Rancang Bangun Spin Coater Vakum Chuck Berbasis Mikrokontroler dengan Tuning PID Metode Ziegler-Nichols Septiawan, Bayu; Mardiana, Laili; Hudha, Lalu Sahrul
Indonesian Journal of Applied Science and Technology Vol. 6 No. 1 (2025): Edisi Januari-Juni 2025
Publisher : Indonesian

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Spin coating is a thin-film deposition method that utilizes centrifugal force to produce uniform coatings; however, commercial instruments are expensive and therefore difficult to access for educational laboratories. This study aims to design and develop an ESP32-based spin coater equipped with a vacuum chuck system and motor speed control using a PID algorithm, with parameter tuning based on the Ziegler–Nichols method. The research methodology includes hardware and software design, component selection such as a brushed DC motor XD-3420, KY-003 Hall effect sensor, BTS7960 motor driver, and a vacuum system to hold the substrate. Performance testing was conducted through RPM sensor calibration, determination of optimal PWM frequency, and comparison between conventional control and PID control. The results show that the developed system is capable of reaching a maximum speed of 8500 rpm with a resolution of 0.1 rpm, linearity of 99.94%, and accuracy of 98.72% compared to a tachometer. The optimal operating frequency range of the system is 6000–8000 Hz with a sensitivity of 366.08 rpm/volt. PID control provides the best performance with a response time of 300 ms, an overshoot of 21.14%, and a steady-state error of 42.8 rpm. In conclusion, the proposed spin coater delivers precise and stable speed control, making it suitable for thin-film–based materials research in educational laboratories.
Application of Quality Control in Mobile Digital Radiography and Lead Apron Performance Testing Using CT Scan at West Nusa Tenggara Provincial General Hospital Putri , Baiq Alifa Kanaya; Septiawan, Bayu; Hudha, Lalu Sahrul
Indonesian Journal of Applied Science and Technology Vol. 7 No. 1 (2026): Edisi Januari-Juni 2026
Publisher : Indonesian

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The use of Mobile Digital Radiography (Mobile DR) in radiology services continues to rise due to its flexibility and efficiency; consequently, the implementation of Quality Control (QC) and regular evaluation of radiation protection equipment are necessary to ensure service quality and radiation safety. This study aims to evaluate the implementation of QC on Mobile DR equipment and to assess the suitability of lead aprons using CT scans at the Radiology Department of the NTB Provincial General Hospital. This is a quantitative descriptive study with the research subjects comprising one unit of mobile DR and 13 lead aprons. QC testing was conducted on the parameters of illumination, collimation, and X-ray beam alignment, while the apron suitability test was performed using a 64-slice CT scan to detect lead material leakage. The results showed that the illumination value was 198 lux, collimation was within tolerance limits, and beam alignment was 0°, meaning the Mobile DR unit was deemed to meet suitability standards. Furthermore, 5 out of 13 lead aprons (38.46%) exhibited leakage exceeding tolerance limits and were deemed unfit for use. These findings underscore the importance of implementing quality control (QC) and regular inspections of radiation protection equipment as part of the Quality Assurance programme to ensure the quality of radiology services and radiation safety at the NTB Provincial General Hospital.