscope while at the same time being able to know the number of BPM automatically that can be monitored remotely because it used IoT system. Furthermore, the method used in this study was by using a mic condenser placed on the patient's chest to detect pressure changes. When the pressure changes, the voltage output value on the condenser mic also changes. In this case, the output from the condenser mic went in and follows the analog signal conditioning circuit. The output signal from the analog signal conditioning further entered the programmed microcontroller. Furthermore, based on the measurement conducted, the error value of BPM was obtained from the five respondents. In this case, the error value generated from respondent 1 was 0.33 BPM, the error value obtained from respondent 2 was 0.67 BPM, the error value obtained from respondent 3 was 0.5 BPM, the error value obtained from respondent 4 was 0.67, and the error value obtained from respondent 5 was 0.67 BPM. Meanwhile, the results of the statistical test obtained P-Value of more than 0.05, indicating that the resulting value did not have a significant difference.
Analysis of Temperature Distribution in Blood Banks Through Storage of Measurement Results with IoT Monitoring in the Blood Donation Unit of Indonesian Red Cross Surabaya Wardhana, Farisy Azis Satria; Maghfiroh, Anita Miftahul; Titisari, Dyah; Sumber, Sumber; Abdullayev, Vugar
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 2 (2023): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.170

Abstract

Temperature or temperature is an indicator of the degree of heat of an object. Cold chain or cold chain is a supply chain system that considers the temperature level in the process. Cold chain to keep frozen or chilled products in an environment with a certain temperature during production, storage, transportation, processing and sales. This is intended to maintain product quality. The purpose of this study was to determine the temperature distribution in the Blood bank at Blood Transfusion Unit Indonesian Red Cross Surabaya City which was used for storage of blood products. By using the ESP32 system and the DS18B20 temperature sensor which will then be monitored via IoT, it will make it easier for users to monitor. The results of these measurements will be stored in a micro SD card for analysis. The data is processed by Non-Parametric Test resulting in an interpretation that the temperature of each shelf is different due to the difference in the location of the sensor placement. The temperature difference is also influenced by the pattern of use and the process of heat transfer from the bottom to the top of the shelf. This research was considered successful with the result of the highest temperature distribution being 3°C and the lowest being 2°C. The location of these racks can be useful in determining day-to-day monitoring measuring points. This value has met the standard for storage of blood products, which is in the range of 2°C-6°C.
Design of Two Channel Infusion Pump Analyzer Using Photo Diode Detector Syaifudin , Syaifudin; Mak’ruf, Muhammad Ridha; Luthfiyah, Sari; Sumber, Sumber
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 2 (2021): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.207

Abstract

In the medical world, patient safety is a top priority. The large number of workloads and the frequency of using the devices in the long run will affect the accuracy and accuracy of the tool. If the flow rate and volume of the syringe pump or infusion pump given to the patient are not controlled (overdose or the fluid flow rate is too high) it can cause hypertension, heart failure or pulmonary edema. Therefore, it is necessary to have a calibration, which is an application activity to determine the correctness of the designation of the measuring instrument or measuring material. The purpose of this research is to make a two channel infusion device analyzer using a photodiode sensor. The contribution of this research is that the system can display three calibration results in one measurement at the same setting and can calibrate 2 tools simultaneously. The design of the module is in the form of an infrared photodiode sensor for reading the flowrate value. This study uses an infrared photodiode sensor for channels 1 and 2 installed in the chamber. This study uses a flow rate formula that is applied to the water level system to obtain 3 calibration results. Infrared photodiode sensor will detect the presence of water flowing in the chamber from an infusion or syringe pump. Then the sensor output will be processed by STM32 and 3 calibration results will be displayed on the 20x4 LCD. This tool has an average error value on channel 1 of 3.50% and on channel 2 of 3.39%. It can be concluded that the whole system can work well, the placement and distance between the infrared photodiodes also affects the sensor readings
Automatic Blood Collection and Mixer in a Blood Transfusion System Equiped with Barrier Indicators Putra, Chandra Bimantara; Ariswati, Her Gumiwang; Sumber, Sumber; Zahar, Muzni
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 2 No. 2 (2020): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.225

Abstract

A blood collection monitor is a device used to measure and shake the blood bag during a blood transfusion so that the blood in the bag does not clot and is mixed with anticoagulant fluid in the bag properly. This study aims to design an automatic blood collection and mixer for the transfusion blood system. The advantage of the proposed design is accompanied by a safety system in the form of a barrier indicator that is connected to an alarm. The alarm served to give a warning to blood donors if there is an obstacle or there is no increase in volume as much as 20ml for 1 minute as recommended by the world blood bank association. This device can work with three different sizes of blood bags. In this study, a loadcell sensor is used to detect the amount of blood fluid that enters the bag. Furthermore, then it is converted into milliliter volume. In order to collect the blood, a shaker is drove using a motor controlled by Arduino microcontroller. From the measurement, for the entire size of the blood bag, we found that the deviation is 0, UA is 0, and the average error is 0. Thus, it can be concluded that this device can be used properly. In the future, it can be developed a blood infusion with the flowrate measurement to determine the speed of blood during donation
Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor Dwi S, Frendi Agung; Utomo, Bedjo; Sumber, Sumber
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 2 No. 2 (2020): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.228

Abstract

Diabetes mellitus is one of the deadliest diseases faced by Indonesians. To measure blood sugar levels, the most widely used tool is an invasive tool, namely by injuring the patient's body. Techniques like this make people reluctant to measure glucose levels in their blood regularly. Therefore, this research aims to design and build a non-invasive blood sugar measuring device using a photodiode sensor. So that this tool can be used by all groups, both medical and non-medical personnel to measure blood sugar non-invasively. In this study, blood was drawn from several patients with Miletus diabetes and carried out direct blood measurements using a photodiode sensor. The results obtained from this study are that there is an error value in the voltage measurement circuit with the calculation of the resistance value to obtain the voltage value. The error value obtained is 5%, the linear regression value is 0.996. From the measurement results, it can be concluded that the photodiode sensor can be used to measure blood sugar non-invasively
Nine Channel Temperature Data Logger in Measuring the Effectiveness of the Sterilization Process of Medical Instruments with Dry Sterilization Nurul Al Istigho Farola; Her Gumiwang; Sumber Sumber
International Journal of Advanced Health Science and Technology Vol. 1 No. 1 (2021): November
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (283.843 KB) | DOI: 10.35882/ijahst.v1i1.5

Abstract

Measuring the temperature on the dry sterilizer is very necessary because the temperature inside the dry sterilizer has the possibility that the temperature is not the same as the temperature that has been set and is displayed on the display. If the temperature in the dry sterilizer does not match the standard setting temperature for the sterilization process, then the sterilization process is said to be imperfect The purpose of this study is to record and monitor whether the distributed temperature in the sterilization chamber corresponds to the setting temperature. The workings of the temperature data logger tool is that the type K thermocouple temperature sensor will detect the temperature which then enters the analog signal conditioning circuit which then enters the ATMegga 2560 which has been given a program and processed in such a way, then the temperature will be displayed on a 4x20 character LCD. Temperature measurement data will be saved to the SD Card every 10 seconds in the form of a TXT file. This research has been used to record 2 sterilizers and compared with the Madgetech OctTemp2000 data logger. Based on data measurements and comparisons, the average error was obtained at a temperature of 50ºC with the smallest error value of 0.7% and the largest value of 3.9%. At a temperature of 100ºC, the smallest error value is 1.6% and the largest is 10.5%. Then at a temperature of 120ºC the smallest error value is 0.0% and the largest is 8.5%. This research can be used to help analyze the distribution of temperature in a room. With these measurement results, it can be said that this study still has afairly high error value at several measurement points.
Microcontrollers Performance in Portable Electronic Stethoscope Design with a Disease Symptoms Detection Feature Torib Hamzah; Endang Dian Setioningsih; Sumber Sumber; Wahyu Caesarendra
International Journal of Advanced Health Science and Technology Vol. 3 No. 5 (2023): October
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1148.467 KB) | DOI: 10.35882/ijahst.v3i5.12

Abstract

One of the early examinations that is often done is to detect heart disease using a stethoscope. The electronic stethoscope consists of a membrane and tube from a conventional stethoscope coupled with a condenser microphone which is then connected to a computer. The purpose of this study is to analyze the comparison of two types of microcontrollers in the design of a portable electronic stethoscope equipped with a symptom detector. The research method used is instrumentation with 2 types of microcontrollers to design a heart sound detector. In processing the data to be displayed on the 16x2 Character LCD. Sending heart signal data for 60 seconds to produce BPM data which is processed using 2 different types of microcontrollers. The results of data collection on battery consumption of power usage on the AT mega 2560 resulted in an average saving of 0.11W. Therefore, it can be concluded that the two stethoscopes have a significant difference when compared, where the Arduino Mega 2560 is able to process data from heart signals faster than the AT mega 328P. The results of the research that have been carried out can be implemented using a system that strongly supports the needs when checking heart sound signals
Noise Reduction of Motion and EMG Artifacts in Holter ECG Using IIR Filters for Robust Arrhythmia Detection Sumber Sumber; Endang Dian S; Triwiyanto Triwiyanto; Roichatun Nashichah; Vijay Anant Athavale
Journal of Applied Engineering and Technological Science (JAETS) Vol. 7 No. 2 (2026): Journal of Applied Engineering and Technological Science (JAETS)
Publisher : Yayasan Riset dan Pengembangan Intelektual (YRPI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37385/jaets.v7i2.9426

Abstract

Ambulatory Holter electrocardiography (ECG) enables continuous monitoring for detecting transient arrhythmias; however, its diagnostic reliability is significantly degraded by motion artifacts and electromyographic (EMG) interference. Under severe motion artifact conditions, prior studies report that ambulatory ECG SNR can fall below −10 dB , although SNR levels vary substantially depending on activity type and electrode placement, reducing usable data segments and impairing arrhythmia detection. While advanced denoising methods such as wavelet transforms and deep learning achieve high accuracy, their computational complexity limits real-time deployment in resource-constrained embedded systems. This reveals a critical gap in lightweight methods that jointly optimize noise suppression, morphological preservation, and downstream diagnostic performance. This study proposes a computationally efficient IIR Butterworth bandpass filtering framework for real-time IoT-based Holter ECG systems. The system combines three-lead ECG acquisition, embedded processing on an ESP32, and real-time visualization. Performance is assessed using SNR, mean squared error (MSE), Pearson correlation, and confusion matrix-based detection metrics on ten male participants under controlled motion and muscle artifact conditions. Results demonstrate statistically significant SNR improvements for motion artifacts (ΔSNR = 9.47 ± 1.96 dB, t(9) = 15.28, p < 0.001) and EMG artifacts (ΔSNR = 16.73 ± 0.91 dB, t(9) = 58.11, p < 0.0001). Post-filtering morphological fidelity was high, with mean Pearson correlation of 0.963 for motion artifacts and 0.945 for muscle artifacts. These signal quality improvements translated into 95.3% post-filtering arrhythmia detection accuracy (sensitivity: ≈96.0%, specificity: ≥97.0%, F1-score: ≥95.0%), significantly exceeding the 70% minimum performance threshold adopted in this study as a conservative screening criterion (t(9) = 29.7, p < 0.001). Despite dataset limitations (n = 10), the proposed framework provides an effective trade-off between computational efficiency and diagnostic reliability, supporting scalable and real-time ambulatory ECG monitoring for early arrhythmia screening.
Co-Authors A. Senthil Kumar Abd . Kholiq Abdul Kholiq Abdullayev, Vugar Alhaq, Elmira Rofida Amrinsani, Farid Andjar Pudji Anita Miftahul Maghfiroh Aulia, Farahun Nisa Bambang Guruh I Bambang Guruh Irianto Bima Maulana Raharjo Caesar Febri Nugroho Candra Prastyadi Chandra Bimantara Putra Decoriza Kurnia Abadi Dimas Adi tya Dwi K, Rizky Dwi S, Frendi Agung Dyah Titisari, Dyah Elmira Rofida Al Haq Endro Yulianto Farisy Azis Satria Wardhana Febrianti, Fani Forra Wakidi, Levana Frendi Agung Dwi Saputra Gadang Hendra Prabowo Hamzah, Torib Hanna Firdaus Her Gumiwang Her Gumiwang Ariswati I Dewa Gede Hari Wisana Jing Lu Kurniawan, Desi Dwi Lamidi, Lamidi Levana Fora Wakidi Liliek Soetjiatie Lusiana Luthfiyah, Sari Mak’ruf, Muhammad Ridha Mansour Asghari Muhammad Ridha Mak'ruf Muhammad Syifaul Linnas Muzachim, Zuva Muzni Zahar Nazila Ragimova Nisa'ul Sholihah Nugraha, Priyambada C. Nurul Al Istigho Farola Prastawa Assalim Tetra Putra Priyambada Cahya Nugraha Putra, Chandra Bimantara Rabani, Rifqi Ragimova, Nazila Rangga Adi Firmansyah Rathod, Yagnik RATNA TAN Roichatun Nashichah Sella Octa Ardila Setiawan, Singgih Yudha Setioningsih, Endang Dian Sintiyah, Elisa Ayu Syafiq Naufal Syayakti Syaifudin Syaifudin , Syaifudin Syevana Dita Musvika Tetra Putra, Moch Prastawa Assalim Tetrik Fa’altin Torib Hamzah Torib Hamzah Triwiyanto Triwiyanto Ullah, Naqeeb Utomo, Bedjo Vijay Anant Athavale Vugar Abdullayev Vugar Abdullayev Wahyu Caesarendra Wahyu Caesarendra Wahyu Ramadhan Putra Wardhana, Farisy Azis Satria Zahar, Muzni